Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Acta Neurochir (Wien) ; 163(4): 971-979, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33325003

RESUMO

BACKGROUND: To measure extracranial doses from Gamma Knife Perfexion (GKP) intracranial stereotactic radiosurgery (SRS) and model the risk of malignancy after SRS for different treatment platforms. METHODS: Doses were measured for 20 patients undergoing SRS on a GKP at distances of 18, 43 and 75 cm from the target, corresponding to the approximate positions of the thyroid, breast and gonads respectively. A literature review was conducted to collect comparative data from other radiosurgery platforms. All data was used to calculate the dose to body organs. The National Cancer Institute (NCI) RadRAT calculator was used to estimate excess lifetime cancer risk from this exposure. Five different age groups covering childhood and younger adults were modelled for both sexes. RESULTS: Extracranial doses delivered during SRS with the GKP were a median 0.04%, 0.008% and 0.002% of prescription dose at 18 cm, 43 cm and 70 cm from the isocentre respectively. Comparison with the literature revealed that the extracranial dose was lowest from GKP, then linacs equipped with micro-multileaf collimators (mMLC), then linacs equipped with circular collimators (cones), and highest from Cyberknife (CK). Estimated lifetime risks of radiation-induced malignancy in the body for patients treated with SRS aged 5-45 years were 0.03-0.88%, 0.36-11%, 0.61-18% and 2.2-39% for GKP, mMLC, cones and CK respectively. CONCLUSIONS: We have compared typical extracranial doses from different platforms and quantified the lifetime risk of radiation-induced malignancy. The risk varies with platform. This should be taken into account when treating children and young adults with SRS. The concept of a therapeutic reference level (TRL), similar to the diagnostic reference level (DRL) established in radiology, is proposed.


Assuntos
Neoplasias Induzidas por Radiação/prevenção & controle , Radiocirurgia/normas , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Induzidas por Radiação/epidemiologia , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Padrões de Referência
2.
Adv Exp Med Biol ; 1337: 127-135, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34972899

RESUMO

Social distancing and the recent lock down due to COVID-19 has increased the feeling of disconnection, isolation, and suffering in vulnerable individuals and has brought forward questions regarding open acute care psychiatric units that cannot be answered by the literature. In Greece, there is no available research on how open ward environments are perceived and experienced by mental health professionals. The aim of the present study was to illuminate nurses' experiences of working in a public psychiatric hospital which traditionally operates with open doors. Eleven nursing care providers were interviewed, and thematic analysis was employed to explore their experiences of working in locked psychiatric acute care units. Participants described nursing care in units with an open door policy as "acceptance," "availability of staff," "real respect for the person," "ensuring patients' rights," "listening to the person," and "negotiation and not imposition." Trust in therapeutic relationships was perceived as greatly dependent on the trust being given to patients indirectly by the open door policy. Being trusted enhanced patients' self-determination and self-confidence leading to their empowerment. Containment of an acute mental health crisis took place through medication and meaningful discussions with patients and significant others rather than locking the door of the unit. Overall, meaningful care led to professional emancipation, but compassion fatigue narratives emphasized the need for continuous education, support and clinical supervision as necessary support for mental health nurses in a system of mental health provision often reduced to the point of crisis.


Assuntos
COVID-19 , Enfermeiras e Enfermeiros , Controle de Doenças Transmissíveis , Humanos , Políticas , SARS-CoV-2
3.
Mol Psychiatry ; 25(12): 3399-3412, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-30279455

RESUMO

Next-generation genetic sequencing (NGS) technologies facilitate the screening of multiple genes linked to neurodegenerative dementia, but there are few reports about their use in clinical practice. Which patients would most profit from testing, and information on the likelihood of discovery of a causal variant in a clinical syndrome, are conspicuously absent from the literature, mostly for a lack of large-scale studies. We applied a validated NGS dementia panel to 3241 patients with dementia and healthy aged controls; 13,152 variants were classified by likelihood of pathogenicity. We identified 354 deleterious variants (DV, 12.6% of patients); 39 were novel DVs. Age at clinical onset, clinical syndrome and family history each strongly predict the likelihood of finding a DV, but healthcare setting and gender did not. DVs were frequently found in genes not usually associated with the clinical syndrome. Patients recruited from primary referral centres were compared with those seen at higher-level research centres and a national clinical neurogenetic laboratory; rates of discovery were comparable, making selection bias unlikely and the results generalisable to clinical practice. We estimated penetrance of DVs using large-scale online genomic population databases and found 71 with evidence of reduced penetrance. Two DVs in the same patient were found more frequently than expected. These data should provide a basis for more informed counselling and clinical decision making.


