Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
J Prosthet Dent ; 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38307751

RESUMO

STATEMENT OF PROBLEM: Disinfection is an important factor in preserving facial prostheses and maintaining tissue health. However, whether disinfection with ultraviolet C is an effective disinfection method is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the effectiveness of irradiation with different exposure durations of an ultraviolet-C light-emitting diode in the disinfection of the silicone (A-588-1; Factor II) used in facial prostheses. MATERIAL AND METHODS: A total of 216 specimens were prepared, contaminated by multispecies biofilm, and divided into 9 groups (n=24) for different treatments: chlorhexidine 0.12% (G CHG), ultraviolet-C light-emitting diode for 5 minutes (G UVC5), ultraviolet-C light-emitting diode for 10 minutes (G UVC10), ultraviolet-C light-emitting diode for 20 minutes (G UVC20), their respective untreated controls (Gcontrol CHG, Gcontrol UVC5, Gcontrol UVC10, Gcontrol UVC20), and dimethyl sulfoxide (G DMSO) as the negative control. Cell viability was measured by using the methyl tetrazolium salt (MTT) method. Two statistical analyses were performed. First, a 2×3 ANOVA was carried out to compare the control groups (Gcontrol UVC5, Gcontrol UVC10, and Gcontrol UVC20) and the experimental groups of UV-C LED light with different exposure durations (G UVC5, G UVC10, and G UVC20). The second analysis was performed using generalized linear models to compare the optical density of the groups (G UVC5, G UVC10, G UVC20, G CHG, and G DMSO). RESULTS: Cell viability results demonstrated a microbial reduction after exposure to the ultraviolet-C light-emitting diode for 20 minutes (G UVC20) compared with untreated controls (P<.05). The 5- and 10-minute exposures were statistically similar to their respective control groups (P>.05). The 20 minutes exposure had the lowest average optical density value, being statistically different from the 5-minute exposure (P<.05). A 20-minute exposure to the ultraviolet-C light-emitting diode (G UVC20) was similarly effective when compared with the standard disinfection treatment (G CHG) and dimethyl sulfoxide (G DMSO) (P>.05). CONCLUSIONS: Irradiation with an ultraviolet-C light-emitting diode for 20 minutes decreased the in vitro microbial cell viability on the medical silicone used in facial prostheses.

2.
Medicina (Kaunas) ; 59(7)2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37512000

RESUMO

Background: The objective of this study was to evaluate the load transmitted to the peri-implant bone by seven different restorative materials in single-unit rehabilitations with morse taper implants using a strain gauge. Materials: In a polyurethane block that simulated type III bone, a morse taper platform implant was installed (3.5 × 11 mm) in the center and 1 mm below the test base surface, and four strain gauges were installed around the implant, simulating the mesial, distal, buccal and lingual positions. Seven similar hybrid abutment crowns were crafted to simulate a lower premolar using different materials: 1-PMMA; 2-glass ceramic over resin matrix; 3-PEEK + lithium disilicate; 4-metal-ceramic; 5-lithium disilicate; 6-zirconia + feldspathic; 7-monolithic zirconia. All groups underwent axial and oblique loads (45 degrees) of 150 N from a universal testing machine. Five measurements (n = 5) were performed with each material and for each load type; the microdeformation data underwent statistical analysis. The data were obtained in microdeformation (µÎµ), and the significance level was set at p ≤ 0.05. Results: There was no statistically significant difference in the evaluation among the materials under either the axial load or the oblique load at 45 degrees. In turn, in the comparison between axial load and oblique load, there was a difference in load for all materials. Conclusion: The restorative material did not influence the load transmitted to the bone. Furthermore, the load transmitted to the bone was greater when it occurred obliquely at 45° regardless of the material used. In conclusion, it appeared that the different elastic modulus of each material did not influence the load transmission to the peri-implant bone.


