Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ann Biomed Eng ; 2024 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-39098978

RESUMO

PURPOSE: This study aims to explore how cyclic loading influences creep response in the lumbar spine under combined flexion-compression loading. METHODS: Ten porcine functional spinal units (FSUs) were mechanically tested in cyclic or static combined flexion-compression loading. Creep response between loading regimes was compared using strain-time histories and linear regression. High-resolution computed tomography (µCT) visualized damage to FSUs. Statistical methods, ANCOVA and ANOVA, assessed differences in behavior between loading regimes. RESULTS: Cyclic and static loading regimes exhibited distinct creep response patterns and biphasic response. ANCOVA and ANOVA analyses revealed significant differences in slopes of creep behavior in both linear phases. Cyclic tests consistently showed endplate fractures in µCT imaging. CONCLUSION: The study reveals statistically significant differences in creep response between cyclic and static loading regimes in porcine lumbar spinal units under combined flexion-compression loading. The observed biphasic behavior suggests distinct phases of tissue response, indicating potential shifts in load transfer mechanisms. Endplate fractures in cyclic tests suggest increased injury risk compared to static loading. These findings underscore the importance of considering loading conditions in computational models and designing preventive measures for occupations involving repetitive spinal loading.

2.
Ann Biomed Eng ; 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39028399

RESUMO

PURPOSE: Measuring head kinematics data is important to understand and develop methods and standards to mitigate head injuries in contact sports. Instrumented mouthguards (iMGs) have been developed to address coupling issues with previous sensors. Although validated with anthropomorphic test devices (ATDs), there is limited post-mortem human subjects (PMHS) data which provides more accurate soft tissue responses. This study evaluated two iMGs (Prevent Biometrics (PRE) and Diversified Technical Systems (DTS) in response to direct jaw impacts. METHODS: Three unembalmed male cadaver heads were properly fitted with two different boil-and-bite iMGs and impacted with hook (4 m/s) and uppercut (3 m/s) punches. A reference sensor (REF) was rigidly attached to the base of the skull, impact kinematics were transformed to the head center of gravity and linear and angular kinematic data were compared to the iMGs including Peak Linear Acceleration, Peak Angular Acceleration, Peak Angular Velocity, Head Injury Criterion (HIC), HIC duration, and Brain Injury Criterion. RESULTS: Compared to the REF sensor, the PRE iMG underpredicted most of the kinematic data with slopes of the validation regression line between 0.72 and 1.04 and the DTS overpredicted all the kinematic data with slopes of the regression line between 1.4 and 8.7. CONCLUSION: While the PRE iMG was closer to the REF sensor compared to the DTS iMG, the results did not support the previous findings reported with use of ATDs. Hence, our study highlights the benefits of using PMHS for validating the accuracy of iMGs since they closely mimic the human body compared to any ATD's mandible.

4.
Ann Biomed Eng ; 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38951421

RESUMO

Low back pain (LBP) is a common medical condition worldwide, though the etiology of injuries causing most LBP is unknown. Flexion and repeated compression increase lumbar injury risk, yet the complex viscoelastic behavior of the lumbar spine has not been characterized under this loading scheme. Characterizing the non-injurious primary creep behavior in the lumbar spine is necessary for understanding the biomechanical response preceding injury. Fifteen porcine lumbar spinal units were loaded in repeated flexion-compression with peak compressive stresses ranging from 1.41 to 4.68 MPa. Applied loading simulated real loading exposures experienced by high-speed watercraft occupants. The strain response in the primary creep region was modeled for all tests using a generalized Kelvin-Voigt model. A quasilinear viscoelastic (QLV) approach was used to separate time-dependent (creep) and stress-dependent (elastic) responses. Optimizations between the models and experimental data determined creep time constants, creep coefficients, and elastic constants associated with this tissue under repeated flexion-compression loading. Average R2 for all fifteen models was 0.997. Creep time constants optimized across all fifteen models were 24 s and 580 s and contributed to 20 ± 3% and 30 ± 3% of the overall strain response, respectively. The non-transient behavior contributed to 50 ± 0% of the overall response. Elastic behavior for this porcine population had an average standard deviation of 24.5% strain across the applied stress range. The presented primary creep characterization provides the response precursor to injurious behavior in the lumbar spine. Results from this study can further inform lumbar injury prediction and kinematic models.

