Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(11)2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38894016

RESUMO

We investigated micro-threaded stem taper surface and its impact on premature failures, aseptic loosening, and infection in cementless hip endoprostheses. Our study focused on the fretting, and crevice corrosion of micro-threaded tapers, as well as the characterization of the microstructure and surface properties of two new and three retrieved Zweymüller stem tapers. The retrieved samples were selected and examined based on the head-stem taper interface being the sole source of modularity with a metallic component, specifically between the Ti alloy taper stem and the ceramic head. To determine the surface chemistry and microstructures of both new and retrieved hip endoprostheses stem taper titanium alloy, scanning -electron microscopy (SEM) was employed for morphological and microstructural analyses. Energy dispersive spectroscopy (EDS) was utilized for characterizing chemical element distribution, and electron backscattered diffraction (EBSD) was used for phase analysis. The roughness of the micro-threated stem tapers from different manufacturers was investigated using an optical profilometer, with standard roughness parameters Ra (average surface roughness) and Rz (mean peak to valley height of the roughness profile) being measured. Electrochemical studies revealed no fretting corrosion in retrieved stem tapers with ceramic heads. Consequently, three retrieved tapers and two new ones for comparison underwent potentiodynamic measurements in Hank's solution to determine the corrosion rate of new and retrieved stem taper surfaces. The results showed a low corrosion rate for both new and prematurely failed retrieved samples due to aseptic loosening. However, the corrosion rate was higher in infected and low-grade infected tapers. In conclusion, our study suggests that using ceramic heads reduces taper corrosion and subsequently decreases the incidence of premature failures in total hip arthroplasty.

2.
Materials (Basel) ; 16(21)2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37959464

RESUMO

For the improvement of surface roughness, titanium joint arthroplasty (TJA) components are grit-blasted with Al2O3 (corundum) particles during manufacturing. There is an acute concern, particularly with uncemented implants, about polymeric, metallic, and corundum debris generation and accumulation in TJA, and its association with osteolysis and implant loosening. The surface morphology, chemistry, phase analysis, and surface chemistry of retrieved and new Al2O3 grit-blasted titanium alloy were determined with scanning electron microscopy (SEM), X-ray energy-dispersive spectroscopy (EDS), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and confocal laser fluorescence microscopy, respectively. Peri-prosthetic soft tissue was studied with histopathology. Blasted retrieved and new stems were exposed to human mesenchymal stromal stem cells (BMSCs) for 7 days to test biocompatibility and cytotoxicity. We found metallic particles in the peri-prosthetic soft tissue. Ti6Al7Nb with the residual Al2O3 particles exhibited a low cytotoxic effect while polished titanium and ceramic disks exhibited no cytotoxic effect. None of the tested materials caused cell death or even a zone of inhibition. Our results indicate a possible biological effect of the blasting debris; however, we found no significant toxicity with these materials. Further studies on the optimal size and properties of the blasting particles are indicated for minimizing their adverse biological effects.

3.
Materials (Basel) ; 16(9)2023 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-37176169

RESUMO

We studied inflammatory and oxidative stress-related parameters and cytotoxic response of human umbilical vein endothelial cells (HUVEC) to a 24 h treatment with milled particles simulating debris involved in sandblasting of orthopedic implants (OI). We used different abrasives (corundum-(Al2O3), used corundum retrieved from removed OI (u. Al2O3), and zirconia/silica composite (ZrO2/SiO2)). Morphological changes were observed by scanning electron microscopy (SEM). Concentration of Interleukins IL-6 and IL-1ß and Tumor Necrosis Factor α (TNF)-α was assessed by enzyme-linked immunosorbent assay (ELISA). Activity of Cholinesterase (ChE) and Glutathione S-transferase (GST) was measured by spectrophotometry. Reactive oxygen species (ROS), lipid droplets (LD) and apoptosis were measured by flow cytometry (FCM). Detachment of the cells from glass and budding of the cell membrane did not differ in the treated and untreated control cells. Increased concentration of IL-1ß and of IL-6 was found after treatment with all tested particle types, indicating inflammatory response of the treated cells. Increased ChE activity was found after treatment with u. Al2O3 and ZrO2/SiO2. Increased GST activity was found after treatment with ZrO2/SiO2. Increased LD quantity but not ROS quantity was found after treatment with u. Al2O3. No cytotoxicity was detected after treatment with u. Al2O3. The tested materials in concentrations added to in vitro cell lines were found non-toxic but bioactive and therefore prone to induce a response of the human body to OI.

