Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 60(2)2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38399551

RESUMO

Background and Objectives: Atrial fibrillation (AF), a prevalent cardiac arrhythmia, significantly impacts the quality of life of those affected. The preferred treatment for symptomatic AF, particularly when pharmacological methods fall short, is catheter ablation with pulmonary vein isolation (PVI). While common pulmonary vein (PV) anatomical variants, such as the right accessory pulmonary vein and the common ostium of left pulmonary veins (LCPV), have been studied extensively, their impact on the long-term outcome of PVI is known to be minimal. However, data on less common anomalies, like the common ostium of the left and right inferior pulmonary vein (CIPV), remain scarce in the medical literature. This report aims to shed light on the challenges and outcomes of catheter ablation in a patient with a rare CIPV anomaly. By presenting this case, we contribute to the limited knowledge about the management of such unique anatomical variations in AF treatment and discuss the importance of individualized treatment approaches. Case Presentation: We present a case involving a 56-year-old male diagnosed with AF in 2018. Initial PVI treatment was successful, but the patient experienced symptom recurrence after three years. A preprocedural CT scan before the second ablation revealed a CIPV anomaly. During the repeat procedure, a right superior pulmonary vein (RSPV) reisolation was performed due to identified gaps in the previous ablation line. Post-procedure, the patient maintained a sinus rhythm and reported no further symptoms. Conclusions: This case highlights the importance of recognizing rare PV anatomies like CIPV in the effective management of AF. Tailored ablation strategies, accounting for unique anatomical conditions, can lead to successful long-term outcomes, reinforcing the need for personalized approaches in AF treatment, especially in cases involving complex anatomical variations.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Masculino , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Qualidade de Vida , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
2.
Ann Noninvasive Electrocardiol ; 27(5): e12952, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35467789

RESUMO

We present a case report of a 74-year-old male patient with an implantable cardioverter defibrillator who suffered an inappropriate defibrillation shock while bathing in the tub. Insight in the ICD stored electrogram episodes revealed electromagnetic interferences, with a typical 50 Hz electrical artifact mimicking fast ventricular tachycardia as a device misinterpreted. After this event, the maintenance workers investigated the electrical installation in the bathroom and revealed that there was voltage leaking between electrical installation and metal pipes. After the repair was completed without any additional programming, the patient has had no subsequent shocks.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Idoso , Arritmias Cardíacas , Eletrocardiografia , Fenômenos Eletromagnéticos , Humanos , Masculino , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...