1.
Adv Med ; 2014: 307168, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26556408

RESUMO

The Transvalvular Impedance (TVI) is derived between atrial and ventricular pacing electrodes. A sharp TVI increase in systole is an ejection marker, allowing the hemodynamic surveillance of ventricular stimulation effectiveness in pacemaker patients. At routine follow-up checks, the ventricular threshold test was managed by the stimulator with the supervision of a physician, who monitored the surface ECG. When the energy scan resulted in capture loss, the TVI system must detect the failure and increase the output voltage. A TVI signal suitable to this purpose was present in 85% of the tested patients. A total of 230 capture failures, induced in 115 patients in both supine and sitting upright positions, were all promptly recognized by real-time TVI analysis (100% sensitivity). The procedure was never interrupted by the physician, as the automatic energy regulation ensured full patient's safety. The pulse energy was then set at 4 times the threshold to test the alarm specificity during daily activity (sitting, standing up, and walking). The median prevalence of false alarms was 0.336%. The study shows that TVI-based ejection assessment is a valuable approach to the verification of pacing reliability and the autoregulation of ventricular stimulation energy.

2.
Artigo em Inglês | MEDLINE | ID: mdl-23446212

RESUMO

AIMS: To assess the acute side-effects of right ventricular (RV) stimulation applied in apex and mid-septum, in order to establish the optimal lead location in clinical practice. METHODS: During pacemaker implantation, the ventricular lead was temporarily fixed in the apex and then moved to mid-septum. In both positions, surface and endocardial electrograms and transvalvular impedance (32 cases), left ventricular (LV) pressure (23), and transthoracic echocardiography (10) were acquired with intrinsic activity and VDD pacing. RESULTS: A larger increase in QRS duration was noticed with apical than septal pacing (65±25 vs. 45±29 ms; P<10(-4)). The proportion of cases where RV stimulation affected the transvalvular impedance waveform was higher with apical lead location (56% vs. 20%; P<0.02). VDD pacing at either site reduced the maximum dP/dt by 6% with respect to intrinsic AV conduction (IAVC; P<0.005). The maximum pressure drop taking place in 100 ms was reduced by 6 and 8%, respectively, with apical and septal pacing (P<0.01 vs. IAVC). Apical VDD decreased mitral annulus velocity in early diastole (E') from 7.5±1.4 to 5.9±0.9 cm/s (P<0.02) and prolonged the E-wave deceleration time (DT) from 156±33 to 199±54 ms (P<0.02), while septal pacing induced non-significant modifications in E' and DT. CONCLUSION: Ventricular stimulation acutely impairs LV systolic and diastolic performance, independent of the pacing site. Septal lead location preserves RV contraction mechanics and reduces the electrical interventricular delay.


Assuntos
Estimulação Cardíaca Artificial/métodos , Impedância Elétrica/uso terapêutico , Ventrículos do Coração/fisiopatologia , Hemodinâmica/fisiologia , Função Ventricular/fisiologia , Estimulação Cardíaca Artificial/efeitos adversos , Ecocardiografia , Impedância Elétrica/efeitos adversos , Eletrocardiografia , Humanos , Volume Sistólico
3.
J Atr Fibrillation ; 7(1): 1075, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-27957085

