Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagn Interv Imaging ; 105(1): 26-32, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37482455

RESUMO

PURPOSE: The purpose of this study was to evaluate the ability to depict in vivo bone vascularization using ultra-high-resolution (UHR) computed tomography (CT) with deep learning reconstruction (DLR) and hybrid iterative reconstruction algorithm, compared to simulated conventional CT, using osteoid osteoma as a model. MATERIALS AND METHODS: Patients with histopathologically proven cortical osteoid osteoma who underwent UHR-CT between October 2019 and October 2022 were retrospectively included. Images were acquired with a 1024 × 1024 matrix and reconstructed with DLR and hybrid iterative reconstruction algorithm. To simulate conventional CT, images with a 512 × 512 matrix were also reconstructed. Two radiologists (R1, R2) independently evaluated the number of blood vessels entering the nidus and crossing the bone cortex, as well as vessel identification and image quality with a 5-point scale. Standard deviation (SD) of attenuation in the adjacent muscle and that of air were used as image noise and recorded. RESULTS: Thirteen patients with 13 osteoid osteomas were included. There were 11 men and two women with a mean age of 21.8 ± 9.1 (SD) years. For both readers, UHR-CT with DLR depicted more nidus vessels (11.5 ± 4.3 [SD] (R1) and 11.9 ± 4.6 [SD] (R2)) and cortical vessels (4 ± 3.8 [SD] and 4.3 ± 4.1 [SD], respectively) than UHR-CT with hybrid iterative reconstruction (10.5 ± 4.3 [SD] and 10.4 ± 4.6 [SD], and 4.1 ± 3.8 [SD] and 4.3 ± 3.8 [SD], respectively) and simulated conventional CT (5.3 ± 2.2 [SD] and 6.4 ± 2.5 [SD], 2 ± 1.2 [SD] and 2.4 ± 1.6 [SD], respectively) (P < 0.05). UHR-CT with DLR provided less image noise than simulated conventional CT and UHR-CT with hybrid iterative reconstruction (P < 0.05). UHR-CT with DLR received the greatest score and simulated conventional CT the lowest score for vessel identification and image quality. CONCLUSION: UHR-CT with DLR shows less noise than UHR-CT with hybrid iterative reconstruction and significantly improves cortical bone vascularization depiction compared to simulated conventional CT.


Assuntos
Neoplasias Ósseas , Aprendizado Profundo , Osteoma Osteoide , Masculino , Humanos , Feminino , Criança , Adolescente , Adulto Jovem , Adulto , Osteoma Osteoide/diagnóstico por imagem , Osteoma Osteoide/cirurgia , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Osso Cortical/diagnóstico por imagem , Algoritmos , Neoplasias Ósseas/diagnóstico por imagem
2.
Eur Radiol ; 34(1): 686-691, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37566269

RESUMO

OBJECTIVES: Evaluate the prevalence of radiological anomalies on orthopantomograms (OPT) performed as part of forensic age estimation in unaccompanied minors. METHODS: This is a retrospective study conducted on 208 OPT examinations requested by a magistrate. These OPTs were interpreted independently by two readers to establish the number of missing teeth (MT), presence of dental fillings (DF), and dental anomalies (DA). The presence of radiolucent (RL), radiopaque, and mixed lesions was also assessed. RESULTS: Most radiologic anomalies were RL, detected on 41% and 39% of the subjects evaluated for R1 and R2, respectively, with a mean of 1.3 ± 2.4 (1-16) and 1.1 ± 2 (1-13) RL lesions per subject. Among the RL identified, the majority were dental (70% for R1 and 65% for R2), all of which had a suspected infectious origin. Among readers, 43% and 41% of the subjects evaluated presented MT, 21% and 15% presented DF, and 22% and 20% presented DA for R1 and R2, respectively. The inter- and intra-observer reproducibility for OPT classification was considered excellent (Kappa = 0.84, 95% CI 0.78-0.90, and Kappa = 0, 95, 95% CI 0.86-0.99). DISCUSSION: There was a non-negligible prevalence of radiological anomalies in OPT studies performed for forensic age estimation. Most of these lesions were suspected to be infectious in origin, potentially requiring medical care. This constitutes an ethical dilemma inherent in the judicial expertise injunction requiring a limited specific response. CLINICAL RELEVANCE STATEMENT: This study highlights a non-negligible prevalence of supposedly infectious radiological abnormalities. The restricted possibility for the legal expert to declare these abnormalities raises ethical and medical questions. KEY POINTS: • Orthopantomograms can be performed as part of forensic age estimation. • Results indicate the majority of radiological anomalies detected on OPTs were of suspected infectious origin. • These findings give rise to ethical and medical questions about the way in which these forensic examinations are carried out.


