Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
Sci Rep ; 14(1): 9563, 2024 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671043

RESUMO

Extracting longitudinal image quantitative data, known as delta-radiomics, has the potential to capture changes in a patient's anatomy throughout the course of radiation treatment for prostate cancer. Some of the major challenges of delta-radiomics studies are contouring the structures for individual fractions and accruing patients' data in an efficient manner. The manual contouring process is often time consuming and would limit the efficiency of accruing larger sample sizes for future studies. The problem is amplified because the contours are often made by highly trained radiation oncologists with limited time to dedicate to research studies of this nature. This work compares the use of automated prostate contours generated using a deformable image-based algorithm to make predictive models of genitourinary and changes in total international prostate symptom score in comparison to manually contours for a cohort of fifty patients. Area under the curve of manual and automated models were compared using the Delong test. This study demonstrated that the delta-radiomics models were similar for both automated and manual delta-radiomics models.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Algoritmos , Idoso , Pessoa de Meia-Idade , Lesões por Radiação/etiologia , Radiômica
2.
Radiat Oncol ; 19(1): 13, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38263237

RESUMO

BACKGROUND: To assess the feasibility of CBCT-based adaptive intensity modulated proton therapy (IMPT) using automated planning for treatment of head and neck (HN) cancers. METHODS: Twenty HN cancer patients who received radiotherapy and had pretreatment CBCTs were included in this study. Initial IMPT plans were created using automated planning software for all patients. Synthetic CTs (sCT) were then created by deforming the planning CT (pCT) to the pretreatment CBCTs. To assess dose calculation accuracy on sCTs, repeat CTs (rCTs) were deformed to the pretreatment CBCT obtained on the same day to create deformed rCT (rCTdef), serving as gold standard. The dose recalculated on sCT and on rCTdef were compared by using Gamma analysis. The accuracy of DIR generated contours was also assessed. To explore the potential benefits of adaptive IMPT, two sets of plans were created for each patient, a non-adapted IMPT plan and an adapted IMPT plan calculated on weekly sCT images. The weekly doses for non-adaptive and adaptive IMPT plans were accumulated on the pCT, and the accumulated dosimetric parameters of two sets were compared. RESULTS: Gamma analysis of the dose recalculated on sCT and rCTdef resulted in a passing rate of 97.9% ± 1.7% using 3 mm/3% criteria. With the physician-corrected contours on the sCT, the dose deviation range of using sCT to estimate mean dose for the most organ at risk (OARs) can be reduced to (- 2.37%, 2.19%) as compared to rCTdef, while for V95 of primary or secondary CTVs, the deviation can be controlled within (- 1.09%, 0.29%). Comparison of the accumulated doses from the adaptive planning against the non-adaptive plans reduced mean dose to constrictors (- 1.42 Gy ± 2.79 Gy) and larynx (- 2.58 Gy ± 3.09 Gy). The reductions result in statistically significant reductions in the normal tissue complication probability (NTCP) of larynx edema by 7.52% ± 13.59%. 4.5% of primary CTVs, 4.1% of secondary CTVs, and 26.8% tertiary CTVs didn't meet the V95 > 95% constraint on non-adapted IMPT plans. All adaptive plans were able to meet the coverage constraint. CONCLUSION: sCTs can be a useful tool for accurate proton dose calculation. Adaptive IMPT resulted in better CTV coverage, OAR sparing and lower NTCP for some OARs as compared with non-adaptive IMPT.


Assuntos
Transtornos da Coagulação Sanguínea , Neoplasias de Cabeça e Pescoço , Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Prótons , Tomografia Computadorizada de Feixe Cônico
3.
J Appl Clin Med Phys ; 25(2): e14168, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37798910

RESUMO

PURPOSE: Knowledge-based planning (KBP) aims to automate and standardize treatment planning. New KBP users are faced with many questions: How much does model size matter, and are multiple models needed to accommodate specific physician preferences? In this study, six head-and-neck KBP models were trained to address these questions. METHODS: The six models differed in training size and plan composition: The KBPFull (n = 203 plans), KBP101 (n = 101), KBP50 (n = 50), and KBP25 (n = 25) were trained with plans from two head-and-neck physicians. KBPA and KBPB each contained n = 101 plans from only one physician, respectively. An independent set of 39 patients treated to 6000-7000 cGy by a third physician was re-planned with all KBP models for validation. Standard head-and-neck dosimetric parameters were used to compare resulting plans. KBPFull plans were compared to the clinical plans to evaluate overall model quality. Additionally, clinical and KBPFull plans were presented to another physician for blind review. Dosimetric comparison of KBPFull against KBP101 , KBP50 , and KBP25 investigated the effect of model size. Finally, KBPA versus KBPB tested whether training KBP models on plans from one physician only influences the resulting output. Dosimetric differences were tested for significance using a paired t-test (p < 0.05). RESULTS: Compared to manual plans, KBPFull significantly increased PTV Low D95% and left parotid mean dose but decreased dose cochlea, constrictors, and larynx. The physician preferred the KBPFull plan over the manual plan in 20/39 cases. Dosimetric differences between KBPFull , KBP101 , KBP50 , and KBP25 plans did not exceed 187 cGy on aggregate, except for the cochlea. Further, average differences between KBPA and KBPB were below 110 cGy. CONCLUSIONS: Overall, all models were shown to produce high-quality plans. Differences between model outputs were small compared to the prescription. This indicates only small improvements when increasing model size and minimal influence of the physician when choosing treatment plans for training head-and-neck KBP models.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Bases de Conhecimento , Radiometria , Órgãos em Risco
4.
Med Phys ; 50(8): e865-e903, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37384416

