Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 155: 108924, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31600632

RESUMO

In this study, we modeled the effects of flaws in a solid material as three different slit types (rectangular, rectilinear, and semicircular) and their orientations in a duralumin (aluminum alloy) plate in simulations based on 137Cs gamma backscattering. The simulations were performed using the Monte Carlo GEANT4 simulation toolkit. The simulation results showed that the shape of the slit had a small effect on the backscattering peak curve. Rotating the slit on the Y-axis and Z-axis of the duralumin plate influenced the 137Cs backscattering peak height in the energy range from 0.185 to 0.20 MeV, where the backscattering peak areas exhibited specific patterns due to the slit orientations.

2.
Phys Rev Lett ; 123(3): 031302, 2019 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-31386435

RESUMO

We present new constraints on the dark matter-induced annual modulation signal using 1.7 years of COSINE-100 data with a total exposure of 97.7 kg yr. The COSINE-100 experiment, consisting of 106 kg of NaI(Tl) target material, is designed to carry out a model-independent test of DAMA/LIBRA's claim of WIMP discovery by searching for the same annual modulation signal using the same NaI(Tl) target. The crystal data show a 2.7 cpd/kg/keV background rate on average in the 2-6 keV energy region of interest. Using a χ-squared minimization method we observe best fit values for modulation amplitude and phase of 0.0092±0.0067 cpd/kg/keV and 127.2±45.9 d, respectively.

3.
Phys Rev Lett ; 122(13): 131802, 2019 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-31012610

RESUMO

A search for inelastic boosted dark matter (IBDM) using the COSINE-100 detector with 59.5 days of data is presented. This relativistic dark matter is theorized to interact with the target material through inelastic scattering with electrons, creating a heavier state that subsequently produces standard model particles, such as an electron-positron pair. In this study, we search for this electron-positron pair in coincidence with the initially scattered electron as a signature for an IBDM interaction. No excess over the predicted background event rate is observed. Therefore, we present limits on IBDM interactions under various hypotheses, one of which allows us to explore an area of the dark photon parameter space that has not yet been covered by other experiments. This is the first experimental search for IBDM using a terrestrial detector.

4.
Eur Phys J C Part Fields ; 78(6): 490, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30956554

RESUMO

The COSINE-100 dark matter search experiment is an array of NaI(Tl) crystal detectors located in the Yangyang Underground Laboratory (Y2L). To understand measured backgrounds in the NaI(Tl) crystals we have performed Monte Carlo simulations using the Geant4 toolkit and developed background models for each crystal that consider contributions from both internal and external sources, including cosmogenic nuclides. The background models are based on comparisons of measurement data with Monte Carlo simulations that are guided by a campaign of material assays and are used to evaluate backgrounds and identify their sources. The average background level for the six crystals (70 kg total mass) that are studied is 3.5 counts/day/keV/kg in the (2-6) keV energy interval. The dominant contributors in this energy region are found to be 210 Pb and 3 H.

5.
Rev Sci Instrum ; 84(7): 075116, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23902115

RESUMO

A high-speed impact testing method for evaluating mechanical properties of materials is proposed using an inertial mass and a dual beat-frequencies laser Doppler interferometer (DB-LDI). In this method, an inertial mass levitated using an aerostatic linear bearing is made to collide with the material being tested at a high initial velocity. During the collision, the velocity of the mass, which is even higher than the critical velocity (±0.56 m/s) defined by the frequency difference of the Zeeman laser, is accurately measured using the DB-LDI. The position, acceleration, and impact force of the mass are calculated from the measured velocity. Using the proposed method, the mechanical properties of a visco-elastic material under a high-speed impact loading condition can be accurately evaluated.

6.
Saudi Med J ; 25(7): 955-7, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15235708

RESUMO

Posterior mediastinal enteric cysts are infrequently reported. They are mostly asymptomatic 1. The incidence of gastroenteric cysts presenting during immediate neonatal period is rare. Alimentary tract duplications are other rare congenital anomalies and are commonly seen in relation to the ileum. However, the high incidence of associated thoracic or cervical vertebral anomalies with foregut cysts provide an early clue to the diagnosis 2. A detailed timely antenatal scan can increase the awareness regarding such rare condition and help in diagnosis and better outcome. The purpose of this case report is to highlight the clinical diagnosis and management of a neonate with posterior mediastinal gastroenteric cyst.


Assuntos
Coristoma/diagnóstico , Mucosa Gástrica , Cisto Mediastínico/congênito , Coristoma/patologia , Coristoma/cirurgia , Diagnóstico Diferencial , Diagnóstico por Imagem , Humanos , Recém-Nascido , Masculino , Cisto Mediastínico/diagnóstico , Cisto Mediastínico/patologia , Mediastino/patologia , Mediastino/cirurgia , Síndrome do Desconforto Respiratório do Recém-Nascido/etiologia , Toracotomia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...