Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Technol ; 35(13-16): 1611-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24956751

RESUMO

An assessment of a decentralized inductively heated plasma waste treatment system for energy recovery has been done. The modular miniaturized high enthalpy plasma source IPG6 is a reference for the system and has been qualified for inert but also chemically aggressive gas compositions. An identification and review of applications were undertaken. Niches of high environmental and societal importance are considered: hospital waste (threshold countries), shipboard waste and marine litter. The wastes are reviewed deriving relevant parameter for a system analysis aiming for the derivation of energy production and efficiencies. The system analysis shows advantageous constellation due to the wastes' energy leading to self-feeding systems.


Assuntos
Fontes Geradoras de Energia , Gerenciamento de Resíduos , Gases em Plasma
2.
ASAIO Trans ; 35(3): 708-12, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2597571

RESUMO

The time that blood elements remain in an artificial ventricle determines the period during which these blood elements are exposed to damaging factors. We present, for the first time, preliminary studies on the residence time distribution (RTD) of a ventricle as a function of type and orientation of valves (Bjork-Shiley and polyurethane valves). We constructed an open loop mock circulation system which simulates the flow and pressure through the left ventricle, and a drive triggered injection unit which can inject a chemical tracer or radioisotope during one diastolic filling phase. RTD studies were done using a Tc-99m radionuclide tracer and a chemical tracer. A scintillation camera clearly showed the influence of backflow through the artificial heart valves, and the intraventricular washout. Results indicate that 42% of the fluid elements are expelled at the end of the first ventricular beat, i.e., 58% of blood elements stayed behind to experience the second beat; 36% of blood elements expelled in the second beat belonged to those in the first diastole; 17% in the third beat; and 5% in a subsequent number of beats. The RTD was found to vary with the position of the Bjork-Shiley (BS) valves.


Assuntos
Débito Cardíaco/fisiologia , Coração Auxiliar , Função Ventricular , Velocidade do Fluxo Sanguíneo , Diástole/fisiologia , Desenho de Equipamento , Próteses Valvulares Cardíacas , Humanos , Modelos Cardiovasculares , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...