RESUMO

PURPOSE: Electronic portal imaging devices (EPIDs) have been widely utilized for patient-specific quality assurance (PSQA) and their use for transit dosimetry applications is emerging. Yet there are no specific guidelines on the potential uses, limitations, and correct utilization of EPIDs for these purposes. The American Association of Physicists in Medicine (AAPM) Task Group 307 (TG-307) provides a comprehensive review of the physics, modeling, algorithms and clinical experience with EPID-based pre-treatment and transit dosimetry techniques. This review also includes the limitations and challenges in the clinical implementation of EPIDs, including recommendations for commissioning, calibration and validation, routine QA, tolerance levels for gamma analysis and risk-based analysis. METHODS: Characteristics of the currently available EPID systems and EPID-based PSQA techniques are reviewed. The details of the physics, modeling, and algorithms for both pre-treatment and transit dosimetry methods are discussed, including clinical experience with different EPID dosimetry systems. Commissioning, calibration, and validation, tolerance levels and recommended tests, are reviewed, and analyzed. Risk-based analysis for EPID dosimetry is also addressed. RESULTS: Clinical experience, commissioning methods and tolerances for EPID-based PSQA system are described for pre-treatment and transit dosimetry applications. The sensitivity, specificity, and clinical results for EPID dosimetry techniques are presented as well as examples of patient-related and machine-related error detection by these dosimetry solutions. Limitations and challenges in clinical implementation of EPIDs for dosimetric purposes are discussed and acceptance and rejection criteria are outlined. Potential causes of and evaluations of pre-treatment and transit dosimetry failures are discussed. Guidelines and recommendations developed in this report are based on the extensive published data on EPID QA along with the clinical experience of the TG-307 members. CONCLUSION: TG-307 focused on the commercially available EPID-based dosimetric tools and provides guidance for medical physicists in the clinical implementation of EPID-based patient-specific pre-treatment and transit dosimetry QA solutions including intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) treatments.

5.
Front Oncol ; 13: 1130155, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36998445

RESUMO

Using active tumor-targeting nanoparticles, fluorescence imaging can provide highly sensitive and specific tumor detection, and precisely guide radiation in translational radiotherapy study. However, the inevitable presence of non-specific nanoparticle uptake throughout the body can result in high levels of heterogeneous background fluorescence, which limits the detection sensitivity of fluorescence imaging and further complicates the early detection of small cancers. In this study, background fluorescence emanating from the baseline fluorophores was estimated from the distribution of excitation light transmitting through tissues, by using linear mean square error estimation. An adaptive masked-based background subtraction strategy was then implemented to selectively refine the background fluorescence subtraction. First, an in vivo experiment was performed on a mouse intratumorally injected with passively targeted fluorescent nanoparticles, to validate the reliability and robustness of the proposed method in a stringent situation wherein the target fluorescence was overlapped with the strong background. Then, we conducted in vivo studies on 10 mice which were inoculated with orthotopic breast tumors and intravenously injected with actively targeted fluorescent nanoparticles. Results demonstrated that active targeting combined with the proposed background subtraction method synergistically increased the accuracy of fluorescence molecular imaging, affording sensitive tumor detection.

6.
Nanomaterials (Basel) ; 12(24)2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36558293

RESUMO

Metal nanoparticles are effective radiosensitizers that locally enhance radiation doses in targeted cancer cells. Compared with other metal nanoparticles, gold nanoparticles (GNPs) exhibit high biocompatibility, low toxicity, and they increase secondary electron scatter. Herein, we investigated the effects of active-targeting GNPs on the radiation-induced bystander effect (RIBE) in prostate cancer cells. The impact of GNPs on the RIBE presents implications for secondary cancers or spatially fractionated radiotherapy treatments. Anti-prostate-specific membrane antigen (PSMA) antibodies were conjugated with PEGylated GNPs through EDC-NHS chemistry. The media transfer technique was performed to induce the RIBE on the non-irradiated bystander cells. This study focused on the LNCaP cell line, because it can model a wide range of stages relating to prostate cancer progression, including the transition from androgen dependence to castration resistance and bone metastasis. First, LNCaP cells were pretreated with phosphate buffered saline (PBS) or PSMA-targeted GNPs (PGNPs) for 24 h and irradiated with 160 kVp X-rays (0-8 Gy). Following that, the collected culture media were filtered (sterile 0.45 µm polyethersulfone) in order to acquire PBS- and PGNP- conditioned media (CM). Then, PBS- and PGNP-CM were transferred to the bystander cells that were loaded with/without PGNPs. MTT, γ-H2AX, clonogenic assays and reactive oxygen species assessments were performed to compare RIBE responses under different treatments. Compared with 2 Gy-PBS-CM, 8 Gy-PBS-CM demonstrated a much higher RIBE response, thus validating the dose dependence of RIBE in LNCaP cells. Compared with PBS-CM, PGNP-CM exhibited lower cell viability, higher DNA damage, and a smaller survival fraction. In the presence of PBS-CM, bystander cells loaded with PGNPs showed increased cell death compared with cells that did not have PGNPs. These results demonstrate the PGNP-boosted expression and sensitivity of RIBE in prostate cancer cells.