Assuntos
Determinação da Idade pelos Dentes , Refugiados , Humanos , Determinação da Idade pelos Dentes/métodos , Prevalência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Radiografia Panorâmica , Odontologia Legal
3.
Radiology ; 308(3): e230193, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37698480

RESUMO

Background Initial imaging work-up using radiography and CT arthrography sometimes can be insufficient to identify a scapholunate (SL) instability (SLI) in patients suspected of having SL ligament tears. Purpose To determine the diagnostic performance of four-dimensional (4D) CT in the identification of SLI and apply the findings to patients suspected of having SLI and with inconclusive findings on radiographs and CT arthrograms. Materials and Methods This prospective single-center study enrolled participants suspected of having SLI (recent trauma, dorsal pain, positive Watson test results, decreased grip strength) between March 2015 and March 2020. Participants with wrist fractures, substantial joint stiffness, or history of wrist surgery were excluded. Each participant underwent radiography, CT arthrography, and 4D CT on the same day. Participants were divided into three groups: those with no SLI, those with SLI, and those with inconclusive results. SL gap and radioscaphoid and lunocapitate angle were measured using semiautomatic quantitative analysis of 4D CT images by two independent readers. Receiver operating characteristic curves were used to evaluate the diagnostic performance of 4D CT. Thresholds were determined with the Youden index and were applied to the inconclusive group. Results Of the 150 included participants (mean age, 41 years ± 14 [SD]; 102 male, 48 female), there were 63 with no SLI, 48 with SLI, and 39 with inconclusive results. The maximum value and range of SL gap measurements on 4D CT scans showed high sensitivity (83% [40 of 48] and 90% [43 of 48], respectively) and high specificity (95% [59 of 62] and 81% [50 of 62], respectively) in the identification of SLI. At least one of these parameters was abnormal on 4D CT scans in 17 of 39 (44%) participants in the inconclusive group, and 10 of 17 (59%) participants had confirmed SLI. In the 22 participants in the inconclusive group with no indication of SLI at 4D CT, follow-up showed no evidence of SLI in 10 (45%) and enabled confirmation of SLI via arthroscopy in three (14%). Conclusion Scapholunate gap measurements on kinematic 4D CT scans enabled correct identification of SLI in 59% of participants with inconclusive results on conventional images. ClinicalTrials.gov registration no. NCT02401568 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Demehri and Ibad in this issue.


Assuntos
Tomografia Computadorizada Quadridimensional , Fraturas Ósseas , Humanos , Feminino , Masculino , Adulto , Estudos Prospectivos , Artroscopia , Ligamentos Articulares
4.
Int J Legal Med ; 134(1): 339-346, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31734725

RESUMO

OBJECTIVES: The main objective of this study was to evaluate the diagnostic performance of the OpenRib software against the gold standard of autopsy in the detection of rib fractures. The secondary objective was to measure inter-rater agreement between each radiological reader. MATERIALS AND METHODS: Thirty-six subjects who underwent postmortem CT and autopsy were included in this study. Rib fractures were first assessed during the autopsy by carefully dissecting and examining each rib. They were also independently evaluated by three readers using OpenRib software. This software produces from postmortem CT images a reformat of the rib cage and a display of all ribs in a single plane. Each reader was asked to determine if the rib was fractured and, if so, whether the fracture was single or multiple. RESULTS: After exclusions, 649 ribs were included in the statistical analysis. The two readers with a similar level of experience showed a satisfactory inter-rater agreement and a sensitivity of 0.73 and 0.83 with a specificity of 0.95 and 0.91. However, the experienced reader diagnosed significantly more fractures than the autopsy and the other two readers (p < 0.001). CONCLUSION: The use of automatic rib unfolding software in postmortem CT allows an efficient and accurate assessment of rib fractures and enables the diagnosis of fractures that cannot be detected during a standard autopsy. For now, this method seems to be the simplest that can be routinely performed; however, it requires training time in order to be sufficiently effective.


Assuntos
Autopsia/normas , Fraturas das Costelas/diagnóstico por imagem , Software , Tomografia Computadorizada por Raios X , Humanos , Variações Dependentes do Observador , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...