Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
Sensors (Basel) ; 24(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38894309

RESUMO

In this study, we investigate the potential of cold atmospheric plasma (CAP) as a non-contact excitation device, comparing its performance with an ultrasound transmitter. Utilizing a scanning Laser Doppler Vibrometer (LDV), we visualize the acoustic wavefront generated by a CAP probe and an ultrasound sensor within a designated 50 mm × 50 mm area in front of each probe. Our focus lies in assessing the applicability of a CAP probe for exciting a small polymethyl methacrylate (PMMA) sample. By adjusting the dimensions of the sample to resonate at the excitation frequency of the probe, we can achieve high vibrational velocities, enabling further mechanical analysis. In contrast with traditional vibration excitation techniques such as electrodynamical shakers and hammer impact excitation, a plasma probe can offer distinct advantages without altering the structure's dynamics since it is contactless. Furthermore, in comparison with laser excitation, plasma excitation provides a higher power level. Additionally, while pressurized air systems are applicable for limited low frequencies, plasma probes can perform at higher frequencies. Our findings in this study suggest that CAP is comparable with acoustic excitation, indicating its potential as an effective mechanical excitation method.

2.
Biomater Adv ; 159: 213827, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38490018

RESUMO

Chronic suppurative otitis media (CSOM) is often associated with permanent tympanic membrane (TM) perforation and conductive hearing loss. The current clinical gold standard, using autografts and allografts, suffers from several drawbacks. Artificial replacement materials can help to overcome these drawbacks. Therefore, scaffolds fabricated through digital light processing (DLP) were herein created to support TM regeneration. Various UV-curable printing inks, including gelatin methacryloyl (GelMA), gelatin-norbornene-norbornene (GelNBNB) (crosslinked with thiolated gelatin (GelSH)) and alkene-functionalized poly-ε-caprolactone (E-PCL) (crosslinked with pentaerythritol tetrakis(3-mercaptopropionate) (PETA4SH)) were optimized regarding photo-initiator (PI) and photo-absorber (PA) concentrations through viscosity characterization, photo-rheology and the establishment of working curves for DLP. Our material platform enabled the development of constructs with a range of mechanical properties (plateau storage modulus varying between 15 and 119 kPa). Excellent network connectivity for the GelNBNB and E-PCL constructs was demonstrated (gel fractions >95 %) whereas a post-crosslinking step was required for the GelMA constructs. All samples showed excellent biocompatibility (viability >93 % and metabolic activity >88 %). Finally, in vivo and ex vivo assessments, including histology, vibration and deformation responses measured through laser doppler vibrometry and digital image correlation respectively, were performed to investigate the effects of the scaffolds on the anatomical and physiological regeneration of acute TM perforations in rabbits. The data showed that the most efficient healing with the best functional quality was obtained when both mechanical (obtained with the PCL-based resin) and biological (obtained with the gelatin-based resins) material properties were taken into account.


Assuntos
Perfuração da Membrana Timpânica , Membrana Timpânica , Animais , Coelhos , Gelatina , Sinais (Psicologia) , Perfuração da Membrana Timpânica/cirurgia , Regeneração , Norbornanos
3.
Hear Res ; 437: 108840, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37423028

RESUMO

While the presence of residual stress (also called prestress) in the tympanic membrane (TM) was hypothesized more than 150 years ago by von Helmholtz (1869), little experimental data exists to date. In this paper, a novel approach to study residual stress is presented. Using a pulsed laser, the New Zealand white rabbit TM is perforated at seven predefined locations. The subsequent retraction of the membrane around the holes is computed using digital image correlation (DIC). The amount of retraction is the so-called prestrain, which is caused by the release of prestress due to the perforation. By measuring the prestrain using DIC, we show that residual stress is clearly present over the entire rabbit TM surface. In total, fourteen TMs have been measured in this work. An automated approach allows tracking the holes' deformation during the measurement process and enables a more robust analysis than was previously possible. We find similar strains (around 5%) as reported in previous work, in which slits were created manually using flattened surgical needles. However, the new approach greatly reduces measurement time, which minimizes dehydration artifacts. To investigate the effect of perforation location on the TM, the spatial decrease of the prestrain (α) around the perforation was quantified. Perforations inferior to the umbo showed the least negative α values, i.e., the most gradual decrease around the hole, and were the most consistent. Perforations on other locations showed more negative α values, i.e., steeper decrease in strain, but were less consistent across samples. We also investigated the effect of the holes' creation sequence but did not observe a significant change in the results. Overall, the presented method allows for consistent residual stress measurements over the TM surface. The findings contribute to our fundamental knowledge of the mechanics of the rabbit TM and provide a basis for future work on human TMs.


