Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomed Opt ; 20(11): 115001, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26524677

RESUMO

In this work, we have tested the optimal estimation (OE) algorithm for the reconstruction of the optical properties of a two-layered liquid tissue phantom from time-resolved single-distance measurements. The OE allows a priori information, in particular on the range of variation of fit parameters, to be included. The purpose of the present investigations was to compare the performance of OE with the Levenberg­Marquardt method for a geometry and real experimental conditions typically used to reconstruct the optical properties of biological tissues such as muscle and brain. The absorption coefficient of the layers was varied in a range of values typical for biological tissues. The reconstructions performed demonstrate the substantial improvements achievable with the OE provided a priori information is available. We note the extreme reliability, robustness, and accuracy of the retrieved absorption coefficient of the second layer obtained with the OE that was found for up to six fit parameters, with an error in the retrieved values of less than 10%. A priori information on fit parameters and fixed forward model parameters clearly improves robustness and accuracy of the inversion procedure.


Assuntos
Luz , Modelos Biológicos , Nefelometria e Turbidimetria/métodos , Refratometria/métodos , Espalhamento de Radiação , Tomografia Óptica/métodos , Algoritmos , Animais , Simulação por Computador , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Óptica/instrumentação
2.
Biomed Opt Express ; 6(7): 2609-23, 2015 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-26203385

RESUMO

The in-vivo optical properties of the human head are investigated in the 600-1100 nm range on different subjects using continuous wave and time domain diffuse optical spectroscopy. The work was performed in collaboration with different research groups and the different techniques were applied to the same subject. Data analysis was carried out using homogeneous and layered models and final results were also confirmed by Monte Carlo simulations. The depth sensitivity of each technique was investigated and related to the probed region of the cerebral tissue. This work, based on different validated instruments, is a contribution to fill the existing gap between the present knowledge and the actual in-vivo values of the head optical properties.

3.
J Biomed Opt ; 19(8): 086012, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25121480

RESUMO

The nEUROPt protocol is one of two new protocols developed within the European project nEUROPt to characterize the performances of time-domain systems for optical imaging of the brain. It was applied in joint measurement campaigns to compare the various instruments and to assess the impact of technical improvements. This protocol addresses the characteristic of optical brain imaging to detect, localize, and quantify absorption changes in the brain. It was implemented with two types of inhomogeneous liquid phantoms based on Intralipid and India ink with well-defined optical properties. First, small black inclusions were used to mimic localized changes of the absorption coefficient. The position of the inclusions was varied in depth and lateral direction to investigate contrast and spatial resolution. Second, two-layered liquid phantoms with variable absorption coefficients were employed to study the quantification of layer-wide changes and, in particular, to determine depth selectivity, i.e., the ratio of sensitivities for deep and superficial absorption changes. We introduce the tests of the nEUROPt protocol and present examples of results obtained with different instruments and methods of data analysis. This protocol could be a useful step toward performance tests for future standards in diffuse optical imaging.


Assuntos
Algoritmos , Encéfalo/citologia , Análise de Falha de Equipamento/métodos , Interpretação de Imagem Assistida por Computador/métodos , Microscopia/instrumentação , Tomografia Óptica/instrumentação , Desenho de Equipamento , Europa (Continente) , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Biomed Opt ; 19(7): 076011, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25023415

RESUMO

We present the experimental implementation and validation of a phantom for diffuse optical imaging based on totally absorbing objects for which, in the previous paper [J. Biomed. Opt.18(6), 066014, (2013)], we have provided the basic theory. Totally absorbing objects have been manufactured as black polyvinyl chloride (PVC) cylinders and the phantom is a water dilution of intralipid-20% as the diffusive medium and India ink as the absorber, filled into a black scattering cell made of PVC. By means of time-domain measurements and of Monte Carlo simulations, we have shown the reliability, the accuracy, and the robustness of such a phantom in mimicking typical absorbing perturbations of diffuse optical imaging. In particular, we show that such a phantom can be used to generate any absorption perturbation by changing the volume and position of the totally absorbing inclusion.


