Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Microbiol Methods ; 165: 105694, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31491442

RESUMO

Methods validated by a standard setting organization enable public, industry and regulatory stakeholders to make decisions on the acceptability of products, devices and processes. This is because standard methods are demonstrably reproducible when performed in different laboratories by different researchers, responsive to different products, and rugged when small (usually inadvertent) variations from the standard procedure occur. The Single Tube Method (ASTM E2871) is a standard method that measures the efficacy of antimicrobials against biofilm bacteria that has been shown to be reproducible, responsive and rugged. In support of the reproducibility assessment, a six-laboratory study was performed using three antimicrobials: a sodium hypochlorite, a phenolic and a quaternary/alcohol blend, each tested at low and high efficacy levels. The mean log reduction in viable bacteria in this study ranged from 2.32 to 4.58 and the associated reproducibility standard deviations ranged from 0.89 to 1.67. Independent follow-up testing showed that the method was rugged with respect to deviations in sonication duration and sonication power but slightly sensitive to sonicator reservoir degassing and tube location within the sonicator bath. It was also demonstrated that when a coupon was dropped into a test tube, bacteria can splash out of reach of the applied antimicrobials, resulting in substantial bias when estimating log reductions for the products tested. Bias can also result when testing products that hinder the harvesting of microbes from test surfaces. The culmination of this work provided recommended changes to the early version of the standard method E2871-13 (ASTM, 2013b) including use of splashguards and microscopy checks. These changes have been incorporated into a revised ASTM method E2871-19 (ASTM 2019) that is the basis for the first regulatory method (ATMP-MB-20) to substantiate "kills biofilm" claims for antimicrobials registered and sold in the US.


Assuntos
Antibacterianos/toxicidade , Biofilmes , Desinfetantes/toxicidade , Pseudomonas aeruginosa , Álcoois/toxicidade , Viés , Biofilmes/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Hidroxibenzoatos/toxicidade , Pseudomonas aeruginosa/efeitos dos fármacos , Pseudomonas aeruginosa/crescimento & desenvolvimento , Compostos de Amônio Quaternário/toxicidade , Padrões de Referência , Hipoclorito de Sódio/toxicidade , Propriedades de Superfície
2.
Biofouling ; 34(7): 826-834, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30311502

RESUMO

The inactivation of Pseudomonas aeruginosa biofilms grown on glass under high shear stress and exposed to a range of dissolved ozone concentrations (2, 5 and 7 ppm) at 10 and 20 min was investigated. The regression equation, log reduction (biofilm) = 0.64 + 0.59×(C - 2) + 0.33×(T - 10), described the dependence of biofilm inactivation on the dissolved ozone concentration (C, ppm) and contact time (T, min). The predicted D-values were 11.1, 5.7 and 2.2 min at 2, 5 and 7 ppm, respectively. Inactivation of biofilms grown on various surfaces was tested at a single dissolved ozone concentration of 5 ppm and a single exposure time of 20 min. Biofilms grown on plastic materials showed inactivation results similar to that of biofilms on glass, while biofilms grown on ceramics were statistically significantly more difficult to inactivate, suggesting the importance of utilizing non-porous materials in industrial and clinical settings.


Assuntos
Biofilmes/efeitos dos fármacos , Ozônio/farmacologia , Pseudomonas aeruginosa/efeitos dos fármacos , Interações Hidrofóbicas e Hidrofílicas , Testes de Sensibilidade Microbiana , Estresse Mecânico , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...