Assuntos
Demência , Sequenciamento de Nucleotídeos em Larga Escala , Idoso , Demência/genética , Genômica , Humanos , Mutação/genética , Encaminhamento e Consulta
4.
Phys Med Biol ; 65(4): 045011, 2020 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-31860889

RESUMO

The dosimetric accuracy of the Leksell GammaPlan Convolution calculation algorithm was evaluated through comparison with corresponding Monte Carlo (MC) dosimetric results. MC simulations were based on generated sector phase space files for the 4 mm, 8 mm and 16 mm collimator sizes, using a previous comprehensive Gamma Knife Perfexion™ source model and validated using film dosimetry. Test cases were designed for the evaluation of the Convolution algorithm involving irradiation of homogeneous and inhomogeneous phantom geometries mimicking clinical cases, with radiation fields created using one sector (single sector), all sectors with the same (single shot) or different (composite shot) collimator sizes. Dose calculations using the Convolution algorithm were found to be in excellent agreement (gamma pass rate greater than 98%, applying 1%/1 mm local dose difference and distance agreement criteria), with corresponding MC calculations, indicating the accuracy of the Convolution algorithm in homogeneous and heterogeneous model geometries. While of minor clinical importance, large deviations were observed for the voxels laying inside air media. The calculated beam on times using the Convolution algorithm were found to increase (up to 7%) relative to the TMR 10 algorithm currently used in clinical practice, especially in a test case mimicking a brain metastasis close to the skull, in excellent agreement with corresponding MC calculations.


Assuntos
Algoritmos , Doses de Radiação , Radiocirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/secundário , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
5.
Radiat Prot Dosimetry ; 172(4): 409-415, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26656074

RESUMO

The aim of the present study is the estimation of radiation burden during liver chemoembolisation procedures. Organ dose and effective dose conversion factors, normalised to dose-area product (DAP), were estimated for chemoembolisation procedures using a Monte Carlo transport code in conjunction with an adult mathematical phantom. Exposure data from 32 patients were used to determine the exposure projections for the simulations. Equivalent organ (HT) and effective (E) doses were estimated using individual DAP values. The organs receiving the highest amount of doses during these exams were lumbar spine, liver and kidneys. The mean effective dose conversion factor was 1.4 Sv Gy-1 m-2 Dose conversion factors can be useful for patient-specific radiation burden during chemoembolisation procedures.


Assuntos
Quimioembolização Terapêutica , Neoplasias Hepáticas/terapia , Método de Monte Carlo , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto , Humanos , Prognóstico , Dosagem Radioterapêutica
6.
Phys Med ; 31(7): 785-91, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25900891

RESUMO

PURPOSE: To estimate the mean glandular dose of contrast enhanced digital mammography, using the EGSnrc Monte Carlo code and female adult voxel phantom. METHODS: Automatic exposure control of full field digital mammography system was used for the selection of the X-ray spectrum and the exposure settings for dual energy imaging. Measurements of the air-kerma and of the half value layers were performed and a Monte Carlo simulation of the digital mammography system was used to compute the mean glandular dose, for breast phantoms of various thicknesses, glandularities and for different X-ray spectra (low and high energy). RESULTS: For breast phantoms of 2.0-8.0 cm thick and 0.1-100% glandular fraction, CC view acquisition, from AEC settings, can result in a mean glandular dose of 0.450 ± 0.022 mGy -2.575 ± 0.033 mGy for low energy images and 0.061 ± 0.021 mGy - 0.232 ± 0.033 mGy for high energy images. In MLO view acquisition mean glandular dose values ranged between 0.488 ± 0.007 mGy - 2.080 ± 0.021 mGy for low energy images and 0.065 ± 0.012 mGy - 0.215 ± 0.010 mGy for high energy images. CONCLUSION: The low kV part of contrast enhanced digital mammography is the main contributor to total mean glandular breast dose. The results of this study can be used to provide an estimated mean glandular dose for individual cases.