Assuntos
Coroas , Zircônio , Humanos
3.
J Prosthet Dent ; 129(4): 630-636, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34362565

RESUMO

STATEMENT OF PROBLEM: Facial scanning systems have been developed as auxiliary tools for diagnosis and planning in dentistry. However, little is known about the trueness of these free software programs and apps for facial scanning. PURPOSE: The purpose of this in vitro study was to evaluate the trueness of 3D facial scanning by using Bellus3D and +ID ReCap Photo. MATERIAL AND METHODS: A mannequin head was used as the master model. The control group was created by scanning the mannequin head with a noncontact structured blue light 3D scanner (ATOS Core). Two facial scanning methods were used for the experimental groups: a facial scanning app (FaceApp) and the Plus identity photogrammetry methodology (ReCap Photo). In both methods, image capturing was performed under the same natural lighting conditions with a smartphone (iPhone X) calibrated with an app. Trueness was assessed from the 3D measurement error, which was calculated with a 3D mesh analysis software program (GOM Inspect). Two comparison groups were created: ATOS versus Bellus3D (B3D) and ATOS versus +ID with ReCap Photo (+IDRP). The results were statistically evaluated by using the Shapiro-Wilk and paired t tests (α=.05). RESULTS: B3D had a greater error than +IDRP in measuring the regions of the upper and lower lips, nose, and mentum (P<.01). This error was statistically higher for +IDRP (P<.01) in the right face area, but the left face area showed no statistically significant difference between the evaluated scanning methods (P=.93). The 3D global trueness of B3D was 0.34 ±0.14 mm, and that of +IDRP was 0.28 ±0.06 mm. CONCLUSIONS: Both methods evaluated in this study provided a 3D model of the face with clinically acceptable trueness and should be reliable tools for planning esthetic restorations.


Assuntos
Estética Dentária , Imageamento Tridimensional , Nariz , Lábio , Software , Desenho Assistido por Computador , Técnica de Moldagem Odontológica
4.
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1431044

RESUMO

Abstract Bitemark analysis is a challenging procedure in the field of criminal case investigation. The unique characteristics of dentition are used to find the best match between the existing patterned injury and the suspected perpetrator in bitemark identification. Bitemark analysis accuracy can be influenced by various factors, including biting pressure, tooth morphology, skin elasticity, dental cast duplication, timing, and image quality. This review article discusses the potential of a smartphone camera as an alternative method for 3D bitemark analysis. Bitemark evidence on human skin and food should be immediately recorded or duplicated to retrieve long-lasting proof, allowing for a sufficient examination period. Various studies utilizing two-dimensional (2D) and three-dimensional (3D) technologies have been developed to obtain an adequate bitemark analysis. 3D imaging technology provides accurate and precise analysis. However, the currently available method using an intraoral scanner (IOS) requires high-cost specialized equipment and a well-trained operator. The numerous advantages of monoscopic photogrammetry may lead to a novel method of 3D bitemark analysis in forensic odontology. Smartphone cameras and monoscopic photogrammetry methodology could lead to a novel method of 3D bitemark analysis with an efficient cost and readily available equipment.


Assuntos
Mordeduras Humanas/diagnóstico por imagem , Fotogrametria/instrumentação , Smartphone , Odontologia Legal , Reconhecimento de Identidade , Antropologia Forense , Imageamento Tridimensional/métodos , Odontometria
5.
J Craniofac Surg ; 33(5): e482-e488, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35758431

RESUMO

ABSTRACT: Surgical treatment of head and neck cancer causes severe tissue loss, therefore, deformities and psychosocial consequences. In cases involving orbit exenteration, satisfactory reconstruction can only be achieved with prosthetic replacement, despite successful reconstructive plastic surgery. Extraoral implants, 3D scanning, and prototyping technologies have contributed to increase satisfactory aesthetic results of oculofacial prosthesis. However, to achieve prosthetic rehabilitation refinement, patients' biological tissues have been treated with injectable cosmetic adjuncts methods as complements to results. This study aimed to describe the use of botulinum toxin type A, hyaluronic acid, and calcium hydroxyapatite previously to oculofacial prostheses manufacturing, in 5 oncologic patients of a rehabilitation unit. Outcomes produced by additional cosmetic methods on tissues, prostheses planning, and overall facial rehabilitation were observed and registered by photographs. Botulinum toxin type A, hyaluronic acid, and calcium hydroxyapatite has shown to be useful in improving asymmetries, volumizing surgical depressions and dissembling atrophic scars. Presenting an additional resource to improve overall results, enabling the manufacturing of smaller, thinner, and better-fitting oculofacial prostheses. Limitations as chronic infection and necrosis episodes, related to filler injection into previously irradiated sites, were described. The temporary effect of the materials used generates a need for reapplications but increases the safety of such procedures and enables patients' cancer treatment follow-up.


