Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Ophthalmol ; 259: 117-130, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37979601

RESUMO

PURPOSE: To evaluate risk factors for failure of Microshunt in glaucoma patients. DESIGN: Multicenter retrospective cohort study. METHODS: The study included 220 eyes from 220 consecutive glaucoma patients undergoing Microshunt implantation at six glaucoma units. Four intraocular pressure (IOP) success criteria were defined: (A) IOP ≤21 mm Hg with ≥20% IOP reduction; (B) IOP ≤18 mm Hg with ≥20% IOP reduction; (C) IOP ≤15 mm Hg with ≥25% IOP reduction; and (D) IOP ≤12 mm Hg with ≥30% IOP reduction from baseline. Kaplan-Meier analysis was used to estimate success rates according to the criteria above, and multivariable Cox models were used to identified risk factors for failure according to criterion A. RESULTS: Success rates varied based on different criteria, ranging from 43.3% to 62.5% (overall success for criteria D and A, respectively) and from 35.3% to 44.4% (complete success for criteria D and A, respectively) at 1-year follow-up. Higher intraoperative MMC concentration was associated with reduced risk of failure to maintain complete (0.4 vs 0.2 mg/mL: hazard ratio [HR] = 0.441, P < .001) and overall (0.4 vs 0.2 mg/mL: HR = 0.360, P = .004) success. For complete success, other risk factors for failure were pseudoexfoliation glaucoma/pigmentary glaucoma (HR = 1.641, P = .004), primary angle closure glaucoma (HR = 1.611, P < .001), and previous non-glaucomatous ocular surgeries (HR = 2.301, P = .002). For overall success, other risk factors for failure were lower preoperative IOP (for 1-mm Hg increase, HR = 0.934, P = .005), higher number of preoperative antiglaucoma agents (HR = 1.626, P < .001), and Microshunt combined with cataract surgery (HR = 1.526, P = .033). CONCLUSIONS: This study identified risk factors for Microshunt failure, highlighting the importance of high intraoperative MMC dose and careful patient selection to optimize surgical success.


Assuntos
Glaucoma , Trabeculectomia , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Mitomicina , Glaucoma/complicações , Glaucoma/cirurgia , Pressão Intraocular , Tonometria Ocular , Fatores de Risco
2.
Br J Ophthalmol ; 105(4): 484-489, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32522789

RESUMO

BACKGROUND/AIMS: To compare the accuracy of 13 formulas for intraocular lens (IOL) power calculation in cataract surgery. METHODS: In this retrospective interventional case series, optical biometry measurements were entered into these formulas: Barrett Universal II (BUII) with and without anterior chamber depth (ACD) as a predictor, EVO 2.0 with and without ACD as a predictor, Haigis, Hoffer Q, Holladay 1, Holladay 2AL, Kane, Næser 2, Pearl-DGS, RBF 2.0, SRK/T, T2 and VRF. The mean prediction error (PE), median absolute error (MedAE), mean absolute error and percentage of eyes with a PE within ±0.25, ±0.50, ±0.75 and ±1.00 diopters (D) were calculated. RESULTS: Two hundred consecutive eyes were enrolled. With all formulas, the mean PE was zero. The BUII with no ACD had the lowest standard deviation (±0.343 D), followed by the T2 (0.347 D), Kane (0.348 D), EVO 2.0 with no ACD (0.348 D) and BUII with ACD (0.353 D) formulas. The difference among the MedAEs of all formulas was statistically significant (p<0.0001); the lowest values were achieved with the Kane (0.214 D), RBF 2.0 (0.215 D), BUII with and without ACD (0.218 D) and SRK/T (0.223 D). A percentage ranging from 80% to 88.5% of eyes showed a PE within ±0.50 D and all formulas achieved more than 50% of eyes with a PE within ±0.25 D. CONCLUSION: All investigated formulas achieved good results; there was a tendency towards better outcomes with newer formulas. Traditional formulas can still be considered an accurate option.


