1.
Sensors (Basel) ; 23(23)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38067922

RESUMO

Cervical degenerative disc diseases such as myelopathy and radiculopathy often require conventional treatments like artificial cervical disc replacement or anterior cervical discectomy and fusion (ACDF). When designing a medical device, like the stand-alone cage, there are many design inputs to consider. However, the precise biomechanics of the force between the vertebrae and implanted devices under certain conditions require further investigation. In this study, a new method was developed to evaluate the pressure between the vertebrae and implanted devices by embedding a sensor array into a 3D-printed C2-C3 cervical spine. The 3D-printed cervical spine model was subjected to a range of axial loads while under flexion, extension, bending and compression conditions. Cables were used for the application of a preload and a robotic arm was used to recreate the natural spine motions (flexion, extension, and bending). To verify and predict the total pressure between the vertebrae and the implanted devices, a 3D finite element (FE) numerical mathematical model was developed. A preload was represented by applying 22 N of force on each of the anterior tubercles for the C2 vertebra. The results of this study suggest that the sensor is useful in identifying static pressure. The pressure with the robot arm was verified from the FE results under all conditions. This study indicates that the sensor array has promising potential to reduce the trial and error with implants for various surgical procedures, including multi-level artificial cervical disk replacement and ACDF, which may help clinicians to reduce pain, suffering, and costly follow-up procedures.


Assuntos
Degeneração do Disco Intervertebral , Fusão Vertebral , Humanos , Fusão Vertebral/métodos , Vértebras Cervicais/cirurgia , Degeneração do Disco Intervertebral/cirurgia , Discotomia/métodos , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Impressão Tridimensional
2.
Front Bioeng Biotechnol ; 11: 1237702, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37790254

RESUMO

The study aimed to investigate the impact of posterior element and ligament removal on the maximum von Mises stress, and maximum shear stress of the eight-layer annulus for treating stenosis at the L3-L4 and L4-L5 levels in the lumbar spine. Previous studies have indicated that laminectomy alone can result in segmental instability unless fusion is performed. However, no direct correlations have been established regarding the impact of posterior and ligament removal. To address this gap, four models were developed: Model 1 represented the intact L2-L5 model, while model 2 involved a unilateral laminotomy involving the removal of a section of the L4 inferior lamina and 50% of the ligament flavum between L4 and L5. Model 3 consisted of a complete laminectomy, which included the removal of the spinous process and lamina of L4, as well as the relevant connecting ligaments between L3-L4 and L4-L5 (ligament flavum, interspinous ligament, supraspinous ligament). In the fourth model, a complete laminectomy with 50% facetectomy was conducted. This involved the same removals as in model 3, along with a 50% removal of the inferior/superior facets of L4 and a 50% removal of the facet capsular ligaments between L3-L4 and L4-L5. The results indicated a significant change in the range of motion (ROM) at the L3-L4 and L4-L5 levels during flexion and torque situations, but no significant change during extension and bending simulation. The ROM increased by 10% from model 1 and 2 to model 3, and by 20% to model 4 during flexion simulation. The maximum shear stress and maximum von-Mises stress of the annulus and nucleus at the L3-L4 levels exhibited the greatest increase during flexion. In all eight layers of the annulus, there was an observed increase in both the maximum shear stress and maximum von-Mises stress from model 1&2 to model 3 and model 4, with the highest rate of increase noted in layers 7&8. These findings suggest that graded posterior element and ligament removal have a notable impact on stress distribution and range of motion in the lumbar spine, particularly during flexion.

3.
Asian Spine J ; 17(5): 949-963, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37408489

RESUMO

The cervical spine poses many complex challenges that require complex solutions. Anterior cervical discectomy and fusion (ACDF) has been one such technique often employed to address such issues. In order to address the problems with ACDF and assess the modifications that have been made to the technique over time, finite element analyses (FEA) have proven to be an effective tool. The variations of cervical spine FEA models that have been produced over the past couple of decades, particularly more recent representations of more complex geometries, have not yet been identified and characterized in any literature. Our objective was to present material property models and cervical spine models for various simulation purposes. The outlining and refinement of the FEA process will yield more reliable outcomes and provide a stable basis for the modeling protocols of the cervical spine.

