Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Clin Chem Lab Med ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39016272

RESUMO

The first part of this Inter-Society Document describes the mechanisms involved in the development of cardiovascular diseases, particularly arterial hypertension, in adults and the elderly. It will also examine how consistent physical exercise during adolescence and adulthood can help maintain blood pressure levels and prevent progression to symptomatic heart failure. The discussion will include experimental and clinical evidence on the use of specific exercise programs for preventing and controlling cardiovascular diseases in adults and the elderly. In the second part, the clinical relevance of cardiac-specific biomarkers in assessing cardiovascular risk in the general adult population will be examined, with a focus on individuals engaged in sports activities. This section will review recent studies that suggest a significant role of biomarkers in assessing cardiovascular risk, particularly the presence of cardiac damage, in athletes who participate in high-intensity sports. Finally, the document will discuss the potential of using cardiac-specific biomarkers to monitor the effectiveness of personalized physical activity programs (Adapted Physical Activity, APA). These programs are prescribed for specific situations, such as chronic diseases or physical disabilities, including cardiovascular diseases. The purposes of this Inter-Society Document are the following: 1) to discuss the close pathophysiological relationship between physical activity levels (ranging from sedentary behavior to competitive sports), age categories (from adolescence to elderly age), and the development of cardiovascular diseases; 2) to review in detail the experimental and clinical evidences supporting the role of cardiac biomarkers in identifying athletes and individuals of general population at higher cardiovascular risk; 3) to stimulate scientific societies and organizations to develop specific multicenter studies that may take into account the role of cardiac biomarkers in subjects who follow specific exercise programs in order to monitor their cardiovascular risk.

2.
Ann Clin Biochem ; : 45632241240306, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38497516
3.
Int J Biol Markers ; 38(1): 61-71, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36855811

RESUMO

PURPOSE: The overuse of laboratory tests contributes to impair health systems effectiveness, tumor markers (TMs) being a paradigmatic example. In the present study we applied indicators of TMs appropriateness developed from administrative datasets to appraise regionwide overordering in the clinical practice. PATIENTS AND METHODS: TMs ordered to outpatients in the Veneto Region over 6 years were obtained from the eletronic Outpatients' Records of Diagnostic and Therapeutic Procedures. TMs orders were examined as aggregated data or stratified according to disease codes, gender, age, and requests per patient. TMs recommended only for specific malignancies were examined using epidemiological data obtained from Veneto Tumor Registry. RESULTS: A total of 5,821,251 TMs were ordered in 4,382,159 patients over 6 years. Overall, 3,252,389 (55.9%) TMs were ordered without appropriate disease codes (ranging from 77.0% for PSA to 17.5% for CA15.3). TM orders declined over 6 years (-13.4%), with a noticeable reduction of orders without appropriate disease codes (-21.3%). Orders decreased sharply from 2015 to 2016, after the enactment of a national Decree-Law aimed at improving appropriateness, and remained stable thereafter. However, the rate of inappropriate TMs requests still remained elevated (44.4%) in the last year of observation, with orders of TMs being much higher than expected on the basis of prevalence and incidence figures of specific malignancies. CONCLUSIONS: Indicators developed from administrative datasets were effective in assessing the overordering of TMs and the impact of interventions to improve appropriateness. The developed indicators could be considered for other diagnostic tests.


Assuntos
Biomarcadores Tumorais , Neoplasias , Humanos , Pacientes Ambulatoriais , Neoplasias/epidemiologia , Neoplasias/diagnóstico , Mucina-1 , Sistema de Registros
4.
Clin Chem Lab Med ; 61(7): 1209-1229, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-36695506