Assuntos
Interferometria/métodos , Lentes Intraoculares , Óptica e Fotônica , Refração Ocular/fisiologia , Acuidade Visual , Idoso , Comprimento Axial do Olho/diagnóstico por imagem , Extração de Catarata , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos
3.
Eur J Ophthalmol ; 31(2): 698-703, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32066268

RESUMO

PURPOSE: The purpose of the present study was to compare visual function assessment, visual evoked potential, and optical coherence tomography with measurement of retinal nerve fiber layer thickness for the diagnosis of optic pathway glioma in children with neurofibromatosis type 1. METHODS: This retrospective observational study included patients with neurofibromatosis type 1 who underwent brain magnetic resonance imaging scan, visual evoked potential study, and peripapillary retinal nerve fiber layer evaluation by optical coherence tomography. Patients were tested with pattern-reversal visual evoked potential and with flash visual evoked potential in case of poor cooperation. Optical coherence tomography was performed with HRA Spectralis (Heidelberg Engineering, Heidelberg, Germany). The area under the curve of receiver operating characteristic curves was used to evaluate the accuracy of each parameter for diagnosing optic pathway glioma. RESULTS: In all, 110 patients with neurofibromatosis type 1 were included in the study. Fifty of them had an optic pathway glioma diagnosed with magnetic resonance imaging, while 60 did not. Global retinal nerve fiber layer thickness demonstrated the highest diagnostic power for discriminating patients with and without optic pathway glioma (area under the curve = 0.758, sensitivity = 65.3%, specificity = 83.3%), followed visual acuity (area under the curve = 0.723, sensitivity = 51.1%, specificity = 91.7%) and P100 of visual evoked potential (area under the curve = 0.712, sensitivity = 69.6%, specificity = 63.8%). CONCLUSION: The results of the present study showed that the measurement of retinal nerve fiber layer thickness was the most efficient test for discriminating patients with and without optic pathway glioma. Brain magnetic resonance imaging remains the gold standard to confirm the diagnosis of optic pathway glioma. Longitudinal studies are required to define if the early detection of tumors with optical coherence tomography could prevent vision loss and morbidity.


Assuntos
Potenciais Evocados Visuais/fisiologia , Neurofibromatose 1/fisiopatologia , Glioma do Nervo Óptico/fisiopatologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Seleção Visual/métodos , Acuidade Visual , Adolescente , Criança , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Fibras Nervosas/patologia , Neurofibromatose 1/diagnóstico , Glioma do Nervo Óptico/diagnóstico , Curva ROC , Estudos Retrospectivos , Campos Visuais/fisiologia
4.
J Pediatr Ophthalmol Strabismus ; 57(1): 39-43, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-31972039

RESUMO

PURPOSE: To investigate the presence of amblyopia risk factors in newborns with congenital nasolacrimal duct obstruction (CNLDO) and age-matched healthy control subjects. METHODS: This retrospective case-control study involved newborns aged 30 to 60 days with CNLDO and age-matched healthy control subjects. Amblyopia risk factors were identified in accordance with the American Association for Pediatric Ophthalmology and Strabismus Vision Screening Committee recommendations. The prevalence of amblyopia risk factors was compared in newborns with CNLDO and age-matched healthy control subjects, newborns with unilateral and bilateral CNLDO, and the affected eye and fellow eye of newborns with unilateral CNLDO. RESULTS: Amblyopia risk factors were found in 18 patients (11.9%) with CNLDO and 19 control subjects (8.7%) (P = .314). Eyes with CNLDO showed a significantly lower spherical equivalent compared to control eyes (2.01 ± 1.21 vs 2.79 ± 1.14 diopters, P < .001). No difference in amblyopia risk factors was found in eyes with unilateral and bilateral CNLDO (11.5% vs 12.1%; P = .908) or in eyes with unilateral CNLDO and fellow eyes (9.8% vs 12.3%; P = .540). CONCLUSIONS: CNLDO does not seem to be associated with amblyopia risk factors in newborns. Because anisometropia might develop later on, all patients with CNLDO should be monitored for amblyopia. [J Pediatr Ophthalmol Strabismus. 2020;57(1):39-43.].


Assuntos
Ambliopia/epidemiologia , Obstrução dos Ductos Lacrimais/congênito , Ducto Nasolacrimal/anormalidades , Peso ao Nascer , Estudos de Casos e Controles , Feminino , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Masculino , Prevalência , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...