4.
Bioengineering (Basel) ; 11(1)2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38247901

RESUMO

Over the past few decades, there has been a growing popularity in utilizing finite element analysis to study the spine. However, most current studies tend to use one specimen for their models. This research aimed to validate multiple finite element models by comparing them with data from in vivo experiments and other existing finite element studies. Additionally, this study sought to analyze the data based on the gender and age of the specimens. For this study, eight lumbar spine (L2-L5) finite element models were developed. These models were then subjected to finite element analysis to simulate the six fundamental motions. CT scans were obtained from a total of eight individuals, four males and four females, ranging in age from forty-four (44) to seventy-three (73) years old. The CT scans were preprocessed and used to construct finite element models that accurately emulated the motions of flexion, extension, lateral bending, and axial rotation. Preloads and moments were applied to the models to replicate physiological loading conditions. This study focused on analyzing various parameters such as vertebral rotation, facet forces, and intradiscal pressure in all loading directions. The obtained data were then compared with the results of other finite element analyses and in vivo experimental measurements found in the existing literature to ensure their validity. This study successfully validated the intervertebral rotation, intradiscal pressure, and facet force results by comparing them with previous research findings. Notably, this study concluded that gender did not have a significant impact on the results. However, the results did highlight the importance of age as a critical variable when modeling the lumbar spine.

5.
Asian Spine J ; 16(5): 615-624, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35263829

RESUMO

STUDY DESIGN: This study compares four cervical endplate removal procedures, validated by finite element models. PURPOSE: To characterize the effect of biomechanical strength and increased contact area on the maximum von Mises stress, migration, and subsidence between the cancellous bone, endplate, and implanted cage. OVERVIEW OF LITERATURE: Anterior cervical discectomy and fusion (ACDF) has been widely used for treating patients with degenerative spondylosis. However, no direct correlations have been drawn that incorporate the impact of the contact area between the cage and the vertebra/endplate. METHODS: Model 1 (M1) was an intact C2C6 model with a 0.5 mm endplate. In model 2 (M2), a cage was implanted after removal of the C4-C5 and C5-C6 discs with preservation of the osseous endplate. In model 3 (M3), 1 mm of the osseous endplate was removed at the upper endplate. Model 4 (M4) resembles M3, except that 3 mm of the osseous endplate was removed. RESULTS: The range of motion (ROM) at C2C6 in the M2-M4 models was reduced by at least 9º compared to the M1 model. The von Mises stress results in the C2C3 and C3C4 interbody discs were significantly smaller in the M1 model and slightly increased in the M2-M3 and M3-M4 models. Migration and subsidence decreased from the M2-M3 model, whereas further endplate removal increased the migration and subsidence as shown in the transition from M3 to M4. CONCLUSIONS: The M3 model had the least subsidence and migration. The ROM was higher in the M3 model than the M2 and M4 models. Endplate preparation created small stress differences in the healthy intervertebral discs above the ACDF site. A 1 mm embedding depth created the best balance of mechanical strength and contact area, resulting in the most favorable stability of the construct.

6.
Spine J ; 21(5): 874-882, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33460810

RESUMO

BACKGROUND CONTEXT: Anterior cervical discectomy and fusion (ACDF) is widely used to treat patients with spinal disorders, where the cage is a critical component to achieve satisfactory fusion results. However, it is still not clear whether a cage with screws or without screws will be the best choice for long-term fusion as the micromotion (sliding distance) and subsidence (penetration) of the cage still take place repeatedly. PURPOSE: This study aims to examine the effect of cage-screws on the biomechanical characteristics of the human spine, implanted cage, and associate hardware by comparing the micromotion and subsidence. STUDY DESIGN: A finite element (FE) analysis study. METHODS: A FE model of a C3-C5 cervical spine with ACDF was developed. The spinal segment was modeled with the removal of the anterior longitudinal ligament (ALL), posterior longitudinal ligament (PLL), and discectomy was then implanted with a cage-screw system. Three models were analyzed: the first was the original spine (S1 model), the second, S2, was implanted with cages and anterior plating, and the third, S3, was implanted with a cage-screw system in addition to the anterior plate. All investigations were under 1 N•m in flexion, extension, lateral bending, and axial rotation situations. RESULTS: Finite element analysis (FEA) demonstrated that range of motion (ROM) at C3-C4 in the S2 model was significantly reduced more than that in the S3 model, while the ROM at both C4-C5 in the S3 model was reduced more than that in the S2 model in all simulations. The ROM at C3-C5 in the S1 model was reduced by over 5° in the S2 and S3 models in all loading conditions. The micromotion and subsidence at all contacts of C3-C5 in the S3 model were lower than that in the S2 model in all flexion, extension, bending, and axial simulations. The subsidence and micromotion could be seen in the barrier area of the S2 model, while they occurred near the edge of the screw in the S3 model. CONCLUSIONS: These results showed that the cage-screw and anterior plating combination has promising potential to reduce the risk of micromotion and subsidence of implanted cages in two or more level ACDFs. CLINICAL SIGNIFICANCE: The use of double segmental fixation with cage-screw anterior plating combination constructs may increase the stiffness of the construct and reduce the incidence of clinical and radiographic pseudarthrosis following multilevel ACDF, which in turn, could decrease the need for revision surgeries or supplemental posterior fixation.