4.
Int J Mol Sci ; 24(4)2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36834843

RESUMO

The preparation of autologous platelet and extracellular vesicle-rich plasma (PVRP) has been explored in many medical fields with the aim to benefit from its healing potential. In parallel, efforts are being invested to understand the function and dynamics of PVRP that is complex in its composition and interactions. Some clinical evidence reveals beneficial effects of PVRP, while some report that there were no effects. To optimize the preparation methods, functions and mechanisms of PVRP, its constituents should be better understood. With the intention to promote further studies of autologous therapeutic PVRP, we performed a review on some topics regarding PVRP composition, harvesting, assessment and preservation, and also on clinical experience following PVRP application in humans and animals. Besides the acknowledged actions of platelets, leukocytes and different molecules, we focus on extracellular vesicles that were found abundant in PVRP.


Assuntos
Plasma Rico em Plaquetas , Humanos , Animais , Plaquetas , Cicatrização , Leucócitos
5.
Comput Methods Biomech Biomed Engin ; 22(14): 1107-1115, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31429314

RESUMO

The biomechanical parameters of the hip joint articular surface were analysed in 141 adult hips after Legg-Calve Perthes Disease, and 114 contralateral unaffected hips (controls), by using HIPSTRESS mathematical models. Geometrical parameters, assessed from anteroposterior and axial radiograms, were used as input to models for resultant hip force and contact hip stress. Results confirm previous indications that head enlargement after the Legg-Calve-Perthes Disease compensates the values of hip stress. Furthermore, it was found that an increased risk for coxarthritis development after the disease is secondary to concomitant hip dysplasia, with considerable and statistically significantly lower centre-edge angle and unfavourable distribution of stress.


Assuntos
Artrite/etiologia , Luxação do Quadril/complicações , Quadril/patologia , Doença de Legg-Calve-Perthes/complicações , Artrite/fisiopatologia , Fenômenos Biomecânicos , Quadril/diagnóstico por imagem , Quadril/fisiopatologia , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/fisiopatologia , Humanos , Doença de Legg-Calve-Perthes/diagnóstico por imagem , Doença de Legg-Calve-Perthes/fisiopatologia
6.
Eur J Orthop Surg Traumatol ; 29(4): 793-799, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30680543

RESUMO

PURPOSE: Patients with equal objective leg length discrepancy (LLD) may have different subjective perceptions of this condition. Our aim was to analyze the effects of gender, age, operated side, surgical approach, body height, body mass index (BMI) and LLD measurements on self-perceived LLD after total hip arthroplasty (THA). MATERIALS AND METHODS: Observational cohort study with minimum 5-year follow-up included 159 patients with unilateral primary THA at a single institution, who reported subjective feeling of equal or unequal leg lengths after THA. Gender, age, body height, BMI, surgical approach, preoperative and postoperative absolute/relative/pelvic radiographic LLD measurements were included in direct comparison between groups and multivariate analyses with self-perceived LLD as the outcome variable. RESULTS: Out of 159 participants, 39% subjectively perceived postoperative LLD, while others reported equal leg lengths. The two groups postoperatively differed in the median relative LLD (10 mm vs. 5 mm; p = 0.01) and WOMAC (230 mm vs. 110 mm; p < 0.01), but not in the pelvic radiographic LLD. After adjustment for gender, age, operated side and surgical approach, postoperative relative LLD (odds ratio 1.38 for each 5 mm increment; 95% CI 1.01-1.74) and combination of BMI < 26 kg/m2 and body height < 1.75 m (odds ratio 2.49; 95% CI 1.14-5.41) were independent risk factors for self-perceived LLD. CONCLUSIONS: Clinical relative LLD measurements are better predictors of self-perceived postoperative LLD than pelvic radiographic measurements. Patients with smaller body dimensions will more likely report subjective leg length inequality at a given objective LLD, regardless of gender or age.


Assuntos
Artroplastia de Quadril/efeitos adversos , Desigualdade de Membros Inferiores/etiologia , Estatura , Índice de Massa Corporal , Estudos de Coortes , Feminino , Seguimentos , Humanos , Desigualdade de Membros Inferiores/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Avaliação de Resultados da Assistência ao Paciente , Complicações Pós-Operatórias , Fatores de Risco , Autorrelato
7.
J Biomech ; 49(16): 3996-4001, 2016 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-27842781

RESUMO

In vivo linear penetration in total hip arthroplasty (THA) exhibits similar values for 28mm and 32mm femoral head diameter with considerable variations between and within the studies. It indicates factors other than femoral head diameter influence polyethylene wear. This study is intended to test the effect of patient׳s individual geometry of musculoskeletal system, acetabular cup orientation, and radius of femoral head on wear. Variation in patient׳s musculoskeletal geometry and acetabular cup placement is evaluated in two groups of patients implanted with 28mm and 32mm THA heads. Linear wear rate estimated by mathematical model is 0.165-0.185mm/year and 0.157-0.205mm/year for 28 and 32mm THA heads, respectively. Simulations show little influence femoral head size has on the estimated annual wear rate. Predicted annual linear wear depends mostly on the abduction angle of the acetabular cup and individual geometry of the musculoskeletal system of the hip, with the latter having the greatest affect on variation in linear wear rate.