Assuntos
Toxinas Botulínicas Tipo A , Implantes Dentários , Preenchedores Dérmicos , Preenchedores Dérmicos/efeitos adversos , Durapatita , Estética Dentária , Humanos , Ácido Hialurônico , Neurotoxinas
6.
J Med Genet ; 59(3): 305-312, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-33685999

RESUMO

BACKGROUND: Pathogenic germline variants in Transient Receptor Potential Vanilloid 4 Cation Channel (TRPV4) lead to channelopathies, which are phenotypically diverse and heterogeneous disorders grossly divided in neuromuscular disorders and skeletal dysplasia. We recently reported in sporadic giant cell lesions of the jaws (GCLJs) novel, somatic, heterozygous, gain-of-function mutations in TRPV4, at Met713. METHODS: Here we report two unrelated women with a de novo germline p.Leu619Pro TRPV4 variant and an overlapping systemic disorder affecting all organs individually described in TRPV4 channelopathies. RESULTS: From an early age, both patients had several lesions of the nervous system including progressive polyneuropathy, and multiple aggressive giant cell-rich lesions of the jaws and craniofacial/skull bones, and other skeletal lesions. One patient had a relatively milder disease phenotype possibly due to postzygotic somatic mosaicism. Indeed, the TRPV4 p.Leu619Pro variant was present at a lower frequency (variant allele frequency (VAF)=21.6%) than expected for a heterozygous variant as seen in the other proband, and showed variable regional frequency in the GCLJ (VAF ranging from 42% to 10%). In silico structural analysis suggests that the gain-of-function p.Leu619Pro alters the ion channel activity leading to constitutive ion leakage. CONCLUSION: Our findings define a novel polysystemic syndrome due to germline TRPV4 p.Leu619Pro and further extend the spectrum of TRPV4 channelopathies. They further highlight the convergence of TRPV4 mutations on different organ systems leading to complex phenotypes which are further mitigated by possible post-zygotic mosaicism. Treatment of this disorder is challenging, and surgical intervention of the GCLJ worsens the lesions, suggesting the future use of MEK inhibitors and TRPV4 antagonists as therapeutic modalities for unmet clinical needs.


Assuntos
Canalopatias , Polineuropatias , Canais de Potencial de Receptor Transitório , Feminino , Células Gigantes , Humanos , Arcada Osseodentária , Mutação/genética , Crânio , Canais de Cátion TRPV/química , Canais de Cátion TRPV/genética , Canais de Potencial de Receptor Transitório/genética
7.
F1000Res ; 11: 505, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-38249120

RESUMO

Background: Prosthetic restorations are made to adapt or attach missing human parts in order to restore function and appearance. Maxillofacial defects connote a greater impact on patients, since the face cannot be concealed, and all the senses of the human body are expressed in it. Therefore, in order to restore the patient's quality of life, they are the ones that require the best possible adaptation to the characteristics of the patients. Methods: For the maxillofacial prostheses to fit patients, they must be personalized for each patient. The NGO "Mais Identidade" is a multidisciplinary team that specializes in the rehabilitation of patients with maxillofacial trauma. They use digital manufacturing as a tool to manufacture personalized maxillofacial prostheses for patients. With the help of the NGO, the following research is conducted with the purpose of evaluating different methods of additive manufacturing, 3D printing, in order to select the equipment that suits the needs of the method used in the manufacture of maxillofacial prostheses. To this end, eyelid models will be manufactured in different additive manufacturing equipment, and these will be evaluated according to their economic, physical, and aesthetic characteristics.