7.
Sci Rep ; 12(1): 18631, 2022 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-36329116

RESUMO

Real-time magnetic resonance image guided stereotactic ablative radiotherapy (MRgSBRT) is used to treat abdominal tumors. Longitudinal data is generated from daily setup images. Our study aimed to identify delta radiomic texture features extracted from these images to predict for local control in patients with liver tumors treated with MRgSBRT. Retrospective analysis of an IRB-approved database identified patients treated with MRgSBRT for primary liver and secondary metastasis histologies. Daily low field strength (0.35 T) images were retrieved, and the gross tumor volume was identified on each image. Next, images' gray levels were equalized, and 39 s-order texture features were extracted. Delta-radiomics were calculated as the difference between feature values on the initial scan and after delivered biological effective doses (BED, α/ß = 10) of 20 Gy and 40 Gy. Then, features were ranked by the Gini Index during training of a random forest model. Finally, the area under the receiver operating characteristic curve (AUC) was estimated using a bootstrapped logistic regression with the top two features. We identified 22 patients for analysis. The median dose delivered was 50 Gy in 5 fractions. The top two features identified after delivery of BED 20 Gy were gray level co-occurrence matrix features energy and gray level size zone matrix based large zone emphasis. The model generated an AUC = 0.9011 (0.752-1.0) during bootstrapped logistic regression. The same two features were selected after delivery of a BED 40 Gy, with an AUC = 0.716 (0.600-0.786). Delta-radiomic features after a single fraction of SBRT predicted local control in this exploratory cohort. If confirmed in larger studies, these features may identify patients with radioresistant disease and provide an opportunity for physicians to alter management much sooner than standard restaging after 3 months. Expansion of the patient database is warranted for further analysis of delta-radiomic features.


Assuntos
Neoplasias Hepáticas , Radiocirurgia , Humanos , Radiocirurgia/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Curva ROC , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/etiologia
8.
Sci Rep ; 12(1): 20136, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-36418901

RESUMO

For prostate cancer (PCa) patients treated with definitive radiotherapy (RT), acute and late RT-related genitourinary (GU) toxicities adversely impact disease-specific quality of life. Early warning of potential RT toxicities can prompt interventions that may prevent or mitigate future adverse events. During intensity modulated RT (IMRT) of PCa, daily cone-beam computed tomography (CBCT) images are used to improve treatment accuracy through image guidance. This work investigated the performance of CBCT-based delta-radiomic features (DRF) models to predict acute and sub-acute International Prostate Symptom Scores (IPSS) and Common Terminology Criteria for Adverse Events (CTCAE) version 5 GU toxicity grades for 50 PCa patients treated with definitive RT. Delta-radiomics models were built using logistic regression, random forest for feature selection, and a 1000 iteration bootstrapping leave one analysis for cross validation. To our knowledge, no prior studies of PCa have used DRF models based on daily CBCT images. AUC of 0.83 for IPSS and greater than 0.7 for CTCAE grades were achieved as early as week 1 of treatment. DRF extracted from CBCT images showed promise for the development of models predictive of RT outcomes. Future studies will include using artificial intelligence and machine learning to expand CBCT sample sizes available for radiomics analysis.


Assuntos
Neoplasias da Próstata , Doenças Urogenitais , Masculino , Humanos , Próstata/diagnóstico por imagem , Projetos Piloto , Qualidade de Vida , Inteligência Artificial , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Tomografia Computadorizada de Feixe Cônico
9.
Phys Med ; 103: 26-36, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36219960

RESUMO

PURPOSE: To develop a new registration quality metric, based on the distance between image edges, for automated evaluation and comparison of DIR algorithms. METHODS: Canny filter is used to create binary gradient images from input images to be compared. A small subregion of one binary image is translated relative to the other. The translational distance maximizing overlap of edges in the subregion is the local edge gradient distance to agreement (EGDTA); repeating over all subregions provides an EGDTA map. The method was tested on phantom and pelvic CT images, by applying a known deformable vector field (DVF). The method was then applied to evaluate two DIR algorithms (SICLE and Demons) for pelvic CTs from five patients. Three SICLE variants were used: Grayscale-driven (G), Contour-driven (C), and Grayscale + Contour-driven (G + C). For each patient, a planning CT was registered to three repeat CTs using the above DIR algorithms. Mean EGDTA values in concentric ring regions of interest close to and far away from the pelvic organ contours were compared. RESULTS: EGDTA maps and imposed DVF deformations on phantom and CT images demonstrated agreement. In comparison of the three variants of SICLE: C had lower EGDTA values close to the pelvic organs, while G showed much better performance in the regions distant from the organs compared to C; and G + C registration exhibited the lowest or comparable EGDTA value among three variants. Demons achieved the lowest EGDTA values. CONCLUSIONS: The EGDTA metric shows potential as an automated means of evaluating and comparing DIR algorithms.