Assuntos
Perfuração da Membrana Timpânica , Membrana Timpânica , Coelhos , Humanos , Animais
4.
J Acoust Soc Am ; 153(2): 921, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36859143

RESUMO

To investigate the acoustics of reed instruments without the need for a human player, blowing machines are needed, which can generate air pressures up to 8 kPa and flow rates up to 40 liters per minute. Due to reed flexibility and the changing pressure gradient across the reed, the relationship between flow and pressure is highly non-linear. Since the output pressure of ventilators is highly dependent on flow, non-linear pressure regulation is a difficult task that requires a closed-loop approach. Since reed vibration starts suddenly when blowing pressure is gradually increased, an abrupt change in airflow through the instrument is present, resulting in a change in pressure in the artificial mouth. To avoid that, a method is presented to achieve a fast response to abrupt flow changes, which is tested in an existing blowing machine. The enhanced blowing machine exhibits a settling time below 200 ms, which allows for the generation of blowing pressures with linear responses.

5.
Comput Biol Med ; 157: 106747, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36907036

RESUMO

Finite element (FE) models of the middle ear often lack accurate geometry of soft tissue structures, such as the suspensory ligaments, as they can be difficult to discern using conventional imaging modalities, such as computed tomography. Synchrotron-radiation phase-contrast imaging (SR-PCI) is a non-destructive imaging modality that has been shown to produce excellent visualization of soft tissue structures without the need for extensive sample preparation. The objectives of the investigation were to firstly use SR-PCI to create and evaluate a biomechanical FE model of the human middle ear that includes all soft tissue structures, and secondly, to investigate how modelling assumptions and simplifications of ligament representations affect the simulated biomechanical response of the FE model. The FE model included the suspensory ligaments, ossicular chain, tympanic membrane, the incudostapedial and incudomalleal joints, and the ear canal. Frequency responses obtained from the SR-PCI-based FE model agreed well with published laser doppler vibrometer measurements on cadaveric samples. Revised models with exclusion of the superior malleal ligament (SML), simplification of the SML, and modification of the stapedial annular ligament were studied, as these revised models represented modelling assumptions that have been made in literature.


Assuntos
Intervenção Coronária Percutânea , Síncrotrons , Humanos , Análise de Elementos Finitos , Orelha Média/diagnóstico por imagem , Orelha Média/fisiologia , Estribo/fisiologia
6.
Hear Res ; 429: 108701, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36680871

RESUMO

Knowing the precise tympanic membrane (TM) thickness variation is crucial in understanding the functional properties of the TM and has a significant effect on the accuracy of computational models. Using optical coherence tomography, we imaged five left and five right TMs of domestic New Zealand rabbits. From these data, ten thickness distribution maps were computed. Although inter-specimen variability is present, similar features could be observed in all samples: The rabbit TM is thickest around the umbo, with values of 150 ± 32 µm. From the umbo towards the TM annulus, the thickness gradually decreases down to 38 ± 7 µm around the midway location, but increases up to 54 ± 19 µm at the TM annulus. The thickness values at the umbo are comparable to literature data for humans, but the rabbit TM is thinner at the TM annulus and in-between the umbo and annulus. Moreover, the rabbit TM thickness distribution is highly symmetrical, which is not the case for the human TM. The results improve our general understanding of TM structure in rabbits and may improve numerical models of TM dynamical behavior.


