Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 9(1): 12332, 2019 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-31481668

RESUMO

The Montreal Protocol on Substances that Deplete the Ozone Layer has been hailed as the most successful environmental treaty ever ( https://www.unenvironment.org/news-and-stories/story/montreal-protocol-triumph-treaty ). Yet, although our main concern about ozone depletion is the subsequent increase in harmful solar UV radiation at the Earth's surface, no studies to date have demonstrated its effectiveness in that regard. Here we use long-term UV Index (UVI) data derived from high-quality UV spectroradiometer measurements to demonstrate its success in curbing increases in UV radiation. Without this landmark agreement, UVI values would have increased at mid-latitude locations by approximately 20% between the early 1990s and today and would approximately quadruple at mid-latitudes by 2100. In contrast, an analysis of UVI data from multiple clean-air sites shows that maximum daily UVI values have remained essentially constant over the last ~20 years in all seasons, and may even have decreased slightly in the southern hemisphere, especially in Antarctica, where effects of ozone depletion were larger. Reconstructions of the UVI from total ozone data show evidence of increasing UVI levels in the 1980s, but unfortunately, there are no high-quality UV measurements available prior to the early 1990s to confirm these increases with direct observations.

2.
Appl Opt ; 47(33): 6142-50, 2008 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-19023377

RESUMO

Combined measurements of diffuse-to-global radiation ratio and global spectral irradiances in the UV are used to derive cosine-corrected UV irradiances and aerosol optical depth (AOD). The diffuse-to-global radiation ratio is used first in the cosine correction of the global irradiance, then to calculate absolutely calibrated direct irradiances. The Beer-Lambert law is applied to derive the UV AOD using independent measurements of the extraterrestrial solar flux. The AOD can be derived with an uncertainty of about 0.03 at 60 degrees solar zenith angle. The method was applied to measurements obtained with two UV multifilter rotating shadowband radiometers (UV-MFRSRs) and a MK III Brewer spectrophotometer on the Island of Lampedusa in the Central Mediterranean during two periods of 2002 and 2004. The derived AOD at 318 and 332 nm was compared with UV AOD measured at 318, 320, and 368 nm with different techniques. The retrieved AOD, combining MFRSR and Brewer measurements, is in good agreement with the optical depth derived with the other methods.

3.
Photochem Photobiol ; 76(1): 64-72, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12126309

RESUMO

A system to determine the spectral responsivity of ultraviolet (UV) radiometers has been developed and is routinely operated at the Central Ultraviolet Calibration Facility, at the National Oceanic and Atmospheric Administration. The instrument and the measurement methodologies are described. Results of measurements from thermally controlled broadband UV radiometers of the Robertson-Berger (R-B)-type are described. Systematic differences in the spectral response curves for these instruments have been detected. The effect of these differences on the field operation of UV-B radiometers has been studied by calculating the instrumental response from modeled UV spectra. The differences of the weighted spectral UV irradiances, measured by two radiometers with different spectral response functions, caused by the daily variation in the position of the sun were estimated for fixed values of total ozone, altitude and albedo, and for cloud-free conditions. These differences increase with the solar zenith angle and are as large as 8%. Larger differences in the instrumental response may be produced by ozone variations. Thus, care must be taken when analyzing data from R-B radiometers and comparing results from different instruments. Routine cycling of UV-B radiometers in operative networks without a careful determination of the spectral responsivity, or small drifts of the spectral responsivity, may strongly affect the accuracy of UV radiation measurements and produce an erroneous trend. Because of the possible differences among radiometers, it would not be practical to derive the long-term behavior of UV radiation without routine and thorough characterization of the spectral responsivities of the instruments.