Assuntos
Processamento de Imagem Assistida por Computador , Planejamento da Radioterapia Assistida por Computador , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Algoritmos
10.
Pharmaceutics ; 14(10)2022 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-36297640

RESUMO

Active targeting gold nanoparticles (AuNPs) are a very promising avenue for cancer treatment with many publications on AuNP mediated radiosensitization at kilovoltage (kV) photon energies. However, uncertainty on the effectiveness of AuNPs under clinically relevant megavoltage (MV) radiation energies hinders the clinical translation of AuNP-assisted radiation therapy (RT) paradigm. The aim of this study was to investigate radiosensitization mediated by PSMA-targeted AuNPs irradiated by a 6 MV radiation beam at different depths to explore feasibility of AuNP-assisted prostate cancer RT under clinically relevant conditions. PSMA-targeted AuNPs (PSMA-AuNPs) were synthesized by conjugating PSMA antibodies onto PEGylated AuNPs through EDC/NHS chemistry. Confocal fluorescence microscopy was used to verify the active targeting of the developed PSMA-AuNPs. Transmission electron microscopy (TEM) was used to demonstrate the intracellular biodistribution of PSMA-AuNPs. LNCaP prostate cancer cells treated with PSMA-AuNPs were irradiated on a Varian 6 MV LINAC under varying depths (2.5 cm, 10 cm, 20 cm, 30 cm) of solid water. Clonogenic assays were carried out to determine the in vitro cell survival fractions. A Monte Carlo (MC) model developed on TOPAS platform was then employed to determine the nano-scale radial dose distribution around AuNPs, which was subsequently used to predict the radiation dose response of LNCaP cells treated with AuNPs. Two different cell models, with AuNPs located within the whole cell or only in the cytoplasm, were used to assess how the intracellular PSMA-AuNP biodistribution impacts the prostate cancer radiosensitization. Then, MC-based microdosimetry was combined with the local effect model (LEM) to calculate cell survival fraction, which was benchmarked against the in vitro clonogenic assays at different depths. In vitro clonogenic assay of LNCaP cells demonstrated the depth dependence of AuNP radiosensitization under clinical megavoltage beams, with sensitization enhancement ratio (SER) of 1.14 ± 0.03 and 1.55 ± 0.05 at 2.5 cm depth and 30 cm depth, respectively. The MC microdosimetry model showed the elevated percent of low-energy photons in the MV beams at greater depth, consequently resulting in increased dose enhancement ratio (DER) of AuNPs with depth. The AuNP-induced DER reached ~5.7 and ~8.1 at depths of 2.5 cm and 30 cm, respectively. Microdosimetry based LEM accurately predicted the cell survival under 6 MV beams at different depths, for the cell model with AuNPs placed only in the cell cytoplasm. TEM results demonstrated the distribution of PSMA-AuNPs in the cytoplasm, confirming the accuracy of MC microdosimetry based LEM with modelled AuNPs distributed within the cytoplasm. We conclude that AuNP radiosensitization can be achieved under megavoltage clinical radiotherapy energies with a dependence on tumor depth. Furthermore, the combination of Monte Carlo microdosimetry and LEM will be a valuable tool to assist with developing AuNP-aided radiotherapy paradigm and drive clinical translation.

11.
Radiat Oncol ; 17(1): 162, 2022 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-36175971

RESUMO

BACKGROUND: To assess the impact of systematic setup and range uncertainties for robustly optimized (RO) intensity modulated proton therapy (IMPT) and volumetric modulated arc therapy (VMAT) plans in patients with localized prostate cancer. METHODS: Twenty-six localized prostate patients previously treated with VMAT (CTV to PTV expansion of 3-5 mm) were re-planned with RO-IMPT with 3 mm and 5 mm geometrical uncertainties coupled with 3% range uncertainties. Robust evaluations (RE) accounting for the geometrical uncertainties of 3 and 5 mm were evaluated for the IMPT and VMAT plans. Clinical target volume (CTV), anorectum, and bladder dose metrics were analyzed between the nominal plans and their uncertainty perturbations. RESULTS: With geometric uncertainties of 5 mm and accounting for potential inter-fractional perturbations, RO-IMPT provided statistically significant (p < 0.05) sparing at intermediate doses (V4000cGy) to the anorectum and bladder and high dose sparring (V8000cGy) to the bladder compared to VMAT. Decreasing the RO and RE parameters to 3 mm improved IMPT sparing over VMAT at all OAR dose levels investigated while maintaining equivalent coverage to the CTV. CONCLUSIONS: For localized prostate treatments, if geometric uncertainties can be maintained at or below 3 mm, RO-IMPT provides clear dosimetric advantages in anorectum and bladder sparing compared to VMAT. This advantage remains even under uncertainty scenarios. As geometric uncertainties increase to 5 mm, RO-IMPT still provides dosimetric advantages, but to a smaller magnitude.