RESUMO

In accordance with all the most recent international guidelines, the variation of circulating levels of cardiac troponins I and T, measured with high-sensitivity methods (hs-cTnI and hs-cTnT), should be used for the detection of acute myocardial injury. Recent experimental and clinical evidences have demonstrated that the evaluation of hs-cTnI and hs-cTnT variations is particularly relevant: a) for the differential diagnosis of Acute Coronary Syndromes (ACS) in patients admitted to the Emergency Department (ED); b) for the evaluation of cardiovascular risk in patients undergoing major cardiac or non-cardiac surgery, and in asymptomatic subjects of the general population aged >55 years and with co-morbidities; c) for the evaluation of cardiotoxicity caused by administration of some chemotherapy drugs in patients with malignant tumors. The aim of this document is to discuss the fundamental statistical and biological considerations on the intraindividual variability of hs-cTnI and hs-cTnT over time in the same individual. Firstly, it will be discussed in detail as the variations of circulating levels strictly depend not only on the analytical error of the method used but also on the intra-individual variability of the biomarker. Afterwards, the pathophysiological interpretation and the clinical relevance of the determination of the variability of the hs-cTnI and hs-cTnT values ​​ in patients with specific clinical conditions are discussed. Finally, the evaluation over time of the variation in circulating levels of hs-cTnI and hs-cTnT is proposed for a more accurate estimation of cardiovascular risk in asymptomatic subjects from the general population.


Assuntos
Síndrome Coronariana Aguda , Doenças Cardiovasculares , Humanos , Doenças Cardiovasculares/diagnóstico , Relevância Clínica , Troponina T , Síndrome Coronariana Aguda/diagnóstico , Biomarcadores , Troponina I
5.
Clin Chem Lab Med ; 60(10): 1525-1542, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-35858238

RESUMO

Major adverse cardiovascular events are frequently observed in patients undergoing major non-cardiac surgery during the peri-operative period. At this time, the possibility to predict cardiovascular events remains limited, despite the introduction of several algorithms to calculate the risk of adverse events, mainly death and major adverse cardiovascular events (MACE) based on the clinical history, risk factors (sex, age, lipid profile, serum creatinine) and non-invasive cardiac exams (electrocardiogram, echocardiogram, stress tests). The cardiac-specific biomarkers natriuretic peptides (NPs) and cardiac troponins (cTn) have been proposed as additional tools for risk prediction in the peri-operative period, particularly for the identification of myocardial injury in patients undergoing major non-cardiac surgery. The prognostic information from the measurement of BNP/NT-proBNP and hs-cTn is independent and complementary to other important indicators of risk, also including ECG and imaging techniques. Elevated levels of cardiac-specific biomarkers before surgery are associated with a markedly higher risk of MACE during the peri-operative period. BNP/NT-proBNP and hs-cTn should be measured in all patients during the clinical evaluation before surgery, particularly during intermediate- or high-risk surgery, in patients aged >65 years and/or with comorbidities. Several questions remain to be assessed in dedicated clinical studies, such as how to optimize the management of patients with raised cardiac specific biomarkers before surgery, and whether a strategy based on biomarker measurement improves patient outcomes and is cost-effective.


Assuntos
Doenças Cardiovasculares , Biomarcadores , Fatores de Risco de Doenças Cardíacas , Humanos , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Prognóstico , Medição de Risco , Fatores de Risco
7.
Diagnostics (Basel) ; 12(2)2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35204574

RESUMO

A WHO standard was prepared with the aim of harmonizing assays detecting antibodies against SARS-CoV-2, but the issue is currently being debated. We re-evaluated a previously studied set of cases (108 specimens of 48 patients and 60 specimens of 20 vaccinated subjects, collected after 14 days from the first dose and 14 days and 3 months after a second dose of the Comirnaty BNT162b2 vaccine), calculating the ratios between the results of two methods (SARS-CoV-2 IgG anti-RBD, SNIBE, and anti-SARS-CoV-2 QuantiVac ELISA IgG, Euroimmun). In the vaccinated subjects, the ratios of the results between methods according to the WHO standard were relatively dispersed, but the harmonization results were good. On the other hand, in patient samples, the variability between tests was very high, and the harmonization was unsatisfactory (median ratios between methods 2.23, 10th-90th percentile: 1.1-5.6). Interestingly, in patient samples, the harmonization depends on the time from the onset of symptoms and greatly improves after 6 months since the diagnosis. Forty patient specimens and thirty-one of the vaccinated subjects after the second dose were also evaluated with a third method (Access SARS-CoV-2 IgG (1st IS), Beckman Coulter), obtaining a similar trend. We can conclude that the actual effectiveness of harmonization between methods may vary depending on the scenario in which they will be used.