Assuntos
Meios de Contraste , Mamografia/instrumentação , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação , Adulto , Feminino , Humanos , Radiometria
7.
Radiat Prot Dosimetry ; 165(1-4): 369-72, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25836682

RESUMO

Mammography is a standard procedure that facilitates breast cancer detection. Initial results of contrast-enhanced digital mammography (CEDM) are promising. The purpose of this study is to assess the CEDM radiation dose using a Monte Carlo code. EGSnrc MC code was used to simulate the interaction of photons with matter and estimate the glandular dose (Dg). A voxel female human phantom with a 2-8-cm breast thickness range and a breast glandular composition of 50 % was applied. Dg values ranged between 0.96 and 1.45 mGy (low and high energy). Dg values for a breast thickness of 5.0 cm and a glandular fraction of 50 % for craniocaudal and mediolateral oblique view were 1.12 (low energy image contribution is 0.98 mGy) and 1.07 (low energy image contribution is 0.95 mGy), respectively. The low kV part of CEDM is the main contributor to total glandular breast dose.


Assuntos
Absorciometria de Fóton/métodos , Meios de Contraste , Mamografia/métodos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Adulto , Ar , Mama/patologia , Simulação por Computador , Feminino , Humanos , Método de Monte Carlo , Neovascularização Patológica , Doses de Radiação , Radiometria
8.
Radiat Prot Dosimetry ; 163(2): 202-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24876338

RESUMO

Radiation protection and estimation of the radiological risk in paediatric radiology is essential due to children's significant radiosensitivity and their greater overall health risk. The purpose of this study was to estimate the organ and effective doses of paediatric patients undergoing barium meal (BM) examinations and also to evaluate the assessment of radiation Risk of Exposure Induced cancer Death (REID) to paediatric patients undergoing BM examinations. During the BM studies, fluoroscopy and multiple radiographs are involved. Since direct measurements of the dose in each organ are very difficult if possible at all, clinical measurements of dose-area products (DAPs) and the PCXMC 2.0 Monte Carlo code were involved. In clinical measurements, DAPs were assessed during examination of 51 patients undergoing BM examinations, separated almost equally in three age categories, neonatal, 1- and 5-y old. Organs receiving the highest amounts of radiation during BM examinations were as follows: the stomach (10.4, 10.2 and 11.1 mGy), the gall bladder (7.1, 5.8 and 5.2 mGy) and the spleen (7.5, 8.2 and 4.3 mGy). The three values in the brackets correspond to neonatal, 1- and 5-y-old patients, respectively. For all ages, the main contributors to the total organ and effective doses are the fluoroscopy projections. The average DAP values and absorbed doses to patient were higher for the left lateral projections. The REID was calculated for boys (4.8 × 10(-2), 3.0 × 10(-2) and 2.0 × 10(-2) %) for neonatal, 1- and 5-y old patients, respectively. The corresponding values for girl patients were calculated (12.1 × 10(-2), 5.5 × 10(-2) and 3.4 × 10(-2) %).


Assuntos
Envelhecimento/fisiologia , Fluoroscopia , Modelos Estatísticos , Doses de Radiação , Vísceras/fisiologia , Contagem Corporal Total/métodos , Absorção de Radiação , Administração Oral , Bário/administração & dosagem , Pré-Escolar , Simulação por Computador , Meios de Contraste/administração & dosagem , Humanos , Lactente , Recém-Nascido , Masculino , Método de Monte Carlo , Especificidade de Órgãos/fisiologia , Software
9.
Phys Med ; 30(4): 432-6, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24374260

