Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
J Pers Med ; 14(4)2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38672969

RESUMO

The aim of the current study was to retrospectively investigate the prevalence of peri-implant mucositis (PIM) and peri-implantitis (P) in a long-term follow-up (≥20 years) of implants with the same body design and body surface but different collar surfaces with laser-microtextured grooves (LMGSs) vs. no laser-microtextured grooves (no-LMGSs) in private practice patients. Furthermore, several patient-related, implant-related, site-, surgical-, and prosthesis-related potential disease risk factors were analyzed. A chart review of patients receiving at least one pair of implants (one with an LMGS and the other without LMGS) in the period 1993-2002 was used. Chi-square analysis was used to determine if a statistically significant difference between the investigated variables and PIM/P was present. Possible risk factors were statistically evaluated by a binary logistic regression analysis. A total of 362 patients with 901 implant-supported restorations (438 with LMGS and 463 no-LMGS) were included in the study. The cumulative survival rates of implants at 5, 10, 15, and 20 years were 98.1%, 97.4%, 95.4%, and 89.8%, respectively, for the LMGS group, and 93.2%, 91.6%, 89.5%, and 78.3% for the no-LMGS group. The difference was statistically significant at all timepoints (p < 0.05). In total, at the end of the follow-up period, 45.7% of patients and 39.8% of implants presented PIM, and 15.6% of patients and 14% of implants presented P. A total of 164 LMGS implants (37.4%) and 195 no-LMGS implants (42.1%) presented peri-implant mucositis, while 28 (6.3%) of LMGS implants and 98 (21.1%) no-LMGS implants demonstrated peri-implantitis. Differences between LMGS implants and no-LMGS implants were statistically significant (p < 0.05). The binary logistic regression identified collar surface, cigarette smoking, histories of treated periodontitis, and lack of peri-implant maintenance as risk factors for P. After at least 20 years of function in patients followed privately, LMGS implants compared to no-LMGS implants presented a statistically and significantly lower incidence of P. Implant collar surface, cigarette smoking, previously treated periodontitis, and lack of peri-implant maintenance are factors with significant association to P.

2.
Int J Periodontics Restorative Dent ; (7): s118-s128, 2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37552172

RESUMO

This retrospective clinical study compared two different professional maintenance therapy (MT) approaches (with and without periodic removal and decontamination of prosthetic components) on peri-implant inflammatory clinical and biochemical parameters after 5 years of implant function. A retrospective analysis based on patient records was used to assess inflammatory clinical and biochemical parameters around dental implants placed by the same clinician in a private practice. The Plaque Index (PI), peri-implant probing depth (PPD), mucosal recession (REC), bleeding on probing (BOP), and radiographic marginal bone level were determined at baseline and at each follow-up year. Moreover, at the last follow-up visit, the peri-implant intrasulcular levels of active metalloproteinasis 8 (aMMP-8) were also assessed. All participants were under MT with a 6-month recall interval. A total of 92 patients with 132 implants were selected. At the end of the study period, 12 patients with 12 implants were classified as dropouts. The remaining 80 patients and 120 implants were classified into two groups: Group 1 (42 patients, 62 implants) received MT with periodic removal and decontamination of prosthetic components; Group 2 (38 patients, 58 implants) received MT without periodic removal and decontamination of prosthetic components. No statistical differences were found between the groups regarding PI, PPD, and REC. Group 1 presented a statistically significant higher number of sites with BOP (12.4% vs 6.2%). Marginal bone loss was statistically higher in Group 2 than in Group 1 (0.23 ± 0.6 mm vs 0.78 ± 0.3 mm). Intrasulcular levels of aMMP-8 were statistically higher in Group 1 than in Group 2. The supplemental application of periodic removal and decontamination of prosthetic components during MT had a significantly positive effect on the inflammatory status of peri-implant tissues.