8.
Clin Chem Lab Med ; 60(2): 169-182, 2022 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-34927403

RESUMO

Serial measurements of cardiac troponin are recommended by international guidelines to diagnose myocardial infarction (MI) since 2000. However, some relevant differences exist between the three different international guidelines published between 2020 and 2021 for the management of patients with chest pain and no ST-segment elevation. In particular, there is no agreement on the cut-offs or absolute change values to diagnose non-ST-segment elevation MI (NSTEMI). Other controversial issues concern the diagnostic accuracy and cost-effectiveness of cut-off values for the most rapid algorithms (0 h/1 h or 0 h/2 h) to rule-in and rule-out NSTEMI. Finally, another important point is the possible differences between demographic and clinical characteristics of patients enrolled in multicenter trials compared to those routinely admitted to the Emergency Department in Italy. The Study Group of Cardiac Biomarkers, supported by the Italian Scientific Societies Società Italiana di Biochimica Clinica, Italian Society of the European Ligand Assay Society, and Società Italiana di Patolgia Clinica e Medicina di Laboratorio decided to revise the document previously published in 2013 about the management of patients with suspected NSTEMI, and to provide some suggestions for the use of these biomarkers in clinical practice, with a particular focus on the Italian setting.


Assuntos
Infarto do Miocárdio , Infarto do Miocárdio sem Supradesnível do Segmento ST , Algoritmos , Biomarcadores , Serviço Hospitalar de Emergência , Humanos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Troponina
9.
Diagnostics (Basel) ; 11(9)2021 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-34574052

RESUMO

The time course of antibodies against SARS-CoV-2 is not yet well elucidated, especially in people who underwent a vaccination campaign. In this study, we measured the antibodies anti-S1 and anti-RBD with two different methods, both in patients and in vaccinated subjects. One hundred and eight specimens from 48 patients with COVID-19 (time from the onset of symptoms from 3 to 368 days) and 60 specimens from 20 vaccinated subjects (collected after 14 days from the first dose, 14 days and 3 months after a second dose of Comirnaty) were evaluated. We used an ELISA method that measured IgG against anti-Spike 1, and a chemiluminescence immunoassay that measured IgG anti-RBD. In the patients, the antibodies concentrations tended to decline after a few months, with both the methods, but they persisted relatively high up to nearly a year after the symptoms. In the vaccinated subjects, the antibodies were already detectable after the first dose, but after the booster, they showed a significant increase. However, the decrease was rapid, given that 3 months after the second vaccination, they were reduced to less than a quarter. The conversion of the results into BAU units improves the relationship between the two methods. However, in the vaccinated subjects, there was no evidence of proportional error after the conversion, while in the patients, the difference between the two methods remained significant.

12.
Diagn Microbiol Infect Dis ; 99(4): 115297, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33388574

RESUMO

INTRODUCTION: The persistence of circulating antibodies to SARS-CoV-2 infection is not yet well known. We compare the results of 2 automated systems for the determination of IgG against SARS CoV-2 and assess the time-course of the IgG response. METHODS: IgG were measured in 103 specimens of 55 patients with COVID-19 (time from the symptoms' onset: 3-187 days) using the automated tests "Abbott SARS-COV-2 IgG" and "MAGLUMI 2019-nCoV IgG". RESULTS: The 2 methods had a concordance of 90.3%, but the quantitative correlation, although significant, showed dispersed results. All the specimens resulted positive after 17 days. However, the median concentrations of IgG rapidly increased up to 20 days and decreased for Maglumi IgG while Abbott IgG showed a constant trend up to 85 days, and then slowly declined. CONCLUSIONS: The titer of IgG against SARS-CoV-2 may significantly and rapidly decrease, but with a very different time-course depending on the method used for the determination.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , Imunoensaio/métodos , Imunoglobulina G/sangue , SARS-CoV-2/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
14.
Clin Chem Lab Med ; 58(10): 1663-1672, 2020 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-31927515

