Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JCO Glob Oncol ; 10: e2300345, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38359372

RESUMO

PURPOSE: Pediatric radiotherapy is a necessary and challenging component of oncologic care for children in low- and middle-income countries (LMICs). Collaboration between institutions in LMICs and high-income countries (HICs) has been shown to be effective in improving oncologic treatment outcomes; however, literature regarding pediatric radiotherapy twinning partnerships is limited. METHODS: Emory University has a long-standing twinning collaboration with Tikur Anbessa Specialized Hospital (TASH) for certain medical specialties. After securing institutional funding, a faculty member and a resident from the Emory University Department of Radiation Oncology set out to establish a twinning program with TASH for pediatric radiotherapy. RESULTS: Emory and TASH faculty and residents established initial communications virtually via email and video correspondence. TASH residents and faculty completed surveys regarding pediatric radiotherapy institutional and educational needs to outline goals of collaboration. Five lectures and case-based practicums were identified focused on Wilms tumor, medulloblastoma, rhabdomyosarcoma, Hodgkin lymphoma, and palliative radiotherapy. The Emory team then conducted a visit to TASH during which lectures and practicums were delivered. The Emory team directly observed and guided simulation and treatment planning procedures. TASH residents practiced decision making, simulation, contouring, and field placement for Wilms tumor cases on the basis of didactics and feedback provided by the Emory team. Additionally, a needs assessment regarding pediatric oncologic resources was completed. Clinical care pathways and standard operating procedures were drafted by collaborators. Virtual peer-review sessions were established to continue collaborations abroad and plan for next in-person visit. CONCLUSION: Collaborative efforts by global experts have helped to establish and improve treatment protocols for childhood cancer. The presented twinning experience may serve as a model for other LMIC and HIC centers for establishing similar partnerships.


Assuntos
Neoplasias Renais , Radioterapia (Especialidade) , Tumor de Wilms , Humanos , Criança , Países em Desenvolvimento , Atenção à Saúde
2.
Cureus ; 13(11): e19777, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34950555

RESUMO

Treatment for recurrent intracranial neoplasms is often difficult and less standardized. Since its approval by the Food & Drug Administration (FDA), GammaTileTM (GT, GT Medical Technologies, Tempe, AZ), a novel collagen tile cesium brachytherapy, has been investigated for use in this population. This study presents the initial experience with the use of GT for patients with recurrent intracranial neoplasms at a tertiary referral center. A retrospective analysis of all patients with GT implantation from November 2019 to July 2021 was performed. Information regarding demographics, clinical history, imaging data, prior tumor treatment, dosing, surgical complications, and outcomes was collected. Twelve patients were included in this study. Pathologies included gliomas (five patients), meningiomas (five patients), and metastatic tumors (two patients). The median tumor volume treated was 24 cc (IQR: 21.2 - 31.3 cc), and patients had a median of 7.5 tiles implanted (IQR: 5.4 - 10.3). One patient had a delayed epidural hematoma requiring reoperation, which was unrelated to GT implantation. Median follow-up was seven months (IQR: 3 -10), with the longest follow-up time of 20 months. Two patients have had local disease recurrence and three patients have had systemic progression of their disease. Three patients are deceased with survivals of 2.9, 4.8, and 5.8 months. Collagen tile brachytherapy is a safe and viable option for patients with recurrent intracranial tumors. Our data are consistent with early results seen at other institutions. Long-term data with larger patient populations are required to assess efficacy, safety, and indications for the use of this novel technology.

3.
Med Phys ; 48(10): e830-e885, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34036590

RESUMO

The charges on this task group (TG) were as follows: (a) provide specific procedural guidelines for performing the tests recommended in TG 142; (b) provide estimate of the range of time, appropriate personnel, and qualifications necessary to complete the tests in TG 142; and (c) provide sample daily, weekly, monthly, or annual quality assurance (QA) forms. Many of the guidelines in this report are drawn from the literature and are included in the references. When literature was not available, specific test methods reflect the experiences of the TG members (e.g., a test method for door interlock is self-evident with no literature necessary). In other cases, the technology is so new that no literature for test methods was available. Given broad clinical adaptation of volumetric modulated arc therapy (VMAT), which is not a specific topic of TG 142, several tests and criteria specific to VMAT were added.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Aceleradores de Partículas , Garantia da Qualidade dos Cuidados de Saúde , Dosagem Radioterapêutica
4.
Med Phys ; 47(9): 4115-4124, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32484573

RESUMO

PURPOSE: High-dose-rate (HDR) brachytherapy is an established technique to be used as monotherapy option or focal boost in conjunction with external beam radiation therapy (EBRT) for treating prostate cancer. Radiation source path reconstruction is a critical procedure in HDR treatment planning. Manually identifying the source path is labor intensive and time inefficient. In recent years, magnetic resonance imaging (MRI) has become a valuable imaging modality for image-guided HDR prostate brachytherapy due to its superb soft-tissue contrast for target delineation and normal tissue contouring. The purpose of this study is to investigate a deep-learning-based method to automatically reconstruct multiple catheters in MRI for prostate cancer HDR brachytherapy treatment planning. METHODS: Attention gated U-Net incorporated with total variation (TV) regularization model was developed for multi-catheter segmentation in MRI. The attention gates were used to improve the accuracy of identifying small catheter points, while TV regularization was adopted to encode the natural spatial continuity of catheters into the model. The model was trained using the binary catheter annotation images offered by experienced physicists as ground truth paired with original MRI images. After the network was trained, MR images of a new prostate cancer patient receiving HDR brachytherapy were fed into the model to predict the locations and shapes of all the catheters. Quantitative assessments of our proposed method were based on catheter shaft and tip errors compared to the ground truth. RESULTS: Our method detected 299 catheters from 20 patients receiving HDR prostate brachytherapy with a catheter tip error of 0.37 ± 1.68 mm and a catheter shaft error of 0.93 ± 0.50 mm. For detection of catheter tips, our method resulted in 87% of the catheter tips within an error of less than ± 2.0 mm, and more than 71% of the tips can be localized within an absolute error of no >1.0 mm. For catheter shaft localization, 97% of catheters were detected with an error of <2.0 mm, while 63% were within 1.0 mm. CONCLUSIONS: In this study, we proposed a novel multi-catheter detection method to precisely localize the tips and shafts of catheters in three-dimensional MRI images of HDR prostate brachytherapy. It paves the way for elevating the quality and outcome of MRI-guided HDR prostate brachytherapy.


