1.
Hear Res ; 365: 16-27, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29906653

RESUMO

Passive and active in-ear devices (IED) occluding the ear canal are commonly used to (i) protect people from high noise levels (earplugs), (ii) assist people suffering from hearing impairment (hearing aids) or (iii) help people in listening from their sound systems (earbuds). However, the usability and/or efficiency of IEDs can be greatly affected by several discomfort components (physical, acoustical and functional). The mechanical pressure exerted by the IED onto the ear canal walls is greatly suspected to affect the aforementioned comfort components. This physical characteristic is closely related to the displacement field induced by the IED insertion, which has to be known for a better understanding of perceived discomfort. Thus, this paper proposes to validate a method based on medical images to estimate the displacement field of the ear canal walls due to the insertion of an IED. The approach is validated on a human-like artificial ear with canal geometry deformed using two custom molded IEDs with controlled shapes. These geometries are obtained using computed tomography imaging and the displacement field is computed using a registration method. The errors due to the ear canal segmentation and to the registration steps are small enough to compute a relevant estimation of the expected displacement field. Results show that the amplitude of the displacement and its location into the ear canal can be evaluated with an accuracy of ±â€¯0.2 mm and ±â€¯0.4 mm respectively. Preliminary results on images with a degraded resolution indicate that the proposed approach used to assess the displacement field of the ear canal walls using computed tomography images could be applied on magnetic resonance images, which is a preferred method to image human subject ear canals for future investigations.


Assuntos
Simulação por Computador , Meato Acústico Externo/diagnóstico por imagem , Dispositivos de Proteção das Orelhas , Auxiliares de Audição , Modelos Anatômicos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Microtomografia por Raio-X/métodos , Meato Acústico Externo/anatomia & histologia , Desenho de Equipamento , Humanos , Imageamento por Ressonância Magnética , Masculino , Análise Numérica Assistida por Computador , Valor Preditivo dos Testes , Pressão , Impressão Tridimensional , Reprodutibilidade dos Testes
2.
J Acoust Soc Am ; 136(4): 1666-81, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25324070

RESUMO

This paper deals with the prediction of the macroscopic sound absorption behavior of highly porous polyurethane foams using two unit-cell microstructure-based models recently developed by Doutres, Atalla, and Dong [J. Appl. Phys. 110, 064901 (2011); J. Appl. Phys. 113, 054901 (2013)]. In these models, the porous material is idealized as a packing of a tetrakaidecahedra unit-cell representative of the disordered network that constitutes the porous frame. The non-acoustic parameters involved in the classical Johnson-Champoux-Allard model (i.e., porosity, airflow resistivity, tortuosity, etc.) are derived from characteristic properties of the unit-cell and semi-empirical relationships. A global sensitivity analysis is performed on these two models in order to investigate how the variability associated with the measured unit-cell characteristics affects the models outputs. This allows identification of the possible limitations of a unit-cell micro-macro approach due to microstructure irregularity. The sensitivity analysis mainly shows that for moderately and highly reticulated polyurethane foams, the strut length parameter is the key parameter since it greatly impacts three important non-acoustic parameters and causes large uncertainty on the sound absorption coefficient even if its measurement variability is moderate. For foams with a slight inhomogeneity and anisotropy, a micro-macro model associated to cell size measurements should be preferred.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...