Bioanalysis ; 7(20): 2701-12, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26505555

RESUMO

BACKGROUND: An assay measuring an IgG4 biotherapeutic in human serum used a drug-specific monoclonal antibody (mAb) capture reagent and an antihuman IgG4 mAb as detection reagent. However, serum IgG4 binding to the capture mAb via Fc-interactions was detected by the anti-IgG4 mAb, causing high background. RESULTS: Two approaches were developed to minimize background; incorporating a mild acid sample preparation step or using the Fab of the capture antibody. Either strategy improved signal:noise dramatically, increasing assay sensitivity >20-fold. Biophysical analyses of antibody domains indicated that noncovalent Fc oligomers could inhibit the background. CONCLUSION: Matrix interference from human IgG4 binding to the capture mAb was reduced with a Fab fragment of the drug-specific capture antibody or by incorporating a mild acid sample treatment into the assay.


Assuntos
Fragmentos Fc das Imunoglobulinas/metabolismo , Imunoglobulina G/sangue , Animais , Anticorpos Monoclonais/imunologia , Anticorpos Neutralizantes/imunologia , Cromatografia em Gel , Eletroforese em Gel de Poliacrilamida , Ensaio de Imunoadsorção Enzimática , Haplorrinos , Humanos , Fragmentos Fab das Imunoglobulinas/imunologia , Fragmentos Fab das Imunoglobulinas/metabolismo , Fragmentos Fc das Imunoglobulinas/genética , Imunoglobulina G/imunologia , Camundongos , Eletroforese em Gel de Poliacrilamida Nativa , Ligação Proteica