Assuntos
Fusão Vertebral , Fenômenos Biomecânicos , Parafusos Ósseos , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Discotomia , Análise de Elementos Finitos , Humanos , Amplitude de Movimento Articular
7.
Cancer Control ; 22(3): 352-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26351892

RESUMO

BACKGROUND: Advances in technology have pushed the boundaries of neurosurgery. Surgeons play a major role in the neurosurgical field, but robotic systems challenge the current status quo. Robotic-assisted surgery has revolutionized several surgical fields, yet robotic-assisted neurosurgery is limited by available technology. METHODS: The literature on the current robotic systems in neurosurgery and the challenges and compromises of robotic design are reviewed and discussed. RESULTS: Several robotic systems are currently in use, but the application of these systems is limited in the field of neurosurgery. Most robotic systems are suited to assist in stereotactic procedures. Current research and development teams focus on robotic-assisted microsurgery and minimally invasive surgery. The tasks of miniaturizing the current tools and maximizing control challenge manufacturers and hinder progress. Furthermore, loss of haptic feedback, proprioception, and visualization increase the time it takes for users to master robotic systems. CONCLUSIONS: Robotic-assisted surgery is a promising field in neurosurgery, but improvements and breakthroughs in minimally invasive and endoscopic robotic-assisted surgical systems must occur before robotic assistance becomes commonplace in the neurosurgical field.


Assuntos
Procedimentos Neurocirúrgicos/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Humanos , Procedimentos Neurocirúrgicos/tendências , Procedimentos Cirúrgicos Robóticos/tendências
8.
Biomed Res Int ; 2015: 506181, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25785272

RESUMO

In vitro biomechanical investigations have become a routinely employed technique to explore new lumbar instrumentation. One of the most important advantages of such investigations is the low risk present when compared to clinical trials. However, the best use of any experimental data can be made when standard testing protocols are adopted by investigators, thus allowing comparisons among studies. Experimental variables, such as the length of the specimen, operative level, type of loading (e.g., dynamic versus quasistatic), magnitude, and rate of load applied, are among the most common variables controlled during spinal biomechanical testing. Although important efforts have been made to standardize these protocols, high variability can be found in the current literature. The aim of this investigation was to conduct a systematic review of the literature to identify the current trends in the protocols reported for the evaluation of new lumbar spinal implants under laboratory setting.


Assuntos
Fenômenos Biomecânicos/fisiologia , Protocolos Clínicos/normas , Vértebras Lombares/fisiologia , Vértebras Lombares/cirurgia , Próteses e Implantes/normas , Animais , Humanos , Laboratórios/normas , Fusão Vertebral/métodos , Fusão Vertebral/normas , Revisões Sistemáticas como Assunto
9.
Biomed Res Int ; 2015: 318405, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25705655

RESUMO

Many successful attempts to increase pullout strength of pedicle screws in osteoporotic bone have been accompanied with an increased risk of catastrophic damage to the patient. To avoid this, a single-armed expansive pedicle screw was designed to increase fixation strength while controlling postfailure damage away from the nerves surrounding the pedicle. The screw was then subsequently tested in two severely osteoporotic models: one representing trabecular bone (with and without the presence of polymethylmethacrylate) and the other representing a combination of trabecular and cortical bone. Maximum pullout strength, stiffness, energy to failure, energy to removal, and size of the resulting block damage were statistically compared among conditions. While expandable pedicle screws produced maximum pullout forces less than or comparable to standard screws, they required a higher amount of energy to be fully removed from both models. Furthermore, damage to the cortical layer in the composite test blocks was smaller in all measured directions for tests involving expandable pedicle screws than those involving standard pedicle screws. This indicates that while initial fixation may not differ in the presence of cortical bone, the expandable pedicle screw offers an increased level of postfailure stability and safety to patients awaiting revision surgery.


Assuntos
Osso e Ossos/cirurgia , Osteoporose/cirurgia , Parafusos Pediculares , Fenômenos Biomecânicos , Osso e Ossos/fisiopatologia , Humanos , Teste de Materiais , Osteoporose/fisiopatologia , Polimetil Metacrilato/química
10.
Clin Biomech (Bristol, Avon) ; 30(2): 205-10, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25577548

RESUMO

BACKGROUND: This investigation compares an interspinous fusion device with posterior pedicle screw system in a lateral lumbar interbody lumbar fusion. METHODS: We biomechanically tested six cadaveric lumbar segments (L1-L2) under an axial preload of 50N and torque of 5Nm in flexion-extension, lateral bending and axial rotation directions. We quantified range of motion, neutral zone/elastic zone stiffness in the following conditions: intact, lateral discectomy, lateral cage, cage with interspinous fusion, and cage with pedicle screws. FINDINGS: A complete lateral discectomy and annulectomy increased motion in all directions compared to all other conditions. The lateral cage reduced motion in lateral bending and flexion/extension with respect to the intact and discectomy conditions, but had minimal effect on extension stiffness. Posterior instrumentation reduced motion, excluding interspinous augmentation in axial rotation with respect to the cage condition. Interspinous fusion significantly increased flexion and extension stiffness, while pedicle screws increased flexion/extension and lateral bending stiffness, with respect to the cage condition. Both posterior augmentations performed equivalently throughout the tests except in lateral bending stiffness where pedicle screws were stiffer in the neutral zone. INTERPRETATION: A lateral discectomy and annulectomy generates immediate instability. Stand-alone lateral cages restore a limited amount of immediate stability, but posterior supplemental fixation increases stability. Both augmentations are similar in a single level lateral fusion in-vitro model, but pedicle screws are more equipped for coronal stability. An interspinous fusion is a less invasive alternative than pedicle screws and is potentially a conservative option for various interbody cage scenarios.


Assuntos
Fixadores Internos , Vértebras Lombares/fisiologia , Vértebras Lombares/cirurgia , Parafusos Pediculares , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Fenômenos Biomecânicos , Cadáver , Discotomia/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Rotação , Torque
11.
Biomed Res Int ; 2014: 748393, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24724097

RESUMO

Osteoporosis is a medical condition affecting men and women of different age groups and populations. The compromised bone quality caused by this disease represents an important challenge when a surgical procedure (e.g., spinal fusion) is needed after failure of conservative treatments. Different pedicle screw designs and instrumentation techniques have been explored to enhance spinal device fixation in bone of compromised quality. These include alterations of screw thread design, optimization of pilot hole size for non-self-tapping screws, modification of the implant's trajectory, and bone cement augmentation. While the true benefits and limitations of any procedure may not be realized until they are observed in a clinical setting, axial pullout tests, due in large part to their reproducibility and ease of execution, are commonly used to estimate the device's effectiveness by quantifying the change in force required to remove the screw from the body. The objective of this investigation is to provide an overview of the different pedicle screw designs and the associated surgical techniques either currently utilized or proposed to improve pullout strength in osteoporotic patients. Mechanical comparisons as well as potential advantages and disadvantages of each consideration are provided herein.


Assuntos
Parafusos Ósseos , Osteoporose/cirurgia , Desenho de Prótese , Coluna Vertebral/cirurgia , Animais , Feminino , Humanos , Masculino
12.
Cancer Control ; 21(2): 144-50, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24667401

RESUMO

BACKGROUND: Often the spine is afflicted from primary or metastatic neoplastic disease, which can lead to instability. Instability can cause deformity, pain, and spinal cord compression and is an indication for surgery. Although overt instability is uniformly agreed upon, it is sometimes difficult for specialists to agree on subtle degrees of instability due to lack of objective criteria. METHODS: In this article, treatment options and the spine instability neoplastic system are discussed and the neoplastic instability literature is reviewed. RESULTS: The Spinal Instability Neoplastic Score helps specialists determine whether instability is present and when surgery may be indicated. However, other parameters such as spinal cord compression and extent of disease dictate whether surgery is the most appropriate option. A wide range of fusion techniques exists, each one tailored to the location of the lesion and goals for surgery. CONCLUSIONS: To optimize results, expert knowledge on the techniques and patient selection is of importance. Furthermore, a multidisciplinary approach is required because treatment of neoplastic disease is multimodal.


Assuntos
Neoplasias da Coluna Vertebral/fisiopatologia , Neoplasias da Coluna Vertebral/terapia , Fenômenos Biomecânicos , Humanos , Neoplasias da Coluna Vertebral/cirurgia
13.
J Neurosurg Spine ; 20(4): 387-95, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24484306

RESUMO

OBJECT: Through in vitro biomechanical testing, the authors compared the performance of a vertically expandable lateral lumbar interbody cage (EC) under two different torque-controlled expansions (1.5 and 3.0 Nm) and with respect to an equivalent lateral lumbar static cage (SC) with and without pedicle screw fixation. METHODS: Eleven cadaveric human L2-3 segments were evaluated under the following conditions: 1) intact; 2) discectomy; 3) EC under 1.50 Nm of torque expansion (EC-1.5Nm); 4) EC under 3.00 Nm of torque expansion (EC-3.0Nm); 5) SC; and 6) SC with a bilateral pedicle screw system (SC+BPSS). Load-displacement behavior was evaluated for each condition using a combination of 100 N of axial preload and 7.5 Nm of torque in flexion and extension (FE), lateral bending (LB), and axial rotation (AR). Range of motion (ROM), neutral zone stiffness (NZS), and elastic zone stiffness (EZS) were statistically compared among conditions using post hoc Wilcoxon signed-rank comparisons after Friedman tests, with a significance level of 0.05. Additionally, any cage height difference between interbody devices was evaluated. When radiographic subsidence was observed, the specimen's data were not considered for the analysis. RESULTS: The final cage height in the EC-1.5Nm condition (12.1 ± 0.9 mm) was smaller (p < 0.001) than that in the EC-3.0Nm (13.9 ± 1.1 mm) and SC (13.4 ± 0.8 mm) conditions. All instrumentation reduced (p < 0.01) ROM with respect to the injury and increased (p ≤ 0.01) NZS in flexion, extension, and LB as well as EZS in flexion, LB, and AR. When comparing the torque expansions, the EC-3.0Nm condition had smaller (p < 0.01) FE and AR ROM and greater (p ≤ 0.04) flexion NZS, extension EZS, and AR EZS. The SC condition performed equivalently (p ≥ 0.10) to both EC conditions in terms of ROM, NZS, and EZS, except for EZS in AR, in which a marginal (p = 0.05) difference was observed with respect to the EC-3.0Nm condition. The SC+BPSS was the most rigid construct in terms of ROM and stiffness, except for 1) LB ROM, in which it was comparable (p = 0.08) with that of the EC-1.5Nm condition; 2) AR NZS, in which it was comparable (p > 0.66, Friedman test) with that of all other constructs; and 3) AR EZS, in which it was comparable with that of the EC-1.5Nm (p = 0.56) and SC (p = 0.08) conditions. CONCLUSIONS: A 3.0-Nm torque expansion of a lateral interbody cage provides greater immediate stability in FE and AR than a 1.5-Nm torque expansion. Moreover, the expandable device provides stability comparable with that of an equivalent (in size, shape, and bone-interface material) SC. Specifically, the SC+BPSS construct was the most stable in FE motion. Even though an EC may seem a better option given the minimal tissue disruption during its implantation, there may be a greater chance of endplate collapse by over-distracting the disc space because of the minimal haptic feedback from the expansion.


