Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Neurosurg Spine ; : 1-8, 2019 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-30849746

RESUMO

OBJECTIVETraditional trajectory (TT) screws are widely used in lumbar fixation. However, they may require revision surgery in some instances, especially in patients with osteoporotic spines. Cortical bone trajectory (CBT) screws may potentially be used to rescue a failed TT screw and vice versa in nonosteoporotic spines. This study aimed to investigate whether a CBT screw can salvage a compromised TT screw in osteoporotic lumbar spines and vice versa.METHODSA total of 42 vertebrae from 17 cadaveric lumbar spines were obtained. Bone mineral density was measured, and a CBT screw was randomly inserted into one side of each vertebra. A TT screw was then inserted into the contralateral side. The biomechanical properties of the screws were tested to determine their insertional torque, pullout strength, and fatigue performance. After checking the screws for the failure of each specimen, the failed screw track was salvaged with a screw of the opposite trajectory. The specimen was then subjected to the same mechanical tests, and results were recorded. A repeat pullout test on TT and CBT screws was also performed.RESULTSWhen CBT screws were used to rescue failed TT screws, the original torque increased by 50%, an average of 81% of the pullout strength of the initial TT screws was retained, and the fatigue performance was equal to that of the original screws, which were considerably stronger than the loose TT screws-that is, the TT repeat screws/TT screws were 33% of the pullout strength of the initial TT screws. When the TT screws were used to salvage the compromised CBT screws, the TT screws retained 51% of the original torque and 54% of the original pullout strength, and these screws were still stronger than the loose CBT screws-that is, the loose CBT screws retained 12% pullout strength of the initial CBT screws. Fatigue performance and the ratio of the pullout strength considerably decreased between the CBT rescue screws and the original CBT screws but slightly changed between the TT rescue screws and the original TT screws.CONCLUSIONSCBT and TT screws can be applied in a revision technique to salvage each other in osteoporotic lumbar spines. Additionally, CBT and TT screws each retain adequate insertional torque, pullout strength, and fatigue performance when used for revision in osteoporotic lumbar spines.

2.
Medicine (Baltimore) ; 97(40): e12666, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30290650

RESUMO

BACKGROUND: Because of aging of population, osteoporotic vertebral compression fracture (OVCF) appears an increasing incidence rate. Conservative therapy (CT) and balloon kyphoplasty (BKP) have been used to treat OVCFs. However, an increase in new vertebral compression fractures at nontreated levels following BKP is of concern. It is still not clear whether new fractures were a result of BKP and the purpose of this meta-analysis was to evaluate the new fractures risk after BKP compared with CT. METHODS: An exhaustive literature search of PubMed, EMBASE, and the Cochrane Library was conducted to identify randomized controlled trials and prospective nonrandomized controlled study that compared BKP with CT for patients suffering OVCF. A random-effect model was used. Results were reported as standardized mean difference or risk ratio with 95% confidence interval. RESULTS: Twelve studies were included and there was no significant difference in total new fractures (P = .33) and adjacent fractures (P = .83) between 2 treatments. Subgroup analyses did not demonstrate significant differences in follow-up period, mean age, anti-osteoporosis therapy, and the proportion of women. CONCLUSION: Our systematic review revealed that an increased risk of fracture of vertebral bodies was not associated with BKP compared with CT.


Assuntos
Fraturas por Compressão/cirurgia , Cifoplastia/métodos , Fraturas por Osteoporose/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Ensaios Clínicos como Assunto , Tratamento Conservador , Fraturas por Compressão/complicações , Fraturas por Compressão/terapia , Humanos , Cifoplastia/efeitos adversos , Fraturas por Osteoporose/complicações , Fraturas por Osteoporose/terapia , Fraturas da Coluna Vertebral/complicações , Fraturas da Coluna Vertebral/terapia
3.
World Neurosurg ; 119: e717-e727, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30092463

RESUMO

OBJECTIVE: Selecting optimal strategies for improving fixation in osteoporotic lumbar spine is an important issue in clinical research. Cortical bone trajectory (CBT) screws have been proven to enhance screw pullout strength, but biomechanical efficacy of these screws remains understudied. The aim of this study was to evaluate biomechanical efficacy of CBT screws in osteoporotic lumbar spine. METHODS: Thirty-one vertebrae from 14 cadaveric lumbar spines were obtained. All specimens were measured by computed tomography; the diameter of pedicles, excluding those of vertebral bodies with very small pedicle developments, was calculated. After measuring bone mineral density, the CBT screw was randomly inserted into 1 side, and the traditional trajectory (TT) screw was inserted into the contralateral side. Maximum insertional torque was recorded after screw insertion. Of vertebrae, 21 were subjected to pullout testing at a rate of 5 mm/minute, and 10 were subjected to cyclic fatigue testing. Each construct was loaded until exceeding 5 mm. RESULTS: Average bone mineral density was 0.567 ± 0.101 g/cm2. CBT screws had higher maximum insertional torque (degrees of freedom = 30, t = 5.78, P < 0.001, 0.333 N-m vs. 0.188 N-m) and higher axial pullout strength (degrees of freedom = 20, t = 7.41, P < 0.001, 394 N vs. 241 N) than TT screws. Increased bone mineral density was not significantly associated with higher pullout load. Compared with TT screws, CBT screws showed better resistance to fatigue testing and required more cycles to exceed 5 mm (degrees of freedom = 9, t = 5.62, P < 0.001, 6161 cycles vs. 3639 cycles). Failure load for displacing screws was also significantly greater for CBT screws than for TT screws (degrees of freedom = 9, t = 5.75, P < 0.001, 443 N vs. 317 N). CONCLUSIONS: CBT screws had better biomechanical fixation in osteoporotic lumbar spine compared with standard pedicle screws.


