Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Langmuir ; 38(46): 14249-14260, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-36368024

RESUMO

An efficient superhydrophobic concentrator is developed using a hierarchical superhydrophobic surface on which the evaporation of a sessile droplet (6 µL) drives the nonvolatile elements it contains on a predefined micrometric analytical surface (pedestal of 80 µm diameter). This hierarchical silicon surface exhibits a surface texture made of etched nanopillars and consists of micropillars and guiding lines, arranged in radial symmetry around the central pedestal. The guiding lines ensure the overall convergence of the sessile droplet toward the central pedestal during evaporation. The nanopillar texturing induced a delay in the Cassie-Baxter to Wenzel regime transition, until the edge of the droplet reaches the periphery of the pedestal. Experiments performed with polymer microparticles suspended in ultrapure water or with DNA molecules solubilized in ultrapure water at sub-fM concentrations demonstrated that the totality of the nonvolatile elements in the liquid microvolume is delivered on or close to the pedestal area, in a very reproducible manner. The very high concentration capacity of the device enabled the discrimination of the degree of purity of ultrapure water samples from different origins. The concentrator also turned out to be functional for raw water samples, opening possible applications to environmental analysis.


Assuntos
Silício , Água , Água/química , Interações Hidrofóbicas e Hidrofílicas , Propriedades de Superfície , Silício/química , Polímeros/química
2.
Opt Express ; 26(20): 25952-25961, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30469689

RESUMO

Liquid crystal (LC) microcells monolithically integrated on the surface of InGaAs based photodiodes (PDs) are demonstrated. These LC microcells acting as tunable Fabry-Perot filters exhibit a wavelength tunability of more than 100 nm around 1550 nm with less than 10V applied voltage. Using a tunable laser operating in the S and C bands, photocurrent measurements are performed. On a 70 nm tuning range covered with a driving voltage lower than 7V, the average sensitivity for the PD is 0.4 A/W and the spectral linewidth of the LC filter remains constant, showing a FWHM of 1.5 nm. Finally, the emission spectrum from an Er-doped fiber is acquired by using this tunable PD as a micro-spectrometer.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...