Assuntos
Perfuração da Membrana Timpânica , Membrana Timpânica , Coelhos , Humanos , Animais , Membrana Timpânica/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos
7.
Hear Res ; 426: 108537, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35672191

RESUMO

Positioning of the cochlear implant (CI) electrode in relation to the anatomical structures is a key factor for the hearing outcome and the preservation of residual hearing after cochlear implantation. Determining the exact electrode's location is therefore expected to play an important role in optimisation of the electrode design, the surgical techniques and the post-operative device fitting. The aim of this study is the development and validation of a robust and efficient computerised algorithm for three-dimensional (3D) localisation of the CI-electrode contacts with respect to the relevant cochlear structures, such as the basilar membrane and the modiolus, from modern clinical in vivo cone-beam computed tomography (CBCT). In the presented algorithm, the pre- and post-implantation CBCT are spatially aligned. To localise the anatomical structures, a cochlear microanatomical template derived from lab-based X-ray computed microtomography (µCT) measurements is warped to match the patient-specific cochlear shape acquired from pre-implantation CBCT. The electrode-contact locations, determined from the post-operative CBCT, are superimposed onto the cochlear fine-structure of the microanatomical template to localise the array. The accuracy of this method was validated in a temporal bone study by comparing the distance of the electrode contacts from the modiolar wall, as derived by the algorithm from CBCTs, with the distance determined from synchrotron-radiation (SR) µCT on the same specimens. Due to the achievable spatial resolution, good tissue contrast and limited presence of metallic artifacts, the SRµCT technique is considered to be a golden standard in the proposed approach. In contrast to other approaches, this validation method allowed for the evaluation of the final electrode-to-modiolus distance (EMD) error, and covers the error in co-alignment of the images, in the determination of the electrode contact location and in the localisation of the cochlear structures. The absolute mean error on the EMD parameter was determined at 0.11 mm (max = 0.29 mm, SD = 0.07 mm) across five samples, slightly lower than the voxel size of the CBCT-scans. In a retrospective study, the algorithm was applied to identify scalar translocations of the electrode from clinical in vivo CBCT datasets of 23 CI-recipients, which showed perfect (100%) agreement with the blinded opinion of two experienced neuroradiologists.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Estudos Retrospectivos , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos
8.
J Mech Behav Biomed Mater ; 131: 105261, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35561598

RESUMO

Experiments have shown that prestrain exists in the rabbit tympanic membrane (TM), also in the absence of external loads. To date, it is unclear how prestrain influences the vibration response of the middle ear (ME). In this study, a detailed 3D finite-element model of the rabbit ME was constructed based on experimentally validated material properties. The model incorporates different degrees of prestrain in the TM and simulates the ME vibration response to sound as a linear harmonic perturbation around the prestressed reference state. To account for finite deformations associated with large prestrains, a framework was developed that iteratively updates the initial unstrained geometry until the prestrained geometry is in agreement with the given reference geometry. After validating the model using quasi-static and acoustic measurement data, it was shown that small levels of prestrain already have a substantial impact on the normal umbo and footplate response due to a phenomenon known as prestress stiffening. Although the approach is not preferable, it was possible to replicate the effect of prestrain in the normal ME by appropriately scaling the elastic moduli and damping factors in the base model. To evaluate the effect of possible changes in TM prestrain when the normal state of the ear is altered due to pathological modifications in the ME structure, we created a model with a perforation in the TM. It was shown that the change in vibration response after perforation is affected at low frequencies by a release of TM prestrain. In future studies, it may be necessary to incorporate prestrain in ME models to better understand the function of the diseased or reconstructed ME, which may be relevant for the development of reconstructive tissue grafts in the middle ear.


