Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Pediatrics ; 141(5)2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29691284

RESUMO

: media-1vid110.1542/5727212367001PEDS-VA_2017-4065Video Abstract OBJECTIVES: Determine the performance of the American Academy of Pediatrics (AAP) critical congenital heart disease (CCHD) newborn screening algorithm and the impact of an alternative algorithm. METHODS: Screening was performed on term infants without a known CCHD diagnosis at or near 24 hours of age at a tertiary birth hospital by using the AAP algorithm from 2013 to 2016. Retrospective review from the birth hospital and the area's sole pediatric cardiac center identified true- and false-positives and true- and false-negatives. A simulation study modeled the results of a modified screening algorithm with a single repeat pulse oximetry test instead of 2. RESULTS: Screening results were collected on 77 148 newborns . By using the current AAP algorithm, 77 114 (99.96%) infants passed screening, 18 infants failed for an initial saturation of <90%, and 16 failed after not attaining a passing pulse oximetry level after 3 tests. There was 1 true-positive (total anomalous pulmonary venous return), 33 false-positives, and 6 false-negatives, yielding an overall specificity of 99.96%, a sensitivity of 14.3%, and a false-positive rate of 0.043%. Among false-positives, 10 (31.3%) had significant non-CCHD disease. Simulating the modified algorithm, sensitivity remained at 14.3%, and the false-positive rate increased to 0.054%. CONCLUSIONS: Although CCHD screening in a tertiary care birth hospital may not detect many new cases of CCHD, it can detect other important diseases in newborns. Modifying the screening algorithm to 1 repeat pulse oximetry test instead of 2 may detect additional infants with significant disease without a substantial increase in the false-positive rate.


Assuntos
Algoritmos , Cardiopatias Congênitas/diagnóstico , Triagem Neonatal/métodos , Oximetria/métodos , Humanos , Hipóxia/diagnóstico , Hipóxia/etiologia , Recém-Nascido , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
Echocardiography ; 26(1): 93-5, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19125812

RESUMO

A 55-year-old man developed hypertension and acute epigastric pain during dobutamine-atropine stress echocardiography (DASE). Evaluation-including a helical computed tomography (CT) scan of the abdomen and pelvis, as well as surgical exploration-revealed a ruptured splenic artery aneurysm. The patient died, despite multiple surgical interventions and a massive blood product transfusion. Impressively, no deaths from DASE have been previously reported. Additionally, no adverse sequelae during DASE have been reported in patients with an unruptured abdominal aortic aneurysm >or=4 cm in diameter or with an unruptured intracranial aneurysm. We report the first case, to our knowledge, of death caused by splenic artery aneurysm rupture during DASE. Splenic artery aneurysm rupture during DASE, though rare, can lead to death.


Assuntos
Aneurisma Roto/diagnóstico por imagem , Atropina , Ecocardiografia sob Estresse/efeitos adversos , Artéria Esplênica/diagnóstico por imagem , Aneurisma Roto/cirurgia , Evolução Fatal , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Artéria Esplênica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA