Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
J Sports Sci Med ; 23(2): 436-444, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38841644

RESUMO

The purpose of this study was to examine the differences in thoracolumbar fascia (TLF) and lumbar muscle modulus in individuals with and without hamstring injury using shear wave elastography (SWE). Thirteen male soccer players without a previous hamstring injury and eleven players with a history of hamstring injury performed passive and active (submaximal) knee flexion efforts from 0°, 45° and 90° angle of knee flexion as well as an active prone trunk extension test. The elastic modulus of the TLF, the erector spinae (ES) and the multifidus (MF) was measured using ultrasound SWE simultaneously with the surface electromyography (EMG) signal of the ES and MF. The TLF SWE modulus was significantly (p < 0.05) higher in the injured group (range: 29.86 ± 8.58 to 66.57 ± 11.71 kPa) than in the uninjured group (range: 17.47 ± 9.37 to 47.03 ± 16.04 kPa). The ES and MF modulus ranged from 14.97 ± 4.10 to 66.57 ± 11.71 kPa in the injured group and it was significantly (p < .05) greater compared to the uninjured group (range: 11.65 ± 5.99 to 40.49 ± 12.35 kPa). TLF modulus was greater than ES and MF modulus (p < 0.05). Active modulus was greater during the prone trunk extension test compared to the knee flexion tests and it was greater in the knee flexion test at 0° than at 90° (p < 0.05). The muscle EMG was greater in the injured compared to the uninjured group in the passive tests only (p < 0.05). SWE modulus of the TLF and ES and MF was greater in soccer players with previous hamstring injury than uninjured players. Further research could establish whether exercises that target the paraspinal muscles and the lumbar fascia can assist in preventing individuals with a history of hamstring injury from sustaining a new injury.


Assuntos
Técnicas de Imagem por Elasticidade , Eletromiografia , Fáscia , Músculos Isquiossurais , Futebol , Humanos , Masculino , Futebol/lesões , Futebol/fisiologia , Adulto Jovem , Músculos Isquiossurais/lesões , Músculos Isquiossurais/fisiologia , Músculos Isquiossurais/diagnóstico por imagem , Fáscia/lesões , Fáscia/diagnóstico por imagem , Fáscia/fisiologia , Fáscia/fisiopatologia , Módulo de Elasticidade , Traumatismos em Atletas/fisiopatologia , Traumatismos em Atletas/diagnóstico por imagem , Adulto , Região Lombossacral/lesões , Região Lombossacral/diagnóstico por imagem , Músculos Paraespinais/diagnóstico por imagem , Músculos Paraespinais/fisiologia , Músculos Paraespinais/fisiopatologia , Adolescente
2.
J Anat ; 244(3): 438-447, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-37965913

RESUMO

The purpose of this study was to examine the effect of passive and active knee flexion efforts on the stiffness of the thoracolumbar (TLF), semitendinosus (STF), and semimembranosus fascia (SMF). Fourteen young healthy males participated in this study. Using ultrasound shear-wave elastography, fascia elastic modulus was measured at rest (passive condition) and during submaximal isometric knee flexion efforts (active condition) with the hip at neutral position and the knee flexed at 0°, 45°, and 90°. Analysis of variance designs indicated that when the knee was passively extended from 90° to 0°, shear modulus of the TLF, SMF, and STF increased significantly (p < 0.05). Similarly, active knee flexion contractions caused a significant increase in TLF, SMF, and STF shear modulus (p < 0.001). Compared to hamstring fascia, the TLF showed greater thickness but a lower shear modulus (p < 0.05) while STF modulus was greater compared that to SMF during active contraction (p < 0.05). These results indicate that exercising the hamstring muscles can remotely influence the stiffness of the fascia which surrounds the lumbar area.


Assuntos
Técnicas de Imagem por Elasticidade , Músculos Isquiossurais , Masculino , Humanos , Joelho , Articulação do Joelho/fisiologia , Músculos Isquiossurais/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Fáscia/diagnóstico por imagem , Amplitude de Movimento Articular/fisiologia , Módulo de Elasticidade , Músculo Esquelético/fisiologia
3.
J Ultrason ; 22(91): e245-e248, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36483787

RESUMO

We present a rare case of a common carotid artery wall hematoma after ultrasound-guided parathyroid fine-needle aspiration. The hematoma was detected within seconds from needle insertion, extending along the common carotid artery wall from the lower neck to the common carotid artery bifurcation, and it was quickly restricted with firm pressure. The patient only reported mild discomfort. A follow-up assessment by a vascular surgeon two hours later showed no signs of ischemic events and complete absorption of the hematoma without further clinical consequences. Physicians performing parathyroid fine-needle aspiration must be aware of this rare complication, which may be easily overlooked. Continuous meticulous sonographic surveillance during the fine needle aspiration procedure is the only way to directly diagnose this complication and apply immediate pressure to restrict it.

4.
Brachytherapy ; 21(6): 904-911, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35995724

RESUMO

PURPOSE: To estimate ocular geometry-related inaccuracies of the dosimetric plan in Ru-106 ophthalmic brachytherapy. METHODS AND MATERIALS: Thirty patients with intraocular lesions were treated with brachytherapy using a Ru-106 plaque-shell of inner radius of 12 mm. Magnetic resonance imaging was employed to determine the external scleral radius at tumor site and the tumor margins. A mathematical model was developed to determine the distance between the external sclera and the internal surface of the plaque associated with the tangential application of the plaque on the treated eye. Differences in delivered dose to the tumor apex, sclera and tumor margins as derived by considering the default eye-globe of standard size (external sclera radius = 12 mm) against the individual-specific eye globe were determined. RESULTS: The radius of external sclera at the tumor site was found to range between 10.90 and 13.05 mm for the patient cohort studied. When the patient specific eye-globe/tumor geometry is not taken into account, the delivered dose was found to be overestimated by 8.1% ± 4.1% (max = 15.3%) at tumor apex, by 1.5% ± 2.8% (max = 5.7%) at anterior tumor margin, by 16.6% ± 7.5% (max = 36.4%) at posterior tumor margin and 8.1% ± 3.8% (max = 13.2%) at central sclera of eyes with lower than the default radius. The corresponding dose overestimations for eyes with higher than the default radius was 13.5% ± 4.3% (max = 22.3%), 1.5% ± 2.8% (max = 5.7%), 12.6% ± 4.5% (max = 20.0%), and 15.1% ± 5.0% (max = 24.4%). CONCLUSIONS: The proposed patient-specific approach for Ru-106 brachytherapy treatment planning may improve dosimetric accuracy. Individualized treatment planning dosimetry may prevent undertreatment of intraocular tumors especially for highly myopic or hyperopic eyes.


Assuntos
Braquiterapia , Neoplasias Oculares , Humanos , Radioisótopos de Rutênio/uso terapêutico , Braquiterapia/métodos , Dosagem Radioterapêutica , Neoplasias Oculares/diagnóstico por imagem , Neoplasias Oculares/radioterapia , Neoplasias Oculares/patologia , Imageamento por Ressonância Magnética
5.
J Neuroophthalmol ; 42(1): e274-e280, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34629402

RESUMO

BACKGROUND: In this study we evaluate the diagnostic accuracy of extraocular muscle volumetry in detecting thyroid eye disease and to compare the results with simple measurements of maximal medial rectus (MR) diameter. METHODS: Cross-sectional study that included 47 eyes of 47 patients with thyroid eye disease and 47 healthy controls. Patients underwent slitlamp examination and imaging consisting of computed tomography scans. Image segmentation and volume measurements were performed by 2 independent researchers. Intraobserver and interobserver reliability testing was also conducted. RESULTS: Total extraocular muscle volume was 7.31 ± 1.88 cm3 and medial volume was 2.38 ± 0.73 cm3 in the study group. In this group, the maximum measured diameter of the MR was 6.67 ± 0.35 mm. MR volume was statistically associated with maximum MR diameter (r = 9.78; P < 0.001). Both MR volume and maximum MR diameter measurements showed good predictive efficacy as shown using receiver operator characteristic curve analysis. CONCLUSIONS: Complications of thyroid eye disease are often sight threatening, and timely diagnosis is crucial for the management of the entity and its sequelae. The results of this study imply that simple measurements of maximum MR diameter are sensitive enough to establish diagnosis.


Assuntos
Oftalmopatia de Graves , Estudos Transversais , Oftalmopatia de Graves/diagnóstico por imagem , Humanos , Músculos Oculomotores/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
6.
Med Ultrason ; 24(1): 117-119, 2022 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-33626124

RESUMO

The use of ultrasonography as a first line imaging test in cases of possible costal cartilage fracture can be pivotal. In this case report, we present the case of a patient with a suspected atraumatic vomiting-induced costal cartilage fracture. The costal cartilage fracture was non-displaced and incomplete, thus not visible in a Computed Tomography scan. When Ultrasound imaging was employed at the area of tenderness, soft tissue edema and hematoma around the cartilage were visualized. High level of suspicion for a cartilage fracture in this case revealed a subtle osseous injury.


Assuntos
Cartilagem Costal , Fraturas de Cartilagem , Fraturas das Costelas , Cartilagem/lesões , Cartilagem Costal/lesões , Fraturas de Cartilagem/complicações , Fraturas de Cartilagem/diagnóstico por imagem , Humanos , Vômito/diagnóstico por imagem , Vômito/etiologia
7.
J Hand Ther ; 35(4): 541-551, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33814224

RESUMO

BACKGROUND: Reviews on the diagnostic performance of the examination tests for lateral elbow tendinopathy (LET) based on updated context-specific tools and guidelines are missing. PURPOSE: To review the diagnostic accuracy of examination tests used in LET. DESIGN: Systematic review following PRISMA-DTA guidelines. METHODS: We searched MEDLINE, PubMed, CINAHL, EMBASE, PEDro, ScienceDirect, and Cochrane Library databases. The QUADAS-2 checklist was used to assess the methodological quality of the eligible studies. We included diagnostic studies reporting the accuracy of physical examination tests or imaging modalities used in patients with LET. RESULTS: Twenty-four studies with 1370 participants were identified reporting the diagnostic performance of Ultrasound Imaging (USI) (18 studies), physical examination tests (2 studies) and Magnetic Resonance Imaging (MRI) (4 studies). Most studies (97%) were assessed with "unclear" or "high risk" of bias. Sonoelastography showed the highest sensitivity (75- 100%) and specificity (85- 96%). Grayscale with or without Doppler USI presented poor to excellent values (sensitivity: 53%-100%, specificity: 42%-90%). MRI performed better in the diagnosis of tendon thickening and enthesopathy (sensitivity and specificity: 81%-100%). The Cozen's test reported high sensitivity (91%) while a grip strength difference of 5%-10% between elbow flexion and extension showed high sensitivity (78%-83%) and specificity (80%-90%). CONCLUSIONS: Cozen's test and grip strength measurement present high accuracy in the diagnosis of LET but are poorly investigated. USI and MRI provide variable diagnostic accuracy depending on the entities reported and should be recommended with caution when differential diagnosis is necessary. Substantial heterogeneity was found in inclusion criteria, operator/ examiner, mode of application, type of equipment and reference standards across the studies. SYSTEMATIC REVIEW REGISTRATION: PROSPERO ID CRD42020160402.


Assuntos
Tendinopatia do Cotovelo , Doenças Musculoesqueléticas , Tendinopatia , Humanos , Cotovelo , Tendinopatia do Cotovelo/diagnóstico , Ultrassonografia , Imageamento por Ressonância Magnética , Tendinopatia/diagnóstico , Sensibilidade e Especificidade
8.
Surg Radiol Anat ; 43(11): 1753-1764, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34524485

RESUMO

PURPOSE: To describe the cervical vagus nerve (CVN) topography at the thyroid lobe (TL) level using high-resolution ultrasound and to investigate the possible association with anthropometric data, TL size, and thyroid disease. METHODS: We prospectively examined 550 CVNs in 275 (205 female, 70 male) individuals with normal thyroid (53/275, 19.3%), multinodular disease (167/275, 60.7%), and Hashimoto thyroiditis (55/275, 20%). The CVN location relative to the common carotid artery was recorded as typical (lateral position) and atypical (anterior, medial, and posterior position). The shortest distance between CVN and TL margin, the TL dimensions, and volume were measured. RESULTS: Normal thyroid subjects had lateral-positioned right CVNs in 100% and lateral/anterior/medial left CVNs in 81.1%, 15.1%, and 3.8%, respectively. CVN types did not differ significantly bilaterally between study groups. Asymmetry in CVN topography in all subjects was found in 22.2%, of which anterior CVN was the most common atypical position (64%), especially on the left side (82%). Significant gender, age, body mass, and BMI differences among CVN types were observed on the left side only. Among CVN types, no difference in TL dimensions, volume, and CVN-TL distance was found in all study groups. A weak negative correlation was recorded between CVN-thyroid distance and TL volume only on the left side (r = - 0.147, p = 0.01). CONCLUSION: Asymmetry in CVN topography is mainly due to the increased incidence of the anterior location of CVN on the left side. Age and anthropometric parameters are different on the left side possibly due to the increased prevalence of left CVN variants.


Assuntos
Pescoço , Nervo Vago , Artérias Carótidas , Feminino , Humanos , Masculino , Glândula Tireoide/diagnóstico por imagem , Ultrassonografia
9.
Eur J Radiol ; 140: 109737, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33951567

RESUMO

Musculoskeletal (MSK) pathologies are one of the leading causes of disability worldwide. However, treatment options and understanding of pathogenetic processes are still partially unclear, mainly due to a limited ability in early disease detection and response to therapy assessment. In this scenario, thanks to a strong technological advancement, structural imaging is currently established as the gold-standard of diagnosis in many MSK disorders but each single diagnostic modality (plain films, high-resolution ultrasound, computed tomography and magnetic resonance) still suffer by a low specificity regarding the characterization of inflammatory processes, the quantification of inflammatory activity levels, and the degree of response to therapy. To overcome these limitations, molecular imaging techniques may play a promising role. Starting from the strengths and weaknesses of structural anatomical imaging, the present narrative review aims to highlight the promising role of molecular imaging in the assessment of non-neoplastic MSK diseases with a special focus on its role to monitor treatment response.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Imagem Molecular , Radiografia , Ultrassonografia
10.
Surg Radiol Anat ; 43(10): 1681-1689, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34032901

RESUMO

PURPOSE: This study aimed to examine the anatomic variations at the level of the distal soleus musculotendinous junction and the possible association between the length of the free tendon and the development of symptomatic Achilles tendinopathy. METHODS: We retrospectively assessed 72 ankle MRI studies with findings of Achilles tendinopathy (study group, 26 females/46 males, mean age 52.6 ± 10.5 years, 30 right/42 left) and 72 ankle MRI studies with normal Achilles tendon (control group, 32 females/40 males, mean age 35.7 ± 13.7 years, 42 right/30 left side). We measured the distance from the lowest outline of the soleus myotendinous junction to the proximal outline of the Achilles tendon insertion (length of the free tendon, diameter a) and to the distal outline of the insertion (distance B). We also measured the maximum thickness of the free tendon (diameter c) and the distance between the levels of maximum thickness to the proximal outline of the Achilles tendon insertion (distance D). All measurements were assessed twice. Statistical analysis was performed using independent t test. RESULTS: Distances A and B were significantly larger in tendinopathic tendons (59.7 and 83.4 mm, respectively) than normal Achilles tendons (38.5 and 60.8 mm, respectively) (p = 0.001). Mean distance C was larger in tendinopathic than normal tendons (11.2 versus 4.9 mm). Distances C and D were significantly larger in males than females. There was no significant difference in the measurements between sides. CONCLUSION: There is wide anatomical variation in the length of the free Achilles tendon. Tendinopathy may be associated with the thicker free part of the Achilles tendon. The anatomical variant of the high soleus musculotendinous junction resulting in a longer free Achilles tendon may be a predisposing factor to the development of tendinopathy.


Assuntos
Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/anormalidades , Tendinopatia/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
11.
Exp Ther Med ; 21(6): 650, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33968180

RESUMO

Pseudoexfoliation syndrome (PEX) is characterized by the deposition of proteinaceous material in the anterior ocular segment (resulting in ophthalmic pathologies such as glaucoma and increased risk of complications in cataract surgery), but also by several systemic manifestations. The involvement of peri-ocular tissues in PEX, including the eyelid skin, lacrimal gland, conjunctiva, orbital fat and vessels, as well as the optic nerve, has been reported by several previous studies. The peri-ocular effects of PEX include the development of eyelid laxity, conjunctival chalasis, tear film abnormalities, pronounced orbital fat atrophy in response to the administration of prostaglandin analogues in pseudoexfoliative glaucoma, deficient orbital vascular supply and biomechanical changes in both the eyeball and the optic nerve. These effects may have important clinical implications, including increased difficulty in cataract surgery, ocular surface disease and eyelid margin malpositions.

12.
J Ultrason ; 21(84): 12-21, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33791112

RESUMO

AIM: This imaging anatomy study aimed at detecting anatomical variations and potential interconnections of the superior peroneal retinaculum to other lateral stabilizing structures. MATERIALS AND METHODS: We retrospectively reviewed the imaging archives of 63 patients (38 females, 25 males, mean age 32.7, range 18-58 years) with available ankle US, MR and CT images to detect whether US and MR can detect the presence of interconnections between the superior peroneal retinaculum and the anterior talofibular ligament, inferior extensor retinaculum and peroneal tendon sheath. We evaluated the presence of common anatomical variations including low peroneus brevis muscle belly, peroneal tubercle, os peroneum, and retromalleolar fibular groove shape in relation to the presence of superior peroneal retinaculum connections. RESULTS: The connections of the superior peroneal retinaculum can be revealed on magnetic resonance imaging (MRI) and ultrasound (US). The connection to the anterior talofibular ligament was located (a) inferior to the lateral malleolus, (b) at the level of the lateral malleolus and (c) on both levels, respectively (a) 49.2% on MRI and 39.7% on US, p <0.05, (b) 44.4% and 58.7%, p <0.05, 36.5% and (c) 27%, p <0.05. Superior peroneal retinaculum-inferior extensor retinaculum (MRI 47.6%, US 28.6% p <0.001) and superior peroneal retinaculum-peroneal tendon sheath (MRI 22.2%, US 25.4% p >0.05) connections were also found both on MR and US. CONCLUSION: Ankle US and MR revealed interconnections between the superior peroneal retinaculum and the anterior talofibular ligament, inferior extensor retinaculum, and superior peroneal retinaculum. Our results are a starting point for further studies on the connections of the superior peroneal retinaculum and the applicability of ultrasound and MRI in assessing their occurrence. Knowledge of the anatomical connections of the superior peroneal retinaculum may help radiologists with the assessment of lateral ankle injuries, and surgeons with treatment planning.

13.
Brachytherapy ; 20(4): 828-834, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33785279

RESUMO

PURPOSE: Brachytherapy with Ru-106 is widely used for the treatment of intraocular tumors, and its efficacy depends on the accuracy of radioactive plaque placement. Ru-106 plaques are MRI incompatible and create severe metal artifacts on conventional CT scans. Dual-energy CT scans (DECT) may be used to suppress such artifacts. This study examines the possibility of creating fusion images from MRI scans (preoperatively) and DECT scans (with the plaque in place) as a tool for confirming the anatomic accuracy of plaque placement. METHODS AND MATERIALS: Six patients with intraocular lesions (5 with choroidal melanoma and 1 with a retinal vasoproliferative lesion) were included. Fusion images of preoperative MRI scans and DECT scans with the plaque in place were created with the Demo version of the ImFusion suite (ImFusion GmbH, Munchen Germany). Clearance margins between the tumor and plaque edge in axial, transverse, and coronal planes as well as the elevation of the posterior plaque edge from the sclera were recorded and associated with the location of the lesion. RESULTS: Plaque-tumor clearance margins for transverse, sagittal, and coronal planes were higher for anteriorly located lesions (5.13 mm ± 0.11 [5.0-5.2], 5.10 mm ± 0.26 [4.9-5.4], and 5.33 mm ± 0.45 [4.9-5.8] respectively) than for posteriorly located lesions (4.16 mm ± 1.44 [2.5-5.1], 4.13 mm ± 1.42 [2.5-5.1], and 4.2 mm ± 1.21 [2.8-5.0], respectively). The elevation of the posterior plaque edge from the sclera was 0.33 mm ± 0.28 [0-0.5] and 0.63 mm ± 0.60 [0.7-1.2] for posterior and anterior lesions, respectively. CONCLUSIONS: Fusion images between DECT and MRI scans may be used as a tool to confirm the accuracy of Ru-106 plaque placement in relation with the intraocular tumors in ophthalmic brachytherapy.


Assuntos
Braquiterapia , Radioisótopos de Rutênio , Braquiterapia/métodos , Humanos , Imageamento por Ressonância Magnética , Radioisótopos de Rutênio/uso terapêutico , Tomografia Computadorizada por Raios X
14.
Curr Med Imaging ; 17(9): 1041-1053, 2021 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-33319691

RESUMO

Ultrasound elastography has become available in everyday practice, allowing direct measurement of tissue elasticity with important and expanding clinical applications. Several studies that have evaluated pathological and non-pathological tissues have demonstrated that ultrasound elastography can actually improve the diagnostic accuracy of the underlying disease process by detecting differences in their elasticity. Ocular and periocular tissues can also be characterized by their elastic properties. In this context, a comprehensive review of literature on ultrasound elastography as well as its current applications in Ophthalmology is presented.


Assuntos
Técnicas de Imagem por Elasticidade , Elasticidade , Olho/diagnóstico por imagem , Face
15.
J Ultrason ; 20(82): e210-e213, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33365159

RESUMO

We report the case of a 40-year-old man presenting at the emergency department with ankle and feet edema due to acute sarcoidosis (Lofgren syndrome). The diagnosis was suggested based on an ultrasound examination showing bilateral asymmetrical tenosynovitis of the flexor tendons with hypervascular subcutaneous cellulitis without any significant ankle and foot joint effusion or synovitis. This case report highlights the crucial role of ultrasound imaging as the first-line diagnostic tool in the investigation of a non-specific clinical condition, when performed by a knowledgeable sonographer with attention to detail. Radiologists performing ultrasound should be aware of the presenting ultrasound pattern of acute soft tissue sarcoidosis, and should include this entity in the differential diagnosis of patients with distal lower extremity swelling, tenosynovitis and hypervascular subcutaneous cellulitis, in order to narrow down the differential diagnosis and facilitate the clinical workup of the patient.