Assuntos
Neoplasias da Próstata , Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Masculino , Órgãos em Risco , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos , Incerteza
12.
Front Oncol ; 12: 807725, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35515129

RESUMO

Purpose: The purpose of this work is to explore delta-radiomics texture features for predicting response using setup images of pancreatic cancer patients treated with magnetic resonance image guided (MRI-guided) stereotactic ablative radiotherapy (SBRT). Methods: The total biological effective dose (BED) was calculated for 30 patients treated with MRI-guided SBRT that delivered physical doses of 30-60 Gy in three to five fractions. Texture features were then binned into groups based upon BED per fraction by dividing BED by the number of fractions. Delta-radiomics texture features were calculated after delivery of 20 Gy BED (BED20 features) and 40 Gy BED (BED40 features). A random forest (RF) model was constructed using BED20 and then BED40 features to predict binary outcome. During model training, the Gini Index, a measure of a variable's importance for accurate prediction, was calculated for all features, and the two features that ranked the highest were selected for internal validation. The two features selected from each bin were used in a bootstrapped logistic regression model to predict response and performance quantified using the area under the receiver operating characteristic curve (AUC). This process was an internal validation analysis. Results: After RF model training, the Gini Index was highest for gray-level co-occurrence matrix-based (GLCM) sum average, and neighborhood gray tone difference matrix-based (NGTDM) busyness for BED20 features and gray-level size zone matrix-based (GLSZM) large zones low gray-level emphasis and gray-level run length matrix-based (GLRLM) run percentage was selected from the BED40-based features. The mean AUC obtained using the two BED20 features was AUC = 0.845 with the 2.5 percentile and 97.5 percentile values ranging from 0.794 to 0.856. Internal validation of the BED40 delta-radiomics features resulted in a mean AUC = 0.567 with a 2.5 and 97.5 percentile range of 0.502-0.675. Conclusion: Early changes in treatment quantified with the BED20 delta-radiomics texture features in low field images acquired during MRI-guided SBRT demonstrated better performance in internal validation than features calculated later in treatment. Further analysis of delta-radiomics texture analysis in low field MRI is warranted.

13.
Phys Med ; 92: 69-74, 2021 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-34871889

RESUMO

PURPOSE/OBJECTIVE: To evaluate intra-fraction target shift during automated mono-isocentric linac-based stereotactic radiosurgery with open-face mask system and optical real-time tracking. MATERIALS/METHODS: Ninety-five patients were treated using automated linac-based stereotactic radiosurgery in 1-5 fractions with single isocenter for a total of 195 fractions. During treatment, patient positioning was tracked real-time with optical surface guidance and immobilized with a rigid open-face mask. Patients were re-positioned if optical surface guidance error exceeded 1 mm magnitude or 1°. Translational and rotational intra-fractional changes were determined by post-treatment CBCT matched to the planning CT. Target specific error was calculated by translation and rotation matrices applied to isocenter and target spatial coordinates. RESULTS: For 132 fractions with isocenter within a single target, the median shift magnitude was 0.40 mm with a maximum shift of 1.17 mm. A total of 398 targets treated for plans having multiple or single targets that lied outside isocenter, resulted in a median shift magnitude of 0.46 mm, with median translational shifts of 0.20 mm and 0.20° rotational shifts. A 1 mm PTV margin was insufficient in 18% of targets at a distance greater than 6 cm away from isocenter, but sufficient for 96% of targets within 6 cm. CONCLUSIONS: The findings of this study support 1 mm PTV expansion due to intra-fraction motion to ensure target coverage for plans with isocenter placement less than 6 cm away from the targets.