RESUMO

OBJECTIVES: To estimate the organ equivalent doses and the effective doses (E) in patient undergoing percutaneous transhepatic biliary drainage (PTBD) examinations, using the MCNP5 and PCXMC2 Monte Carlo-based codes. METHODS: The purpose of this study is to estimate the organ doses to patients undergoing PTBD examinations by clinical measurements and Monte Carlo simulation. Dose area products (DAP) values were assessed during examination of 43 patients undergoing PTBD examination separated into groups based on the gender and the dimensions and location of the beam. RESULTS: Monte Carlo simulation of photon transport in male and female mathematical phantoms was applied using the MCNP5 and PCXMC2 codes in order to estimate equivalent organ doses. Regarding the PTBD examination the organ receiving the maximum radiation dose was the lumbar spine. The mean calculated HT for the lumbar spine using the MCNP5 and PCXMC2 methods respectively, was 117.25 mSv and 131.7 mSv, in males. The corresponding doses were 139.45 mSv and 157.1 mSv respectively in females. The HT values for organs receiving considerable amounts of radiation during PTBD examinations were varied between 0.16% and 73.2% for the male group and between 1.10% and 77.6% for the female group. E in females and males using MCNP5 and PCXMC2.0 was 5.88 mSv and 6.77 mSv, and 4.93 mSv and 5.60 mSv. CONCLUSION: The doses remain high compared to other invasive operations in interventional radiology. There is a reasonable good coincidence between the MCNP5 and PCXMC2.0 calculation for most of the organs.


Assuntos
Angiografia/métodos , Ductos Biliares/cirurgia , Colangiografia/métodos , Drenagem/métodos , Método de Monte Carlo , Doses de Radiação , Angiografia/efeitos adversos , Colangiografia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco
10.
Radiat Prot Dosimetry ; 157(3): 355-62, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23765072

RESUMO

The estimation of the radiological risk in the case of children is of particular importance due to their enhanced radiosensitivity when compared with that of adult patients. The purpose of this study is to estimate the organ and effective doses of paediatric patients undergoing micturating cystourethrography examinations. Since direct measurements of the dose in each organ are very difficult, dose-area products of 90 patients undergoing cystourethrography examinations were recorded and used with two Monte Carlo codes, MCNP5 and PCXMC2.0, to assess the organ doses in these procedures. The organs receiving the highest radiation doses were the urinary bladder (ranging from 1.9 mSv in the newborn to 4.7 mSv in a 5-y old patient) and the large intestines (ranging from 1.5 mSv in the newborn to 3.1 mSv in the 5-y old patient). For all ages the main contributors to the total organ or effective doses are the fluoroscopy projections compared with the radiographs. There was a reasonable agreement between the dose estimates provided by PCXMC v2.0 and MCNP5 for most of the organs considered in this study. In special cases, there were systematic disagreements in organ doses such as in the skeleton, gonads and oesophagus due to the anatomical differences between patient anatomic models employed by the two codes.


Assuntos
Método de Monte Carlo , Doses de Radiação , Doenças da Bexiga Urinária/diagnóstico por imagem , Urografia/normas , Adolescente , Adulto , Criança , Pré-Escolar , Simulação por Computador , Feminino , Fluoroscopia/métodos , Humanos , Lactente , Recém-Nascido , Modelos Teóricos , Imagens de Fantasmas , Medição de Risco , Urografia/métodos
11.
Radiol Med ; 117(4): 654-68, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22095417

RESUMO

PURPOSE: We evaluated in vivo changes in lumbar lordosis and intervertebral discs in runners and assessed the relationship between these changes and degenerative disc disease in runners with and without a history of low back pain. MATERIALS AND METHODS: Using open upright magnetic resonance (MR) imaging, we prospectively studied changes in lumbar lordosis and intervertebral discs of 25 elite long-distance runners in two sitting postures (neutral and extended) before and after 1 h of running and compared the results with disc height and dehydration/degeneration. Seventeen of the 25 runners had a history of low back pain. RESULTS: After 1 h of running, mean lordosis in neutral posture reduced by 4°; reduction was significant in runners with a history of low back pain. A significant reduction in mean lordosis in extension was not observed. Mean disc height significantly reduced in both postures, without, however, any statistical significance between runners with and without a history low back pain in any posture. Variable degrees of disc dehydration/degeneration were observed in 23 runners (57 discs), more commonly at L5-S1. A significant difference of disc dehydration/degeneration between runners with and without a history of low back pain was not observed. CONCLUSIONS: Intervertebral discs undergo significant strain after 1 h of running that in the long term may lead to low back pain and degenerative disc disease. Runners, especially those with low back pain and degenerative disc disease, should be evaluated after training to preserve the normal lumbar lordosis.