Assuntos
Osso Cortical/cirurgia , Vértebras Lombares/cirurgia , Osteoporose/cirurgia , Parafusos Pediculares/normas , Fraturas da Coluna Vertebral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea/fisiologia , Cadáver , Feminino , Fixação Interna de Fraturas/instrumentação , Humanos , Vértebras Lombares/fisiologia , Masculino , Pessoa de Meia-Idade , Osteoporose/fisiopatologia , Desenho de Prótese , Falha de Prótese , Torque
4.
J Korean Neurosurg Soc ; 59(3): 292-5, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27226863

RESUMO

OBJECTIVE: To investigate the variation of pelvic radius and related parameters in low-grade isthmic lumbar spondylolisthesis. METHODS: Seventy-four patients with isthmic lumbar spondylolisthesis and 47 controls were included in this study. There were 17 males and 57 females between 30 and 66 years of age, including 30 with grade I slippages and 44 grade II slippages; diseased levels included 34 cases on L4 and 40 cases on L5. Thoracic kyphosis (TK), the pelvic radius (PR), the pelvic angle (PA), pelvic morphology (PR-S1), and total lumbopelvic lordosis (PR-T12) were assessed from radiographs. RESULTS: Statistically significant differences were found for the PA, PR-T12, and PR-S1 (24.5±6.6°, 83.7±9.8°, and 25.4±11.2°, respectively) of the patients with spondylolisthesis and the healthy volunteers (13.7±7.8°, 92.9±9.2°, and 40.7±8.9°, respectively). The TK/PR-T12 ratios were between 0.15 and 0.75. However, there were no differences in all the parameters between the L4 and L5 spondylolysis subgroups (p>0.05). The TK and PR-S1 of grade II were less than grade I, but the PA was greater. The PR-T12 of female patients were less than male patients, but the PA was greater (p<0.05). CONCLUSION: Pelvic morphology differed in patients with low-grade isthmic lumbar spondylolisthesis compared to controls. Gender and the grade of slippage impacted the sagittal configuration of the pelvis, but the segment of the vertebral slip did not. Overall, the spine of those with spondylolisthesis remains able to maintain sagittal balance despite abnormal pelvic morphology.

5.
Rheumatology (Oxford) ; 53(6): 998-1008, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24497541

RESUMO

OBJECTIVE: Vitamin D receptor (VDR) gene polymorphisms may be associated with the risk of OA, however, evidence for this is controversial. This meta-analysis aims to confirm whether VDR gene polymorphisms are associated with OA. METHODS: Meta-analyses on the association between OA and VDR ApaI, BsmI, TaqI and FokI polymorphisms were conducted using allele and homozygote contrast and contrasts in the recessive and dominant models. Stratification analyses by different demographic regions (Europe vs Asian) were also performed and pooled odds ratios (ORs) were obtained using the random effects model if the results were heterogeneous. RESULTS: A total of 13 relevant studies involving OA patients (n = 2104) and controls (n = 2939) were included in the analysis. There were significant associations between VDR ApaI polymorphisms and OA in the Asian population (A vs a: OR= 1.16, 95% CI 1.02, 1.32, P = 0.025; AA vs Aa/aa: OR= 1.36, 95% CI 1.04, 1.77, P = 0.025; AA vs aa: OR= 1.35, 95% CI 1.00, 1.80, P = 0.047), but not in the whole population. There was also a statistically significant association between FokI polymorphism and OA (FF vs Ff/ff: OR= 0.65, 95% CI 0.44, 0.95, P = 0.024); however, this result was derived from only two studies. No significant associations were found between VDR TaqI and BsmI polymorphisms and OA. CONCLUSION: There are modest but statistically significant associations between VDR ApaI polymorphisms and the susceptibility of OA in the Asian population.


Assuntos
Osteoartrite/genética , Polimorfismo Genético , Receptores de Calcitriol/genética , Povo Asiático/genética , Povo Asiático/estatística & dados numéricos , Predisposição Genética para Doença , Humanos , Osteoartrite/etnologia , Viés de Publicação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...