14.
Front Oncol ; 11: 737901, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34737954

RESUMO

PURPOSE: To assess the performance of a proton-specific knowledge-based planning (KBP) model in the creation of robustly optimized intensity-modulated proton therapy (IMPT) plans for treatment of advanced head and neck (HN) cancer patients. METHODS: Seventy-three patients diagnosed with advanced HN cancer previously treated with volumetric modulated arc therapy (VMAT) were selected and replanned with robustly optimized IMPT. A proton-specific KBP model, RapidPlanPT (RPP), was generated using 53 patients (20 unilateral cases and 33 bilateral cases). The remaining 20 patients (10 unilateral and 10 bilateral cases) were used for model validation. The model was validated by comparing the target coverage and organ at risk (OAR) sparing in the RPP-generated IMPT plans with those in the expert plans. To account for the robustness of the plan, all uncertainty scenarios were included in the analysis. RESULTS: All the RPP plans generated were clinically acceptable. For unilateral cases, RPP plans had higher CTV_primary V100 (1.59% ± 1.24%) but higher homogeneity index (HI) (0.7 ± 0.73) than had the expert plans. In addition, the RPP plans had better ipsilateral cochlea Dmean (-5.76 ± 6.11 Gy), with marginal to no significant difference between RPP plans and expert plans for all other OAR dosimetric indices. For the bilateral cases, the V100 for all clinical target volumes (CTVs) was higher for the RPP plans than for the expert plans, especially the CTV_primary V100 (5.08% ± 3.02%), with no significant difference in the HI. With respect to OAR sparing, RPP plans had a lower spinal cord Dmax (-5.74 ± 5.72 Gy), lower cochlea Dmean (left, -6.05 ± 4.33 Gy; right, -4.84 ± 4.66 Gy), lower left and right parotid V20Gy (left, -6.45% ± 5.32%; right, -6.92% ± 3.45%), and a lower integral dose (-0.19 ± 0.19 Gy). However, RPP plans increased the Dmax in the body outside of CTV (body-CTV) (1.2 ± 1.43 Gy), indicating a slightly higher hotspot produced by the RPP plans. CONCLUSION: IMPT plans generated by a broad-scope RPP model have a quality that is, at minimum, comparable with, and at times superior to, that of the expert plans. The RPP plans demonstrated a greater robustness for CTV coverage and better sparing for several OARs.

15.
Sci Rep ; 11(1): 22737, 2021 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-34815464

RESUMO

This study provides a quantitative assessment of the accuracy of a commercially available deformable image registration (DIR) algorithm to automatically generate prostate contours and additionally investigates the robustness of radiomic features to differing contours. Twenty-eight prostate cancer patients enrolled on an institutional review board (IRB) approved protocol were selected. Planning CTs (pCTs) were deformably registered to daily cone-beam CTs (CBCTs) to generate prostate contours (auto contours). The prostate contours were also manually drawn by a physician. Quantitative assessment of deformed versus manually drawn prostate contours on daily CBCT images was performed using Dice similarity coefficient (DSC), mean distance-to-agreement (MDA), difference in center-of-mass position (ΔCM) and difference in volume (ΔVol). Radiomic features from 6 classes were extracted from each contour. Lin's concordance correlation coefficient (CCC) and mean absolute percent difference in radiomic feature-derived data (mean |%Δ|RF) between auto and manual contours were calculated. The mean (± SD) DSC, MDA, ΔCM and ΔVol between the auto and manual prostate contours were 0.90 ± 0.04, 1.81 ± 0.47 mm, 2.17 ± 1.26 mm and 5.1 ± 4.1% respectively. Of the 1,010 fractions under consideration, 94.8% of DIRs were within TG-132 recommended tolerance. 30 radiomic features had a CCC > 0.90 and 21 had a mean |%∆|RF < 5%. Auto-propagation of prostate contours resulted in nearly 95% of DIRs within tolerance recommendations of TG-132, leading to the majority of features being regarded as acceptably robust. The use of auto contours for radiomic feature analysis is promising but must be done with caution.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias da Próstata/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia
16.
Int J Part Ther ; 8(2): 62-72, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34722812

RESUMO

PURPOSE: To assess the performance of a proton-specific knowledge based planning (KBPP) model in creation of robustly optimized intensity-modulated proton therapy (IMPT) plans for treatment of patients with prostate cancer. MATERIALS AND METHODS: Forty-five patients with localized prostate cancer, who had previously been treated with volumetric modulated arc therapy, were selected and replanned with robustly optimized IMPT. A KBPP model was generated from the results of 30 of the patients, and the remaining 15 patient results were used for validation. The KBPP model quality and accuracy were evaluated with the model-provided organ-at-risk regression plots and metrics. The KBPP quality was also assessed through comparison of expert and KBPP-generated IMPT plans for target coverage and organ-at-risk sparing. RESULTS: The resulting R 2 (mean ± SD, 0.87 ± 0.07) between dosimetric and geometric features, as well as the χ2 test (1.17 ± 0.07) between the original and estimated data, showed the model had good quality. All the KBPP plans were clinically acceptable. Compared with the expert plans, the KBPP plans had marginally higher dose-volume indices for the rectum V65Gy (0.8% ± 2.94%), but delivered a lower dose to the bladder (-1.06% ± 2.9% for bladder V65Gy). In addition, KBPP plans achieved lower hotspot (-0.67Gy ± 2.17Gy) and lower integral dose (-0.09Gy ± 0.3Gy) than the expert plans did. Moreover, the KBPP generated better plans that demonstrated slightly greater clinical target volume V95 (0.1% ± 0.68%) and lower homogeneity index (-1.13 ± 2.34). CONCLUSIONS: The results demonstrated that robustly optimized IMPT plans created by the KBPP model are of high quality and are comparable to expert plans. Furthermore, the KBPP model can generate more-robust and more-homogenous plans compared with those of expert plans. More studies need to be done for the validation of the proton KBPP model at more-complicated treatment sites.