Assuntos
Orelha Média , Membrana Timpânica , Animais , Orelha Média/fisiologia , Módulo de Elasticidade , Análise de Elementos Finitos , Coelhos , Som , Vibração
9.
J Biomech Eng ; 144(3)2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34505875

RESUMO

Characterization of material parameters from experimental data remains challenging, especially on biological structures. One of such techniques allowing for the inverse determination of material parameters from measurement data is the virtual fields method (VFM). However, application of the VFM on general structures of complicated shape has not yet been extensively investigated. In this paper, we extend the framework of the VFM method to thin curved solids in three-dimensional, commonly denoted shells. Our method is then used to estimate the Young's modulus and hysteretic damping of the human eardrum. By utilizing Kirchhoff plate theory, we assume that the behavior of the shell varies linearly through the thickness. The total strain of the shell can then be separated in a bending and membrane strain. This in turn allowed for an application of the VFM based only on data of the outer surface of the shell. We validated our method on simulated and experimental data of a human eardrum made to vibrate at certain frequencies. It was shown that the identified material properties were accurately determined based only on data from the outer surface and are in agreement with literature. Additionally, we observed that neither the bending nor the membrane strain in an human eardrum can be neglected and both contribute significantly to the total strain found experimentally.


Assuntos
Membrana Timpânica , Módulo de Elasticidade , Humanos
10.
J Acoust Soc Am ; 150(5): 3730, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34852612

RESUMO

In single reed musical instruments, vibrations of the reed, in conjunction with the geometry of the mouthpiece and the acoustic feedback of the instrument, play an essential role in sound generation. Up until now, three-dimensional (3D) reed vibration patterns have only been studied under external acoustic stimulation, or at a single note and lip force. This paper investigates vibration patterns of saxophone reeds under imitated realistic playing conditions. On different notes displacement measurements on the entire optically accessible part of the reed are performed using stroboscopic digital image correlation. These vibration data are decomposed onto the harmonic frequencies of the generated note pitch and into the operational modes. Motion data as a function of time are shown on single points. All points on the reed predominantly move in phase, corresponding to the first flexural mode of the reed. At higher note harmonics very low amplitude higher vibration modes are superimposed on the fundamental mode. Mouthpiece characteristics and lip force influence the vibration patterns. Vibration patterns differ strongly from earlier measurements on free vibrating reeds. Results show that single-point measurements on the tip of the reed can give a good indication of the 3D vibration amplitude, also at higher note pitches.

11.
Hear Res ; 412: 108392, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34800801

RESUMO

Prestrain in the absence of external loads can have an important effect on the vibrational behavior of mechanical systems such as the middle ear. Studies that measure tympanic membrane (TM) prestrain are scarce, however, and provide no conclusive answer on the existence and nature of the prestrain. In this study, prestrain is measured in the TM of cadaveric rabbit ears by stereo digital image correlation. To release the prestrain, straight incisions of 0.33 mm are made on different locations in the TM with a direction parallel to either the radial or circular fibers in the membrane. The effect of sample dehydration during different stages in the experimental procedure is assessed and eliminated by rehydrating the samples directly before each measurement. The measurements demonstrate average prestrain values around the incisions between 3.52±2.34% and 13.62±7.92% for the different locations, with a noise floor of 0.07%. No clear differences were found between the prestrain values obtained for radial and circular incisions. Observed local variations in TM prestrain could not be clearly related to specific locations on the TM. The results suggest that TM prestrain may need to be considered in future studies of middle-ear function if the findings can be confirmed in human ears.


Assuntos
Orelha Média , Membrana Timpânica , Animais , Coelhos , Membrana Timpânica/diagnóstico por imagem , Membrana Timpânica/cirurgia , Vibração
12.
J Imaging ; 7(3)2021 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-34460710

RESUMO

Compared to single source systems, stereo X-ray CT systems allow acquiring projection data within a reduced amount of time, for an extended field-of-view, or for dual X-ray energies. To exploit the benefit of a dual X-ray system, its acquisition geometry needs to be calibrated. Unfortunately, in modular stereo X-ray CT setups, geometry misalignment occurs each time the setup is changed, which calls for an efficient calibration procedure. Although many studies have been dealing with geometry calibration of an X-ray CT system, little research targets the calibration of a dual cone-beam X-ray CT system. In this work, we present a phantom-based calibration procedure to accurately estimate the geometry of a stereo cone-beam X-ray CT system. With simulated as well as real experiments, it is shown that the calibration procedure can be used to accurately estimate the geometry of a modular stereo X-ray CT system thereby reducing the misalignment artifacts in the reconstruction volumes.