5.
Ann Biomed Eng ; 2024 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-38910203

RESUMO

Instrumented mouthguard systems (iMGs) are commonly used to study rigid body head kinematics across a variety of athletic environments. Previous work has found good fidelity for iMGs rigidly fixed to anthropomorphic test device (ATD) headforms when compared to reference systems, but few validation studies have focused on iMG performance in human cadaver heads. Here, we examine the performance of two boil-and-bite style iMGs in helmeted cadaver heads. Three unembalmed human cadaver heads were fitted with two instrumented boil-and-bite mouthguards [Prevent Biometrics and Diversified Technical Systems (DTS)] per manufacturer instructions. Reference sensors were rigidly fixed to each specimen. Specimens were fitted with a Riddell SpeedFlex American football helmet and impacted with a rigid impactor at three velocities and locations. All impact kinematics were compared at the head center of gravity. The Prevent iMG performed comparably to the reference system up to ~ 60 g in linear acceleration, but overall had poor correlation (CCC = 0.39). Prevent iMG angular velocity and BrIC generally well correlated with the reference, while underestimating HIC and overestimating HIC duration. The DTS iMG consistently overestimated the reference across all measures, with linear acceleration error ranging from 10 to 66%, and angular acceleration errors greater than 300%. Neither iMG demonstrated consistent agreement with the reference system. While iMG validation efforts have utilized ATD testing, this study highlights the need for cadaver testing and validation of devices intended for use in-vivo, particularly when considering realistic (non-idealized) sensor-skull coupling, when accounting for interactions with the mandible and when subject-specific anatomy may affect device performance.

6.
Ann Biomed Eng ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748343

RESUMO

Low back pain (LBP) affects 50-80% of adults at some point in their lifetime, yet the etiology of injury is not well understood. Those exposed to repeated flexion-compression are at a higher risk for LBP, such as helicopter pilots and motor vehicle operators. Animal injury models offer insight into in vivo injury mechanisms, but interspecies scaling is needed to relate animal results to human. Human (n = 16) and porcine (n = 20) lumbar functional spinal units (FSUs) were loaded in repeated flexion-compression (1 Hz) to determine endplate fracture risk over long loading exposures. Flexion oscillated from 0 to 6° and peak applied compressive stress ranged from 0.65 to 2.38 MPa for human and 0.64 to 4.68 MPa for porcine specimens. Five human and twelve porcine injuries were observed. The confidence intervals for human and porcine 50% injury risk curves in terms of stress and cycles overlapped, indicating similar failure behavior for this loading configuration. However, porcine specimens were more tolerant to the applied loading compared to human, demonstrated by a longer time-to-failure for the same applied stress. Optimization revealed that time-to-failure in human specimens was approximately 25% that of porcine specimens at a given applied stress within 0.65-2.38 MPa. This study determined human and porcine lumbar endplate fracture risks in long-duration repeated flexion-compression that can be directly used for future equipment and vehicle design, injury prediction models, and safety standards. The interspecies scale factor produced in this study can be used for previous and future porcine lumbar injury studies to scale results to relevant human injury.

7.
Proc Inst Mech Eng H ; 238(5): 562-574, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38563211

RESUMO

Due to its ability to induce heterogenous, patient-specific damage in pulmonary alveoli and capillaries, COVID-19 poses challenges in defining a uniform profile to elucidate infection across all patients. Computational models that integrate changes in ventilation and perfusion with heterogeneous damage profiles offer valuable insights into the impact of COVID-19 on pulmonary health. This study aims to develop an in silico hypothesis-testing platform specifically focused on studying microvascular pulmonary perfusion in COVID-19-infected lungs. Through this platform, we explore the effects of various acinar-level pulmonary perfusion abnormalities on global lung function. Our modelling approach simulates changes in pulmonary perfusion and the resulting mismatch of ventilation and perfusion in COVID-19-afflicted lungs. Using this coupled modelling platform, we conducted multiple simulations to assess different scenarios of perfusion abnormalities in COVID-19-infected lungs. The simulation results showed an overall decrease in ventilation-perfusion (V/Q) ratio with inclusion of various types of perfusion abnormalities such as hypoperfusion with and without microangiopathy. This model serves as a foundation for comprehending and comparing the spectrum of findings associated with COVID-19 in the lung, paving the way for patient-specific modelling of microscale lung damage in emerging pulmonary pathologies like COVID-19.


