Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Gastroenterol Hepatol ; 19(5): 1058-1060.e1, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32289545

RESUMO

Achalasia is a disorder of impaired lower esophageal sphincter (LES) relaxation and failed peristalsis traditionally characterized by manometry.1 As impaired LES relaxation is a mechanism of reduced esophagogastric junction (EGJ) opening, abnormally reduced EGJ distensibility assessed with functional luminal imaging probe (FLIP) was reported among patients with untreated achalasia.2-5 Therefore, we aimed to describe the performance characteristics of EGJ opening parameters on FLIP panometry among a large cohort of treatment-naïve achalasia patients.


Assuntos
Acalasia Esofágica , Acalasia Esofágica/diagnóstico por imagem , Esfíncter Esofágico Inferior , Junção Esofagogástrica/diagnóstico por imagem , Humanos , Manometria , Peristaltismo
2.
Clin Gastroenterol Hepatol ; 19(2): 259-268.e1, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32205217

RESUMO

BACKGROUND & AIMS: A normal esophageal response to distension on functional luminal imaging probe (FLIP) panometry during endoscopy might indicate normal esophageal motor function. We aimed to investigate the correlation of normal FLIP panometry findings with esophageal high-resolution manometry (HRM) and outcomes of discrepant patients. METHODS: We performed a retrospective study using data from a registry of patients who completed FLIP during sedated endoscopy. We identified 111 patients with normal FLIP panometry findings (mean age, 42 y; 69% female) and corresponding HRM data. A normal FLIP panometry was defined as an esophagogastric junction (EGJ) distensibility index greater than 3.0 mm2/mm Hg, an absence of repetitive retrograde contractions, and a repetitive antegrade contraction pattern that met the Rule-of-6s: ≥6 consecutive antegrade contractions of ≥6-cm in length, at a rate of 6 ± 3 contractions per minute. HRM findings were classified by the Chicago classification system version 3.0. RESULTS: HRM results were classified as normal motility in 78 patients (70%), ineffective esophageal motility in 10 patients (9%), EGJ outflow obstruction in 20 patients (18%), and 3 patients (3%) as other. In patients with EGJ outflow obstruction based on HRM, the integrated relaxation pressure normalized on adjunctive swallows in 16 of 20 patients (80%), and in 8 of 9 patients (88%) who completed a barium esophagram and had normal barium clearance. Thus, although 23 of 111 patients (21%) with normal FLIP panometry had abnormal HRM findings, these HRMs often were considered to be false-positive or equivocal results. All patients with an abnormal result from HRM were treated conservatively. CONCLUSIONS: In a retrospective cohort study, we found that patients with normal FLIP panometry results did not have a clinical impression of a major esophageal motor disorder. Normal FLIP panometry results can exclude esophageal motility disorders at the time of endoscopy, possibly negating the need for HRM in select patients.


Assuntos
Transtornos da Motilidade Esofágica , Adulto , Transtornos da Motilidade Esofágica/diagnóstico por imagem , Junção Esofagogástrica/diagnóstico por imagem , Feminino , Humanos , Masculino , Manometria , Estudos Retrospectivos
3.
Gastrointest Endosc ; 90(6): 915-923.e1, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31279625

RESUMO

BACKGROUND AND AIMS: A novel device that provides real-time depiction of functional luminal image probe (FLIP) panometry (ie, esophagogastric junction [EGJ] distensibility and distension-induced contractility) was evaluated. We aimed to compare real-time FLIP panometry interpretation at the time of sedated endoscopy with high-resolution manometry (HRM) in evaluating esophageal motility. METHODS: Forty consecutive patients (aged 24-81 years; 60% women) referred for endoscopy with a plan for future HRM from 2 centers were prospectively evaluated with real-time FLIP panometry during sedated upper endoscopy. The EGJ distensibility index and contractility profile were applied to derive a FLIP panometry classification at the time of endoscopy and again (post-hoc) using a customized program. HRM was classified according to the Chicago classification. RESULTS: Real-time FLIP panometry motility classification was abnormal in 29 patients (73%), 19 (66%) of whom had a subsequent major motility disorder on HRM. All 9 patients with an HRM diagnosis of achalasia had abnormal real-time FLIP panometry classifications. Eleven patients (33%) had normal motility on real-time FLIP panometry and 8 (73%) had a subsequent HRM without a major motility disorder. There was excellent agreement (κ = .939) between real-time and post-hoc FLIP panometry interpretation of abnormal motility. CONCLUSIONS: This prospective, multicentered study demonstrated that real-time FLIP panometry could detect abnormal esophageal motility, including achalasia, at the endoscopic encounter. Additionally, normal motility on FLIP panometry was predictive of a benign HRM. Thus, real-time FLIP panometry incorporated with endoscopy appears to provide a suitable and well-tolerated point-of-care esophageal motility assessment.


