Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-22224865

RESUMO

The objective of this study was to investigate a bioreactor suitable for human bladder regeneration. Simulations were performed using the computational fluid dynamic tools. The thickness of the bladder scaffold was 3 mm, similar to the human bladder, and overall hold-up volume within the spherical shape scaffold was 755 ml. All simulations were performed using (i) Brinkman equation on porous regions using the properties of 1% chitosan-1% gelatin structures, (ii) Michaelis-Menten type rate law nutrient consumption for smooth muscle cells (SMCs) and (iii) Mackie-Meares relationship for determining effective diffusivities. Steady state simulations were performed using flow rates from 0.5 to 5 ml/min. Two different inlet shapes: (i) straight entry at the centre (Design 1) and (ii) entry with an expansion (Design 2) were simulated to evaluate shear stress distribution. Also, mimicking bladder shape of two inlets (Design 3) was tested. Design 2 provided the uniform shear stress at the inlet and nutrient distribution, which was further investigated for the effect of scaffold locations within the reactor: (i) attached with a 3-mm open channel (Design 2-A), (ii) flow through with no open channel (Design 2-B) and (iii) porous structure suspended in the middle with 1.5-mm open channel on either side (Design 2-C). In Design 2-A and 2-C, fluid flow occurred by diffusion dominant mechanisms. Furthermore, the designed bioreactor is suitable for increased cell density of SMCs. These results showed that increasing the flow rate is necessary due to the decreased permeability at cell densities similar to the human bladder.


Assuntos
Reatores Biológicos , Simulação por Computador , Modelos Biológicos , Regeneração , Engenharia Tecidual/métodos , Bexiga Urinária/fisiologia , Glucose/análise , Humanos , Miócitos de Músculo Liso/citologia , Miócitos de Músculo Liso/metabolismo , Oxigênio/análise , Permeabilidade , Porosidade , Pressão , Estresse Mecânico , Bexiga Urinária/citologia , Bexiga Urinária/metabolismo
2.
Biotechnol Prog ; 28(4): 1045-54, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22473960

RESUMO

In this study, transport characteristics in flow-through and parallel-flow bioreactors used in tissue engineering were simulated using computational fluid dynamics. To study nutrient distribution and consumption by smooth muscle cells colonizing the 100 mm diameter and 2-mm thick scaffold, effective diffusivity of glucose was experimentally determined using a two-chambered setup. Three different concentrations of chitosan-gelatin scaffolds were prepared by freezing at -80°C followed by lyophilization. Experiments were performed in both bioreactors to measure pressure drop at different flow rates. At low flow rates, experimental results were in agreement with the simulation results for both bioreactors. However, increase in flow rate beyond 5 mL/min in flow-through bioreactor showed channeling at the circumference resulting in lower pressure drop relative to simulation results. The Peclet number inside the scaffold indicated nutrient distribution within the flow-through bioreactor to be convection-dependent, whereas the parallel-flow bioreactor was diffusion-dependent. Three alternative design modifications to the parallel-flow were made by (i) introducing an additional inlet and an outlet, (ii) changing channel position, and (iii) changing the hold-up volume. Simulation studies were performed to assess the effect of scaffold thickness, cell densities, and permeability. These new designs improved nutrient distribution for 2 mm scaffolds; however, parallel-flow configuration was found to be unsuitable for scaffolds more than 4-mm thick, especially at low porosities as tissues regenerate. Furthermore, operable flow rate in flow-through bioreactors is constrained by the mechanical strength of the scaffold. In summary, this study showed limitations and differences between flow-through and parallel-flow bioreactors used in tissue engineering.


Assuntos
Reatores Biológicos , Miócitos de Músculo Liso/citologia , Engenharia Tecidual/instrumentação , Animais , Contagem de Células , Proliferação de Células , Quitosana/química , Simulação por Computador , Gelatina/química , Glucose/metabolismo , Hidrodinâmica , Cinética , Miócitos de Músculo Liso/metabolismo , Permeabilidade , Porosidade , Pressão , Ratos , Engenharia Tecidual/métodos , Alicerces Teciduais/química
SELEÇÃO DE REFERÊNCIAS