RESUMO

Background The comparability of thyroid-stimulating hormone (TSH) results cannot be easily obtained using SI-traceable reference measurement procedures (RPMs) or reference materials, whilst harmonization is more feasible. The aim of this study was to identify and validate a new approach for the harmonization of TSH results. Methods Percentile normalization was applied to 125,419 TSH results, obtained from seven laboratories using three immunoassays (Access 3rd IS Thyrotropin, Beckman Coulter Diagnostics; Architect System, Abbott Diagnostics and Elecsys, Roche Diagnostics). Recalibration equations (RCAL) were derived by robust regressions using bootstrapped distribution. Two datasets, the first of 119 EQAs, the second of 610, 638 and 639 results from Access, Architect and Elecsys TSH results, respectively, were used to validate RCAL. A dataset of 142,821 TSH values was used to derive reference intervals (RIs) after applying RCAL. Results Access, Abbott and Elecsys TSH distributions were significantly different (p < 0.001). RCAL intercepts and slopes were -0.003 and 0.984 for Access, 0.032 and 1.041 for Architect, -0.031 and 1.003 for Elecsys, respectively. Validation using EQAs showed that before and after RCAL, the coefficients of variation (CVs) or among-assay results decreased from 10.72% to 8.16%. The second validation dataset was used to test RCALs. The median of between-assay differences ranged from -0.0053 to 0.1955 mIU/L of TSH. Elecsys recalibrated to Access (and vice-versa) showed non-significant difference. TSH RI after RCAL resulted in 0.37-5.11 mIU/L overall, 0.49-4.96 mIU/L for females and 0.40-4.92 mIU/L for males. A significant difference across age classes was identified. Conclusions Percentile normalization and robust regression are valuable tools for deriving RCALs and harmonizing TSH values.


Assuntos
Imunoensaio/métodos , Tireotropina/sangue , Calibragem , Sistemas de Informação em Laboratório Clínico , Humanos , Valores de Referência , Reprodutibilidade dos Testes , Tireotropina/normas
16.
Clin Chim Acta ; 496: 25-34, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31201817

RESUMO

BACKGROUND: The study aim is to compare cTnI values measured with three high-sensitivity (hs) methods in apparently healthy volunteers and patients admitted to emergency department (ED) with acute coronary syndrome enrolled in a large multicentre study. METHODS: Heparinized plasma samples were collected from 1511 apparently healthy subjects from 8 Italian clinical institutions (mean age: 51.5 years, SD: 14.1 years, range: 18-65 years, F/M ratio:0.95). All volunteers denied chronic or acute diseases and had normal values of routine laboratory tests. Moreover, 1322 heparinized plasma sample were also collected by 9 Italian clinical institutions from patients admitted to ED with clinical symptoms typical of acute coronary syndrome. The reference study laboratory assayed all plasma samples with three hs-methods: Architect hs-cTnI, Access hs-cTnI and ADVIA Centaur XPT methods. Principal Component Analysis (PCA) was also used to analyze the between-method differences among hs-cTnI assays. RESULTS: On average, a between-method difference of 31.2% CV was found among the results of hs-cTnI immunoassays. ADVIA Centaur XPT method measured higher cTnI values than Architect and Access methods. Moreover, 99th percentile URL values depended not only on age and sex of reference population, but also on the statistical approach used for calculation (robust non-parametric vs bootstrap). CONCLUSIONS: Due to differences in concentrations and reference values, clinicians should be advised that plasma samples of the same patient should be measured for cTnI assay in the same laboratory. Specific clinical studies are needed to establish the most appropriate statistical approach to calculate the 99th percentile URL values for hs-cTnI methods.


Assuntos
Síndrome Coronariana Aguda/sangue , Análise Química do Sangue/métodos , Serviço Hospitalar de Emergência , Voluntários Saudáveis , Limite de Detecção , Miocárdio/metabolismo , Troponina I/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise Química do Sangue/normas , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Admissão do Paciente , Valores de Referência , Adulto Jovem
17.
Clin Chim Acta ; 495: 161-166, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30978328

RESUMO

BACKGROUND: According to quality specifications required by international guidelines, the evaluation of the 99th URL value is a very difficult task that is usually beyond the capacity of a single laboratory. The aims of this article are to report and discuss the results of a multicenter study concerning the evaluation of the 99th percentile URL and reference change (RCV) of the ADVIA Centaur High-Sensitivity Troponin I (TNIH), recently distributed to the Italian clinical laboratories. MATERIALS AND METHODS: The reference population evaluated with ADVIA XPT method for the calculation of cTnI reference distribution parameters consisted of 1325 healthy adults subjects (age range from 18 to 86 years), including 653 women (mean age 50.7 years, SD 14.5 years) and 672 men (mean age 50.9 years, SD 13.8 years), well matched for both age (P = .8112) and sex (F/M = 0.97). RESULTS: cTnI distribution values of reference population was highly skewed, while log-transformed cTnI values roughly approximated a log-normal distribution. Men have higher cTnI values than women throughout all the adult lifespan. Moreover, the subjects with age ≤ 55 years had significantly lower cTnI values than those with age > 55 years (p < .0001). Of note, 62% of women and 77% of men had equal or higher than cTnI values than the LoD value of the method (i.e., 2.2 ng/L). CONCLUSIONS: The results of the present study demonstrate that the ADVIA Centaur High-Sensitivity Troponin I using the XPT automated platform fits both the criteria and quality specifications required by the most recent international guidelines for high-sensitivity methods for cTnI assay.