13.
Phys Med Biol ; 66(16)2021 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-34289457

RESUMO

An issue in computerized x-ray tomography is the limited size of available detectors relative to objects of interest. A solution was provided in the past two decades by positioning the detector in a lateral offset position, increasing the effective field of view (FOV) and thus the diameter of the reconstructed volume. However, this introduced artifacts in the obtained reconstructions, caused by projection truncation and data redundancy. These issues can be addressed by incorporating an additional data weighting step in the reconstruction algorithms, known as redundancy weighting. In this work, we present an implementation of redundancy weighting in the widely-used simultaneous iterative reconstruction technique (SIRT), yielding the weighted SIRT (W-SIRT) method. The new technique is validated using geometric phantoms and a rabbit specimen, by performing both simulation studies as well as physical experiments. The experiments are carried out in a highly flexible stereoscopic x-ray system equipped with x-ray image intensifiers (XRIIs). The simulations showed that higher values of contrast-to-noise ratio could be obtained using the W-SIRT approach as compared to a weighted implementation of the simultaneous algebraic reconstruction technique (SART). The convergence rate of the W-SIRT was accelerated by including a relaxation parameter in the W-SIRT algorithm, creating the aW-SIRT algorithm. This allowed to obtain the same results as the W-SIRT algorithm, but at half the number of iterations, yielding a much shorter computation time. The aW-SIRT algorithm has proven to perform well for both large as well as small regions of overlap, outperforming the pre-convolutional Feldkamp-David-Kress algorithm for small overlap regions (or large detector offsets). The experiments confirmed the results of the simulations. Using the aW-SIRT algorithm, the effective FOV was increased by >75%, only limited by experimental constraints. Although an XRII is used in this work, the method readily applies to flat-panel detectors as well.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador , Algoritmos , Animais , Imagens de Fantasmas , Coelhos , Tomografia Computadorizada por Raios X , Raios X
14.
J Synchrotron Radiat ; 28(Pt 1): 327-332, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33399585

RESUMO

Recently, synchrotron radiation computed microtomography (SRµCT) has emerged as a promising tool for non-destructive, in situ visualization of cochlear implant electrode arrays inserted into a human cochlea. Histological techniques have been the `gold standard' technique for accurate localization of cochlear implant electrodes but are suboptimal for precise three-dimensional measurements. Here, an SRµCT experimental setup is proposed that offers the benefit of a high spatial and contrast resolution (isotropic voxel size = 4.95 µm and propagation-based phase-contrast imaging), while visualizing the soft-tissue structures and electrode array of the cochlear implant simultaneously. In this work, perimodiolar electrode arrays have been tested, which incorporate thick and closely spaced platinum-iridium contacts and wiring. These data can assist cochlear implant and hearing research, can be used to verify electrode segmentation techniques for clinical computed tomography or could be utilized to evaluate cochlear implant electrode array designs.


Assuntos
Cóclea/anatomia & histologia , Implantes Cocleares , Osso Temporal/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Eletrodos Implantados , Humanos , Imageamento Tridimensional , Técnicas In Vitro , Interpretação de Imagem Radiográfica Assistida por Computador , Síncrotrons
15.
Hear Res ; 400: 108116, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33291007

RESUMO

The vibration response of the middle ear (ME) to sound changes when static pressure gradients are applied across the tympanic membrane (TM). To date, it has not been well understood which mechanisms lead to these changes in ME vibration response. In this study, a 3D finite-element model of the human ME was developed that simulates the sound-induced ME vibration response when positive and negative static pressures of up to 4 kPa are applied to the TM. Hyperelasticity of the soft-tissue components was considered to simulate large deformations under static pressure. Some ME components were treated as viscoelastic materials to capture the difference between their static and dynamic stiffness, which was needed to replicate both static and dynamic ME behavior. The change in dynamic stiffness with static preload was simulated by linearization of the hyperelastic constitutive model around the predeformed state. For the preloaded harmonic response, we found that the statically deformed ME geometry introduced asymmetry in the vibration loss between positive and negative pressure, which was due to the TM cone shape. As opposed to previous assumptions, the prestress in the ME due to static pressure had a substantial impact on the vibration response. We also found that material nonlinearity led to a higher stiffening at the umbo but a less pronounced stiffening at the footplate compared to the linear elastic condition. The results suggest that flexibility of the incudomalleolar joint (IMJ) enhances the decoupling of static umbo and footplate displacements, and that viscosity and viscoelasticity of the IMJ could play a role in the transfer of sound-induced vibrations from the umbo to the footplate. The components of the incudostapedial joint had minimal effect on ME mechanical behavior.