RESUMO

The discrimination between ventricular (VT) and supraventricular tachycardia (SVT) and the evaluation of their hemodynamic impact are essential issues in the arrhythmia management. A new pacing device features a tachycardia diagnostic system relying on simultaneous recording of the transvalvular impedance (TVI) and a special integrated electric signal derived by the whole set of endocardial electrodes (iECG). The iECG waveform is sensitive to the pattern of ventricular activation, similarly to the surface ECG. The TVI increases in systole and decreases in diastole and the amplitude of this cyclic fluctuation is an expression of the effectiveness of the pump function. In order to test the value of these signals in the analysis of a tachycardia, we have assessed the iECG and TVI modifications induced by different SVTs and tolerated and non-tolerated VTs, during electrophysiological (EP) studies. In case of SVT, the ventricular component of the iECG maintained the same morphology as in sinus rhythm. The peak-peak amplitude of the TVI fluctuation was reduced to 66 ± 11 % of the individual sinus rhythm reference, but the signal was present at every beat and showed a remarkable stability (variation coefficient 0.19 ± 0.01). In case of VT, the ventricular component of the iECG was strikingly different than in sinus rhythm. Regular TVI fluctuation was observed with tolerated VTs (peak-peak amplitude 74 ± 6 %; variation coefficient 0.21 ± 0.04). In contrast, with non-tolerated VTs the TVI amplitude was depressed below 40%, and the signal was virtually absent in the event of very fast VT or VF. Our results confirm that the iECG is a reliable tool to quickly discriminate VTs from SVTs and that TVI can provide information on the severity of the hemodynamic impairment produced by a tachycardia, with potential clinical benefit in the follow-up of pacemaker patients. Furthermore, the application of these signals to automatic algorithms of arrhythmia recognition might improve the specificity of therapy administration by an implantable defibrillator (ICD).

4.
PLoS One ; 8(11): e80591, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24260431

RESUMO

BACKGROUND: The real-time and continuous assessment of left ventricular (LV) myocardial contractility through an implanted device is a clinically relevant goal. Transvalvular impedance (TVI) is an impedentiometric signal detected in the right cardiac chambers that changes during stroke volume fluctuations in patients. However, the relationship between TVI signals and LV contractility has not been proven. We investigated whether TVI signals predict changes of LV inotropic state during clinically relevant loading and inotropic conditions in swine normal heart. METHODS: The assessment of RVTVI signals was performed in anesthetized adult healthy anesthetized pigs (n = 6) instrumented for measurement of aortic and LV pressure, dP/dtmax and LV volumes. Myocardial contractility was assessed with the slope (Ees) of the LV end systolic pressure-volume relationship. Effective arterial elastance (Ea) and stroke work (SW) were determined from the LV pressure-volume loops. Pigs were studied at rest (baseline), after transient mechanical preload reduction and afterload increase, after 10-min of low dose dobutamine infusion (LDDS, 10 ug/kg/min, i.v), and esmolol administration (ESMO, bolus of 500 µg and continuous infusion of 100 µg·kg-1·min-1). RESULTS: We detected a significant relationship between ESTVI and dP/dtmax during LDDS and ESMO administration. In addition, the fluctuations of ESTVI were significantly related to changes of the Ees during afterload increase, LDDS and ESMO infusion. CONCLUSIONS: ESTVI signal detected in right cardiac chamber is significantly affected by acute changes in cardiac mechanical activity and is able to predict acute changes of LV inotropic state in normal heart.


Assuntos
Impedância Elétrica , Valvas Cardíacas/fisiologia , Contração Miocárdica/fisiologia , Função Ventricular Esquerda , Animais , Pressão Sanguínea , Hemodinâmica , Masculino , Modelos Animais , Volume Sistólico , Suínos
5.
J Interv Card Electrophysiol ; 34(1): 105-13, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21993598

RESUMO

AIMS: Complications of implantable cardioverter-defibrillator (ICD) therapy are often linked to transvenous lead insertion, lead failure, or infections. An entirely subcutaneous ICD system (S-ICD) avoids the need for the placement of electrodes within the heart and can provide clinical advantages. METHODS AND RESULTS: A 45-year-old patient with Brugada syndrome (spontaneous type 1 Brugada ECG, syncope during fever, family history of sudden death <45 years old) was implanted with an entirely S-ICD. A left lateral incision was made over the sixth rib in the anterior axillary line for pocket formation and pulse generator placement. The subcutaneous electrode was placed subcutaneously, parallel to and 2 cm to the left of the sternal midline, and was connected to the generator. The insertion of the system was guided only by anatomical landmarks, and no fluoroscopy was required. Ventricular fibrillation was induced and terminated by a 65-J shock (15-J safety margin). No complication occurred, and subsequent course was uneventful. CONCLUSIONS: S-ICD is a new system for delivering lifesaving shock therapy in patients at risk of sudden cardiac death, without the need of intracardiac leads. Young patients with inherited arrhythmogenic syndromes could benefit the most from this system. This is the first case of Brugada syndrome implanted with a first-generation S-ICD in Italy.


