Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 24(1): 610, 2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37491199

RESUMO

BACKGROUND: Total knee replacement (TKR) is considered one of the most common elective orthopaedic procedures. The main focus of TKR is to offer patient's symptomatic relief from persistent knee pain. To achieve this it is crucial to restore joint biomechanics by performing proper bone cuts. Some surgeons favor the measured resection technique, others prefer gap balancing technique. The researchers of the presented study performed TKR using these two techniques. The aim of this study was to compare the postoperative change in joint line and posterior condylar offset after TKR with use of anatomic knee design implants between gap balancing and measured resection techniques. METHODS: Two hundred twenty-five X-rays of patients who underwent TKR performed by a single surgeon between 2020 and 2021 were analyzed. The first group of patients (101) was operated with the use of gap balancing technique and the second group (124) was operated with the use of measured resection technique. Patients included in the study were > 50 years of age, had confirmed primary knee osteoarthritis, underwent primary TKR with a PS (posterior stabilized) knee implants without patella resurfacing and had at least 15 degree flexion contracture. T-student test and U Mann-Whitney test were used in statistical analysis of results, according to the normality of distribution examined with the Shapiro-Wilk test. Post-hoc analysis was performed using the Dwass-Steel-Crichtlow-Fligner test (DSCF). RESULTS: The postoperative analysis showed a significantly elevated joint line level in the gap balancing group (-2.6 ± 4.1 vs -0.7 ± 4.8, p < 0.0005). In the gap balancing group significantly more patients had joint lines elevated > 2 mm comparing to measured resection technique. The difference between pre- and postoperative PCO (posterior condylar offset) and PCOR (posterior condylar offset ratio) results had no significant differences (100.8 ± 11.8 vs 101 ± 12.5, p > 0.05) between the groups. CONCLUSIONS: The results of the study suggest that when it comes to restoring joint line level measured resection technique seems to be superior in comparison to the gap balancing technique. What is more, results indicate measured resection is equal in terms of restoring posterior condylar offset to the gap balancing technique. TRIAL REGISTRATION: NCT04164147, date of registration: November 14, 2019.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Pessoa de Meia-Idade , Artroplastia do Joelho/métodos , Estudos de Coortes , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular
2.
Medicina (Kaunas) ; 59(5)2023 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-37241112

RESUMO

Background and Objectives: Total knee arthroplasty (TKA) is the most effective treatment method for end-stage osteoarthritis. One of the most important aspects of this surgery is adequate implant positioning, as it guarantees the desired outcome of restoring limb biomechanics. Surgical technique is being continuously improved along with hardware development. There are two novel devices designed to help establish proper femoral component rotation: soft-tissue tensor and robotic-assisted TKA (RATKA). This study compared the femoral component rotation achieved with the use of three methods: RATKA, soft tissue tensioner and the conventional measured-resection technique, all of them utilizing anatomical design prosthesis components. Materials and Methods: A total of 139 patients diagnosed with end-stage osteoarthritis underwent total knee arthroplasty between December 2020 and June 2021. After the surgery, they were divided into three groups depending on procedure technique and implant type: Persona (Zimmer Biomet) + Fuzion Balancer, RATKA + Journey II BCS or conventional TKA + Persona/Journey. Postoperatively, a computed tomography examination was performed in order to measure femoral component rotation. All three groups were compared independently during statistical analysis. Fisher's exact, Kruskal-Wallis and Dwass-Steel-Crichtlow-Fligner tests were used for particular calculations. Results: Statistically significant differences in femoral component rotation between groups were noticed. However, in terms of values other than 0° in external rotation, no significant variance was revealed. Conclusions: Additional total knee arthroplasty instruments seem to improve the outcomes of the surgery, providing better component positioning than in the conventional measured-resection technique based only on bone landmarks.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Articulação do Joelho/cirurgia , Fêmur/cirurgia , Osteoartrite do Joelho/cirurgia , Próteses e Implantes
3.
Arthroplast Today ; 12: 62-67, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34765714

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) is considered the most efficient treatment of end-stage osteoarthritis. There is an ongoing debate about proper implant designs and articulation types. One of the considered causes of unsatisfactory outcome and patients' dissatisfaction is femoral or tibial component overhanging, which can lead to chronic knee pain and restricted motion. The aim of this study is to compare radiological outcomes of TKA using an anatomic PERSONA Posterior-Stabilized (PS) knee design with its nonanatomic predecessor, the NexGen LPS. METHODS: A group of 39 patients who received the PERSONA PS system and 33 patients who received the NexGen LPS was included. PERSONA patients were matched to NexGen patients using a 0.1 propensity score threshold with priority given to exact matches. Anteroposterior, lateral, and long-leg radiographs were taken preoperatively and at 6 weeks postoperatively to perform radiological and statistical analysis. RESULTS: The PERSONA subgroup had statistically higher posterior condylar offset. There is no statistically significant difference in posterior condylar offset ratio. There were less cases of femoral notching, femoral overhang, and placing tibial baseplate in the medial overhang in the PERSONA PS subgroup than in the NexGen subgroup (each statistically significant). Occurrence of tibial underhang was not statistically significant. CONCLUSION: Radiological assessment in short-term follow-up showed excellent results for PERSONA knee design with better fit to native femur and tibia. In comparison to its predecessor, it also spares more bone tissue. As the aforementioned parameters are risk factors of lesser clinical outcomes, the PERSONA design gives high hopes for improvement of TKA satisfaction rate.

4.
J Clin Med ; 10(11)2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34064295

RESUMO

Total hip arthroplasty (THA) is currently considered the most effective treatment for end-stage hip osteoarthritis (OA). The surgery can be performed via a number of different approaches, including direct anterior (DAA; Smith-Petersen; Hueter), anterolateral (ALA; Watson-Jones), direct lateral (LA; Bauer), posterior (PA; Kocher-Langenbeck), and posterolateral (PLA). There is still a dispute over the optimal technique. The aim of this systematic review was to assess how different surgical approaches toward a THA influence the prosthesis elements' positioning. We conducted a literature search of Scopus, ScienceDirect, PubMed, Embase, and The Cochrane Library. We evaluated studies in terms of the first author's name, country, publication year, type of surgical approach being compared to the direct anterior approach, any significant differences at baseline, sample size, and radiographic analysis. A subanalysis of each approach in comparison to the DAA revealed differences in terms of all analyzed implant positioning radiographic parameters. There is still an insufficient number of randomized controlled studies that include radiological analyses comparing THRs (total hip replacements) performed using DAA with other approaches. Implant placement is a crucial step during a THR and surgeons must be aware that the approach they use might impact their judgment on angles and spaces inside the joint and thus alter the implant positioning.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...