17.
Int J Radiat Oncol Biol Phys ; 111(1): 220-232, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33964351

RESUMO

PURPOSE: The gold nanoparticle (GNP) as a promising theranostic probe has been increasingly studied. The tumor-targeting efficiency of GNPs is crucial to increase the therapeutic ratio. In this study, we developed PSMA-targeted GNPs to enhance GNP uptake in prostate cancer and developed an x-ray fluorescence imaging system to noninvasively monitor and assess GNP delivery. METHODS AND MATERIALS: For targeted therapy of prostate cancer, anti-prostate-specific membrane antigen (PSMA) antibodies were conjugated onto PEGylated GNPs through 1-ethyl-3-(-3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) (EDC/NHS) chemistry. In vivo imaging was implemented using an in-house-developed dual-modality computed tomography (CT) and x-ray fluorescence CT (XFCT) system on mice bearing subcutaneous LNCaP prostate tumors. After intravenous administration of GNPs (15 mg/mL, 200 µL), the x-ray fluorescence signals from the tumor were collected at various time points (5 minutes to approximately 30 hours) for GNP pharmacokinetics analysis. At 24 hours after administration, x-ray fluorescence projection (XRFproj) and XFCT imaging were conducted to evaluate the prostate tumor uptake of active- and passive-targeting GNPs. Inductively coupled plasma mass spectrometry analysis was adopted as a benchmark to verify the quantification accuracy of XRFproj/XFCT imaging. RESULTS: Fluorescence microscopic imaging confirmed the enhanced (approximately 4 times) targeting efficiency of PSMA-targeted GNPs in vitro. The pharmacokinetics analysis showed enhanced tumor uptake/retention of PSMA-targeted GNPs and revealed that the peak tumor accumulation appeared at approximately 24 hours after intravenous administration. Both XRFproj and XFCT imaging presented their accuracy in quantifying GNPs within tumors noninvasively. Moreover, XFCT imaging verified its unique capabilities to simultaneously determine the heterogeneous spatial distribution and the concentration of GNPs within tumors in vivo. CONCLUSIONS: In conjunction with PSMA-targeted GNPs, XRFproj/XFCT would be a highly sensitive tool for targeted imaging of prostate cancer, benefiting the elucidation of mechanisms of GNP-assisted prostate-cancer therapy.


Assuntos
Antígenos de Superfície/análise , Glutamato Carboxipeptidase II/análise , Ouro/farmacocinética , Nanopartículas Metálicas , Imagem Óptica/métodos , Neoplasias da Próstata/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Animais , Antígenos de Superfície/imunologia , Glutamato Carboxipeptidase II/imunologia , Humanos , Masculino , Camundongos , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/terapia
18.
Int J Part Ther ; 7(4): 29-41, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33829071

RESUMO

PURPOSE: Anatomical changes and patient setup uncertainties during intensity modulated proton therapy (IMPT) of head and neck (HN) cancers demand frequent evaluation of delivered dose. This work investigated a cone-beam computed tomography (CBCT) and deformable image registration based therapy workflow to demonstrate the feasibility of proton dose calculation on synthetic computed tomography (sCT) for adaptive IMPT treatment of HN cancer. MATERIALS AND METHODS: Twenty-one patients with HN cancer were enrolled in this study, a retrospective institutional review board protocol. They had previously been treated with volumetric modulated arc therapy and had daily iterative CBCT. For each patient, robust optimization (RO) IMPT plans were generated using ±3 mm patient setup and ±3% proton range uncertainties. The sCTs were created and the weekly delivered dose was recalculated using an adaptive dose accumulation workflow in which the planning computed tomography (CT) was deformably registered to CBCTs and Hounsfield units transferred from the planning CT. Accumulated doses from ±3 mm/±3% RO-IMPT plans were evaluated using clinical dose-volume constraints for targets (clinical target volume, or CTV) and organs at risk. RESULTS: Evaluation of weekly recalculated dose on sCTs showed that most of the patient plans maintained target dose coverage. The primary CTV remained covered by the V95 > 95% (95% of the volume receiving more than 95% of the prescription dose) worst-case scenario for 84.5% of the weekly fractions. The oral cavity accumulated mean dose remained lower than the worst-case scenario for all patients. Parotid accumulated mean dose remained within the uncertainty bands for 18 of the 21 patients, and all were kept lower than RO-IMPT worst-case scenario for 88.7% and 84.5% for left and right parotids, respectively. CONCLUSION: This study demonstrated that RO-IMPT plans account for most setup and anatomical uncertainties, except for large weight-loss changes that need to be tracked throughout the treatment course. We showed that sCTs could be a powerful decision tool for adaptation of these cases in order to reduce workload when using repeat CTs.

