Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Endovasc Ther ; : 15266028231215212, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38053508

RESUMO

PURPOSE: to assess the safety and efficacy of APERTO-Paclitaxel-coated balloon angioplasty versus standard angioplasty for the treatment of dysfunctional hemodialysis shunts and native arteriovenous fistulae. METHODS: consecutive patients with dysfunctional dialysis related to underlying efferent vein stenosis were included and randomized 1:1 to either APERTO-paclitaxel drug-coated balloon (study arm) or standard percutaneous transluminal angioplasty (control arm). Primary endpoint is time from treatment until dialysis access dysfunction according to standardized Kidney Disease Outcomes Quality Initiative (KDOQI)-guidelines and assessed by Kaplan-Meier survival curves and tested for significance with log-rank analysis. Secondary endpoints include device, technical, and clinical success of the index angioplasty procedure. RESULTS: The study included 103 patients (n=51 study-group) with a de novo (n=33) dysfunctional native arteriovenous fistula (n=79) in the forearm (n=60). The majority of included patients were male with a mean age of 69.8 years, presenting with a dysfunctioning autologous arteriovenous fistula in the forearm. Device-related complications did not occur in any of the included patients. Functional hemodialysis access without need for re-intervention at 1 year after index procedure was found in n=10 (19.6%) and n=5 (9.6%) of patients treated with, respectively, paclitaxel drug-coated balloon and percutaneous transluminal angioplasty (p=0.612). A nonsignificant benefit of paclitaxel drug-coated balloon (n=5; 25%) over percutaneous transluminal angioplasty (n=1; 11%) was found (p=0.953) in de novo lesions in autologous fistulas. CONCLUSION: APERTO-paclitaxel drug-coated balloon is a safe balloon catheter to manage dysfunctional hemodialysis access; however, longer period of adequate hemodialysis circuit functioning after endovascular index stenosis treatment, using APERTO-paclitaxel drug-coated balloon versus percutaneous transluminal angioplasty could not be demonstrated. CLINICAL IMPACT: APERTO-paclitaxel drug-coated balloon catheter is a safe device to manage dysfunctional hemodialysis access. Compared to conventional angioplasty balloon, the APERTO drug-coated balloon will not result in longer period of adequate hemodialysis circuit functioning. A non-significant benefit of APERTO drug-coated balloon was found in de novo lesions in autologous fistulas.

2.
J Endovasc Ther ; 13(6): 770-4, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17154709

RESUMO

PURPOSE: To present a case of successful emergency endovascular repair of a ruptured, probably mycotic, thoracoabdominal aortic aneurysm (TAAA) with a stent-graft deliberately covering the celiac axis. CASE REPORT: A 79-year-old woman with significant pulmonary comorbidity presented with a ruptured mycotic TAAA extending to the celiac axis. The aneurysm was excluded with a stent-graft soaked in rifampicin and deployed to deliberately occlude the celiac axis for effective distal sealing and fixation. The patient recovered well and was prescribed antibiotic treatment for up to 6 months. CONCLUSION: Endovascular repair of a ruptured TAAA may be a life-saving option. In emergency situations when poor distal anatomy is present, covering the celiac artery with the stent-graft should be considered.


Assuntos
Aneurisma Infectado/terapia , Angioplastia com Balão/métodos , Aneurisma da Aorta Abdominal/terapia , Aneurisma da Aorta Torácica/terapia , Ruptura Aórtica/terapia , Implante de Prótese Vascular/métodos , Artéria Celíaca , Stents , Dor Abdominal/etiologia , Idoso , Aneurisma Infectado/complicações , Aneurisma Infectado/diagnóstico por imagem , Angiografia , Antibacterianos/uso terapêutico , Antibióticos Antituberculose , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Ruptura Aórtica/complicações , Ruptura Aórtica/diagnóstico por imagem , Diarreia/etiologia , Emergências , Fadiga/etiologia , Feminino , Febre/etiologia , Humanos , Seleção de Pacientes , Desenho de Prótese , Rifampina , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...