Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 156(2): 184-9, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23651656

RESUMO

To evaluate the quality of the radiographic films in Brazil, according to the recommendations of ISO 9236-1, a radiographic images simulator was used. A study of the control of the quality in radiographic films was implemented. With regard to this study, the results of five films of different manufacturers are presented. The characteristic curves for the ISO qualities of 55, 70, 90 and 120 kV are presented. The PTW REX simulator was used to determine the image quality parameters. Film 2 presents problems due to high sensitivity. Film 1 has a higher energy dependence than the other films. Film 5 yields the best results for almost all the sensitometric parameters. In conclusion, existing films in the Brazilian market vary considerably with relation to image quality.


Assuntos
Diagnóstico por Imagem , Intensificação de Imagem Radiográfica/instrumentação , Radiologia/normas , Filme para Raios X/normas , Ecrans Intensificadores para Raios X/normas , Brasil , Simulação por Computador , Humanos , Imagens de Fantasmas , Controle de Qualidade , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos
2.
Radiat Prot Dosimetry ; 147(4): 614-8, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21273198

RESUMO

The PTW REX phantom was used to study the radiographic image quality parameters in X-ray devices in the X-ray Diagnostics Department, as well as the system of film processing at the University Hospital of Rio de Janeiro State. X-ray devices were evaluated by performing tests on 11 screen-film combinations from X-ray devices in 3 rooms. The results showed that six film-screen combinations exhibited poor performances. For determination of air kerma output in the X-ray field, two devices presented significant variation >2 %. The grid attenuation factor in three devices had been approved, while two films were within the limits of sensitometric specifications. The modulation transfer function, which evaluates the level of image degradation, revealed that five film-screen combinations exhibited bad performance. The tests with the REX phantom revealed that the X-ray equipment and the system of processing at the University Hospital presented discrepancies in relation to the expected values, contributing to loss of quality of the radiographs.


Assuntos
Controle de Qualidade , Intensificação de Imagem Radiográfica/instrumentação , Filme para Raios X/normas , Ecrans Intensificadores para Raios X/normas , Simulação por Computador , Humanos , Modelos Estruturais , Imagens de Fantasmas , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...