Assuntos
Degeneração do Disco Intervertebral/diagnóstico , Disco Intervertebral/patologia , Lordose/diagnóstico , Dor Lombar/diagnóstico , Vértebras Lombares/patologia , Imageamento por Ressonância Magnética/métodos , Postura/fisiologia , Corrida , Adulto , Idoso , Distribuição de Qui-Quadrado , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
12.
Radiat Prot Dosimetry ; 147(1-2): 287-90, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21831865

RESUMO

Lung brachytherapy using high-dose rate (192)Ir technique is a well-established technique of radiation therapy. However, many commercial treatment planning systems do not have the ability to consider the inhomogeneity of lung in relation to normal tissue. Under such circumstances dose calculations for tissues and organs at risk close to the target are inaccurate. The purpose of the current study was to estimate the dose difference due to tissue inhomogeneity using the Monte Carlo simulation code MCNP-5. Results showed that there was a relative sub dosage by treatment planning systems calculations in neighbouring tissues around the radioactive source due to inhomogeneity ignorance. The presence of lung instead of normal tissue resulted in an increase in relative dose, which approached 8 % at 4-cm distance from the source. Additionally, the relative increase was small for the lung (2.1 %) and larger for organs at risk such as the heart (6.8 %) and bone marrow (7.6 %).


Assuntos
Braquiterapia , Radioisótopos de Irídio/uso terapêutico , Neoplasias Pulmonares/radioterapia , Método de Monte Carlo , Dosagem Radioterapêutica , Algoritmos , Medula Óssea/efeitos da radiação , Simulação por Computador , Coração/efeitos da radiação , Humanos , Imagens de Fantasmas , Radiometria , Planejamento da Radioterapia Assistida por Computador , Eficiência Biológica Relativa
13.
Radiat Prot Dosimetry ; 147(1-2): 78-82, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21733864

RESUMO

Patient dose measurements of local entrance dose to the skin have been carried out using radiochromic film (Gafchromic XR-RV2) in a sample of interventional procedures. The major aim of the work was to measure patient entrance dose from such examinations using Gafchromic XR-RV2. Forty-five various interventional procedures (including nefrostomies and urinary stenting, biliary stenting and percutaneous transhepatic biliary drainage (PTBD) and aorta stent grafting) were evaluated. Maximum entrance doses were 537 ± 119 mGy in nephrostomies, 943 ± 631 mGy in biliary stenting and PTBD and 2425 ± 569 mGy in aorta stent grafting. Results indicate that all patients undergoing aorta stent grafting received skin dose above 1500 mGy, which means that there is an increasing potential to suffer radiation-induced skin injuries. The film provides dose mapping, the position of the skin area with highest dose and can be used for immediate qualitative and as well as for quantitative assessment of patient skin dose.


Assuntos
Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Doses de Radiação , Radiografia Intervencionista , Pele/efeitos da radiação , Carga Corporal (Radioterapia) , Humanos , Pele/diagnóstico por imagem
14.
J Int Med Res ; 39(2): 569-79, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21672362

RESUMO

The lumbar spines of 25 long-distance runners were examined using an upright magnetic resonance imaging scanner. All volunteer runners were scanned before and after running for 1 h. Scanning was performed with the runners seated upright (neutral), leaning forwards (flexion) and leaning backwards (extension). All measured discs showed a reduction in disc height after 1 h of running. A significant reduction in disc height was observed in all three body positions (neutral, flexion and extension) after 1 h of running. The results showed that, in flexion, extension and neutral positions, intervertebral discs undergo significant strain after 1 h of running. The lowest disc-height reduction was found at the L5 - S1 space in the neutral position; the same space had the highest percentage of disc degeneration.