17.
Natl J Maxillofac Surg ; 11(1): 20-27, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33041572

RESUMO

INTRODUCTION: Current volume measurement techniques, for the orbit, are time-consuming and involve complex assessments, which prevents their routine clinical use. In this study, we evaluate the applicability and efficacy of stereology and planimetry in orbital volume measurements using magnetic resonance imaging (MRI). MATERIALS AND METHODS: Prospective imaging study using MRI. Sheep craniums and human subjects were evaluated. Water-filling measurements were performed in animal skulls, as the standard validation technique. Planimetry and stereology techniques were used in each dataset. Intraobserver and interobserver reliability testing were applied. RESULTS: In stereology customization, 1/6 systematic sampling scheme was determined as optimal with acceptable coefficient of error (3.09%) and low measurement time (1.2 min). In sheep craniums, the mean volume measured by water displacement, planimetry, and stereology was 17.81 ± 0.59 cm3, 18.53 ± 0.24 cm3, and 19.19 ± 0.17 cm3, respectively. Planimetric and stereological methods were highly correlated (r = 0.94; P ≈ 0.001). The mean difference of the orbital volume using planimetry and stereology was 0.316 ± 0.168 cm3. In human subjects, using stereology, the mean orbital volume was found to be 19.62 ± 0.2 cm3 with a CE of 3.91 ± 0.15%. CONCLUSIONS: The optimized stereological method was found superior to manual planimetry in terms of user effort and time spent. Stereology sampling of 1/6 was successfully applied in human subjects and showed strong correlation with manual planimetry. However, optimized stereological method tended to overestimate the orbital volume by about 1 cc, a considerable limitation to be taken in clinical practice.

18.
Semin Musculoskelet Radiol ; 24(3): 323-330, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32987429

RESUMO

No official data exist on the status of musculoskeletal (MSK) radiology in Europe. The Committee for National Societies conducted an international survey to understand the status of training, subspecialization, and local practice among the European Society of Musculoskeletal Radiology (ESSR) partner societies. This article reports the results of that survey. An online questionnaire was distributed to all 26 European national associations that act as official partner societies of the ESSR. The 24 questions were subdivided into six sections: society structure, relationship with the national radiological society, subspecialization, present radiology practice, MSK interventional procedures, and MSK ultrasound. The findings of our study show a lack of standardized training and/or accreditation methods in the field of MSK radiology at a national level. The European diploma in musculoskeletal radiology is directed to partly overcome this problem; however, this certification is still underrecognized. Using certification methods, a more homogeneous European landscape could be created in the future with a view to subspecialist training. MSK ultrasound and MSK interventional procedures should be performed by a health professional with a solid knowledge of the relevant imaging modalities and sufficient training in MSK radiology. Recognition of MSK radiology as an official subspecialty would make the field more attractive for younger colleagues as well as attracting the brightest and best, an important key to further development of both clinical and academic radiology. KEY POINTS: · Standardized training and/or accreditation methods in the field of MSK radiology is lacking at a national level.. · With certification methods, such as the European diploma in musculoskeletal radiology, a more homogeneous European landscape could be created in the future with a view to subspecialist training.. · Recognition of MSK radiology as an official subspecialty would make the field more attractive for younger colleagues as well as attracting the brightest and best, an important key to further development of both clinical and academic radiology..


Assuntos
Diagnóstico por Imagem/tendências , Doenças Musculoesqueléticas/diagnóstico por imagem , Europa (Continente) , Humanos , Sociedades Médicas
19.
Eur Radiol ; 30(2): 903-913, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31529252

RESUMO

BACKGROUND: Image-guided interventional procedures around the shoulder are commonly performed in clinical practice, although evidence regarding their effectiveness is scarce. We report the results of a Delphi method review of evidence on literature published on image-guided interventional procedures around the shoulder with a list of clinical indications. METHODS: Forty-five experts in image-guided musculoskeletal procedures from the ESSR participated in a consensus study using the Delphic method. Peer-reviewed papers regarding interventional procedures around the shoulder up to September 2018 were scored according to the Oxford Centre for Evidence-based Medicine levels of evidence. Statements on clinical indications were constructed. Consensus was considered as strong if more than 95% of experts agreed and as broad if more than 80% agreed. RESULTS: A total of 20 statements were drafted, and 5 reached the highest level of evidence. There were 10 statements about tendon procedures, 6 about intra-articular procedures, and 4 about intrabursal injections. Strong consensus was obtained in 16 of them (80%), while 4 received broad consensus (20%). CONCLUSIONS: Literature evidence on image-guided interventional procedures around the shoulder is limited. A strong consensus has been reached for 80% of statements. The ESSR recommends further research to potentially influence treatment options, patient outcomes, and social impact. KEY POINTS: • Expert consensus produced a list of 20 evidence-based statements on clinical indications of image-guided interventional procedures around the shoulder. • The highest level of evidence was reached for five statements. • Strong consensus was obtained for 16 statements (80%), while 4 received broad consensus (20%).


Assuntos
Procedimentos Ortopédicos/métodos , Ombro/cirurgia , Cirurgia Assistida por Computador/métodos , Consenso , Técnica Delphi , Humanos , Sistema Musculoesquelético/cirurgia , Radiografia , Radiologia , Sociedades Médicas
20.
Eur Radiol ; 30(4): 2220-2230, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31844963

RESUMO

BACKGROUND: Although image-guided interventional procedures of the elbow and wrist are routinely performed, there is poor evidence in the literature concerning such treatments. Our aim was to perform a Delphi-based consensus on published evidence on image-guided interventional procedures around the elbow and wrist and provide clinical indications on this topic. METHODS: A board of 45 experts in image-guided interventional musculoskeletal procedures from the European Society of Musculoskeletal Radiology were involved in this Delphi-based consensus study. All panelists reviewed and scored published papers on image-guided interventional procedures around the elbow and wrist updated to September 2018 according to the Oxford Centre for Evidence-based Medicine levels of evidence. Consensus on statements drafted by the panelists about clinical indications was considered as "strong" when more than 95% of panelists agreed and as "broad" if more than 80% agreed. RESULTS: Eighteen statements were drafted, 12 about tendon procedures and 6 about intra-articular procedures. Only statement #15 reached the highest level of evidence (ultrasound-guided steroid wrist injections result in greater pain reduction and greater likelihood of attaining clinically important improvement). Seventeen statements received strong consensus (94%), while one received broad consensus (6%). CONCLUSIONS: There is still poor evidence in published papers on image-guided interventional procedures around the elbow and wrist. A strong consensus has been achieved in 17/18 (94%) statements provided by the panel on clinical indications. Large prospective randomized trials are needed to better define the role of these procedures in clinical practice. KEY POINTS: • The panel provided 18 evidence-based statements on clinical indications of image-guided interventional procedures around the elbow and wrist. • Only statement #15 reached the highest level of evidence: ultrasound-guided steroid wrist injections result in greater pain reduction and greater likelihood of attaining clinically important improvement. • Seventeen statements received strong consensus (94%), while broad consensus was obtained by 1 statement (6%).


Assuntos
Doença de De Quervain/terapia , Tendinopatia do Cotovelo/terapia , Radiografia Intervencionista , Dedo em Gatilho/terapia , Ultrassonografia de Intervenção , Técnica Delphi , Agulhamento Seco , Articulação do Cotovelo , Fluoroscopia , Glucocorticoides/administração & dosagem , Humanos , Ácido Hialurônico/administração & dosagem , Injeções , Injeções Intra-Articulares , Plasma Rico em Plaquetas , Estudos Prospectivos , Radiografia , Tenotomia , Viscossuplementos/administração & dosagem , Articulação do Punho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...