Assuntos
Implantes Dentários , Humanos , Estudos Retrospectivos , Descontaminação , Índice de Placa Dentária
3.
J Imaging ; 10(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38248994

RESUMO

(1) The possibility of knowing information about the anatomy in advance, in particular the arrangement of the endodontic system, is crucial for successful treatment and for avoiding complications during endodontic therapy; the aim was to find a correlation between a minimally invasive and less stressful endodontic access on Ni-Ti rotary instruments, but which allows correct vision and identification of anatomical reference points, simplifying the typologies based on the shape of the pulp chamber in coronal three-dimensional exam views. (2) Based on the inclusion criteria, 104 maxillary molars (52 maxillary first molars and 52 maxillary second molars) were included in the study after 26 Cone Beam Computed Tomography (CBCT) acquisitions (from 15 males and 11 females). And linear measurements were taken with the CBCT-dedicated software for subsequent analysis. (3) The results of the present study show data similar to those already published about this topic. Pawar and Singh's simplified classification actually seems to offer a schematic way of classification that includes almost all of the cases that have been analyzed. (4) The use of a diagnostic examination with a wide Field of View (FOV) and low radiation dose represents an exam capable of obtaining a lot of clinical information for endodontic treatment. Nevertheless, the endodontic anatomy of the upper second molar represents a major challenge for the clinician due to its complexity both in canal shape and in ramification.

4.
Sci Prog ; 105(2): 368504221103763, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35656775

RESUMO

The aim of this study was to explain the mechanical differences between EdgeTaper Platinum (ETP) and ProTaper Gold (PTG) determining the transition temperatures and the composition of the alloy of ETP, since no data are present in literature. A total of 130 instruments were selected: 65 ETP F2 and 65 PTG F2. 20 instruments per type were submitted to each mechanical tests. The cyclic fatigue and torsional tests were performed at a pre-set temperature of 35 °C ± 1 °C. During the cyclic fatigue test, Time to fracture, number of cycles to fracture (NCF) and the fragment length (FL) were recorded. During the static torsional, Torque to Fracture (TtF) and FL were recorded. The fracture surface of 5 randomly selected fragments from each test was examined through a Scanning Electron Microscopy (SEM) and an EDX analysis was performed. 20 instruments per type were submitted to a bending test The force generated (grams) to bend each was recorded. Recorded data of mechanical and metallurgical tests were statistically analyzed using a one-way analysis of variance (ANOVA) test with significance set to a 95% confidence level. ETP F2 showed a higher cyclic fatigue resistance and bending ability than PTG F2, with a statistically significant difference (p < 0.05). PTG showed a higher torsional resistance with a statistically significant difference (p < 0.05). DSC analysis of 5 samples for each instrument type pointed out that the austenite finish temperature of PTG was higher than the ETP, respectively of 49.99 ± 3.31 (°C) and 38.92 ± 1.75 (°C). EDX analysis confirmed the near-equiatomic composition of the Ni-Ti alloys, with a presence of a third component recognized as rubidium in the ETP samples. ETP showed higher flexibility in comparison with PTG, despite the latter is characterized by a more martensitic characterization. since its Af temperature is higher than the ETP.


Assuntos
Endodontia , Temperatura Alta , Metalurgia , Ligas , Endodontia/instrumentação
5.
Clin Implant Dent Relat Res ; 24(5): 676-682, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35749154

RESUMO

AIM: To compare the clinical and radiographic conditions and the expression of pro-inflammatory cytokines in peri-implant crevicular fluid (PICF) at two-piece/bone level (TP/BL) versus one-piece/tissue level (OP/TL) single implants with a laser-microgrooved collar after at least 5 years of loading. MATERIALS AND METHODS: In total, 20 single TP/BL implants and 20 contralateral OP/TL implants, both with a laser-microgrooved collar surface, in 20 systemically and periodontally healthy subjects (12 males and 8 females, between the age of 36 and 64 [mean age of 49.7 ± 12.3 years]), were examined. Levels of IL-1ß, IL-1RA, IL-6, IL-8, IL-17, b-FGF, G-CSF, GM-CSF, IFN, MIP-1ß, TNF-α, and VEGF were assessed in PICF using the Bio-Plex 200 Suspension Array System. Plaque index (PI), probing depth (PD), bleeding on probing (BOP), and gingival recession (REC) were recorded. Radiographic crestal bone levels (CBL) were assessed at the mesial and distal aspects of the implant sites. RESULTS: The mean PI, PD, BOP, and REC values had no significant differences in either group. A higher mean value of CBL with statistical difference was detected for TP/BL compared with OP/TL implants. The levels of IL-1ß, IL-6, IL-8, GM-CSF, and MIP-1ß and TNF-α were higher at TP/BL implants than at OP/TL implants. However, only IL-1ß, IL-6, and TNF-α values presented significant differences between the groups. CONCLUSIONS: Although after 5 years of loading single TP/BL and OP/TL implants with a laser-microgrooved collar surface presented similar good clinical conditions, a higher proinflammatory state and higher crestal bone loss were detected for TP/BL implants.


