Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hemodial Int ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38783838

RESUMO

INTRODUCTION: Progressive clogging of the dialyzer membrane during hemodialysis can compromise solute removal efficiency. Existing solutions fall short in addressing intradialytic reduction of dialyzer clearance. This pilot study aims to assess the impact and safety of applying therapeutic ultrasonic waves to dialyzers for mitigating intradialytic clogging. METHODS: In this pilot study, 15 stable maintenance hemodialysis patients (12 males and 3 females) were enrolled. Each patient served as their own control. They underwent one session of hemodialysis with the application of therapeutic ultrasonic waves (Ultrasonic session) and were crossed-over to a second session without the use of ultrasonic waves (Control session). All the study sessions operated at a fixed dialysate flow rate of 500 mL/min and a blood flow rate of 250 or 300 mL/min. The adequacy of dialysis achieved during each session was monitored using Online Clearance Monitoring of the dialysis machines, and clearance K values, varying between 135 and 209 mL/min, were recorded, and plotted. A direct comparison between Control and Ultrasonic sessions was performed to assess the impact and safety of using ultrasonic waves during hemodialysis. FINDINGS: The mean percentage decline in dialyzer clearance values was 4.41% for Ultrasonic sessions (SD: 5.3) and 12.69% for Control sessions (SD: 6.35) (p-value <0.001). This indicates that the application of ultrasonic waves reduced the decline in clearance values. The mean differences of the blood component parameters were comparable between both Ultrasonic sessions and Control sessions, suggesting the safety of utilizing ultrasonic waves during dialysis. Microscopic membrane analysis corroborated the safety. DISCUSSION: Intradialytic clogging of dialyzer membranes is a significant problem that can cause dialysis inadequacy. Our study tackles this issue by introducing therapeutic ultrasonic waves to improve dialyzer clearance during hemodialysis sessions in patients.

2.
Asia Pac J Clin Nutr ; 31(1): 142-146, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35357112

RESUMO

BACKGROUND AND OBJECTIVES: South Asians are known to have excess adiposity at a lower body mass index, with truncal fat accumulation. Whether this confers higher risk to develop severe COVID-19 is not known. This study evaluated body mass index, body fat mass and waist circumference as risk factors for COVID-19 severity and its progression, in South Asian adults. METHODS AND STUDY DESIGN: Details of COVID-19 patients (19-90 years) were obtained prospectively, along with weight, height, waist circumference and body fat mass assessed by bioelectrical impedance analysis. Binomial logistic and Poisson regression were performed to test associations between waist circumference, body fat mass and body mass index to evaluate the adjusted OR or relative risk for disease severity at admission and length of stay. RESULTS: After adjusting for age, sex, height and co-morbidities, body mass index >23 kg/m2 (adjusted OR 2.758, 95% CI 1.025, 7.427), waist circumference (adjusted OR 1.047, 95% CI 1.002, 1.093) and body fat mass (adjusted OR 1.111, 95% CI 1.013, 1.219) were associated with a significant risk for disease severity at admission, while only waist circumference (adjusted relative risk 1.004, 95% CI 1.001, 1.008), and body fat mass (adjusted relative risk 1.011, 95% CI 1.003, 1.018), were associated with a significantly longer length of stay. CONCLUSIONS: Body mass index, at a lower cut-off of >23 kg/m2, is a significant risk factor for COVID-19 disease severity in the group of patients studied. The waist circumference and body fat mass are also good indicators for both severity at admission and length of stay.


Assuntos
COVID-19 , Obesidade Abdominal , Adulto , Povo Asiático , Índice de Massa Corporal , COVID-19/epidemiologia , Humanos , Obesidade Abdominal/complicações , Obesidade Abdominal/epidemiologia , Fatores de Risco
3.
Saudi J Kidney Dis Transpl ; 28(2): 392-395, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28352026

RESUMO

Acute urinary retention is a rare cause of hyponatremia. Symptomatic acute hyponatremia is of grave medical concern and needs to be managed aggressively. In our two cases with acute urinary retention, a simple bladder catheterization and drainage of urine followed by conservative management resulted in complete resolution of symptoms and normalization of sodium levels. Association of bladder distension and hyponatremia is considered to be due to release of vasopressin triggered by bladder distension itself or by pain due to bladder distension. These cases are presented to bring to light an unusual and easily treatable cause of hyponatremia.


Assuntos
Hiponatremia/etiologia , Sódio/sangue , Retenção Urinária/complicações , Doença Aguda , Adulto , Biomarcadores/sangue , Tratamento Conservador , Drenagem/métodos , Feminino , Humanos , Hiponatremia/sangue , Hiponatremia/diagnóstico , Hiponatremia/terapia , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Cateterismo Urinário , Retenção Urinária/diagnóstico , Retenção Urinária/terapia
4.
Indian J Occup Environ Med ; 18(1): 27-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25006313

RESUMO

A 25-year-old young male patient presented in casualty department with severe respiratory distress on the fourth day from onset of symptoms. The patient was nonsmoker and had no antecedent medical or drug history. Prior to admission, patient had dry cough and bilateral pleuritic chest pain for the last three days. He was in severe respiratory distress with use of accessory muscles of respiration. On examination, he had heart rate of 120 beats/min, blood pressure (BP) of 150/80, respiratory rate of 48-52/min and central cyanosis present. On systemic examination, reduced intensity of breath sounds with extensive rhonchi and crepitation was found in both lung fields, with other examination being within normal limits. On pulse oximetry, oxygen saturation was 28% on room air, which increased up to 36% with the help of 4 L oxygen via nasal prongs. PaO2/FiO2 ratio was 100. Chest X-ray analysis was suggestive of non-cardiac pulmonary edema in view of bilateral fluffy opacity without cardiomegaly. In view of 2/3 positive criteria, his provisional diagnosis was Acute Respiratory Distress Syndrome (ARDS). He required mechanical ventilatory support and was gradually weaned over a period of 10 days. The patient was treated with broad spectrum antibiotics and other supportive measures. On re-evaluation of history, we found that he was a goldsmith by occupation, smelting silver and gold for the past 8-10 years. On the day of onset of symptoms, while smelting silver he was exposed to golden yellow fumes for around 15 minutes, with the quantum of exposure more than any other day earlier. From previous experience and analysis of similar silver metals, he was able to tell us that the silver was adulterated with large amount of cadmium on that day than before. Serum level of cadmium was 2.9 µg/L 6 days after initial exposure. At the time of discharge, he had residual opacities in the chest radiograph and resting oxygen saturation was 94% on room air.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...