Assuntos
Atletas , Disco Intervertebral/fisiopatologia , Corrida/fisiologia , Adulto , Idoso , Estatura , Peso Corporal , Feminino , Humanos , Disco Intervertebral/patologia , Degeneração do Disco Intervertebral/complicações , Degeneração do Disco Intervertebral/patologia , Dor Lombar/complicações , Dor Lombar/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Adulto Jovem
15.
AJNR Am J Neuroradiol ; 32(7): 1295-300, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21680656

RESUMO

BACKGROUND AND PURPOSE: EPFs sustained during VCFs degrade the disk's ability to develop IDP under load. This inability to develop pressure in combination with residual kyphotic deformity increases the risk for adjacent vertebral fractures. We tested the hypothesis that StaXx FX reduces kyphosis and endplate deformity following vertebral compression fracture, restoring disk mechanics. MATERIALS AND METHODS: Eight thoracolumbar, 5-vertebrae segments were tested. A void was selectively created in the middle vertebra. The specimens were compressed until EPF and to a grade I-II VCF. PEEK wafer kyphoplasty was then performed. The specimens were then tested in flexion-extension (±6 Nm) under 400-N preload intact, after EPF, VCF, and kyphoplasty. Endplate deformity, kyphosis, and IDP adjacent to the fractured body were measured. RESULTS: Vertebral body height at the point of maximal endplate deformity decreased after EPF and VCF and was partially corrected after StaXx FX, remaining less than intact (P = .047). Anterior vertebral height decreased after VCF (P = .002) and was partially restored with StaXx FX, remaining less than intact (P = .015). Vertebral kyphosis increased after VCF (P < .001) and reduced after StaXx FX, remaining greater than intact (P = .03). EPF reduced IDP in the affected disk in compression-flexion loading (P < .001), which was restored after StaXx FX (P = 1.0). IDP in the unaffected disk did not change during testing (P > .3). CONCLUSIONS: StaXx FX reduced endplate deformity and kyphosis, and significantly increased anterior height following VCF. Although height and kyphosis were not fully corrected, the disk's ability to pressurize under load was restored.


Assuntos
Disco Intervertebral/cirurgia , Cetonas , Cifoplastia/métodos , Vértebras Lombares/cirurgia , Polietilenoglicóis , Fraturas da Coluna Vertebral/cirurgia , Vértebras Torácicas/cirurgia , Idoso , Benzofenonas , Materiais Biocompatíveis , Fenômenos Biomecânicos/fisiologia , Cadáver , Feminino , Fraturas por Compressão/fisiopatologia , Fraturas por Compressão/cirurgia , Humanos , Disco Intervertebral/fisiologia , Cifoplastia/instrumentação , Cifose/fisiopatologia , Cifose/cirurgia , Vértebras Lombares/fisiologia , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Polímeros , Amplitude de Movimento Articular/fisiologia , Fraturas da Coluna Vertebral/fisiopatologia , Vértebras Torácicas/fisiologia
16.
Phys Med Biol ; 56(2): 367-82, 2011 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-21178238

RESUMO

Organ doses are important quantities in assessing the radiation risk. In the case of children, estimation of this risk is of particular concern due to their significant radiosensitivity and the greater health detriment. The purpose of this study is to estimate the organ doses to paediatric patients undergoing barium meal and micturating cystourethrography examinations by clinical measurements and Monte Carlo simulation. In clinical measurements, dose-area products (DAPs) were assessed during examination of 50 patients undergoing barium meal and 90 patients undergoing cystourethrography examinations, separated equally within three age categories: namely newborn, 1 year and 5 years old. Monte Carlo simulation of photon transport in male and female mathematical phantoms was applied using the MCNP5 code in order to estimate the equivalent organ doses. Regarding the micturating cystourethrography examinations, the organs receiving considerable amounts of radiation doses were the urinary bladder (1.87, 2.43 and 4.7 mSv, the first, second and third value in the parentheses corresponds to neonatal, 1 year old and 5 year old patients, respectively), the large intestines (1.54, 1.8, 3.1 mSv), the small intestines (1.34, 1.56, 2.78 mSv), the stomach (1.46, 1.02, 2.01 mSv) and the gall bladder (1.46, 1.66, 2.18 mSv), depending upon the age of the child. Organs receiving considerable amounts of radiation during barium meal examinations were the stomach (9.81, 9.92, 11.5 mSv), the gall bladder (3.05, 5.74, 7.15 mSv), the rib bones (9.82, 10.1, 11.1 mSv) and the pancreas (5.8, 5.93, 6.65 mSv), depending upon the age of the child. DAPs to organ/effective doses conversion factors were derived for each age and examination in order to be compared with other studies.


