Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 14(1): 4536, 2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-37669984

RESUMO

Classical novae are thermonuclear explosions in stellar binary systems, and important sources of 26Al and 22Na. While γ rays from the decay of the former radioisotope have been observed throughout the Galaxy, 22Na remains untraceable. Its half-life (2.6 yr) would allow the observation of its 1.275 MeV γ-ray line from a cosmic source. However, the prediction of such an observation requires good knowledge of its nucleosynthesis. The 22Na(p, γ)23Mg reaction remains the only source of large uncertainty about the amount of 22Na ejected. Its rate is dominated by a single resonance on the short-lived state at 7785.0(7) keV in 23Mg. Here, we propose a combined analysis of particle-particle correlations and velocity-difference profiles to measure femtosecond nuclear lifetimes. The application of this method to the study of the 23Mg states, places strong limits on the amount of 22Na produced in novae and constrains its detectability with future space-borne observatories.

3.
Sci Rep ; 12(1): 2735, 2022 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-35177663

RESUMO

Compton imaging represents a promising technique for range verification in proton therapy treatments. In this work, we report on the advantageous aspects of the i-TED detector for proton-range monitoring, based on the results of the first Monte Carlo study of its applicability to this field. i-TED is an array of Compton cameras, that have been specifically designed for neutron-capture nuclear physics experiments, which are characterized by [Formula: see text]-ray energies spanning up to 5-6 MeV, rather low [Formula: see text]-ray emission yields and very intense neutron induced [Formula: see text]-ray backgrounds. Our developments to cope with these three aspects are concomitant with those required in the field of hadron therapy, especially in terms of high efficiency for real-time monitoring, low sensitivity to neutron backgrounds and reliable performance at the high [Formula: see text]-ray energies. We find that signal-to-background ratios can be appreciably improved with i-TED thanks to its light-weight design and the low neutron-capture cross sections of its LaCl[Formula: see text] crystals, when compared to other similar systems based on LYSO, CdZnTe or LaBr[Formula: see text]. Its high time-resolution (CRT [Formula: see text] 500 ps) represents an additional advantage for background suppression when operated in pulsed HT mode. Each i-TED Compton module features two detection planes of very large LaCl[Formula: see text] monolithic crystals, thereby achieving a high efficiency in coincidence of 0.2% for a point-like 1 MeV [Formula: see text]-ray source at 5 cm distance. This leads to sufficient statistics for reliable image reconstruction with an array of four i-TED detectors assuming clinical intensities of 10[Formula: see text] protons per treatment point. The use of a two-plane design instead of three-planes has been preferred owing to the higher attainable efficiency for double time-coincidences than for threefold events. The loss of full-energy events for high energy [Formula: see text]-rays is compensated by means of machine-learning based algorithms, which allow one to enhance the signal-to-total ratio up to a factor of 2.


Assuntos
Diagnóstico por Imagem , Processamento de Imagem Assistida por Computador , Aprendizado de Máquina , Terapia com Prótons , Imagens de Fantasmas
4.
IEEE Trans Med Imaging ; 28(12): 2007-14, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19628451

RESUMO

The performance of a position sensitive gamma-ray scintillator detector (PSD) is described. This PSD is based on a lutetium yttrium oxyorthosilicate (LYSO) crystal read out by a crossed-wire anode position sensitive photomultiplier tube (PSPMT). The main difference with respect to similar existing devices is the individual multi-anode readout (IMAR) approach that is followed here. This method allows to exploit better the intrinsic characteristics of the PSPMT, thus yielding better linearity, improved spatial resolution, and a larger field of view. The new detector is intended for the characterization of 3-D position sensitive germanium detectors.


Assuntos
Câmaras gama , Aumento da Imagem/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Transdutores , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...