1.
Med Phys ; 47(8): 3658-3668, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32395821

RESUMO

PURPOSE: The development of novel detectors for dosimetry in advanced radiotherapy modalities requires materials that have a water equivalent response to ionizing radiation such that characterization of radiation beams can be performed without the need for complex calibration procedures and correction factors. Organic semiconductors are potentially an ideal technology in fabricating devices for dosimetry due to tissue equivalence, mechanical flexibility, and relatively cheap manufacturing cost. The response of a commercial organic photodetector (OPD), coupled to a plastic scintillator, to ionizing radiation from a linear accelerator and orthovoltage x-ray tube has been characterized to assess its potential as a dosimeter for radiotherapy. The radiation hardness of the OPD has also been investigated to demonstrate its longevity for such applications. METHODS: Radiation hardness measurements were achieved by observing the response of the OPD to the visible spectrum and 70 keV x rays after pre-exposure to 40 kGy of ionizing radiation. The response of a preirradiated OPD to 6-MV photons from a linear accelerator in reference conditions was compared to a nonirradiated OPD with respect to direct and indirect (RP400 plastic scintillator) detection mechanisms. Dose rate dependence of the OPD was measured by varying the surface-to-source distance between 90 and 300 cm. Energy dependence was characterized from 29.5 to 129 keV with an x-ray tube. The percentage depth dose (PDD) curves were measured from 0.5 to 20 cm and compared to an ionization chamber. RESULTS: The OPD sensitivity to visible light showed substantial degradation of the broad 450 to 600 nm peak from the donor after irradiation to 40 kGy. After irradiation, the spectral shape has a dominant absorbance peak at 370 nm, as the acceptor better withstood radiation damage. Its response to x rays stabilized to 30% after 35 kGy, with a 0.5% difference between 770 Gy increments. The OPD exhibited reproducible detection of ionizing radiation when coupled with a scintillator. Indirect detection showed a linear response from 25 to 500 cGy and constant response to dose rates from 0.31 Gy/pulse to 3.4 × 10-4  Gy/pulse. However, without the scintillator, response increased by 100% at low dose rates. Energy independence between 100 keV and 1.2 MeV advocates their use as a dosimeter without beam correction factors. A dependence on the scintillator thickness used during a comparison of the PDD to the ionizing chamber was identified. A 1-mm-thick scintillator coupled with the OPD demonstrated the best agreement of ± 3%. CONCLUSIONS: The response of OPDs to ionizing radiation has been characterized, showing promising use as a dosimeter when coupled with a plastic scintillator. The mechanisms of charge transport and trapping within organic materials varies for visible and ionizing radiation, due to differing properties for direct and indirect detection mechanisms and observing a substantial decrease in sensitivity to the visible spectrum after 40 kGy. This study proved that OPDs produce a stable response to 6-MV photons, and with a deeper understanding of the charge transport mechanisms due to exposure to ionizing radiation, they are promising candidates as the first flexible, water equivalent, real-time dosimeter.


Assuntos
Dosímetros de Radiação , Radiometria , Aceleradores de Partículas , Fótons , Semicondutores
2.
Phys Imaging Radiat Oncol ; 14: 48-52, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33458314

RESUMO

BACKGROUND AND PURPOSE: Measurement of dose delivery is essential to guarantee the safety of patients undergoing medical radiation imaging or treatment procedures. This study aimed to evaluate the ability of organic semiconductors, coupled with a plastic scintillator, to measure photon dose in clinically relevant conditions, and establish its radiation hardness. Thereby, proving organic devices are capable of being a water-equivalent, mechanically flexible, real-time dosimeter. MATERIALS AND METHODS: The shelf-life of an organic photodiode was analyzed to 40 kGy by comparison of the charge-collection-efficiency of a 520 nm light emitting diode. A non-irradiated and pre-irradiated photodiode was coupled to a plastic scintillator and their response to 6 MV photons was investigated. The dose linearity, dose-per-pulse dependence and energy dependence was characterized. Finally, the percentage depth dose (PDD) between 0.5 and 20 cm was compared with ionization chamber measurements. RESULTS: Sensitivity to 6 MV photons was (190 ± 0.28) pC/cGy and (170 ± 0.11) pC/cGy for the non-irradiated and pre-irradiated photodiode biased at -2 V. The response was independent of the dose-per-pulse between 0.031 and 0.34 mGy/pulse. An energy dependence was found for low keV energies, explained by the energy dependence of the scintillator which plateaued between 70 keV and 1.2 MeV. The PDD was within ±3% of the ionization chamber. CONCLUSION: Coupling an organic photodiode with a plastic scintillator provided reliable measurement of a range of photon energies. Dose-per-pulse and energy independence advocate their use as a dosimeter, specifically image-guided treatment without beam-quality correction factors. Degradation effects of organic semiconducting materials deteriorate sensor response but can be stabilized.

3.
Sci Rep ; 6: 39201, 2016 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-28004819

RESUMO

Printed organic photodetectors can transform plastic, paper or glass into smart surfaces. This innovative technology is now growing exponentially due to the strong demand in human-machine interfaces. To date, only niche markets are targeted since organic sensors still present reduced performances in comparison with their inorganic counterparts. Here we demonstrate that it is possible to engineer a state-of-the-art organic photodetector approaching the performances of Si-based photodiodes in terms of dark current, responsivity and detectivity. Only three solution-processed layers and two low-temperature annealing steps are needed to achieve the performance that is significantly better than most of the organic photodetectors reported so far. We also perform a long-term ageing study. Lifetimes of over 14,000 hours under continuous operation are more than promising and demonstrate that organic photodetectors can reach a competitive level of stability for successful commercialization of this new and promising technology.

4.
Opt Express ; 23(21): 27536-41, 2015 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-26480413

RESUMO

Organic Photo Sensor (OPS) technology allows printing on conformable plastic-like substrates complex-shaped, arbitrarily-sized and pre-aligned photosensitive elements. This article reports, to the best of our knowledge, the first investigation to implement this emerging technology for Multi-Angle Light Scattering (MALS) characterization of nano- and microparticle suspensions. Monte Carlo and Lorenz-Mie theory calculations as well as preliminary experimental results on latex suspensions clearly demonstrate the potential of the proposed approach.

5.
Adv Mater ; 25(45): 6534-8, 2013 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-24136640

RESUMO

Organic photodetectors with inverted structure are fabricated by solution process techniques. A very thin interfacing layer of polyethyleneimine leads to a homogenous interface with low work function. The devices exhibit excellent performances, in particular in terms of low dark current density, wide range linearity, high detectivity, and remarkable stability in ambient air without encapsulation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...