Assuntos
Implantes Dentários , Adulto , Quimiocina CCL4 , Feminino , Fator Estimulador de Colônias de Granulócitos , Fator Estimulador de Colônias de Granulócitos e Macrófagos , Humanos , Proteína Antagonista do Receptor de Interleucina 1 , Interleucina-17 , Interleucina-6 , Interleucina-8 , Lasers , Masculino , Pessoa de Meia-Idade , Fator de Necrose Tumoral alfa , Fator A de Crescimento do Endotélio Vascular
6.
Diagnostics (Basel) ; 12(5)2022 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-35626197

RESUMO

In recent years, CBCT has proved to be extremely widely used and widespread in dentistry [...].

7.
Materials (Basel) ; 15(5)2022 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-35269168

RESUMO

Aim: The aim of the present study was to compare the direct and indirect cytotoxicity of a porcine dried acellular dermal matrix (PDADM) versus a porcine hydrated acellular dermal matrix (PHADM) in vitro. Both are used for periodontal and peri-implant soft tissue regeneration. Materials and methods: Two standard direct cytotoxicity tests­namely, the Trypan exclusion method (TEM) and the reagent WST-1 test (4-3-[4-iodophenyl]-2-[4-nitrophenyl]-2H-[5-tetrazolio]-1,3-benzol-desulphonated)­were performed using human primary mesenchymal stem cells (HPMSCs) seeded directly onto a PDADM and PHADM after seven days. Two standard indirect cytotoxicity tests­namely, lactate dehydrogenase (LTT) and MTT (3-[4,5-dimethyl-2-thiazolyl]-2,5-diphenyl-2H-tetrazoliumbromide)­were performed using HPMSCs cultivated in eluates from the matrices incubated for 0.16 h (10 min), 1 h, and 24 h in a serum-free cell culture medium. Results: The WST and the TEM tests revealed significantly lower direct cytotoxicity values of HPMSCs on the PHADM compared with the PDADM. The indirect cytotoxicity levels were low for both the PHADM and PDADM, peaking in short-term eluates and decreasing with longer incubation times. However, they were lower for the PHADM with a statistically significant difference (p < 0.005). Conclusions: The results of the current study demonstrated a different biologic behavior between the PHADM and the PDADM, with the hydrated form showing a lower direct and indirect cytotoxicity.

8.
Diagnostics (Basel) ; 12(2)2022 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-35204626

RESUMO

In recent years, improvements in imaging techniques have profoundly facilitated the diagnosis of pathologies of the maxillofacial district [...].

9.
Materials (Basel) ; 15(4)2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35207969

RESUMO

This preliminary study aims to evaluate the efficacy of an autologous dentin graft in preventing periodontal defects after impacted or semi-impacted lower third molars' (M3) surgical extraction. For this purpose, radiographic and periodontal evaluation of post-extractive sockets were performed. Ten patients were enrolled in the study: twenty M3 extraction sockets were treated with a split-mouth modality. After tooth extraction, the experimental sites were filled with autologous dentin graft obtained by the extracted M3, while the control sites were filled with blood clot alone. Flaps were closed by first intention to ensure the stability of the wounds. Post-extractive sites were monitored at days 15, 90 and 180. The healing was not affected by any complications associated with the use of the autologous dentine graft in all cases. The measurements recorded at six months showed a reduction of the probing pocket depth distal to the second lower molar (M2) at both surgical sites, with a greater reduction observed at the experimental sites. Radiographic evaluation also showed a greater amount of bone gain at the grafted sites compared to the control sites. The results of this preliminary study suggest that autologous dentin grafts can be useful in preventing the formation of periodontal defects distal to M2 after M3 surgical extraction.

