Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Hum Neurosci ; 16: 901387, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35911603

RESUMO

Technologies like passive brain-computer interfaces (BCI) can enhance human-machine interaction. Anyhow, there are still shortcomings in terms of easiness of use, reliability, and generalizability that prevent passive-BCI from entering real-life situations. The current work aimed to technologically and methodologically design a new gel-free passive-BCI system for out-of-the-lab employment. The choice of the water-based electrodes and the design of a new lightweight headset met the need for easy-to-wear, comfortable, and highly acceptable technology. The proposed system showed high reliability in both laboratory and realistic settings, performing not significantly different from the gold standard based on gel electrodes. In both cases, the proposed system allowed effective discrimination (AUC > 0.9) between low and high levels of workload, vigilance, and stress even for high temporal resolution (<10 s). Finally, the generalizability of the proposed system has been tested through a cross-task calibration. The system calibrated with the data recorded during the laboratory tasks was able to discriminate the targeted human factors during the realistic task reaching AUC values higher than 0.8 at 40 s of temporal resolution in case of vigilance and workload, and 20 s of temporal resolution for the stress monitoring. These results pave the way for ecologic use of the system, where calibration data of the realistic task are difficult to obtain.

2.
Brain Sci ; 12(3)2022 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-35326261

RESUMO

Driver's stress affects decision-making and the probability of risk occurrence, and it is therefore a key factor in road safety. This suggests the need for continuous stress monitoring. This work aims at validating a stress neurophysiological measure-a Neurometric-for out-of-the-lab use obtained from lightweight EEG relying on two wet sensors, in real-time, and without calibration. The Neurometric was tested during a multitasking experiment and validated with a realistic driving simulator. Twenty subjects participated in the experiment, and the resulting stress Neurometric was compared with the Random Forest (RF) model, calibrated by using EEG features and both intra-subject and cross-task approaches. The Neurometric was also compared with a measure based on skin conductance level (SCL), representing one of the physiological parameters investigated in the literature mostly correlated with stress variations. We found that during both multitasking and realistic driving experiments, the Neurometric was able to discriminate between low and high levels of stress with an average Area Under Curve (AUC) value higher than 0.9. Furthermore, the stress Neurometric showed higher AUC and stability than both the SCL measure and the RF calibrated with a cross-task approach. In conclusion, the Neurometric proposed in this work proved to be suitable for out-of-the-lab monitoring of stress levels.

3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 4619-4622, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30441381

RESUMO

This study aims at investigating the possibility to employ neurophysiological measures to assess the humanmachine interaction effectiveness. Such a measure can be used to compare new technologies or solutions, with the final purpose to enhance operator's experience and increase safety. In the present work, two different interaction modalities (Normal and Augmented) related to Air Traffic Management field have been compared, by involving 10 professional air traffic controllers in a control tower simulated environment. Experimental task consisted in locating aircrafts in different airspace positions by using the sense of hearing. In one modality (i.e. "Normal"), all the sound sources (aircrafts) had the same amplification factor. In the "Augmented" modality, the amplification factor of the sound sources located along the participant head sagittal axis was increased, while the intensity of sound sources located outside this axis decreased. In other words, when the user oriented his head toward the aircraft position, the related sound was amplified. Performance data, subjective questionnaires (i.e. NASA-TLX) and neurophysiological measures (i.e. EEG-based) related to the experienced workload have been collected. Results showed higher significant performance achieved by the users during the "Augmented" modality with respect to the "Normal" one, supported by a significant decreasing in experienced workload, evaluated by using EEG-based index. In addition, Performance and EEG-based workload index showed a significant negative correlation. On the contrary, subjective workload analysis did not show any significant trend. This result is a demonstration of the higher effectiveness of neurophysiological measures with respect to subjective ones for Human-Computer Interaction assessment.


Assuntos
Aeronaves , Sistemas Homem-Máquina , Localização de Som , Análise e Desempenho de Tarefas , Carga de Trabalho , Percepção Auditiva , Eletroencefalografia , Audição , Humanos , Monitorização Neurofisiológica , Ocupações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...