Assuntos
Fixadores Internos , Vértebras Lombares/cirurgia , Amplitude de Movimento Articular/fisiologia , Fusão Vertebral/instrumentação , Idoso , Fenômenos Biomecânicos/fisiologia , Parafusos Ósseos , Feminino , Humanos , Vértebras Lombares/fisiologia , Masculino , Pessoa de Meia-Idade , Rotação , Fusão Vertebral/métodos
14.
J Neurosurg Spine ; 20(2): 209-19, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24286528

RESUMO

OBJECT: In this paper the authors evaluate through in vitro biomechanical testing the performance of an interspinous fusion device as a stand-alone device, after lumbar decompression surgery, and as supplemental fixation to expandable cages in a posterior lumbar interbody fusion (PLIF) construct. METHODS: Nine L3-4 human cadaveric spines were biomechanically tested under the following conditions: 1) intact/control; 2) L3-4 left hemilaminotomy with partial discectomy (injury); 3) interspinous spacer (ISS); 4) bilateral pedicle screw system (BPSS); 5) bilateral hemilaminectomy, discectomy, and expandable posterior interbody cages with ISS (PLIF-ISS); and 6) PLIF-BPSS. Each test consisted of 100 N of axial preload with ± 7.5 Nm of torque in flexion-extension, right/left lateral bending, and right/left axial rotation. Significant changes in range of motion (ROM), neutral zone stiffness (NZS), elastic zone stiffness (EZS), and energy loss (EL) were explored among conditions using nonparametric Friedman test and Wilcoxon signed-rank comparisons (p ≤ 0.05). RESULTS: The injury increased ROM in flexion (p = 0.01), left bending (p = 0.03), and right/left rotation (p < 0.01) and also decreased NZS in flexion (p = 0.01) and extension (p < 0.01). Both the ISS and BPSS reduced flexion-extension ROM and increased flexion-extension stiffness (NZS and EZS) with respect to the injury and intact conditions (p < 0.05), but the ISS condition provided greater resistance than BPSS in extension for ROM, NZS, and EZS (p < 0.01). The BPSS increased the rigidity (ROM, NZS, and EZS) of the intact model in lateral bending and axial rotation (p ≤ 0.01), except in EZS for left rotation (p = 0.23, Friedman test). The incorporation of posterior cages marginally increased (p = 0.05) the EZS of the BPSS construct in flexion but these interbody devices provided significant stability to the ISS construct in lateral bending and axial rotation for ROM (p = 0.02), in lateral bending for NZS (p = 0.02), and in flexion/axial rotation for EZS (p ≤ 0.03); however, both PLIF constructs demonstrated equivalent ROM and stiffness (p ≥ 0.16), except in lateral bending where the PLIF-BPSS was more stable (p = 0.02). In terms of EL, the injury increased EL in flexion-extension (p = 0.02), the ISS increased EL for lateral bending and axial rotation (p ≤ 0.03), and the BPSS decreased EL in lateral bending (p = 0.02), with respect to the intact condition. The PLIF-ISS decreased lateral bending EL with respect to the ISS condition (p = 0.02), but not enough to be smaller or, at least, equivalent, to that of the PLIF-BPSS construct (p = 0.02). CONCLUSIONS: The ISS may be a suitable device to provide immediate flexion-extension balance after a unilateral laminotomy, but the BPSS provides greater immediate stability in lateral bending and axial rotation motions. Both PLIF constructs performed equivalently in flexion-extension and axial rotation, but the PLIF-BPSS construct is more resistant to lateral bending motions. Further biomechanical and clinical evidence is required to strongly support the recommendation of a stand-alone interspinous fusion device or as supplemental fixation to expandable posterior interbody cages.


Assuntos
Vértebras Lombares/cirurgia , Amplitude de Movimento Articular/fisiologia , Fusão Vertebral/métodos , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos/fisiologia , Parafusos Ósseos , Humanos , Vértebras Lombares/fisiologia , Masculino , Pessoa de Meia-Idade , Fusão Vertebral/instrumentação
15.
Clin Biomech (Bristol, Avon) ; 29(1): 21-5, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24239024

RESUMO

BACKGROUND: Common fusion techniques for cervical degenerative diseases include two-level anterior discectomy and fusion and one-level corpectomy and fusion. The aim of the study was to compare via in-vitro biomechanical testing the effects of a two-level anterior discectomy and fusion and a one-level corpectomy and fusion, with anterior plate reconstruction. METHODS: Seven fresh frozen human cadaveric spines (C3-T1) were dissected from posterior musculature, preserving the integrity of ligaments and intervertebral discs. Initial biomechanical testing consisted of no-axial preload and 2Nm in flexion-extension, lateral bending and axial rotation. Thereafter, discectomies were performed at C4-5 and C5-6 levels, then two interbody cages and an anterior C4-C5-C6 plate was implanted. The flexibility tests were repeated and followed by C5 corpectomy and C4-C6 plate reconstruction. Biomechanical testing was performed again and statistical comparisons among the means of range of motion and axial rotation energy loss were investigated. FINDINGS: The two-level cage-plate construct had significantly lower range of motion than the one-level corpectomy-plate construct (P≤0.03). Axial rotation energy loss was significantly (P≤0.03) greater for the corpectomy-plate construct than for the two-level cage-plate construct and the intact condition. INTERPRETATION: A two-level cage-plate construct provides greater stability in flexion, extension and lateral bending motions when compared to a one-level corpectomy-plate construct. A two-level cage-plate is more likely to maintain axial balance by reducing the energy lost in axial rotation.


Assuntos
Placas Ósseas , Vértebras Cervicais/cirurgia , Discotomia/métodos , Amplitude de Movimento Articular/fisiologia , Fusão Vertebral/métodos , Fenômenos Biomecânicos/fisiologia , Biofísica/instrumentação , Cadáver , Discotomia/instrumentação , Feminino , Humanos , Fixadores Internos , Disco Intervertebral , Masculino , Pessoa de Meia-Idade , Rotação
16.
Spine J ; 14(4): 705-13, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24268392

RESUMO

BACKGROUND CONTEXT: The bilateral pedicle screw system (BPSS) is currently the "gold standard" fusion technique for spinal instability. A new stabilization system that provides the same level of stability through a less invasive procedure will have a high impact on clinical practice. A new transdiscal screw system is investigated as a promising minimally invasive device. PURPOSE: To evaluate the feasibility of a novel transdiscal screw in spinal fixation as an alternative to BPSS, with and without an interbody cage, in non-spondylolisthesis cases. STUDY DESIGN: An in vitro biomechanical study in lumbar cadaveric spines. METHODS: Twelve lumbar cadaveric segments (L4-S1) were tested under flexion-extension (FE), lateral bending (LB), and axial rotation (AR). Six treatments were simulated as follows: (1) intact, (2) bilateral facetectomy at L4-L5, (3) transdiscal screw system, (4) BPSS, (5) BPSS with transforaminal lumbar interbody cage, and (6) transdiscal screws with transforaminal interbody cage. Specimens were randomly divided into two testing groups: Group 1 (n=6) was tested under the first five conditions, in the order presented, whereas Group 2 (n=6) was tested under the first, second, third, fourth, and sixth conditions, with the fourth condition preceding the third. Range of motion (ROM) and neutral zone stiffness (NZS) were estimated and normalized with respect to the intact condition to explore statistical differences among treatments using non-parametric approaches. RESULTS: Significant differences in FE ROM were observed in the pedicle screws-cage condition with respect to the facetectomy (p<.01), the pedicle screw (p=.03), and the transdiscal screw (p<.02) conditions. All fixation constructs significantly restricted LB and AR ROM (p<.01) with respect to facetectomy. In terms of stiffness, the pedicle screw and the transdiscal screw systems increased (p<.01) LB and AR NZS with respect to facetectomy. The pedicle screws-cage condition significantly increased flexion and extension stiffness with respect to all other conditions (p<.05). However, LB NZS for the pedicle screws-cage and the transdiscal screws-cage condition could not be explored due to a testing order bias effect. There was not enough evidence to state any difference between the pedicle and transdiscal screw conditions in terms of ROM or NZS. CONCLUSIONS: Transdiscal and pedicle screw systems showed comparable in vitro biomechanical performance in the immediate stabilization of a complete bilateral facetectomy. The pedicle screws-cage condition was the most stable in FE motion; however, comparison with respect to the transdiscal screws-cage condition could not be investigated.