Assuntos
Implantação de Prótese , Qualidade de Vida , Humanos , Próteses e Implantes , Comércio , Pálpebras
8.
F1000Res ; 11: 582, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-38434006

RESUMO

Background: The artistic techniques necessary to fabricate facial prostheses mainly depend on individual skill and are not a resource easily reproduced. Digital technology has contributed to improved outcomes, often combining analog and new digital techniques in the same workflow. Methods: This article aims to present an innovative workflow to produce a final colored 3D printed and facial prosthesis by UV-map color translation into colored resin 3D printing. A modified +ID Methodology was used to obtain 3D models with the calibrated 3D printable patient's skin color. No hands-on physical molding, manual sculpture, or intrinsic silicone coloration was used. Results: The outcome resulted in acceptable aesthetics, adaptation, and an approximate color match after extrinsic coloration. The patient reported good comfort and acceptance. Conclusions: A direct resin 3D printed prosthesis may be a viable alternative, especially for rapid delivery as an immediate prosthesis or an option when there is no experienced anaplastogist to manufacture a conventional prosthesis.

9.
J Prosthet Dent ; 126(3): 452.e1-452.e6, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34301417

RESUMO

STATEMENT OF PROBLEM: Hygiene and disinfection are important factors for preserving facial prostheses and supporting tissue health. However, a method that does not accelerate degradation or color change is necessary. PURPOSE: The purpose of this in vitro study was to evaluate the effectiveness of irradiation with ultraviolet C light-emitting diode (UV-C LED) light in the disinfection and initial color stability of the silicone (A-588-1; Factor II) used in facial prostheses. MATERIAL AND METHODS: One hundred and twenty specimens were made, contaminated by multispecies biofilm, and divided into 5 groups (n=24) with different treatments: control, distilled water, 0.12% chlorhexidine, UV-C LED light, and dimethyl sulfoxide (DMSO) as the negative control. Cell viability was measured by the methyl tetrazolium salt method. Statistical analysis was performed by generalized linear models. Additional descriptive analysis was performed for color analysis by using 16 silicone specimens made with light and dark intrinsic coloring in 4 groups (controls and treatments n=4) submitted to UV-C LED light. The ΔE of the specimens was obtained by CIEDE200. RESULTS: The results of cell viability demonstrated a statistically significant difference among the groups (P<.001), with a microbial reduction after UVC-LED exposure compared with the control group. Regarding the color, the groups presented an average ΔE (light 0.205 and dark 0.308) compatible with visually imperceptible changes (light <0.7 and dark <1.2). CONCLUSIONS: Irradiation with UV-C LED light decreased the in vitro microbial cell viability of the medical silicone used in facial prostheses, demonstrating initial color stability.


Assuntos
Implantes Dentários , Prótese Maxilofacial , Cor , Desinfecção , Teste de Materiais , Elastômeros de Silicone , Raios Ultravioleta
10.
J Prosthodont ; 30(1): 91-94, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33270296

RESUMO

Conventional techniques described in the literature for the manufacture of ocular prostheses are time-consuming since they involve manual work. The use of technologies could improve this laborious process, providing better esthetic outcomes. This technique describes how to manufacture the ocular portion of an orbital prosthesis using a smartphone camera, color calibration with a tooth shade guide, and digital printing. This method allows clinicians to fabricate customized ocular prosthesis by using a photograph of the patient's eye, thus eliminating the need for hand-painting and manual work, and reducing fabrication time.