Assuntos
Acetábulo/anatomia & histologia , Artroplastia de Quadril , Cabeça do Fêmur/anatomia & histologia , Prótese de Quadril , Músculo Esquelético/anatomia & histologia , Acetábulo/fisiologia , Idoso , Feminino , Cabeça do Fêmur/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/fisiologia , Modelagem Computacional Específica para o Paciente , Polietileno
8.
Wien Klin Wochenschr ; 127 Suppl 5: S235-40, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25732915

RESUMO

BACKGROUND: Optimal positioning of implants and restoration of neutral mechanical axis are two primary surgical goals in total knee arthroplasty (TKA). Despite modern instruments and improved surgical techniques, malalignment remains an important cause of early failure after TKA. The aim of this prospective randomized study was to compare the value of a new patient-matched instrument system (PMI) (Signature(TM); Biomet, Inc, Warsaw, Indiana) to that of standard TKA surgical instrumentation (STD) in terms of coronal mechanical alignment, time of operation and blood loss. PATIENTS AND METHODS: A total of 38 patients waiting for primary TKA were enrolled and randomized into two groups (19 PMI and 19 STD). Magnetic resonance imaging was performed in all patients in the PMI group, and specific instruments for the femur and tibia were designed preoperatively. All patients were operated on using the standard medial parapatellar approach with no use of tourniquet. Mechanical axis, time for the operation, and blood loss were evaluated. RESULTS: Patients in both groups had comparable age, body mass index, preoperative mechanical axis, Knee Society Score, and level of hemoglobin. Postoperative results showed that the PMI group fell significantly closer to neutral mechanical axis (STD: 2.7 ± 1.7, PMI: 1.7 ± 0.9; P = 0.013) with no outliers and a reduced time for the operation. There was no difference in the evaluation blood loss. CONCLUSIONS: The use of PMI can contribute in achieving better mechanical axis with reduction in outliers and decreased operation time. Due to small differences between PMI and standard instruments, additional research are needed to confirm these preliminary results, and to discover potential benefits and functional improvements in the long-term outcome.


Assuntos
Artroplastia do Joelho/efeitos adversos , Perda Sanguínea Cirúrgica/prevenção & controle , Prótese do Joelho/efeitos adversos , Duração da Cirurgia , Osteoartrite do Joelho/cirurgia , Hemorragia Pós-Operatória/etiologia , Idoso , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Osteoartrite do Joelho/diagnóstico , Hemorragia Pós-Operatória/prevenção & controle , Estudos Prospectivos , Resultado do Tratamento
9.
J Arthroplasty ; 29(1): 137-41, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23680505

RESUMO

In a single-surgeon series of 119 patients with unilateral primary uncemented total hip arthroplasty, four leg-length discrepancy measurement methods (absolute, relative, trochanteric, standardized-trochanteric) were analyzed for their impact on WOMAC score, Oxford Hip Score and self-perceived leg-length discrepancy. After adjustment for age, gender and BMI, postoperative WOMAC scores correlated only with clinical absolute measurements of leg elongation (P=0.05). Self-perceived leg-length discrepancy corresponded best to the clinically measured relative leg-length discrepancy (11 mm perceived vs. 7 mm unperceived; P=0.04) while there was no significant correspondence with radiographic measurements or leg elongation magnitudes. Within the <10 mm range of mean postoperative leg length discrepancy in the studied series, its impact on the overall clinical satisfaction was detectable but not considerable.


Assuntos
Artroplastia de Quadril/métodos , Articulação do Quadril/cirurgia , Artropatias/cirurgia , Desigualdade de Membros Inferiores/diagnóstico , Pesos e Medidas Corporais , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Prótese de Quadril , Humanos , Perna (Membro)/diagnóstico por imagem , Perna (Membro)/cirurgia , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Radiografia , Resultado do Tratamento
10.
Biomed Mater ; 5(4): 045012, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20683125

RESUMO

The total replacement of joints by the implantation of permanently indwelling prosthetic components has been one of the major successes of modern surgery in terms of relieving pain and correcting deformity. However, the aseptic loosening of a prosthetic-joint component is the most common reason for joint-revision surgery. Furthermore, it is thought that wear particles are one of the major contributors to the development and perpetuation of aseptic loosening. The aim of the present study was to identify the factors related to the aseptic loosening of an AISI 316L stainless steel total hip prosthesis. The stem was evaluated by x-ray photoelectron spectroscopy, with polished and rough regions being analyzed in order to establish the differences in the chemical compositions of both regions. Specific areas were examined using scanning electron microscopy with energy dispersive x-ray spectroscopy and light microscopy.