Assuntos
Análise Química do Sangue/normas , Miocárdio/metabolismo , Troponina I/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imunoensaio/normas , Masculino , Pessoa de Meia-Idade , Valores de Referência , Troponina I/metabolismo , Adulto Jovem
18.
Scand J Clin Lab Invest ; 79(4): 260-267, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30982358

RESUMO

The aim of the present study was to investigate serum HER2 extracellular domain (ECD) as a putative surrogate marker of the shedding phenomenon of HER2 receptor from the tumor tissue of primary breast cancer (BC) patients. A pilot retrospective study was conducted on 100 matched serum and tissue samples from patients with node-positive primary BC, stage II/III. Analysis of association and concordance between serum HER2 ECD levels (measured by chemiluminescence immunoassay) and the expression in matched tumor tissue of HER2 ECD and intracellular receptor domain (ICD) (determined by immunohistochemistry) were performed. The median serum HER2 ECD level was 9.4 ng/ml and cutoff values were set at 15.2 ng/ml or 13.0 ng/ml. HER2 ICD and ECD were overexpressed in tumor tissue of 19.8% and 6.9% of patients, respectively. Statistically significant associations were found between serum HER2 ECD levels and tissue expression of both HER2 ICD and ECD (p < .001; Fisher analysis). Moreover, strong concordances were found between serum HER2 ECD levels and tissue expression of HER2 ICD or ECD (cutoff 15.2 ng/ml: 80 and 92.5%, respectively). Our findings support a role for serum HER2 ECD as a surrogate marker of tissue HER2 status in primary BC, both for HER2 ICD or ECD expression.


Assuntos
Neoplasias da Mama/metabolismo , Espaço Extracelular/metabolismo , Receptor ErbB-2/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/sangue , Neoplasias da Mama/cirurgia , Feminino , Humanos , Espaço Intracelular , Pessoa de Meia-Idade , Domínios Proteicos , Receptor ErbB-2/sangue , Receptor ErbB-2/química
20.
Clin Chim Acta ; 493: 156-161, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30826369

RESUMO

BACKGROUND: The Italian Society of Clinical Biochemistry (SIBioC) and the Italian Section of the European Ligand Assay Society (ELAS) have recently promoted a multicenter study (Italian hs-cTnI Study) with the aim to accurately evaluate analytical performances and reference values of the most popular cTnI methods commercially available in Italy. The aim of this article is to report the results of the Italian hs-cTnI Study concerning the evaluation of the 99th percentile URL and reference change (RCV) values around the 99th URL of the Access cTnI method. MATERIALS AND METHODS: Heparinized plasma samples were collected from 1306 healthy adult volunteers by 8 Italian clinical centers. Every center collected from 50 to 150 plasma samples from healthy adult subjects. All volunteers denied the presence of chronic or acute diseases and had normal values of routine laboratory tests (including creatinine, electrolytes, glucose and blood counts). An older cohort of 457 adult subjects (mean age 63.0 years; SD 8.1 years, minimum 47 years, maximum 86 years) underwent also ECG and cardiac imaging analysis in order to exclude the presence of asymptomatic cardiac disease. RESULTS AND CONCLUSIONS: The results of the present study confirm that the Access hsTnI method using the DxI platform satisfies the two criteria required by international guidelines for high-sensitivity methods for cTn assay. Furthermore, the results of this study confirm that the calculation of the 99th percentile URL values are greatly affected not only by age and sex of the reference population, but also by the statistical approach used for calculation of cTnI distribution parameters.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/normas , Eletrocardiografia/normas , Troponina I/sangue , Troponina T/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Voluntários Saudáveis , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...