Assuntos
COVID-19 , Simulação por Computador , Pulmão , COVID-19/fisiopatologia , Humanos , Pulmão/irrigação sanguínea , Pulmão/fisiopatologia , Modelos Biológicos , Circulação Pulmonar , Microvasos/fisiopatologia
8.
Comput Biol Med ; 145: 105513, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35447459

RESUMO

Physics-based multi-scale in silico models offer an excellent opportunity to study the effects of heterogeneous tissue damage on airflow and pressure distributions in COVID-19-afflicted lungs. The main objective of this study is to develop a computational modeling workflow, coupling airflow and tissue mechanics as the first step towards a virtual hypothesis-testing platform for studying injury mechanics of COVID-19-afflicted lungs. We developed a CT-based modeling approach to simulate the regional changes in lung dynamics associated with heterogeneous subject-specific COVID-19-induced damage patterns in the parenchyma. Furthermore, we investigated the effect of various levels of inflammation in a meso-scale acinar mechanics model on global lung dynamics. Our simulation results showed that as the severity of damage in the patient's right lower, left lower, and to some extent in the right upper lobe increased, ventilation was redistributed to the least injured right middle and left upper lobes. Furthermore, our multi-scale model reasonably simulated a decrease in overall tidal volume as the level of tissue injury and surfactant loss in the meso-scale acinar mechanics model was increased. This study presents a major step towards multi-scale computational modeling workflows capable of simulating the effect of subject-specific heterogenous COVID-19-induced lung damage on ventilation dynamics.


Assuntos
COVID-19 , Simulação por Computador , Computadores , Humanos , Pulmão/diagnóstico por imagem , Ventilação Pulmonar , Mecânica Respiratória , Fluxo de Trabalho
9.
Life Sci ; 274: 119341, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33716059

RESUMO

The COVID-19 pandemic surges on as vast research is produced to study the novel SARS-CoV-2 virus and the disease state it induces. Still, little is known about the impact of COVID-19-induced microscale damage in the lung on global lung dynamics. This review summarizes the key histological features of SARS-CoV-2 infected alveoli and links the findings to structural tissue changes and surfactant dysfunction affecting tissue mechanical behavior similar to changes seen in other lung injury. Along with typical findings of diffuse alveolar damage affecting the interstitium of the alveolar walls and blood-gas barrier in the alveolar airspace, COVID-19 can cause extensive microangiopathy in alveolar capillaries that further contribute to mechanical changes in the tissues and may differentiate it from previously studied infectious lung injury. Understanding microlevel damage impact on tissue mechanics allows for better understanding of macroscale respiratory dynamics. Knowledge gained from studies into the relationship between microscale and macroscale lung mechanics can allow for optimized treatments to improve patient outcomes in case of COVID-19 and future respiratory-spread pandemics.


Assuntos
COVID-19/complicações , Lesão Pulmonar/patologia , Lesão Pulmonar/virologia , Ventilação Pulmonar , SARS-CoV-2/isolamento & purificação , COVID-19/transmissão , COVID-19/virologia , Humanos
10.
J Mech Behav Biomed Mater ; 70: 84-94, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27492734

RESUMO

Interpenetrating network (IPN) hydrogel materials are recognized for their unique mechanical properties. While IPN elasticity and toughness properties have been explored in previous studies, the factors that impact the time-dependent stress relaxation behavior of IPN materials are not well understood. Time-dependent (i.e. viscoelastic) mechanical behavior is a critical design parameter in the development of materials for a variety of applications, such as medical simulation devices, flexible substrate materials, cellular mechanobiology substrates, or regenerative medicine applications. This study reports a novel technique for 3D printing alginate-polyacrylamide IPN gels with tunable elastic and viscoelastic properties. The viscoelastic stress relaxation behavior of the 3D printed alginate-polyacrylamide IPN hydrogels was influenced most strongly by varying the concentration of the acrylamide cross-linker (MBAA), while the elastic modulus was affected most by varying the concentration of total monomer material. The material properties of our 3D printed IPN constructs were consistent with those reported in the biomechanics literature for soft tissues such as skeletal muscle, cardiac muscle, skin and subcutaneous tissue.


Assuntos
Materiais Biocompatíveis/química , Hidrogéis/química , Impressão Tridimensional , Módulo de Elasticidade , Humanos , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA