Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Biomed Eng ; 52(4): 816-831, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38374520

RESUMO

For traumatic lumbar spine injuries, the mechanisms and influence of anthropometrical variation are not yet fully understood under dynamic loading. Our objective was to evaluate whether geometrically subject-specific explicit finite element (FE) lumbar spine models based on state-of-the-art clinical CT data combined with general material properties from the literature could replicate the experimental responses and the fracture locations via a dynamic drop tower-test setup. The experimental CT datasets from a dynamic drop tower-test setup were used to create anatomical details of four lumbar spine models (T12 to L5). The soft tissues from THUMS v4.1 were integrated by morphing. Each model was simulated with the corresponding loading and boundary conditions from the dynamic lumbar spine tests that produced differing injuries and injury locations. The simulations resulted in force, moment, and kinematic responses that effectively matched the experimental data. The pressure distribution within the models was used to compare the fracture occurrence and location. The spinal levels that sustained vertebral body fracture in the experiment showed higher simulation pressure values in the anterior elements than those in the levels that did not fracture in the reference experiments. Similarly, the spinal levels that sustained posterior element fracture in the experiments showed higher simulation pressure values in the vertebral posterior structures compared to those in the levels that did not sustain fracture. Our study showed that the incorporation of the spinal geometry and orientation could be used to replicate the fracture type and location under dynamic loading. Our results provided an understanding of the lumbar injury mechanisms and knowledge on the load thresholds that could be used for injury prediction with explicit FE lumbar spine models.


Assuntos
Fraturas da Coluna Vertebral , Traumatismos da Coluna Vertebral , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/lesões , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fenômenos Mecânicos , Fenômenos Biomecânicos , Análise de Elementos Finitos
2.
J Biomech Eng ; 143(4)2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33332544

RESUMO

A validation comparing five human body model (HBM) lumbar spines is carried out across two load cases, with the objective to use and apply HBMs in high strain rate applications such as car occupant simulation. The first load case consists of an individual intervertebral disc (IVD) loaded in compression at a strain rate of 1/s by a material testing machine. The second load case is a lumbar functional spine unit (FSU) loaded in compression using a drop tower setup, producing strain rates of up to 48/s. The IVD simulations were found to have a better agreement with the experiments than the FSU simulations, and the ranking of which HBMs matched best to the experiment differed by load case. These observations suggest the need for more hierarchical validations of the lumbar spine for increasing the utility of HBMs in high strain rate loading scenarios.


Assuntos
Disco Intervertebral
3.
Traffic Inj Prev ; 20(sup2): S171-S174, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31674808

RESUMO

Objective: The goal of the study was to assess the feasibility of a safe crash environment for volunteer tests in reclined seating positions. An iterative multimodal approach was chosen, consisting of full-body human body model (HBM) simulations, anthropomorphic test device (ATD) physical testing, and volunteer testing.Methods: To estimate a noninjurious deceleration pulse, the iterative inclination of the seat was supported through HBM simulations and physical ATD testing. One male volunteer was exposed to 5 low-speed frontal sled impacts with stepwise reclined seat angles. The volunteer was restrained with a non-pretensioned 3-point seat belt. All procedures were approved by the relevant ethics boards.Results: Volunteer sled tests in 3 different seat configurations were performed with one volunteer at noninjurious deceleration levels. Inclination of the seat and the absence of a footrest resulted in elevated axial seat reaction forces and almost pure translational motion of the human body.Conclusions: A maximum speed of 7.1 km/h and peak deceleration of 3.0 g was found to be a safe pulse for volunteer testing in frontal impacts with a rigid reclined seat. Larger soft tissue deformations were observed when reclined, possibly associated with higher shear loads within the soft tissue. Preliminary results highlight trade-offs between the degree of seat angulation, friction force, and restraint capability of a 3-point seat belt, thus causing forward translation and/or axial spinal compression of the occupant that may need to be addressed in the future.


Assuntos
Acidentes de Trânsito , Meios de Transporte , Adulto , Desaceleração , Estudos de Viabilidade , Voluntários Saudáveis , Humanos , Masculino , Segurança , Cintos de Segurança , Meios de Transporte/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...