Assuntos
Síndrome de Brugada/diagnóstico , Síndrome de Brugada/prevenção & controle , Desfibriladores Implantáveis , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
6.
Clin Imaging ; 34(5): 337-43, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20813295

RESUMO

When the anomalous origin of coronary arteries (AOCA) is suspected in children (especially athletes), due to signs and symptoms of myocardial ischemia or on the basis of echocardiographic assessment, three-dimensional coronary magnetic resonance angiography (3D-CMRA) can be proposed for the fine morphological evaluation of coronary branches anatomy and course. We tested the diagnostic potential of CMRA angiography in a prospective study on AOCA in young patients. Between July 2005 and June 2008, 15 patients aged 6-29 years (mean age, 13.5 years+/-5.6 S.D.; median, 14) with clinical and echocardiographic suspicion of AOCA underwent CMRA (1.5 T), 3D whole-heart, free-breathing technique, without the use of contrast medium and beta-blockers, with a mean examination time of 30 min. We acquired a second scan of all patients to ameliorate the quality of the acquisition and to improve our experience. AOCA was confirmed by 3D-CMRA in 8 out of 15 cases (53%) and three different anatomical variants were demonstrated, that is, ectopic origin of the left circumflex artery arising from the right coronary artery with retro-aortic course in four cases, single coronary artery arising from the right sinus of Valsalva with interarterial course in one case, ectopic right coronary artery arising from the left sinus of Valsalva with interarterial course in one case; in two patients without anomalies of origin of the coronary arteries, elongated LMCA with angulation of the proximal segment of the left circumflex artery was present. When AOCA is suspected particularly in children (especially athletes), CMRA without the use of contrast medium is an effective diagnostic technique, which is useful to clarify the spatial position of the anomalous course of the main coronary branches in order to suggest the most convenient management of the disease. CMRA does not need contrast medium, needles, and beta-blockers; is repeatable in the same examination without the exposure to X-rays; allows a parent to stay near the child; and needs low collaboration in low-stress conditions.


Assuntos
Anomalias dos Vasos Coronários/diagnóstico , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Adolescente , Adulto , Criança , Anomalias dos Vasos Coronários/complicações , Vasos Coronários/patologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Isquemia Miocárdica/etiologia , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
7.
Europace ; 12(4): 534-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20338989

RESUMO

AIMS: Recording and analysing impedance fluctuation along the cardiac cycle in the right (RV) and left ventricles (LV). METHODS AND RESULTS: During a biventricular (BiV) implantation procedure, impedance was sequentially derived between the atrial ring electrode and either electrode (tip or ring) of the RV lead [transvalvular impedance (TVI)], and between the atrial ring and either the tip or ring electrode of a coronary sinus lead, positioned in a cardiac vein [left ventricle impedance (LVI)]. The LVI signal was also recorded by the implanted pacemaker at the 1 day and 3 months follow-ups. With intrinsic conduction, TVI showed an average increase of 53 +/- 29 ohm during ventricular systole, whereas at the same time, LVI decreased by 45 +/- 21 ohm (25 and 23 patients, respectively, out of 28 tested cases). Transvalvular impedance and LVI displayed a similar time course, which appeared to be related to the systolic timing in the RV and LV. Both LVI amplitude and duration decreased as a function of the cardiac rate. The LVI deflection started immediately after LV stimulation, and often anticipated the R-wave sensing after contralateral pacing. At the 3-month follow-up, LVI amplitude was decreased in 70% of cases and increased in the remainder, with a non-significant average change of -5 +/- 85% with respect to the acute recordings. CONCLUSION: Transvalvular impedance properties are consistent with the assumption of an inverse relationship with RV volume. Though LVI requires a different physical interpretation, the waveform duration might reflect the timing of LV myocardial contraction. In this hypothesis, the relationship between TVI and LVI could provide insight into the effects of BiV pacing on mechanical synchronization.


