Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(16)2023 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-37631692

RESUMO

A three-dimensional motion capture system (MoCap) and the Garmin Running Dynamics Pod can be utilised to monitor a variety of dynamic parameters during running. The present investigation was designed to examine the validity of these two systems for determining ground contact times while running in place by comparing the values obtained with those provided by the bilateral force plate (gold standard). Eleven subjects completed three 20-s runs in place at self-selected rates, starting slowly, continuing at an intermediate pace, and finishing rapidly. The ground contact times obtained with both systems differed significantly from the gold standard at all three rates, as well as for all the rates combined (p < 0.001 in all cases), with the smallest mean bias at the fastest step rate for both (11.5 ± 14.4 ms for MoCap and -81.5 ± 18.4 ms for Garmin). This algorithm was developed for the determination of ground contact times during normal running and was adapted here for the assessment of running in place by the MoCap, which could be one explanation for its lack of validity. In conclusion, the wearables developed for monitoring normal running cannot be assumed to be suitable for determining ground contact times while running in place.


Assuntos
Captura de Movimento , Corrida , Humanos , Algoritmos , Placas Ósseas
2.
Sensors (Basel) ; 22(13)2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35808391

RESUMO

A novel wearable smart patch can monitor various aspects of physical activity, including the dynamics of running, but like any new device developed for such applications, it must first be tested for validity. Here, we compare the step rate while running in place as measured by this smart patch to the corresponding values obtained utilizing ''gold standard'' MEMS accelerometers in combination with bilateral force plates equipped with HBM load cells, as well as the values provided by a three-dimensional motion capture system and the Garmin Dynamics Running Pod. The 15 healthy, physically active volunteers (age = 23 ± 3 years; body mass = 74 ± 17 kg, height = 176 ± 10 cm) completed three consecutive 20-s bouts of running in place, starting at low, followed by medium, and finally at high intensity, all self-chosen. Our major findings are that the rates of running in place provided by all four systems were valid, with the notable exception of the fast step rate as measured by the Garmin Running Pod. The lowest mean bias and LoA for these measurements at all rates were associated consistently with the smart patch.


Assuntos
Corrida , Adulto , Exercício Físico , Teste de Esforço , Humanos , Monitorização Fisiológica , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...