Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 103: 108-118, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36272328

RESUMO

PURPOSE: The first aim was to generate and compare synthetic-CT (sCT) images using a conditional generative adversarial network (cGAN) method (Pix2Pix) for MRI-only prostate radiotherapy planning by testing several generators, loss functions, and hyper-parameters. The second aim was to compare the optimized Pix2Pix model with five other architectures (bulk-density, atlas-based, patch-based, U-Net, and GAN). METHODS: For 39 patients treated by VMAT for prostate cancer, T2-weighted MRI images were acquired in addition to CT images for treatment planning. sCT images were generated using the Pix2Pix model. The generator, loss function, and hyper-parameters were tuned to improve sCT image generation (in terms of imaging endpoints). The final evaluation was performed by 3-fold cross-validation. This method was compared to five other methods using the following imaging endpoints: the mean absolute error (MAE) and mean error (ME) between sCT and reference CT images (rCT) of the whole pelvis, bones, prostate, bladder, and rectum. For dose planning analysis, the dose-volume histogram metric differences and 3D gamma analysis (local, 1 %/1 mm) were calculated using the sCT and reference CT images. RESULTS: Compared with the other architectures, Pix2Pix with Perceptual loss function and generator ResNet 9 blocks showed the lowest MAE (29.5, 107.7, 16.0, 13.4, and 49.1 HU for the whole pelvis, bones, prostate, bladder, and rectum, respectively) and the highest gamma passing rates (99.4 %, using the 1 %/1mm and 10 % dose threshold criterion). Concerning the DVH points, the mean errors were -0.2% for the planning target volume V95%, 0.1 % for the rectum V70Gy, and -0.1 % for the bladder V50Gy. CONCLUSION: The sCT images generated from MRI data with the Pix2Pix architecture had the lowest image errors and similar dose uncertainties (in term of gamma pass-rate and dose-volume histogram metric differences) than other deep learning methods.


Assuntos
Aprendizado Profundo , Próstata , Masculino , Humanos , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos , Pelve , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica
2.
Med Phys ; 48(1): 397-413, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33151543

RESUMO

PURPOSE: Gantry-free radiation therapy systems utilizing patient rotation would be simpler and more cost effective than the conventional gantry-based systems. Such a system could enable the expansion of radiation therapy to meet global demand and reduce capital costs. Recent advances in adaptive radiation therapy could potentially be applied to correct for gravitational deformation during horizontal patient rotation. This study aims to quantify the pelvic organ motion and the dosimetric implications of horizontal rotation for prostate intensity-modulated radiation therapy (IMRT) treatments. METHODS: Eight human participants who previously received prostate radiation therapy were imaged in a clinical magnetic resonance imaging (MRI) scanner using a bespoke patient rotation system (PRS). The patients were imaged every 45 degrees during a full roll rotation (0-360 degrees). Whole pelvic bone, prostate, rectum, and bladder motion were compared to the supine position using dice similarity coefficient (DSC) and mean absolute surface distance (MASD). Prostate centroid motion was compared in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) direction prior to and following pelvic bone-guided rigid registration. Seven-field prostate IMRT treatment plans were generated for each patient rotation angles under three adaption scenarios: No plan adaption, rigid planning target volume (PTV)-guided alignment to the prostate, and plan re-optimization. Prostate, rectum, and bladder doses were compared for each adaption scenario. RESULTS: Pelvic bone motion within the PRS of up to 53 mm relative to the supine position was observed for some participants. Internal organ motion was greatest at the 180-degree PRS couch angle (prone), with prostate centroid motion range < 2 mm LR, 0 mm to 14 mm SI, and -11 mm to 4 mm AP. Rotation with no adaption of the treatment plan resulted in an underdose to the PTV -- in some instances up to 75% (D95%: 78 ± 0.3 Gy at supine to 20 ± 15.0 Gy at the 225-degree PRS couch angle). Bladder dose was reduced during the rotation by up to 98% (V60 Gy: 15.0 ± 9.4% supine to 0.3 ± 0.5% at the 225-degree PRS couch angle). In some instances, the rectum dose increased during rotation (V60Gy: 20.0 ± 4.5% supine to 25.0 ± 15.0% at the 135-degree PRS couch angle). Rigid PTV-guided alignment resulted in PTV coverage which, though statistically lower (P < 0.05 for all D95% values), was within 1 Gy of the supine plans. Plan re-optimization resulted in a statistically equivalent PTV coverage compared to the supine plans (P > 0.05 for all D95% metrics and all within ±0.4 Gy). For both rigid PTV-guided alignment and plan re-optimization, rectum dose volume metrics were reduced compared to the supine position between the 90- and 225-degree PRS couch angles (P < 0.05). Bladder dose volume metrics were not impacted by rotation. CONCLUSION: Pelvic bone and internal organ motion are present during patient rotation. Rigid PTV-guided alignment to the prostate will be a requirement if prostate IMRT is to be safely delivered using patient rotation. Plan re-optimization for each PRS couch angle to account for anatomical deformations further improves the PTV coverage.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Movimentos dos Órgãos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Rotação
3.
Phys Med Biol ; 64(17): 175014, 2019 09 04.
Artigo em Inglês | MEDLINE | ID: mdl-31307023

RESUMO

Gantry-free radiation therapy systems may be simpler and more cost effective, particularly for MRI-guided photon or hadron therapy. This study aims to understand and quantify anatomical deformations caused by horizontal rotation with scan sequences sufficiently short to facilitate integration into an MRI-guided workflow. Rigid and non-rigid pelvic deformations due to horizontal rotation were quantified for a cohort of 8 healthy volunteers using a bespoke patient rotation system and a clinical MRI scanner. For each volunteer a reference scan was acquired at 0° followed by sequential faster scans in 45° increments through to 360°. All fast scans were registered to the 0° image via a three-step process: first, images were aligned using MR visible couch markers. Second, the scans were pre-processed then rigidly registered to the 0° image. Third, the rigidly registered scans were non-rigidly registered to the 0° image to assess soft tissue deformation. The residual differences after rigid and non-rigid registration were determined from the transformation matrix and the deformation vector field, respectively. The rigid registration yielded mean rotations of ⩽2.5° in all cases. The average 3D translational magnitudes range was 5.8 ± 2.9 mm-30.0 ± 11.0 mm. Translations were most significant in the left-right (LR) direction. Smaller translations were observed in the anterior-posterior (AP) and superior-inferior (SI) directions. The maximum deformation magnitudes range was: 10.0 ± 0.9 mm-28.0 ± 2.8 mm and average deformation magnitudes range: 2.3 ± 0.6 mm-7.5 ± 1.0 mm. Average non-rigid deformation magnitude was correlated with BMI (correlation coefficient 0.84, p  = 0.01). Rigid pelvic deformations were most significant in the LR direction but could be accounted for with on-line adjustments. Non-rigid deformations can be significant and will need to be accounted for in order to facilitate the delivery of gantry-free therapy with an automated patient rotation system.


Assuntos
Radioterapia Guiada por Imagem/métodos , Rotação , Algoritmos , Anatomia , Artefatos , Humanos , Imageamento por Ressonância Magnética
4.
Artigo em Inglês | MEDLINE | ID: mdl-30642923

RESUMO

Uropathogenic Escherichia coli (UPEC) is a frequent cause of catheter-associated urinary tract infection (CAUTI). Biocides have been incorporated into catheter coatings to inhibit bacterial colonization while, ideally, exhibiting low cytotoxicity and mitigating the selection of resistant bacterial populations. We compared the effects of long-term biocide exposure on susceptibility, biofilm formation, and relative pathogenicity in eight UPEC isolates. MICs, minimum bactericidal concentrations (MBCs), minimum biofilm eradication concentrations (MBECs), and antibiotic susceptibilities were determined before and after long-term exposure to triclosan, polyhexamethylene biguanide (PHMB), benzalkonium chloride (BAC), and silver nitrate. Biofilm formation was quantified using a crystal violet assay, and relative pathogenicity was assessed via a Galleria mellonella waxworm model. Cytotoxicity and the resulting biocompatibility index values were determined by use of an L929 murine fibroblast cell line. Biocide exposure resulted in multiple decreases in biocide susceptibility in planktonic and biofilm-associated UPEC. Triclosan exposure induced the largest frequency and magnitude of susceptibility decreases at the MIC, MBC, and MBEC, which correlated with an increase in biofilm biomass in all isolates. Induction of antibiotic cross-resistance occurred in 6/84 possible combinations of bacteria, biocide, and antibiotic. Relative pathogenicity significantly decreased after triclosan exposure (5/8 isolates), increased after silver nitrate exposure (2/8 isolates), and varied between isolates for PHMB and BAC. The biocompatibility index ranked the antiseptic potential as PHMB > triclosan > BAC > silver nitrate. Biocide exposure in UPEC may lead to reductions in biocide and antibiotic susceptibility, changes in biofilm formation, and alterations in relative pathogenicity. These data indicate the multiple consequences of biocide adaptation that should be considered when selecting an anti-infective catheter-coating agent.


Assuntos
Antibacterianos/farmacologia , Biofilmes/efeitos dos fármacos , Desinfetantes/farmacologia , Escherichia coli Uropatogênica/efeitos dos fármacos , Escherichia coli Uropatogênica/patogenicidade , Animais , Compostos de Benzalcônio/farmacologia , Biguanidas/farmacologia , Biofilmes/crescimento & desenvolvimento , Infecções Relacionadas a Cateter/tratamento farmacológico , Infecções Relacionadas a Cateter/microbiologia , Linhagem Celular , Ciprofloxacina/farmacologia , Farmacorresistência Bacteriana , Infecções por Escherichia coli/tratamento farmacológico , Gentamicinas/farmacologia , Células L , Camundongos , Testes de Sensibilidade Microbiana , Mariposas/microbiologia , Nitrofurantoína/farmacologia , Nitrato de Prata/farmacologia , Triclosan/farmacologia , Combinação Trimetoprima e Sulfametoxazol/farmacologia , Virulência/efeitos dos fármacos
5.
Phys Med Biol ; 63(3): 035001, 2018 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-29300184