Assuntos
Orelha Média , Análise de Elementos Finitos , Humanos , Pressão , Som , Membrana Timpânica , Vibração
16.
Materials (Basel) ; 13(20)2020 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-33066637

RESUMO

The reed is the primary component in single-reed woodwind instruments to generate the sound. The airflow of the player's mouth is the energy source and the airflow is modulated by the reed. The oscillations of the reed control the airflow. Traditionally, instrument reeds are made out of natural cane (Arundo Donax), but in efforts to overcome variability problems, synthetic reeds have been introduced. Previous investigations mainly focused on natural cane reeds and direct elasticity measurements did not discriminate between elasticity moduli along different directions. In order to obtain the mechanical properties along the direction of the reed fibres and in the orthogonal direction separately, a three-point bending testing setup was developed, which accommodates the small samples that can be cut from an instrument reed. Static moduli of elasticity were acquired in both directions. Much higher ratios between longitudinal and transversal moduli were seen in the natural cane reed as compared to the artificial reeds. Wet natural reeds showed a strong decrease in moduli of elasticity as compared to dry reeds. Elasticity was significantly higher in artificial reeds. The force-displacement curves of the wet natural reed show hysteresis, whereas the artificial materials did not. In the cane reed, higher energy losses were found in the transversal direction compared to the longitudinal direction.

17.
Otol Neurotol ; 41(4): 537-544, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32176145

RESUMO

OBJECTIVE: We compared the sound transmission using different types of total ossicular replacement prostheses (TORP); we then studied the performance of a new TORP that we designed inspired by the columella, the single ossicle found in birds. METHODS: Stapedial vibrations were measured on nine freshly frozen human temporal bones with laser Doppler vibrometry. We then compared the performances of eight common TORP positions or designs as well as the new silver prototype of bird-type prosthesis, designed also according to our digital holography patterns of the human tympanic membrane (TM). RESULTS: The TORPs placed in lateral contact with both the TM and the malleus handle outperformed, at most frequencies, those placed only in contact with the TM.The new bird-type prosthesis performed equally well or better than all other prostheses. CONCLUSION: If the malleus handle can be retained when placing a TORP, the best sound transmission can be achieved by placing the TORP in contact with both the distal part of the malleus handle and the TM. The good performance of our bird-type prosthesis suggests that there is still room for future improvement of prosthesis design to further optimize hearing outcomes after surgery.


Assuntos
Prótese Ossicular , Substituição Ossicular , Humanos , Lasers , Martelo/cirurgia , Osso Temporal/diagnóstico por imagem , Osso Temporal/cirurgia
18.
Comput Biol Med ; 117: 103600, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32072966

RESUMO

In this paper, we investigate the heating function of the nasal cavity qualitatively, using a high-quality, large-scale statistical shape model. This model consists of a symmetrical and an asymmetrical part and provides a new and unique way of examining changes in nasal heating function resulting from natural variations in nasal shape (as obtained from 100 clinical CT scans). Data collected from patients suffering from different nasal or sinus-related complaints are included. Parameterized models allow us to investigate the effect of continuous deviations in shape from the mean nasal cavity. This approach also enables us to avoid many of the compounded effects on flow and heat exchange, which one would encounter when comparing different patient-specific models. The effects of global size, size-related features, and turbinate size are investigated using the symmetrical shape model. The asymmetrical model is used to investigate different types of septal deviation using Mladina's classification. The qualitative results are discussed and compared with findings from the existing literature.