Assuntos
Imagem Óptica/instrumentação , Imagens de Fantasmas , Modelos Biológicos , Método de Monte Carlo
5.
J Opt Soc Am A Opt Image Sci Vis ; 31(3): 460-9, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-24690640

RESUMO

In this paper, after a critical review of the literature, we present two forward solvers and a new methodology for description of photon migration in the presence of totally absorbing inclusions embedded in diffusive media in both time and CW domains. The first forward solver is a heuristic approach based on a higher order perturbation theory applied to the diffusion equation (DE) [denoted eighth-order perturbation theory (EOPT)]. The second forward solver [denoted eighth-order perturbation theory with the equivalence relation (EOPTER) ] is obtained by combining the EOPT solver with the adoption of the equivalence relation (ER) [J. Biomed. Opt.18, 066014 (2013)]. These forward solvers can possibly overcome some evident limitations of previous approaches like the theory behind the so-called banana-shape regions or exact analytical solutions of the DE in the presence of highly or totally absorbing inclusions. We also propose the ER to reformulate the problem of a totally absorbing inclusion in terms of another inclusion having a finite absorption contrast and a re-scaled volume. For instance, we have shown how this approach can indeed be used to simulate black inclusions with the Born approximation. By means of comparisons with the results of Monte Carlo simulations, we have shown that the EOPTER solver can model totally absorbing inclusions with an error smaller than about 10%, whereas the EOPT solver shows an error smaller than about 20%, showing a performance largely better than that observed with solvers proposed previously.


Assuntos
Método de Monte Carlo , Fenômenos Ópticos , Fótons , Absorção , Difusão , Fatores de Tempo
6.
Appl Opt ; 51(30): 7176-82, 2012 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-23089769

RESUMO

Intralipid 20% was recently suggested as a diffusive reference standard for tissue simulating phantoms. In this work, we extend previously obtained results to other fat emulsions, specifically Intralipid 10%, Intralipid 30%, Lipovenoes 10%, Lipovenoes 10% PhosphoLipid Reduced, Lipovenoes 20%, Lipofundin S 10%, and Lipofundin S 20%. Of particular importance for practical applications, our measurements carried out at a wavelength of 751 nm show the following features. First, these products show high stability and small batch-to-batch variations in their diffusive optical properties, similar to Intralipid 20%. Second, the absorption coefficient of Intralipid, Lipovenoes, and Lipofundin S are very similar and their measured values are within the experimental errors; moreover the reduced scattering coefficient of Intralipid 20%, Lipovenoes 20%, and Lipofundin S 20% are similar and their measured values are within 5%. Third, the reduced scattering coefficient of Intralipid 10% and Intralipid 30% can be scaled from that of Intralipid 20% with an error of 9% and 2%, respectively. A similar scaling property is valid for Lipovenoes and Lipofundin S. We have verified that this scaling property depends on the composition of the fat emulsions: If the ingredients exactly scale with the concentration then the reduced scattering coefficient almost exactly scale as well.


Assuntos
Emulsões Gordurosas Intravenosas/química , Imagens de Fantasmas , Algoritmos , Emulsões Gordurosas Intravenosas/normas , Humanos , Luz , Nefelometria e Turbidimetria/métodos , Nefelometria e Turbidimetria/normas , Tamanho da Partícula , Padrões de Referência , Reprodutibilidade dos Testes , Espalhamento de Radiação , Espectrofotometria/métodos , Espectrofotometria/normas
7.
Nanoscale Res Lett ; 7(1): 96, 2012 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-22297089

RESUMO

The full characterization of the optical properties of nanofluids consisting of single-wall carbon nanohorns of different morphologies in aqueous suspensions is carried out using a novel spectrophotometric technique. Information on the nanofluid scattering and absorption spectral characteristics is obtained by analyzing the data within the single scattering theory and validating the method by comparison with previous monochromatic measurements performed with a different technique. The high absorption coefficient measured joint to the very low scattering albedo opens promising application perspectives for single-wall carbon nanohorn-based fluid or solid suspensions. The proposed approximate approach can be extended also to other low-scattering turbid media.PACS: 78.35.+c Brillouin and Rayleigh scattering, other light scattering; 78.40.Ri absorption and reflection spectra, fullerenes and related materials; 81.05.U- carbon/carbon-based materials; 78.67.Bf optical properties of low-dimensional, mesoscopic, and nanoscale materials and structures, nanocrystals, nanoparticles, and nanoclusters.