Assuntos
Estimulação Cardíaca Artificial , Impedância Elétrica , Técnicas Eletrofisiológicas Cardíacas/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda/fisiologia , Volume Cardíaco/fisiologia , Seio Coronário/fisiologia , Eletrodos Implantados , Valvas Cardíacas/fisiologia , Humanos , Sístole/fisiologia , Veias/fisiologia , Função Ventricular Direita/fisiologia
8.
Europace ; 7(3): 234-41, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15878562

RESUMO

AIMS: Trans-valvular impedance (TVI) recording has been proposed for the assessment of cardiac haemodynamics, assuming an inverse relationship between TVI and ventricular volume. We checked whether the TVI sensor can drive the rate-responsive function of a cardiac pacemaker following changes in the inotropic regulation of the heart. METHODS: An external DDD-R pacemaker (Ext Sophos by Medico, Padova, Italy) equipped with the TVI detecting system was tested in 30 patients on the implantation of conventional pacing leads for dual-chamber pacing. Pacing rate regulation was based on the relationship between the stroke volume and the end-diastolic volume, inferred from TVI data. After sensor calibration in basal conditions, beta-adrenergic stimulation was induced by i.v. administration of 2 microg/ml/min isoprenaline (isoproterenol) (IPN). The actual cardiac rate, the TVI waveform, the end-diastolic and systolic TVI in each cardiac cycle and the TVI-indicated rate were stored in memory as a function of time and down-loaded at the end of the session. RESULTS: All patients with intrinsic atrial activity (28/30) showed a positive chronotropic response to IPN, coupled with a significant increase in end-diastolic TVI and a four-times larger increase in end-systolic TVI. The TVI inotropic index mirrored the sinus rate time-course, with a linear correlation between the two parameters (r(2)>0.7 in 25/28 cases). As a result, the TVI-indicated rate closely reproduced the sinus rate. CONCLUSIONS: The study confirms the reliability of the haemodynamic information derived from TVI and supports its application in the regulation of rate-responsive pacing.


Assuntos
Estimulação Cardíaca Artificial , Cardiografia de Impedância , Cardiotônicos/farmacologia , Hemodinâmica , Humanos , Isoproterenol/farmacologia , Modelos Lineares , Contração Miocárdica , Volume Sistólico
9.
J Electrocardiol ; 37 Suppl: 135-43, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15534823

RESUMO

Stimulation of myocardium by either a native pacemaker or an artificial stimulus requires the initiation of a self-propagating wave of depolarization originating from the site of initial activation. In the present study we perform artificial stimulation at a site of focal discharge with the aim to compare the two mechanisms of impulse formation. High resolution epicardial mapping in senescent rat hearts provided examples of focal discharge during sinus rhythm at a single epicardial breakthrough (BKT) point emerging from an isolated Purkinje-ventricular muscle junction (PMJ) site. Stimulation was also performed at the same BKT point and potential distributions recorded during spontaneous and artificial stimulation were compared. During excitation latency, the negative potential pattern was elongated perpendicularly to fiber direction at both pacing and BKT point, in agreement with virtual cathode membrane polarization predicted by the bidomain model during point stimulation. During impulse initiation, activation wave fronts were initially circular around pacing site or BKT point and then elongated along local fiber direction. The similarity between impulse initiation during focal discharge and point stimulation in cardiac muscle suggests that high resolution pace mapping studies can help to elucidate the mechanism of abnormal impulse formation.


Assuntos
Estimulação Cardíaca Artificial , Sistema de Condução Cardíaco/fisiologia , Contração Miocárdica/fisiologia , Animais , Mapeamento Potencial de Superfície Corporal , Eletrocardiografia , Sistema de Condução Cardíaco/anatomia & histologia , Potenciais da Membrana/fisiologia , Modelos Cardiovasculares , Pericárdio/fisiologia , Ramos Subendocárdicos/fisiologia , Ratos , Função Ventricular , Complexos Ventriculares Prematuros/fisiopatologia