Assuntos
Estética Dentária , Smartphone , Calibragem , Cor , Humanos , Impressão Tridimensional , Desenho de Prótese
11.
Int J Oral Maxillofac Implants ; 35(1): 63-69, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31923290

RESUMO

PURPOSE: To compare the connection microgaps and the bacterial infiltration of implant-abutment interfaces of two extraoral implant models. MATERIALS AND METHODS: Two implant models were used: the inner connection and the flush connection types. The implant-abutment microgaps of five sets of each extraoral implant were evaluated with scanning electron microscopy. Eleven additional sets of each model design were immersed in Staphylococcus aureus cultures for 24 hours, and samples were obtained from the external surface and from the implant's internal chamber to quantify the colony-forming units. RESULTS: Scanning electron microscopy analysis showed that microgaps of the flush connection were smaller compared with the inner connection (P < .0001), and that bacterial counts were higher at the inner connection compared with the flush connection (P < .0001). CONCLUSION: Within the limitations of this experimental study, it can be concluded that the flush connection model presented a smaller microgap and fewer bacterial colonies compared with the inner connection model.


Assuntos
Projeto do Implante Dentário-Pivô , Implantes Dentários , Dente Suporte , Microscopia Eletrônica de Varredura
12.
Int J Dent ; 2018: 9368918, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29666649

RESUMO

The present study assessed the level of dentists' knowledge regarding oral cancer in the city of São Paulo, Brazil. A questionnaire was used to compare the level of knowledge among newly graduated and senior clinicians. A total of 20,154 e-mails were correctly delivered to the dentists registered in the database of the Regional Dentistry Council of São Paulo, and 477 (2.36%) responses were received. This sample consisted of 84 newly graduated clinicians and 105 senior clinicians. For the statistical analysis, the chi-square test and the logistic regression analysis were performed with α = 0.05, and the results were described herein. According to their knowledge level, the results were statistically different between the groups, since 19% of the newly graduated clinicians were evaluated with knowledge grade A (excellent) in comparison to 6.7% of the senior clinicians. In spite of the results indicated that newly graduated clinicians' knowledge regarding oral cancer was 2.1 times higher, 34.5% of the professionals in this group had regular or poor knowledge on the subject, and several questions relating to clinical characteristics and risk factors indicated that there still exist some knowledge gaps, demonstrating that there is a need for further studies and information activities addressing oral cancer.

13.
Clin Implant Dent Relat Res ; 20(4): 438-443, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29508545

RESUMO

STATEMENT OF PROBLEM: Evaluate the effect of orbital prosthesis retained by implants through a specific quality of life (QOL) questionnaire provides important information on patients QOL, great incentive for the multidisciplinary team and public health support to continue work in this area. PURPOSE: The objective of the study was to evaluate patient satisfaction with orbital implant-supported prostheses using an adapted quality of life questionnaire. MATERIALS AND METHODS: Forty five patients using orbital implant-supported prostheses for a period ranging from six to 120 months. The subjects answered a questionnaire that consisted of 10 questions covering appearance, retention, conspicuousness, self-confidence, difficulty of placement, difficulty of removal, cleaning, limitation of activities, discomfort of tissues, and recommendation of the method to other patients. Answers were expressed using a visual 100-mm scale. The arithmetic mean of the responses was converted into a percentage to represent the satisfaction index. RESULTS: Patients demonstrated a high level of satisfaction on all items, with the lowest rate being for aesthetics and the highest being for recommending the method to other patients. High satisfaction rates regarding the placement and removal of the prosthesis, discomfort to the tissues, and cleaning suggest the ease of handling of the prosthesis. High satisfaction with retention, self-confidence, conspicuousness of the prosthesis, and limitation of activities indicated an association with a better social life. CONCLUSIONS: The results showed that use of bone anchorage technique of extraoral prostheses provided a high level of satisfaction among patients, confirming that osseointegrated implants are a very important resource for the rehabilitation of orbital deformities.