Assuntos
Articulação do Quadril/patologia , Prótese de Quadril/efeitos adversos , Instabilidade Articular/etiologia , Instabilidade Articular/patologia , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/patologia , Aço Inoxidável/efeitos adversos , Análise de Falha de Equipamento , Articulação do Quadril/efeitos dos fármacos , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
11.
Cell Mol Biol Lett ; 14(4): 636-56, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19554268

RESUMO

Cells interact by exchanging material and information. Two methods of cell-to-cell communication are by means of microvesicles and by means of nanotubes. Both microvesicles and nanotubes derive from the cell membrane and are able to transport the contents of the inner solution. In this review, we describe two physical mechanisms involved in the formation of microvesicles and nanotubes: curvature-mediated lateral redistribution of membrane components with the formation of membrane nanodomains; and plasmamediated attractive forces between membranes. These mechanisms are clinically relevant since they can be affected by drugs. In particular, the underlying mechanism of heparin's role as an anticoagulant and tumor suppressor is the suppression of microvesicluation due to plasma-mediated attractive interaction between membranes.


Assuntos
Comunicação Celular , Membrana Celular/ultraestrutura , Nanotubos/ultraestrutura , Animais , Transporte Biológico , Membrana Celular/metabolismo , Heparina/metabolismo , Humanos
12.
Clin Orthop Relat Res ; 447: 92-9, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16505705

RESUMO

Contact stress distribution in the articular surface of the hip is considered a factor in the development of osteoarthritis, a common complication in hips with aseptic necrosis of the femoral head. We present evidence supporting the hypothesis that osteoarthritis in hips with aseptic necrosis of the femoral head can be caused by elevated contact stress related to the reduced load-bearing ability of the necrotic bone. By using a previously validated mathematical model, we observed that hip contact stress may increase considerably if the load-bearing capacity of the necrotic lesion is decreased, if the size of the necrotic segment is increased, and if the necrotic segment is located more laterally. These effects are affected by the intrinsic shape of the hip. As the estimated values of stress in hips with osteonecrosis are in the range obtained by the same method in dysplastic hips, osteoarthritis in hips with osteonecrosis can be caused by elevated contact stress.


Assuntos
Fenômenos Biomecânicos , Necrose da Cabeça do Fêmur/etiologia , Articulação do Quadril/fisiologia , Osteoartrite do Quadril/etiologia , Força Compressiva , Necrose da Cabeça do Fêmur/fisiopatologia , Humanos , Modelos Anatômicos , Modelos Teóricos , Osteoartrite do Quadril/fisiopatologia , Medição de Risco , Sensibilidade e Especificidade , Estresse Mecânico , Suporte de Carga
13.
ISA Trans ; 43(4): 527-38, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15535392

RESUMO

This paper deals with the tracking control design of a linear synchronous reluctance motor (LSRM) drive. An extended nonlinear dynamic LSRM model with magnetic saturation included is used in the control design and practical realization, in order to improve tracking performances at very low speeds of motion. Iron core saturation is included in the extended model with the experimentally determined flux linkages given as functions of the direct and quadrature axes currents. Experimental results show that the proposed input-output linearizing tracking control with included saturation behaves considerably better than the one without saturation, introducing smaller position and speed errors and better motor stiffness, on account of the increased computational complexity.

14.
Cell Mol Biol Lett ; 7(1): 109-11, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11944058

RESUMO

We were interested in whether or not the biomechanical status of the hip influences the course of avascular necrosis of the femoral head. To investigate this, we used a computer aided system based on a three dimensional mathematical model for determining the stress distribution in the hip joint from standard anteroposterior rentgenographs (X-ray images) of both hips and pelvis. Based on the results of our study, we suggest that the biomechanical parameters of the hip play an important role in the outcome of treatment of hips affected by avascular necrosis of the femoral head.


Assuntos
Cabeça do Fêmur/irrigação sanguínea , Cabeça do Fêmur/patologia , Quadril/anatomia & histologia , Quadril/cirurgia , Fenômenos Biomecânicos , Transplante Ósseo , Humanos , Necrose , Osteotomia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...