Assuntos
Transtornos da Motilidade Esofágica/patologia , Transtornos da Motilidade Esofágica/fisiopatologia , Junção Esofagogástrica/fisiologia , Esofagoscopia , Manometria/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Sistemas Computacionais , Junção Esofagogástrica/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Muscular , Estudos Prospectivos , Adulto Jovem
4.
Clin Gastroenterol Hepatol ; 17(4): 674-681.e1, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30081222

RESUMO

BACKGROUND & AIMS: Functional luminal imaging probe (FLIP) panometry provides a comprehensive evaluation of esophageal functional at the time of endoscopy, including assessment of esophageal distensibility and distension-induced esophageal contractility. However, the few and inconsistent findings from healthy individuals pose challenges to the application of FLIP to research and clinical practice. We performed FLIP panometry in asymptomatic volunteers. METHODS: We performed a prospective study of 20 asymptomatic volunteers (ages, 23-44; 14 women) who were evaluated with 16-cm FLIP positioned across the esophagogastric junction (EGJ) and distal esophagus (and in 8 subjects also repositioned at the proximal esophagus) during sedated upper endoscopy. FLIP data were analyzed with a customized program that generated FLIP panometry plots and calculated the EGJ-distensibility index (DI) and distensibility plateaus (DP) of distal and proximal esophageal body. Distension-induced esophageal contractility was also assessed. RESULTS: The median EGJ-DI was 5.8 mm2/mm Hg (interquartile range [IQR], 4.9-6.7 mm2/mm Hg); all 20 subjects had an EGJ-DI greater than 2.8 mm2/mm Hg. The median DP values from all subjects tested were 20.2 mm (IQR, 19.8-20.8 mm) at the distal body, 21.1 mm (IQR, 20.3-22.9 mm) at the proximal body, and greater than 18 mm at both locations. Repetitive antegrade contractions (RACs) were observed in all 20 subjects; in 19 of 20 (95%) subjects, the RAC pattern persisted for 10 or more consecutive antegrade contractions. CONCLUSIONS: Normal parameters of FLIP panometry are EGJ-DI greater than 2.8 mm2/mm Hg, DP greater than 18 mm, and antegrade contractions that occur in a repetitive pattern (RACs)-these can be used as normal findings for esophageal distensibility and distension-induced contractility. These values can be used in comparative studies of esophageal diseases, such as achalasia and eosinophilic esophagitis, and will facilitate application of FLIP panometry to clinical practice.


Assuntos
Elasticidade , Endoscopia , Esôfago/fisiologia , Voluntários Saudáveis , Manometria , Contração Muscular , Adulto , Esôfago/diagnóstico por imagem , Feminino , Humanos , Masculino , Estudos Prospectivos , Valores de Referência
5.
Surg Innov ; 24(1): 35-41, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27591753

RESUMO

BACKGROUND: Mini-laparoscopy, or needlescopy, is an emerging minimally invasive technique that aims to improve on standard laparoscopy in the areas of tissue trauma, pain, and cosmesis. The objective of this study was to determine if there was a difference in functionality between 2 novel mini-laparoscopic instruments when compared to standard laparoscopic tools. Differences were assessed in a simulated surgical environment. METHODS: Twenty participants (5 novices, 10 intermediate, 5 expert) were recruited for this institutional review board-approved study in a surgical simulation training center. Group A tools were assembled intracorporeally, and Group B tools were assembled extracorporeally. Using standard laparoscopic graspers, mini-laparoscopic graspers, or a combination of both, each participant performed 3 basic laparoscopic training tasks: a Peg Transfer, Rubber Band Stretch, and Tootsie Roll Unwrapping. Following each round of tasks, participants completed a survey evaluating the mini-laparoscopic graspers with respect to standard laparoscopic graspers. Data were analyzed using Kruskal-Wallis test with Dunn's test for post hoc comparisons. RESULTS: When comparing task times, both mini tools performed at the level of standard laparoscopic graspers in all participant groups. Group A tools were quicker to assemble and disassemble versus Group B tools. According to posttask surveys, all participant groups indicated that both sets of mini-laparoscopic graspers were comparable to the standard graspers. CONCLUSION: In a nonclinical setting, mini-laparoscopic instruments perform at the level of standard laparoscopic tools. Based on these results, clinical trials would be a reasonable next step in assessing feasibility and safety.


Assuntos
Laparoscópios , Laparoscopia/instrumentação , Adulto , Competência Clínica , Desenho de Equipamento , Feminino , Humanos , Masculino , Duração da Cirurgia , Treinamento por Simulação , Análise e Desempenho de Tarefas , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...