Assuntos
Prótese Dentária Fixada por Implante/psicologia , Implantes Orbitários/psicologia , Satisfação do Paciente , Qualidade de Vida , Adulto , Idoso , Idoso de 80 Anos ou mais , Prótese Ancorada no Osso , Brasil , Implantes Dentários , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese , Estudos Retrospectivos , Estatísticas não Paramétricas , Inquéritos e Questionários , Adulto Jovem
14.
ImplantNewsPerio ; 3(1): 45-50, jan.-fev. 2018. ilus
Artigo em Português | LILACS | ID: biblio-881510

RESUMO

Objetivo: avaliar, por meio de extensometria, a infl uência da flange do implante de titânio na deformação superficial do osso. Material e métodos: um bloco de poliuretano simulando um osso tipo I mais corticalizado e menos medular (40 PCF) recebeu um implante de hexágono externo intraoral, sem flange 3,75 mm x 8,5 mm (G1) e um implante de hexágono externo extraoral, com flange 3,75 mm x 8 mm (G2). Em seguida, foram instalados componentes standard com 2 mm de altura de cinta metálica e cilindros metálicos para restauração provisória. Dois extensômetros lineares foram colados na superfície do bloco (mesial e distal de cada implante), e uma carga axial de 100 Ncm em uma máquina de ensaio universal foi aplicada, com cinco medições de microdeformação (µÎµ) para cada implante. Os dados foram submetidos ao teste Shapiro-Wilk para verifi car a homogenidade dos dados e em seguida ao teste t Student. Resultados: as médias e desvios-padrão obtidos foram: G1: 148,2 ± 5,84 e G2: 92,4 ± 11,24 µÆ, com diferença estatística significativa entre os grupos. Conclusão: os implantes extraorais tiveram melhor comportamento mecânico para as cargas axiais do que os implantes intraorais, sendo que a flange melhorou a distribuição da carga na superfície do bloco de poliuretano.


Objectives: to evaluate, by means of extensometry, the influence of the titanium implant flange on the superficial deformation of the bone. Material and methods: a polyurethane block simulating a more corticalized and less spinal type I bone (40 PCF) received an external intraoral hexagon implant with a 3.75 mm x 8.5 mm fl ange (G1) and an extraoral external hexagon implant, with flange 3.75 mm x 8 mm (G2). Subsequently, standard components with 2 mm high of metal strap and metal cylinders were installed for temporary restoration. Two linear strain gauges were glued to the surface of the block (mesial and distal of each implant), and an axial load of 100N in a universal test machine was applied with five microdemorphometric measurements (µÎµ) for each implant. The data were submitted to the Shapiro-Wilks test to verify the homogeneity of the data and then to the t-student test. Results: the means and standard deviations obtained were: G1: 148.2 ± 5.84 and G2: 92.4 ± 11.24 µÎµ, with signifi cant statistical difference between the groups. Conclusion: extraoral implants had better mechanical behavior for axial loads than intraoral implants, and the flange improved the load distribution on the surface of the polyurethane block.


Assuntos
Humanos , Estudo Comparativo , Prótese Maxilofacial , Implante de Prótese Maxilofacial , Osseointegração , Próteses e Implantes
15.
Int J Oral Maxillofac Implants ; 32(2): 385­391, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27643586

RESUMO

PURPOSE: The aim of this study was to evaluate the success and survival rates of extraoral implants for the fixation of facial prostheses in three anatomical regions. MATERIALS AND METHODS: Subjects were consecutive patients with facial defects who underwent implant placement by the same surgeon in the orbital, nasal, and auricular regions between 2003 and 2012. After a minimum of 4 months of osseointegration, prostheses were anchored to the implants, and the patients were monitored for 11 to 111 months. Success rate, implant survival time, and occurrence of previous radiotherapy were evaluated. Rate of implant survival was estimated as a function of the anatomical region of the three groups (orbital, nasal, or auricular), and confidence intervals were calculated using Kaplan-Meier analysis with α = .05. RESULTS: In the 68 patients' 138 fixed implants, 48 showed defects in the orbital, 9 in the nasal, and 11 in the auricular region. The success rates and survival times were 95.9% and 8.6 years for the orbital, 92.9% and 2.8 years for the nasal, and 92% and 9.0 years for the auricular region, respectively. The success rate of implants in previously irradiated regions was 90.3% for the orbital and 100% for the auricular region. None of the patients was irradiated in the nasal region. CONCLUSION: No significant differences in implant success or survival were observed with regard to anatomical region or previous irradiation.