Assuntos
Bário , Sistema Digestório/diagnóstico por imagem , Método de Monte Carlo , Doenças da Bexiga Urinária/diagnóstico por imagem , Urografia/métodos , Bário/administração & dosagem , Carga Corporal (Radioterapia) , Pré-Escolar , Simulação por Computador , Meios de Contraste/administração & dosagem , Sistema Digestório/patologia , Feminino , Fluoroscopia/métodos , Fluoroscopia/normas , Humanos , Lactente , Recém-Nascido , Masculino , Especificidade de Órgãos , Doses de Radiação , Proteção Radiológica , Uretra/diagnóstico por imagem , Uretra/patologia , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/patologia , Doenças da Bexiga Urinária/patologia , Urografia/normas
17.
Health Phys ; 97(6): 595-603, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19901594

RESUMO

Computed tomography provides high-resolution imaging of the human body. However, it contributes mainly to the doses on the population. Additionally, the fact that children are two to three times more sensitive to the x rays compared to the adults results in the increased need of taking action for the reduction of the dose regarding the computed tomography examinations. The first part of this paper presents the results of an investigation on the variation of doses to children while the second part compares those results with the European standards. This project took place in twelve hospitals distributed throughout the country. The weighted computed dose-index and the dose length product were calculated for four different age-categories (namely 0, 1, 5 and 10-year-old) and for the three most often examinations (brain, thorax and abdomen). Effective dose values were estimated using coefficients and patients' data. The measurements showed that only a few hospitals are taking into account the protocols regarding the age of the children. As a result, many patients receive high doses without this being necessary. Thus, reducing dose methods should be adapted in order to improve the optimization of this high dose modality.


Assuntos
Carga Corporal (Radioterapia) , Doses de Radiação , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Contagem Corporal Total/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Feminino , Grécia/epidemiologia , Humanos , Recém-Nascido , Masculino , Medição de Risco , Fatores de Risco , Adulto Jovem
18.
Anat Histol Embryol ; 38(4): 292-9, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19614630

RESUMO

Seventy-three clinically normal, lactating cats were used to investigate the lymph drainage of 73 mammary glands. In 50 cats of the first group, the number of lymphatic vessels emerging from the examined mammary gland, their course and the lymph nodes into which they are drained were studied by indirect lymphography (IL) after intramammary injection of an oily contrast medium. In 23 cats of the second group, the lymph drainage of the mammary glands was studied by computerized tomography indirect lymphography (CT-IL) after intramammary injection of a water soluble contrast medium. The following day, the lymph drainage of the mammary gland examined by CT-IL was studied by IL, as it was described in the first group, for comparison purposes. The main conclusions drawn after this study were as follows: lymph drains from the first and second mammary glands with one or rarely two or three lymphatic vessels to the accessory axillary lymph nodes. Lymph drains from the third mammary gland with one or two and rarely three lymphatic vessels usually to the accessory inguinal lymph nodes or to the accessory axillary lymph nodes. In some cases, it drains to both lymph nodes simultaneously or it may rarely drain only to the medial iliac lymph nodes. The fourth mammary gland with one or two and rarely three lymphatic vessels usually drains to the accessory inguinal lymph nodes. It may rarely drain only to the medial iliac lymph nodes. Mammary lymphatic vessels that cross the midline and lymphatic connection between the mammary glands were not demonstrated. No differences in the mammary lymph drainage pattern between IL and CT-IL were found.


Assuntos
Gatos/anatomia & histologia , Sistema Linfático/anatomia & histologia , Glândulas Mamárias Animais/anatomia & histologia , Animais , Axila , Meios de Contraste/administração & dosagem , Feminino , Virilha , Óleo Iodado/administração & dosagem , Lactação , Linfonodos/anatomia & histologia , Linfonodos/diagnóstico por imagem , Linfografia/veterinária , Tomografia Computadorizada por Raios X/veterinária
19.
Eur J Radiol ; 69(2): 253-9, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18182266