Assuntos
Septo Nasal , Conchas Nasais , Simulação por Computador , Humanos , Modelos Estatísticos , Cavidade Nasal/diagnóstico por imagem , Tomografia Computadorizada por Raios X
19.
Hear Res ; 387: 107877, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31958745

RESUMO

The eardrum is the primary component of the middle ear and has been extensively investigated in humans. Measuring the displacement and deformation of the eardrum under different quasi-static loading conditions gives insight in its mechanical behavior and is fundamental in determining the material properties of the eardrum. Currently, little is known about the behavior and material properties of eardrums in non-mammals. To explore the mechanical properties of the eardrum in non-mammalian ears, we investigated the quasi-static response of the eardrum of a common lizard: the Tokay gecko (Gekko gecko). The middle ear cavity was pressurized using repetitive linear pressure cycles ranging from -1.5 to 1.5 kPa with pressure change rates of 0.05, 0.1 and 0.2 kPa/s. The resulting shape, displacement and in-plane strain of the eardrum surface were measured using 3D digital image correlation. When middle-ear pressure is negative, the medial displacement of the eardrum is much larger than the displacement observed in mammals; when middle-ear pressure is positive, the lateral displacement is much larger than in mammals, which is not observed in bird single-ossicle ears. Peak-to-peak displacements are about 2.8 mm, which is larger than in any other species measured up to date. The peak-to-peak displacements are at least five times larger than observed in mammals. The pressure-displacement curves show hysteresis, and the energy loss within one pressure cycle increases with increasing pressure rate, contrary to what is observed in rabbit eardrums. The energy lost during a pressure cycle is not constant over the eardrum. Most energy is lost at the region where the eardrum connects to the hearing ossicle. Around this eardrum-ossicle region, a 5% increase in energy loss was observed when pressure change rate was increased from 0.05 kPa/s to 0.2 kPa/s. Other parts of the eardrum showed little increase in the energy loss. The orientation of the in-plane strain on the eardrum was mainly circumferential with strain amplitudes of about +1.5%. The periphery of the measured eardrum surface showed compression instead of stretching and had a different strain orientation. The TM of Gekko gecko shows the highest displacements of all species measured up till now. Our data show the first shape, displacement and deformation measurements on the surface of the eardrum of the gecko and indicate that there could exist a different hysteresis behavior in different species.


Assuntos
Audição , Lagartos/fisiologia , Membrana Timpânica/fisiologia , Animais , Pressão , Especificidade da Espécie , Estresse Mecânico
20.
Biomech Model Mechanobiol ; 19(1): 233-249, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31372910

RESUMO

It is believed that non-mammals have poor hearing at high frequencies because the sound-conduction performance of their single-ossicle middle ears declines above a certain frequency. To better understand this behavior, a dynamic three-dimensional finite-element model of the chicken middle ear was constructed. The effect of changing the flexibility of the cartilaginous extracolumella on middle-ear sound conduction was simulated from 0.125 to 8 kHz, and the influence of the outward-bulging cone shape of the eardrum was studied by altering the depth and orientation of the eardrum cone in the model. It was found that extracolumella flexibility increases the middle-ear pressure gain at low frequencies due to an enhancement of eardrum motion, but it decreases the pressure gain at high frequencies as the bony columella becomes more resistant to extracolumella movement. Similar to the inward-pointing cone shape of the mammalian eardrum, it was shown that the outward-pointing cone shape of the chicken eardrum enhances the middle-ear pressure gain compared to a flat eardrum shape. When the outward-pointing eardrum was replaced by an inward-pointing eardrum, the pressure gain decreased slightly over the entire frequency range. This decrease was assigned to an increase in bending behavior of the extracolumella and a reduction in piston-like columella motion in the model with an inward-pointing eardrum. Possibly, the single-ossicle middle ear of birds favors an outward-pointing eardrum over an inward-pointing one as it preserves a straight angle between the columella and extrastapedius and a right angle between the columella and suprastapedius, which provides the optimal transmission.


Assuntos
Galinhas/anatomia & histologia , Ossículos da Orelha/anatomia & histologia , Orelha Média/anatomia & histologia , Modelos Anatômicos , Som , Membrana Timpânica/anatomia & histologia , Animais , Simulação por Computador , Análise de Elementos Finitos , Maleabilidade , Pressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...