16.
J Otolaryngol Head Neck Surg ; 45(1): 33, 2016 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-27225795

RESUMO

PURPOSE: The aim of this study is to present the development of a new technique to obtain 3D models using photogrammetry by a mobile device and free software, as a method for making digital facial impressions of patients with maxillofacial defects for the final purpose of 3D printing of facial prostheses. METHODS: With the use of a mobile device, free software and a photo capture protocol, 2D captures of the anatomy of a patient with a facial defect were transformed into a 3D model. The resultant digital models were evaluated for visual and technical integrity. The technical process and resultant models were described and analyzed for technical and clinical usability. RESULTS: Generating 3D models to make digital face impressions was possible by the use of photogrammetry with photos taken by a mobile device. The facial anatomy of the patient was reproduced by a *.3dp and a *.stl file with no major irregularities. 3D printing was possible. CONCLUSIONS: An alternative method for capturing facial anatomy is possible using a mobile device for the purpose of obtaining and designing 3D models for facial rehabilitation. Further studies must be realized to compare 3D modeling among different techniques and systems. CLINICAL IMPLICATION: Free software and low cost equipment could be a feasible solution to obtain 3D models for making digital face impressions for maxillofacial prostheses, improving access for clinical centers that do not have high cost technology considered as a prior acquisition.


Assuntos
Telefone Celular , Face/anatomia & histologia , Modelos Anatômicos , Fotogrametria/métodos , Impressão Tridimensional , Próteses e Implantes , Humanos , Aplicativos Móveis , Fotogrametria/instrumentação
17.
Int J Oral Maxillofac Implants ; 30(6): 1303-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26574856

RESUMO

PURPOSE: The purpose of this pilot study was to evaluate the behavior of stresses surrounding orbital model implants subjected to a load of a silicone oculo-palpebral prosthesis. MATERIALS AND METHODS: A photoelastic model was constructed mimicking the orbital cavity of an adult patient who underwent left orbital resection. Two 3.75 × 5-mm extraoral implants with 3.75 × 5.25-mm magnetic connectors were placed in the model to anchor a silicone oculo-palpebral prosthesis. The stress generated by prosthesis retention was evaluated using photoelasticity at 15, 30, and 60 minutes. The polariscope images were analyzed qualitatively at five areas surrounding the implants. These same areas were analyzed quantitatively using Matlab software based on the RGB color pattern. Data were compared with the Wilcoxon test. RESULTS: Using fringe localization, the qualitative analysis demonstrated that the area between the implants had the greatest stress. The quantitative analysis showed that the peri-implant stress increased significantly in proportion to the increase in prosthesis retention time. CONCLUSION: The oculo-palpebral prosthesis generated stress around the implants, and the stress intensity was directly proportional to the duration of use.


Assuntos
Implantes Orbitários , Retenção da Prótese/métodos , Estresse Mecânico , Adulto , Humanos , Modelos Biológicos , Projetos Piloto , Desenho de Prótese , Silicones
18.
Braz Dent J ; 26(3): 317-20, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26200161

RESUMO

Bisphosphonate-related osteonecrosis of the jaws (BROJ) has been described since 2003 as an adverse effect of bisphosphonate medications. These drugs act on the vasculature and bone remodeling, mainly on osteoclastic activity and can cause areas of necrotic bone exposure. Treatment for the BROJ is not yet defined, but surgical treatment is one of the forms proposed, which may cause oral deformities like sinus communication in some cases. In situations like this the buccal fat pad is an important alternative for coating nasal-oral communications, due its large blood supply, elasticity, absence of restriction by age and safety. This paper presents the case of a 58-year-old woman with BROJ in the left maxilla caused by the use of zoledronic acid for metastatic breast cancer. The extensive necrotic bone area was surgically removed resulting in oral sinus communication. A buccal fat pad was used to cover the defect. More studies should be performed regarding the treatment of BROJ but, if necessary, a buccal fat pad flap could be an alternative to solve nasal-oral communications related to BROJ.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/cirurgia , Conservadores da Densidade Óssea/efeitos adversos , Difosfonatos/efeitos adversos , Feminino , Humanos , Imidazóis/efeitos adversos , Pessoa de Meia-Idade , Retalhos Cirúrgicos , Ácido Zoledrônico
19.
Braz. dent. j ; 26(3): 317-320, May-Jun/2015. graf
Artigo em Inglês | LILACS | ID: lil-751864