10.
J Pers Med ; 12(1)2022 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-35055373

RESUMO

OBJECTIVES: The aim of this retrospective study was to analyze peri-implant marginal bone loss levels/rates and peri-implant sulcular fluid levels/rates of metalloproteinase-8 in three timeframes (6 months post-surgery-restoration delivery (T0)-and 6 (T6) and 24 (T24)-months post-loading) and to evaluate if there is a correlation between peri-implant sulcular fluid levels of metalloproteinase-8 and peri-implant marginal bone loss progression. MATERIALS AND METHODS: Two cohorts of patients undergoing implant surgery between January 2017 and January 2019 were selected in this retrospective study. A total of 39 patients received 39 implants with a laser-microtextured collar surface, and 41 subjects received 41 implants with a machined/smooth surface. For each patient, periapical radiographs and a software package were used to measure marginal bone loss rates. Implant fluid samples were analyzed by an enzyme-linked immunosorbent assay (ELISA) test. The modified plaque index, probing depth, and bleeding on probing were also recorded. RESULTS: High marginal bone rates at T24 were strongly associated with elevated rates between T0 and T6. The levels of metalloproteinase-8 were significantly more elevated around implants with marginal bone loss, in relation to implants without marginal bone loss. Marginal bone loss (MBL) rates at 24 months were associated with initial bone loss rates and initial levels of metalloproteinase-8. CONCLUSIONS: Peri-implant marginal bone loss progression is statistically correlated to peri-implant sulcular fluid levels of metalloproteinase-8. Moreover, the initial high levels of marginal bone loss and metalloproteinase-8 can be considered as indicators of the subsequent progression of peri-implant MBL: implants with increased marginal bone loss rates and metalloproteinase-8 levels at 6 months after loading are likely to achieve additional marginal bone loss values.

11.
Bioengineering (Basel) ; 9(1)2022 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-35049739

RESUMO

Since there are no reviews of the literature on this theme, the aim of this narrative review is to summarize the metallurgical tests used in endodontics, pointing out their functional use and their pros and cons and giving readers a user-friendly guide to serve as an orientation aid in the plethora of metallurgical tests. With this purpose, a literature search for articles published between January 2001 and December 2021 was conducted, using the electronic database PubMed to collect all published articles regarding the metallurgical tests used in endodontics for the evaluation of NiTi rotary instruments. The search was conducted using the following keywords: "metallurgy", "differential scanning calorimetry" (DSC), "X-ray diffraction" (XRD), "atomic force microscopy" (AFM), "energy-dispersive X-ray spectroscopy" (EDS), "focused ion beam analysis" (FIB) and "Auger electron spectroscopy" (AES) combined with the term "endodontics" or "NiTi rotary instruments". Considering the inclusion and exclusion criteria, of the 248 articles found, only 81 were included in the narrative review. According to the results, more than 50% of the selected articles were published in one of the two most relevant journals in endodontics: International Endodontic Journal (22.2%) and Journal of Endodontics (29.6%). The most popular metallurgical test was DSC, with 43 related articles, followed by EDS (33 articles), AFM (22 articles) and XRD (21 articles). Few studies were conducted using other tests such as FIB (2 articles), micro-Raman spectroscopy (4 articles), metallographic analysis (7 articles) and Auger electron spectroscopy (2 articles).

