Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 80(7): 1060-8, 2012 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22644906

RESUMO

BACKGROUND: Embolic protection devices (EPDs) are used to provide protection against brain embolization during carotid artery stenting (CAS) to treat carotid artery stenosis, but the optimal type of EPD has not been determined. Distally positioned filters are commonly used but do not provide protection during crossing of the lesion. This prospective, multicenter study investigated a proximally placed device (GORE Flow Reversal System) that reverses blood flow in the internal carotid artery during CAS, thereby directing emboli away from the brain. METHODS: Outcomes in 122 patients (28% symptomatic), who underwent CAS using the flow reversal system were assessed (intention-to-treat analysis). The primary endpoint was a major adverse event (MAE; defined as death or stroke) within 30 days of CAS. The secondary endpoint was a myocardial infarction (MI) or nonstroke-related neurologic event within 30 days. RESULTS: The flow reversal system could not be used in one patient because of severe vessel tortuosity and in two patients (1.6%) because of intolerance. The 30-day MAE rate and the secondary endpoint rate were each 1.6%. No patient in the series died or had an MI within 30 days. No patient who was symptomatic before CAS had an MAE. One symptomatic and one asymptomatic patient had a transient ischemic attack. CONCLUSIONS: Use of the GORE Flow Reversal System during CAS had a high rate of technical success and low 30-day rates of adverse neurologic and cardiac events.


Assuntos
Angioplastia com Balão/instrumentação , Artéria Carótida Interna/fisiopatologia , Estenose das Carótidas/terapia , Circulação Cerebrovascular , Transtornos Cerebrovasculares/prevenção & controle , Dispositivos de Proteção Embólica , Stents , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/mortalidade , Estenose das Carótidas/mortalidade , Estenose das Carótidas/fisiopatologia , Transtornos Cerebrovasculares/etiologia , Transtornos Cerebrovasculares/mortalidade , Transtornos Cerebrovasculares/fisiopatologia , Europa (Continente) , Feminino , Hospitais com Alto Volume de Atendimentos , Humanos , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/fisiopatologia , Ataque Isquêmico Transitório/prevenção & controle , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Desenho de Prótese , Fluxo Sanguíneo Regional , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/fisiopatologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...