Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 138(4): 402-6, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19926674

RESUMO

The Brazilian national regulatory authority, National Commission of Nuclear Energy, requires that dose rates in the vicinity of teletherapy treatment rooms do not exceed the permissible limits for workers as well as members of the public, depending on the place considered. At the end of 2005, the Brazilian national regulatory authority reduced the permissible dose limit for controlled areas from 1000 to 400 microSv week(-1). Therefore, the aim of this work is to verify the adequacy of structural shielding to this new limit for telecobalt units that had their sources changed and clinic linear accelerators (ALs) installed before the end of 2005. Considering the ALs, measurements of dose rates in controlled areas did not exceed the new permissible limit, excepting for a single case. In the case of (60)Co units, a similar situation is observed for controlled areas, although several non-conformities to the limit of uncontrolled area could be observed.


Assuntos
Aceleradores de Partículas , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação , Proteção Radiológica , Serviço Hospitalar de Radiologia/normas , Radioterapia de Alta Energia , Algoritmos , Brasil , Radioisótopos de Césio , Inquéritos Epidemiológicos , Humanos , Nêutrons , Exposição Ocupacional , Doses de Radiação
2.
Radiat Prot Dosimetry ; 131(2): 272-5, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18503063

RESUMO

Data related to 11 y of high-energy photon radiotherapy beam dosimetry are presented and analysed. Dosimetric evaluations were carried out using water phantoms and thimble ionisation chambers and are part of the radiation protection regulatory licensing process for medicine facilities of Brazilian government. Measurements were done at reference conditions for a standard absorbed dose of 100 cGy [cGy (=1 rad)]. The absolute per cent deviation between the measured and presumed delivered doses should not exceed the tolerance level of +/-3%. The first dosimetry survey from 1996 to 1998 showed a situation that was an object of concern. Deviations of 22 and 18.7% could be measured, although small deviations were also obtained. After 1998, the improvement in dosimetry quality control by the radiotherapy centres became clear, with most of the deviations situated within the +/-3% range. The decrease in the measured deviations presents the effective success of the Institute of Radiation Protection and Dosimetry audit programme for the improvement in the control of radiotherapy photon beams in Rio de Janeiro. Also, it is possible to recommend to Brazilian regulatory organisation a decrease in the tolerance level for dosimetric deviations in order to achieve a more precise dose delivered to patients in radiotherapy centres.


Assuntos
Fótons , Dosagem Radioterapêutica/normas , Radioterapia de Alta Energia/normas , Brasil , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Controle de Qualidade , Equipamentos e Provisões para Radiação , Radiometria , Radioterapia de Alta Energia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...