Assuntos
Parafusos Ósseos , Instabilidade Articular/cirurgia , Vértebras Lombares/cirurgia , Fusão Vertebral/instrumentação , Fenômenos Biomecânicos , Estudos de Viabilidade , Humanos , Fixadores Internos , Amplitude de Movimento Articular/fisiologia , Rotação , Fusão Vertebral/métodos
17.
Spine J ; 14(7): 1272-9, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24295796

RESUMO

BACKGROUND CONTEXT: Postoperative patient motions are difficult to directly control. Very slow quasistatic motions are intuitively believed to be safer for patients, compared with fast dynamic motions, because the torque on the spine is reduced. Therefore, the outcomes of varying axial rotation (AR) angular loading rate during in vitro testing could expand the understanding of the dynamic behavior and spine response. PURPOSE: To observe the effects of the loading rate in AR mechanics of lumbar cadaveric spines via in vitro biomechanical testing. STUDY DESIGN: An in vitro biomechanical study in lumbar cadaveric spines. METHODS: Fifteen lumbar cadaveric segments (L1-S1) were tested with varying loading frequencies of AR. Five different frequencies were normalized with the base line frequency (0.125 Hz n=15) in this analysis: 0.05 Hz (n=6), 0.166 Hz (n=6), 0.2 Hz (n=10), 0.25 Hz (n=10), and 0.4 Hz (n=8). RESULTS: The lowest frequency (0.05 Hz) revealed significant differences (p<.05) for all parameters (torque, passive angular velocity, axial velocity [AV], axial reaction force [RF], and energy loss [EL]) with respect to all other frequencies. Significant differences (p<.05) were observed in the following: torque (0.4 Hz with respect to 0.2 Hz and 0.25 Hz), passive sagittal angular velocity (SAV) (0.4 Hz with respect to all other frequencies; 0.166 Hz with respect to 0.25 Hz), axial linear velocity (0.4 Hz with respect to all other frequencies), and RF (0.4 Hz with respect to 0.2 Hz and 0.25 Hz). Strong correlations (R2>0.75, p<.05) were observed between RF with intradiscal pressure (IDP) and AR angular displacement with IDP. Intradiscal pressure (p<.05) was significantly larger in 0.2 Hz in comparison with 0.125 Hz. CONCLUSIONS: Evidences suggest that measurements at very small frequencies (0.05 Hz) of torque, SAV, AV, RF, and EL are significantly reduced when compared with higher frequencies (0.166 Hz, 0.2 Hz, 0.25 Hz, and 0.4 Hz). Higher frequencies increase torque, RF, passive SAV, and AV. Higher frequencies induce a greater IDP in comparison with lower frequencies.


Assuntos
Vértebras Lombares/fisiologia , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Amplitude de Movimento Articular/fisiologia , Rotação , Suporte de Carga
18.
Clin Biomech (Bristol, Avon) ; 28(5): 483-9, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23707137

RESUMO

BACKGROUND: Titanium pedicle screw-rod instrumentation is considered a standard treatment for spinal instability; however, the advantages of cobalt-chromium over titanium is generating interest in orthopedic practice. The aim of this study was to compare titanium versus cobalt-chromium rods in posterior fusion through in vitro biomechanical testing. METHODS: Posterior and middle column injuries were simulated at L3-L5 in six cadaveric L1-S1 human spines and different pedicle screw constructs were implanted. Specimens were subjected to flexibility tests and range of motion, intradiscal pressure and axial rotation energy loss were statistically compared among five conditions: intact, titanium rods (with and without transverse connectors) and cobalt-chromium rods (with and without transverse connectors). FINDINGS: All fusion constructs significantly (P<0.01) decreased range of motion in flexion-extension and lateral bending with respect to intact, but no significant differences (P>0.05) were observed in axial rotation among all conditions. Intradiscal pressure significantly increased (P≤0.01) after fusion, except for the cobalt-chrome conditions in extension (P≥0.06), and no significant differences (P>0.99) were found among fixation constructs. In terms of energy loss, differences became significant P≤0.05 between the cobalt-chrome with transverse connector condition with respect to the cobalt-chrome and titanium conditions. INTERPRETATION: There is not enough evidence to support that the cobalt-chrome rods performed biomechanically different than the titanium rods. The inclusion of the transverse connector only increased stability for the cobalt-chromium construct in axial rotation.


Assuntos
Ligas de Cromo , Vértebras Lombares/fisiopatologia , Teste de Materiais , Sacro/fisiopatologia , Fusão Vertebral/instrumentação , Traumatismos da Coluna Vertebral/terapia , Adulto , Fenômenos Biomecânicos , Parafusos Ósseos , Cadáver , Humanos , Técnicas In Vitro , Fixadores Internos , Vértebras Lombares/lesões , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Rotação , Sacro/lesões , Sacro/cirurgia , Fusão Vertebral/métodos , Titânio
SELEÇÃO DE REFERÊNCIAS