Assuntos
Braquiterapia , Neoplasias da Próstata , Catéteres , Humanos , Imageamento por Ressonância Magnética , Masculino , Redes Neurais de Computação , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica
5.
Med Phys ; 46(7): 3133-3141, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31050804

RESUMO

PURPOSE: Stereotactic radiosurgery (SRS) is widely used to obliterate arteriovenous malformations (AVMs). Its performance relies on the accuracy of delineating the target AVM. Manual segmentation during a framed SRS procedure is time consuming and subject to inter- and intraobserver variation. To address these drawbacks, we proposed a deep learning-based method to automatically segment AVMs on CT simulation image sets. METHODS: We developed a deep learning-based method using a deeply supervised three-dimensional (3D) V-Net with a compound loss function. A 3D supervision mechanism was integrated into a residual network, V-Net, to deal with the optimization difficulties when training deep networks with limited training data. The proposed compound loss function including logistic and Dice losses encouraged similarity and penalized discrepancy simultaneously between prediction and training dataset; this was utilized to supervise the 3D V-Net at different stages. To evaluate the accuracy of segmentation, we retrospectively investigated 80 AVM patients who had CT simulation and digital subtraction angiography (DSA) acquired prior to treatment. The AVM target volume was segmented by our proposed method. They were compared with clinical contours approved by physicians with regard to Dice overlapping, difference in volume and centroid, and dose coverage changes on original plan. RESULTS: Contours created by the proposed method demonstrated very good visual agreement to the ground truth contours. The mean Dice similarity coefficient (DSC), sensitivity and specificity of the contours delineated by our method were >0.85 among all patients. The mean centroid distance between our results and ground truth was 0.675 ± 0.401 mm, and was not significantly different in any of the three orthogonal directions. The correlation coefficient between ground truth and AVM volume resulting from the proposed method was 0.992 with statistical significance. The mean volume difference among all patients was 0.076 ± 0.728 cc; there was no statistically significant difference. The average differences in dose metrics were all less than 0.2 Gy, with standard deviation less than 1 Gy. No statistically significant differences were observed in any of the dose metrics. CONCLUSION: We developed a novel, deeply supervised, deep learning-based approach to automatically segment the AVM volume on CT images. We demonstrated its clinical feasibility by validating the shape and positional accuracy, and dose coverage of the automatic volume. These results demonstrate the potential of a learning-based segmentation method for delineating AVMs in the clinical setting.


Assuntos
Malformações Arteriovenosas/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Meios de Contraste , Processamento de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Radiocirurgia , Tomografia Computadorizada por Raios X , Automação , Encéfalo/efeitos da radiação , Humanos
6.
Med Phys ; 36(9): 4197-212, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19810494

RESUMO

The task group (TG) for quality assurance of medical accelerators was constituted by the American Association of Physicists in Medicine's Science Council under the direction of the Radiation Therapy Committee and the Quality Assurance and Outcome Improvement Subcommittee. The task group (TG-142) had two main charges. First to update, as needed, recommendations of Table II of the AAPM TG-40 report on quality assurance and second, to add recommendations for asymmetric jaws, multileaf collimation (MLC), and dynamic/virtual wedges. The TG accomplished the update to TG-40, specifying new test and tolerances, and has added recommendations for not only the new ancillary delivery technologies but also for imaging devices that are part of the linear accelerator. The imaging devices include x-ray imaging, photon portal imaging, and cone-beam CT. The TG report was designed to account for the types of treatments delivered with the particular machine. For example, machines that are used for radiosurgery treatments or intensity-modulated radiotherapy (IMRT) require different tests and/or tolerances. There are specific recommendations for MLC quality assurance for machines performing IMRT. The report also gives recommendations as to action levels for the physicists to implement particular actions, whether they are inspection, scheduled action, or immediate and corrective action. The report is geared to be flexible for the physicist to customize the QA program depending on clinical utility. There are specific tables according to daily, monthly, and annual reviews, along with unique tables for wedge systems, MLC, and imaging checks. The report also gives specific recommendations regarding setup of a QA program by the physicist in regards to building a QA team, establishing procedures, training of personnel, documentation, and end-to-end system checks. The tabulated items of this report have been considerably expanded as compared with the original TG-40 report and the recommended tolerances accommodate differences in the intended use of the machine functionality (non-IMRT, IMRT, and stereotactic delivery).


Assuntos
Aceleradores de Partículas/instrumentação , Segurança de Equipamentos , Humanos , Controle de Qualidade , Radiometria/métodos , Cintilografia/instrumentação , Cintilografia/métodos , Radioterapia/instrumentação , Radioterapia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...