12.
Methods Protoc ; 5(1)2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-35076562

RESUMO

BACKGROUND: The most used types of retention of implant-supported prostheses are screw-retained or cement-retained restorations. The advantages and disadvantages of both have been identified by various authors over the years. However, cement-retained implant crowns and fixed partial dentures are among the most used types of restorations in implant prostheses, due to their aesthetic and clinical advantages. When cemented prostheses are made on implants, the problem of cement residues is important and often associated with biological implant pathologies. The objective of this research was to establish to what extent the techniques to reduce excess cement really affect the volume of cement residues. MATERIALS AND METHODS: This review was written following the PRISMA statement; a detailed search was carried out in three different electronic databases-PubMed, Scopus, and Cochrane Library. The inclusion criteria were prospective clinical studies, with at least 10 participants per group, and with at least 6 months of the follow-up period. RESULTS: There have been many proposals for techniques supposed to reduce the amount of excess cement in the peri-implant sulcus and on the prosthetic components, but of these, which are exceptional in their in vitro capabilities, very few have been clinically validated, and this represents the real limitation and a great lack of knowledge regarding this topic. Three articles met the inclusion criteria, which were analyzed and compared, to obtain the information necessary for the purposes of the systematic review. DISCUSSION: Extraoral cementation can reduce the excess cement, which, after a normal excess removal procedure, is, nevertheless, of such size that it does not affect the possibility of peri-implant pathologies developing. All these studies concluded that a small amount of cement residue is found in the gingival sulcus, and using eugenol-free oxide cements, the residues were only deposited on the metal surfaces, with a better peri-implant tissues health. CONCLUSION: Despite the limitations of this study, it was possible to carefully analyze these characteristics and obtain valuable suggestions for daily clinical practice. Resinous cements are considered, due to the free monomers present in them, toxic for the soft tissues. The provisional zinc-oxide cements, also eugenol-free, represent the ideal choice. The different grades of retentive forces provided by these cements do not seem to have clinical effects on the decementation of restorations.

13.
Clin Oral Implants Res ; 33(1): 94-104, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34624157

RESUMO

OBJECTIVES: To compare gingival tissue healing at surgically manipulated periodontal sites and at sites receiving implants and healing abutments with machined (MS) vs laser-microtextured (LMS) surface placed with one-stage protocol. MATERIAL AND METHODS: Twenty-four non-smoking patients each received two implants with one-stage protocol in a split-mouth design on the same jaw. In each patient, one implant with a MS collar and one immediate healing abutment with a MS, and one implant with a LMS collar and one immediate healing abutment with a LMS were used. Soft tissues healing at surgically manipulated periodontal tissues (T+) and at non-surgically manipulated periodontal tissues (T-) at MS implant sites and at LMS implant sites were compared by means of clinical and biochemical parameters at baseline and at 1-2-3-4-6-8 and 12 weeks. RESULTS: PD and BoP mean values were statistically higher in MS than LMS implant sites (p<0.05). During early healing phase (1-4 weeks), MS and LMS peri-implant tissues and periodontal tissues at T(+) showed no statistically significant difference in crevicular fluid volume changes (p>0.05). Between 6 and 12 weeks, compared with T(+), no statistically significant difference in crevicular fluid volume and IL-6 and IL-1ß concentrations was noted in LMS implant sites (p>0.05), while statistically significantly higher mean values were noted in MS implant sites (p<0.05). CONCLUSIONS: Compared with T(+) and T(-), both MS and LMS implant sites presented a higher pro-inflammatory state in the early phase after surgery (1-4 weeks). At 12 weeks, only MS implant sites kept a higher pro-inflammatory state, while at LMS implant sites, it becomes similar to T(+) and T(-).


Assuntos
Implantes Dentários , Interleucina-6 , Biometria , Humanos , Lasers , Boca
14.
Bioengineering (Basel) ; 8(12)2021 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-34940371

RESUMO

Since the introduction of Nickel-Titanium alloy as the material of choice for the manufacturing of endodontic rotary instruments, the success rate of the root canal therapies has been significantly increased. This success mainly arises from the properties of the Nickel-Titanium alloy: the biocompatibility, the superelasticity and the shape memory effect. Those characteristics have led to a reduction in time of endodontic treatments, a simplification of instrumentation procedures and an increase of predictability and effectiveness of endodontic treatments. Nevertheless, the intracanal separation of Nickel-Titanium rotary instruments is still a major concern of endodontists, with a consequent possible reduction in the outcome rate. As thoroughly demonstrated, the two main causes of intracanal separation of endodontic instruments are the cyclic fatigue and the torsional loads. As results, in order to reduce the percentage of intracanal separation research and manufacturers have been focused on the parameters that directly or indirectly influence mechanical properties of endodontic rotary instruments. This review describes the current state of the art regarding the Nickel-Titanium alloy in endodontics, the mechanical behavior of endodontic rotary instruments and the relative stresses acting on them during intracanal instrumentation, highlighting the limitation of the current literature.

