Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 160(1-3): 62-4, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24707001

RESUMO

Radon time-series analysis, based on the short-term indoor radon measurements performed worldwide, shows two main periodicity: daily and seasonal. The information obtained from time series of the measured radon values is the results of the complex radon dynamics that arises from the influence of the large number of different parameters (the state of the indoor atmosphere (temperature, pressure and relative humidity, aerosol concentration), the exchange rate between indoor and outdoor air and so on). In this paper we considered daily radon variability in the underground low-background laboratory in Belgrade, Serbia. The results are originated from the radon time-series analysis based on the 3 y of the continuous short-term indoor radon measurements. At the same time, we obtained the time series of the temperature, pressure and relative humidity in the laboratory. We also tried to find the correlation between different time series.


Assuntos
Radiação de Fundo , Monitoramento de Radiação , Poluentes Radioativos/análise , Radônio/análise , Estações do Ano , Humanos , Laboratórios , Medição de Risco , Sérvia , Fatores de Tempo
2.
Radiat Prot Dosimetry ; 145(2-3): 155-8, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21459878

RESUMO

Measurements of radon concentration in the underground low-level laboratory in Belgrade, Serbia with a discrete sampling (T=2 h) have been performed. From July 2008 to July 2010, the time-series analysis was carried out. Also, the simultaneous measurements of meteorological parameters (temperature, atmospheric pressure and relative humidity) in the laboratory were done. The simultaneous monitoring of these parameters shows the correlation between temporal variations of radon concentration and meteorological parameters. Also, the radon time-series analysis has been used to study the possible correlation between the anomalous behaviour of the radon concentration and the local seismicity.


Assuntos
Poluentes Radioativos do Ar/análise , Monitoramento de Radiação , Radônio/análise , Humanos , Laboratórios , Sérvia , Fatores de Tempo
3.
Appl Radiat Isot ; 67(5): 719-22, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19231223

RESUMO

A simulation programme based on the Geant4 toolkit has been developed to simulate the coincident responses of a plastic scintillator and an HPGe detector to the cosmic-ray muons. The detectors are situated in a low-level underground laboratory (25 m.w.e). Primary positions, momentum directions and energies of the muons are sampled from the angular and energy distributions of the cosmic-ray muons at the shallow underground level. Obtained coincident spectra of both detectors are presented and discussed.


Assuntos
Método de Monte Carlo , Espectrometria gama/métodos , Simulação por Computador , Mésons , Contagem de Cintilação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...