RESUMO

Bisphosphonate-related osteonecrosis of the jaws (BROJ) has been described since 2003 as an adverse effect of bisphosphonate medications. These drugs act on the vasculature and bone remodeling, mainly on osteoclastic activity and can cause areas of necrotic bone exposure. Treatment for the BROJ is not yet defined, but surgical treatment is one of the forms proposed, which may cause oral deformities like sinus communication in some cases. In situations like this the buccal fat pad is an important alternative for coating nasal-oral communications, due its large blood supply, elasticity, absence of restriction by age and safety. This paper presents the case of a 58-year-old woman with BROJ in the left maxilla caused by the use of zoledronic acid for metastatic breast cancer. The extensive necrotic bone area was surgically removed resulting in oral sinus communication. A buccal fat pad was used to cover the defect. More studies should be performed regarding the treatment of BROJ but, if necessary, a buccal fat pad flap could be an alternative to solve nasal-oral communications related to BROJ.


Osteonecrose dos maxilares por bifosfonatos (OMB) tem sido descrita desde 2003 como um efeito adverso dos medicamentos bifosfonatos. Essas drogas atuam sobre a vascularização e remodelação óssea, principalmente na atividade osteoclástica, podendo gerar áreas de exposição óssea necrótica. O tratamento para a doença ainda não é definido, mas o tratamento cirúrgico é uma das formas preconizadas que, em algumas situações podem ocasionar deformações orais como as comunicações buco-sinusais. Em situações como esta o tecido adiposo bucal é uma alternativa importante para o recobrimento da comunicação oro-nasal, devido ao seu grande suprimento sanguíneo, elasticidade, ausência de restrição pela idade e segurança. Este trabalho apresenta um caso clínico de paciente de 58 anos do sexo feminino, portadora de OMB em maxila esquerda pelo uso de ácido zoledrônico para câncer metastático. A extensa remoção da porção óssea necrótica resultou em fístula buco-sinusal. O retalho do tecido adiposo bucal foi utilizado para cobrir o defeito. Mais estudos devem ser realizados com relação ao tratamento de OMB, no entanto, se necessário, o retalho de tecido adiposo bucal poderia ser uma alternativa para resolver a comunicação oro-nasal relacionada à OMB.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/cirurgia , Conservadores da Densidade Óssea/efeitos adversos , Difosfonatos/efeitos adversos , Imidazóis/efeitos adversos , Retalhos Cirúrgicos
20.
Clin Implant Dent Relat Res ; 17 Suppl 1: e245-50, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24393485

RESUMO

PURPOSE: The aim of the study was to compare the success rates of osseointegration among irradiated and nonirradiated cases submitted to implant placement for anchorage of orbit prostheses from 2003 to 2011. MATERIALS AND METHODS: Charts of 45 consecutive patients were analyzed, 31 men and 14 women, and they were divided in two groups, considering previous irradiation therapy. Nonirradiated group had 33 patients, and irradiated group had 12 patients. In total, 138 implants were installed, 42 (30.4%) in previously irradiated bone. RESULTS: The overall implant survival rate was 96.4% with a success rate of 99.0% among the nonirradiated patients and 90.5% among the irradiated patients (p = 0.03). CONCLUSIONS: Results showed that irradiated sites had a worse prognosis related to success of osseointegration, although the 90.5% survival rate in this group indicates that implant placement is a feasible alternative to anchor orbit prostheses considering the benefits that this technique offers to patients.


Assuntos
Irradiação Craniana , Implantes Orbitários , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Desenho de Prótese , Implantação de Prótese , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...