8.
Biomed Opt Express ; 2(8): 2265-78, 2011 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-21833363

RESUMO

The calibration of optical tissue-simulating phantoms remains an open question in spite of the many techniques proposed for accurate measurements of optical properties. As a consequence, a reference phantom with well known optical properties is still missing. As a first step towards a reference phantom we have recently proposed to use dilutions of Intralipid 20%. In this paper we discuss a matter that is commonly ignored when dilutions are prepared, i.e., the possibility of deviations from the simple linear relationships between the optical properties of the dilution and the Intralipid concentration due to the effects of dependent scattering. The results of an experimental investigation showed that dependent scattering does not affect absorption. As for the reduced scattering coefficient the effect can be described adding a term proportional to the square of the concentration. However, for concentrations of interest for tissue optics deviations from linearity remain within about 2%. The experimental investigation also showed that the microphysical properties of Intralipid are not affected by dilution. These results show the possibility to easily obtain a liquid diffusive phantom whose optical properties are known with error smaller than about 1%. Due to the intrinsic limitations of the different techniques proposed for measuring the optical properties it seems difficult to obtain a similar accuracy for solid phantoms.

9.
Nanoscale Res Lett ; 6(1): 282, 2011 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-21711795

RESUMO

In the present work, we investigated the scattering and spectrally resolved absorption properties of nanofluids consisting in aqueous and glycol suspensions of single-wall carbon nanohorns. The characteristics of these nanofluids were evaluated in view of their use as sunlight absorber fluids in a solar device. The observed nanoparticle-induced differences in optical properties appeared promising, leading to a considerably higher sunlight absorption with respect to the pure base fluids. Scattered light was found to be not more than about 5% with respect to the total attenuation of light. Both these effects, together with the possible chemical functionalization of carbon nanohorns, make this new kind of nanofluids very interesting for increasing the overall efficiency of the sunlight exploiting device. PACS: 78.40.Ri, 78.35.+c, 78.67.Bf, 88.40.fh, 88.40.fr, 81.05.U.

10.
Opt Express ; 18(26): 26854-65, 2010 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-21196962

RESUMO

The optical properties of India ink, an absorber often used in preparation of tissue simulating phantoms, have been investigated at visible and near infrared wavelengths. The extinction coefficient has been obtained from measurements of collimated transmittance and from spectrophotometric measurements, the absorption coefficient from multidistance measurements of fluence rate in a diffusive infinite medium with small concentrations of added ink. Measurements have been carried out on samples of India ink from five different brands, and for some brands also from different batches. As also reported in previously published papers the results we have obtained showed large inter-brand and inter-batch variations for both the absorption and the extinction coefficient. On the contrary, our results showed small variations for the ratio between the absorption and the extinction coefficient. The albedo is therefore similar for all samples: The values averaged over all samples investigated were 0.161, 0.115, and 0.115 at λ = 632.8, 751, and 833 nm respectively, with maximum deviations of 0.044, 0.019, and 0.035. These results indicate that, using the values we have obtained for the albedo, it should be possible to obtain with uncertainty smaller than about 4% the absorption coefficient of a sample of unknown ink from simple measurements of extinction coefficient. A similar accuracy is not easily obtained with the complicated procedures necessary for measurements of absorption coefficient.


Assuntos
Materiais Biomiméticos/química , Carbono/química , Nefelometria e Turbidimetria/métodos , Imagens de Fantasmas , Refratometria/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...