15.
J Imaging ; 7(11)2021 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-34821869

RESUMO

(1) Background: the frequency with which diagnostic tests are prescribed with exposure to ionizing radiation, a cause of biological damage, has been studied, and with much more attention, patients are subjected to these diagnostic tests for diagnosis and follow-up. This review aimed, given the recent developments of this technology, to evaluate the possible use of ultrasound in different branches of dentistry. The possibility of applying ionizing-radiation-free diagnostic exams in dentistry, overcoming the limits of this application, has led scientific research in this area to obtain interesting results that bode well for the future. (2) Methods: a search for articles on the application of ultrasounds in dentistry was performed using the PubMed electronic database. (3) Results: only 32 studies were included, and these clearly stated that this examination is widely usable and in great progress. (4) Conclusions: regarding the modern application techniques of this diagnostic test, it is essential to consider technological evolution as an objective to reduce the damage and side effects of necessary diagnostic tests. The use of ultrasound in dentistry can represent a valid radiation-free alternative, in certain contexts, to the other most used exams.

16.
Materials (Basel) ; 14(21)2021 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-34771850

RESUMO

The aim of this study was to assess the role of the crystallographic phase of Nickel-titanium (NiTi) rotary instruments in determining their torsional resistance during different bending conditions, such as different degrees and angles of curvature. 200 F-One 20.04 instruments (Fanta Dental, Shanghai, China) were used, 100 austenitic instruments and 100 martensitic instruments. Each group was divided in 5 subgroups according to the different bending conditions (straight canal, 90° or 60° of curvature degrees and 3 mm or 5 mm of radius of curvature). The static torsional test was performed by using a device composed of an electric motor capable of recording torque values (N·cm); a vice used to secure the instruments at 3 mm from the tip; and artificial canals, which allow instruments to remain flexed during test. Each instrument was rotated at 500 rpm with a torque limit set to 5.5 Ncm until its fracture. Torque at Fracture (TtF) was registered. A scanning electron microscopy (SEM) observation was conducted. The collected data confirm that an increase in the angle of curvature and a decrease in the radius of curvature of the artificial canals lead to an increase of TtF values with a statistically significant difference (p < 0.05), both in the austenitic and martensitic groups. Regarding the comparison between austenitic and martensitic groups in the same bending condition, a statistically significant difference was found only when the torsional test was performed in the canals with the degrees of curvature of 90° and the radius of curvature of 3 mm and 5 mm, with the austenitic instruments showing a higher TtF than the martensitic ones. In conclusion, it can be stated that the crystallographic phase influences the maximum torque at fracture when the instruments are subjected to severe bending and that the radius of curvature significantly influences their torsional resistance.

17.
J Imaging ; 7(5)2021 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-34460671

RESUMO

This narrative review aims to evaluate the current evidence for the application of magnetic resonance imaging (MRI), a radiation-free diagnostic exam, in some fields of dentistry. BACKGROUND: Radiographic imaging plays a significant role in current first and second level dental diagnostics and treatment planning. However, the main disadvantage is the high exposure to ionizing radiation for patients. METHODS: A search for articles on dental MRI was performed using the PubMed electronic database, and 37 studies were included. Only some articles about endodontics, conservative dentistry, implantology, and oral and craniofacial surgery that best represented the aim of this study were selected. RESULTS: All the included articles showed that MRI can obtain well-defined images, which can be applied in operative dentistry. CONCLUSIONS: This review highlights the potential of MRI for diagnosis in dental clinical practice, without the risk of biological damage from continuous ionizing radiation exposure.

18.
Eur J Dent ; 15(4): 776-781, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34388831

RESUMO

The purpose of this review was to analyze how the retraction and protection of lingual flap (LF+) could influence the incidence of lingual nerve injury (LNI) during third molar extraction, as compared with protocols that do not involve handling of lingual tissue (LF). A literature review was performed from the "Medline" and "Scopus" medical databases, using the keywords "lingual nerve" and "third molar surgery." From the selected articles, the mean values for transitory and permanent LNI's incidence were elaborated, taking into account the group treated with LF+ technique and the group treated with LF technique. Of 480 articles, 11 studies were included in the review. The LF+ group counted 3,866 surgeries and it resulted in a transitory LNI's mean incidence of 2.98 ± 0.03% and a mean incidence of 0.1 ± 0.003% for permanent LNI. The LF group counted 5,938 surgeries with, respectively, 1.92 ± 0.02 and 0.49 ± 0.006% of transitory and permanent LNI's incidence mean values. The results of this study suggest that the application of LF+ techniques reduces the risk of damage and injuries of lingual nerve.

19.
J Contemp Dent Pract ; 22(4): 427-434, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34267014

RESUMO

AIM: The aim of this systemic review is to investigate these parameters by analyzing the characteristics of fractured instruments to determine which is the most relevant mechanical stress that induces intracanal separation in vivo. BACKGROUND: The fracture of nickel-titanium (Ni-Ti) instruments is a result of flexural fatigue and torsional fatigue. An electronic search was conducted in MEDLINE database, Web of Science, and Cochrane following preferred reporting items for systematic reviews and meta-analyses guidelines. Data were collected and the key features from the included studies were extracted. Overview quality assessment questionnaire scoring assessed the quality of the articles. A total of 12 articles were selected, where the lowest score was 13. REVIEW RESULTS: Considering Ni-Ti rotary instruments, this overall evaluation comprehends 939 broken instruments with an incidence of fracture of 5%. Out of the 12 selected articles, 10 studies revealed that flexural failure was the predominant mode (range of 62-92%). It appears that motion plays an important role when it comes to mechanisms of fracture. The majority of defects found in hand-operated instruments were in the form of torsional failure. Although the major cause of separation of rotary instruments is flexural fatigue, smaller instruments show more torsional fracture than the larger instruments. The average fragment length was found to be 2.5 mm and 3.35 mm, respectively, for torsional failure and flexural failure. The risk of bias depends on fractographic analysis. CONCLUSION: Flexural fatigue is the predominant mode of fracture in rotary Ni-Ti instruments. The type of motion and size of the instrument seem to affect the mechanism of fracture. Fragment length may show a strong association with the type of fracture mechanism. CLINICAL SIGNIFICANCE: This systemic review found that flexural fatigue is the most relevant mechanical stress that induces intracanal separation in vivo. Moreover, in clinical practice, the fragment length might be an excellent indicator of the type of fracture.


Assuntos
Níquel , Titânio , Ligas Dentárias , Instrumentos Odontológicos , Desenho de Equipamento , Falha de Equipamento , Incidência , Preparo de Canal Radicular , Estresse Mecânico , Torção Mecânica
20.
Materials (Basel) ; 14(13)2021 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-34279315

RESUMO

Previously published studies have investigated the influence of instrument access on cyclic fatigue resistance. However, no studies have evaluated the relationship between angulated access and torsional resistance. The aim of this study was to investigate the influence of the angle of access on the torsional resistance of endodontic instruments. One hundred and eighty instruments were selected: 90 F-One Blue 25/04 and 90 HeroShaper 25/04 instruments. Three subgroups (n = 30) for each instrument type (A and B) were established according to the angle of insertion of the instruments inside the artificial canal (0°, 10° and 20°). The tests were performed using a custom-made device consisting of the following: a motor that can record torque values of 0.1 s; interchangeable stainless-steel canals with different curvature (0°, 10° and 20°) that allow the instrument's angulated insertion and keep it flexed during testing procedures; and a vise used to secure the instrument at 3 mm from the tip. Torque limit was set to 5.5 Ncm, and each instrument was rotated at 500 rpm until fracture occurred. Torque to fracture (TtF) was registered by the endodontic motor, and the fragment length (FL) was measured with a digital caliper. Fractographic analysis was performed using a scanning electron microscopy (SEM) evaluation to confirm the cause of failure. TtF values and fragment length (FL) values were statistically analyzed using one-way analysis of variance (ANOVA) test and the Bonferroni correction for multiple comparisons across the groups with significance set to a 95% confidence level. Regarding the F-One Blue instruments, the results showed a higher TtF for group A3 (20°) than for group A1 (0°) and group A2 (10°), with a statistically significant difference between group A3 and the other two groups (p < 0.05), whereas no statistically significant difference was found between group A1 and group A2 (p > 0.05). Regarding the HeroShaper instrument, the results showed the highest TtF for group B3, with a statistically significant difference between the three subgroups B1, B2 and B3 (p < 0.05). The results showed that the torsional resistance increases as the angle of instrument access increases with a varying intensity, according to the crystallographic phase of the instrument selected.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...