RESUMO

Many similarity metrics exist for inter-observer contouring variation studies, however no correlation between metric choice and prostate cancer radiotherapy dosimetry has been explored. These correlations were investigated in this study. Two separate trials were undertaken, the first a thirty-five patient cohort with three observers, the second a five patient dataset with ten observers. Clinical and planning target volumes (CTV and PTV), rectum, and bladder were independently contoured by all observers in each trial. Structures were contoured on T2-weighted MRI and transferred onto CT following rigid registration for treatment planning in the first trial. Structures were contoured directly on CT in the second trial. STAPLE and majority voting volumes were generated as reference gold standard volumes for each structure for the two trials respectively. VMAT treatment plans (78 Gy to PTV) were simulated for observer and gold standard volumes, and dosimetry assessed using multiple radiobiological metrics. Correlations between contouring similarity metrics and dosimetry were calculated using Spearman's rank correlation coefficient. No correlations were observed between contouring similarity metrics and dosimetry for CTV within either trial. Volume similarity correlated most strongly with radiobiological metrics for PTV in both trials, including TCPPoisson (ρ = 0.57, 0.65), TCPLogit (ρ = 0.39, 0.62), and EUD (ρ = 0.43, 0.61) for each respective trial. Rectum and bladder metric correlations displayed no consistency for the two trials. PTV volume similarity was found to significantly correlate with rectum normal tissue complication probability (ρ = 0.33, 0.48). Minimal to no correlations with dosimetry were observed for overlap or boundary contouring metrics. Future inter-observer contouring variation studies for prostate cancer should incorporate volume similarity to provide additional insights into dosimetry during analysis.


Assuntos
Simulação por Computador , Imageamento por Ressonância Magnética/métodos , Variações Dependentes do Observador , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Masculino
6.
Appl Opt ; 30(4): 401-6, 1991 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20582005

RESUMO

Diffraction-limited low power laser beams at 1.06 and 3.8 microm were focused by a 91-cm diam aperture onto a receiver located 10.5 km away on a low slant angle path over a desert basin. The analysis of beam areas and turbulence levels was used to determine a new scaling law for tilt-corrected turbulence-induced beam spread.

7.
Appl Opt ; 24(21): 3512, 1985 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-18224078
9.
Opt Lett ; 1(4): 121-3, 1977 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-19680350

RESUMO

An example of high-resolution (0.08 cm(-1)), absolute transmission spectra of a 5-km atmospheric path is presented. Precise transmission and wavenumber calibration of the spectra were obtained from infrared laser extinction measurements. A comparison of these spectra to line-by-line calculations shows excellent agreement in the spectral region between 2480 and 2800 cm(-1) (3.57 to 4.03 microm).

10.
Artigo em Inglês | MEDLINE | ID: mdl-1029892

RESUMO

We have developed a gas liquid chromatographic assay for plasma acetate which detects 0.01 mM and has a standard deviation of less than 16% of the mean at 0.05 mM. The acetate concentration of venous blood obtained from normal subjects was 0.025 +/- 0.002 mM. The value was not significantly different from the venous acetate concentration of dialysis patients, prior to a dialysis treatment. The acetate concentration of arterial plasma obtained from dialysis patients prior to a hemodialysis treatment was 0.048 +/- 0.006 mM. This was significantly greater than the venous concentration of 0.027 +/- 0.002 (p less than 0.01). This arteriovenous difference suggests that acetate is utilized peripherally. At the onset of hemodialysis, acetate concentrations rapidly rose and, in all but one case, reached a steady state value in the range of 1.5-5.1 mM. At the termination of dialysis, acetate concentrations fell rapidly, usually achieving baseline values within one hr. The rate of decrease was not a simple logarithmic function, suggesting that acetate metabolism is not solely a first order function. Furthermore, acetate disappearance was more rapid in the dialysis patients than in the normal subjects. We wish to emphasize that the present data, which were obtained on a small number of subjects are preliminary and should be interpreted with caution.


Assuntos
Acetatos/sangue , Diálise Renal , Uremia/sangue , Acetatos/administração & dosagem , Acetatos/metabolismo , Cromatografia , Humanos , Infusões Parenterais , Propionatos/sangue , Uremia/metabolismo
13.
Appl Opt ; 8(9): 1867-74, 1969 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-20072536

RESUMO

Xenon gas has been compressively heated from 8000 K to 15 000 K at peak pressures of 800-2400 atm. Brightness measurements were made of the emitted radiation at selected wavelengths in the visible. In a few cases, a time-resolved spectrum was obtained. The results obtained from a theoretical analysis are shown to be in reasonable agreement with experimentally measured values. A high efficiency for conversion of mechanical energy to radiant energy is indicated and suggests the use of such a device as an efficient source for laser pumping.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...