RESUMO

Spontaneous intracranial hypotension (SIH) is an uncommon but increasingly recognized syndrome. Orthostatic headache with typical findings on magnetic resonance imaging (MRI) are the key to diagnosis. Delayed diagnosis of this condition may subject patients to unnecessary procedures and prolong morbidity. We describe six patients with SIH and outline the important clinical and neuroimaging findings. They were all relatively young, 20-54 years old, with clearly orthostatic headache, minimal neurological signs (only abducent nerve paresis in two) and diffuse pachymeningeal gadolinium enhancement on brain MRI, while two of them presented subdural hygromas. Spinal MRI was helpful in detecting a cervical cerebrospinal fluid leak in three patients and dilatation of the vertebral venous plexus with extradural fluid collection in another. Conservative management resulted in rapid resolution of symptoms in five patients (10 days-3 weeks) and in one who developed cerebral venous sinus thrombosis, the condition resolved in 2 months. However, this rapid clinical improvement was not accompanied by an analogous regression of the brain MR findings that persisted on a longer follow-up. Along with recent literature data, our patients further point out that SIH, to be correctly diagnosed, necessitates increased alertness by the attending physician, in the evaluation of headaches.


Assuntos
Hipotensão Intracraniana/complicações , Hipotensão Intracraniana/diagnóstico , Imageamento por Ressonância Magnética/métodos , Derrame Subdural/diagnóstico , Derrame Subdural/etiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
Ultrasound Obstet Gynecol ; 32(6): 819-27, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18951545

RESUMO

OBJECTIVES: This study was conducted to assess the role of pelvic ultrasound variables in discriminating between normal girls and girls with different forms of sexual precocity, and to establish reliable cut-off limits of pelvic ultrasound measurements for differentiating between these conditions. METHODS: Eighty-eight girls with different forms of sexual precocity (23 with premature thelarche, 15 with premature pubarche and 50 with central precocious puberty) were enrolled. All diagnoses were based on clinical examination with confirmation using the gonadotropin-releasing hormone-stimulation test. Additionally, 81 prepubertal girls, aged 0-10 years, were included as a control group. For statistical analysis and to facilitate comparisons, the groups were subdivided by age intervals (0-6, > 6-8 and > 8-10 years). All subjects underwent pelvic ultrasound examination for the measurement of uterine length, uterine volume, ovarian volume and the anteroposterior diameter at the fundus divided by the anteroposterior diameter at the cervix (fundal/cervical ratio, (F/C)). Finally, the morphological appearance of the ovaries was assessed. RESULTS: Patients with central precocious puberty had significantly higher values for all the ultrasound variables (with the exception of uterine length in the 1-6-year age group) in comparison to normal girls. Patients with premature thelarche and patients with premature pubarche showed similar pelvic ultrasound parameters to those of normal girls. Ovarian volume was the best parameter for identifying patients with central precocious puberty (a cut-off of 3.04 cm(3) had a sensitivity of 100% and a specificity of 97.1% for age interval 0-6 years, a cut-off of 3.35 cm(3) had a sensitivity of 100% and a specificity of 89.5% for age interval > 6-8 years, and a cut-off of 4.46 cm(3) had a sensitivity of 80.8% and a specificity of 88.5% for age interval > 8-10 years). Uterine length was the best parameter for distinguishing between patients with central precocious puberty and patients with premature thelarche (a cut-off of 3.185 cm had a sensitivity of 85.7% and a specificity of 91.7% for age interval 0-6 years, and a cut-off of 3.83 cm had a sensitivity of 82.4% and a specificity of 90.9% for age interval > 6-8 years). CONCLUSIONS: Ultrasound examination of the uterus and ovaries could serve as a complementary tool for the diagnosis of central precocious puberty and, consequently, for the early initiation of appropriate treatment.


Assuntos
Hormônio Liberador de Gonadotropina/uso terapêutico , Puberdade Precoce/diagnóstico por imagem , Análise de Variância , Estatura , Criança , Pré-Escolar , Feminino , Hormônio Liberador de Gonadotropina/agonistas , Humanos , Lactente , Recém-Nascido , Ovário/diagnóstico por imagem , Pelve/diagnóstico por imagem , Curva ROC , Sensibilidade e Especificidade , Ultrassonografia Mamária , Útero/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...