19.
Med Phys ; 48(5): 2386-2399, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33598943

RESUMO

PURPOSE: Radiomic features of cone-beam CT (CBCT) images have potential as biomarkers to predict treatment response and prognosis for patients of prostate cancer. Previous studies of radiomic feature analysis for prostate cancer were assessed in a variety of imaging modalities, including MRI, PET, and CT, but usually limited to a pretreatment setting. However, CBCT images may provide an opportunity to capture early morphological changes to the tumor during treatment that could lead to timely treatment adaptation. This work investigated the quality of CBCT-based radiomic features and their relationship with reconstruction methods applied to the CBCT projections and the preprocessing methods used in feature extraction. Moreover, CBCT features were correlated with planning CT (pCT) features to further assess the viability of CBCT radiomic features. METHODS: The quality of 42 CBCT-based radiomic features was assessed according to their repeatability and reproducibility. Repeatability was quantified by correlating radiomic features between 20 CBCT scans that also had repeated scans within 15 minutes. Reproducibility was quantified by correlating radiomic features between the planning CT (pCT) and the first fraction CBCT for 20 patients. Concordance correlation coefficients (CCC) of radiomic features were used to estimate the repeatability and reproducibility of radiomic features. The same patient dataset was assessed using different reconstruction methods applied to the CBCT projections. CBCT images were generated using 18 reconstruction methods using iterative (iCBCT) and standard (sCBCT) reconstructions, three convolution filters, and five noise suppression filters. Eighteen preprocessing settings were also considered. RESULTS: Overall, CBCT radiomic features were more repeatable than reproducible. Five radiomic features are repeatable in > 97% of the reconstruction and preprocessing methods, and come from the gray-level size zone matrix (GLSZM), neighborhood gray-tone difference matrix (NGTDM), and gray-level-run length matrix (GLRLM) radiomic feature classes. These radiomic features were reproducible in > 9.8% of the reconstruction and preprocessing methods. Noise suppression and convolution filter smoothing increased radiomic features repeatability, but decreased reproducibility. The top-repeatable iCBCT method (iCBCT-Sharp-VeryHigh) is more repeatable than the top-repeatable sCBCT method (sCBCT-Smooth) in 64% of the radiomic features. CONCLUSION: Methods for reconstruction and preprocessing that improve CBCT radiomic feature repeatability often decrease reproducibility. The best approach may be to use methods that strike a balance repeatability and reproducibility such as iCBCT-Sharp-VeryLow-1-Lloyd-256 that has 17 repeatable and eight reproducible radiomic features. Previous radiomic studies that only used pCT radiomic features have generated prognostic models of prostate cancer outcome. Since our study indicates that CBCT radiomic features correlated well with a subset of pCT radiomic features, one may expect CBCT radiomics to also generate prognostic models for prostate cancer.


Assuntos
Neoplasias da Próstata , Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico , Humanos , Imageamento por Ressonância Magnética , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes
20.
Phys Med ; 81: 77-85, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33445124

RESUMO

PURPOSE: To implement a daily CBCT based dose accumulation technique in order to assess ideal robust optimization (RO) parameters for IMPT treatment of prostate cancer. METHODS: Ten prostate cancer patients previously treated with VMAT and having daily CBCT were included. First, RO-IMPT plans were created with ± 3 mm and ± 5 mm patient setup and ± 3% proton range uncertainties, respectively. Second, the planning CT (pCT) was deformably registered to the CBCT to create a synthetic CT (sCT). Both daily and weekly sampling strategies were employed to determine optimal dose accumulation frequency. Doses were recalculated on sCTs for both ± 3 mm/±3% and ± 5 mm/±3% uncertainties and were accumulated back to the pCT. Accumulated doses generated from ± 3 mm/±3% and ± 5 mm/±3% RO-IMPT plans were evaluated using the clinical dose volume constraints for CTV, bladder, and rectum. RESULTS: Daily accumulated dose based on both ± 3mm/±3% and ±5 mm/±3% uncertainties for RO-IMPT plans resulted in satisfactory CTV coverage (RO-IMPT3mm/3% CTVV95 = 99.01 ± 0.87% vs. RO-IMPT5mm/3% CTVV95 = 99.81 ± 0.2%, P = 0.002). However, the accumulated dose based on ± 3 mm/3% RO-IMPT plans consistently provided greater OAR sparing than ±5 mm/±3% RO-IMPT plans (RO-IMPT3mm/3% rectumV65Gy = 2.93 ± 2.39% vs. RO-IMPT5mm/3% rectumV65Gy = 4.38 ± 3%, P < 0.01; RO-IMPT3mm/3% bladderV65Gy = 5.2 ± 7.12% vs. RO-IMPT5mm/3% bladderV65Gy = 7.12 ± 9.59%, P < 0.01). The gamma analysis showed high dosimetric agreement between weekly and daily accumulated dose distributions. CONCLUSIONS: This study demonstrated that for RO-IMPT optimization, ±3mm/±3% uncertainty is sufficient to create plans that meet desired CTV coverage while achieving superior sparing to OARs when compared with ± 5 mm/±3% uncertainty. Furthermore, weekly dose accumulation can accurately estimate the overall dose delivered to prostate cancer patients.


Assuntos
Neoplasias da Próstata , Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...