4.
J Res Natl Inst Stand Technol ; 107(1): 19-62, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-27446717

RESUMO

The fourth North American Intercomparison of Ultraviolet Monitoring Spectroradiometers was held September 15 to 25, 1997 at Table Mountain outside of Boulder, Colorado, USA. Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. The main purpose of the Intercomparison was to assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks. This Intercomparison was coordinated by NIST and NOAA, and included participants from the ASRC, EPA, NIST, NSF, SERC, USDA, and YES. The UV measuring instruments included scanning spectroradiometers, spectrographs, narrow band multi-filter radiometers, and broadband radiometers. Instruments were characterized for wavelength accuracy, bandwidth, stray-light rejection, and spectral irradiance responsivity. The spectral irradiance responsivity was determined two to three times outdoors to assess temporal stability. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST traceable standard lamp, and a simple convolution technique with a Gaussian slit-scattering function to account for the different bandwidths of the instruments, the measured solar irradiance from the spectroradiometers excluding the filter radiometers at 16.5 h UTC had a relative standard deviation of ±4 % for wavelengths greater than 305 nm. The relative standard deviation for the solar irradiance at 16.5 h UTC including the filter radiometer was ±4 % for filter functions above 300 nm.

5.
J Res Natl Inst Stand Technol ; 103(5): 449-482, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-28009358

RESUMO

Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. To assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks, the third North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers was held June 17-25, 1996 at Table Mountain outside Boulder, Colorado, USA. This Intercomparison was coordinated by the National Institute of Standards and Technology (NIST) and the National Oceanic and Atmospheric Administration (NOAA). Participating agencies were the Environmental Protection Agency; the National Science Foundation; the Smithsonian Environmental Research Center; the Department of Agriculture; and the Atmospheric Environment Service, Canada. The spectral irradiances of participants' calibrated standard lamps were measured at NIST prior to the Intercomparison. The spectral irradiance scales used by the participants agreed with the NIST scale within the combined uncertainties, and for all lamps the spectral irradiance in the horizontal position was lower than that in the vertical position. Instruments were characterized for wavelength uncertainty, bandwidth, stray-light rejection, and spectral irradiance responsivity, the latter with NIST standard lamps operating in specially designed field calibration units. The spectral irradiance responsivity demonstrated instabilities for some instruments. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST standard lamps, the measured solar irradiances had some unexplained systematic differences between instruments.

6.
J Res Natl Inst Stand Technol ; 103(1): 15-62, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-28009371

RESUMO

Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. To assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks, the second North American Intercomparison of Ultraviolet Monitoring Spectroradiometers was held June 12 to 23, 1995 at Table Mountain outside Boulder, Colorado, USA. This Intercomparison was coordinated by the National Institute of Standards and Technology (NIST) and the National Oceanic and Atmospheric Administration (NOAA). Participating agencies were the Environmental Protection Agency; the National Science Foundation; the Smithsonian Environmental Research Center; the Department of Agriculture; and the Atmospheric Environment Service, Canada. Instruments were characterized for wavelength uncertainty, bandwidth, stray-light rejection, and spectral irradiance responsivity, the latter with a NIST standard lamp operating in a specially designed field calibration unit. The spectral irradiance responsivity, determined once indoors and twice outdoors, demonstrated that while the responsivities changed upon moving the instruments, they were relatively stable when the instruments remained outdoors. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST standard lamp and three different convolution functions to account for the different bandwidths of the instruments, the measured solar irradiances generally agreed to within 3 %.

7.
J Res Natl Inst Stand Technol ; 102(3): 279-322, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-27805148

RESUMO

Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. To assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks, the first North American Intercomparison of Ultraviolet Monitoring Spectroradiometers was held September 19-29, 1994 at Table Mountain outside Boulder, Colorado, USA. This Intercomparison was coordinated by the National Institute of Standards and Technology and the National Oceanic and Atmospheric Administration (NOAA). Participating agencies were the Environmental Protection Agency, National Science Foundation, Smithsonian Environmental Research Center, and Atmospheric Environment Service, Canada. Instruments were characterized for wavelength accuracy, bandwidth, stray-light rejection, and spectral irradiance responsivity, the latter with a NIST standard lamp calibrated to operate in the horizontal position. The spectral irradiance responsivity was determined once indoors and twice outdoors, and demonstrated that, while the responsivities changed upon moving the instruments, they were relatively stable when the instruments remained outdoors. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST standard lamp, and a simple convolution technique to account for the different bandwidths of the instruments, the measured solar irradiances agreed within 5 %.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...