Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Zhongguo Gu Shang ; 35(11): 1074-80, 2022 Nov 25.
Artigo em Chinês | MEDLINE | ID: mdl-36415195

RESUMO

OBJECTIVE: To explore the early clinical efficacy of primary total hip arthroplasty(THA) with Corail standard stems (KS type) and high offset stems (KHO type), by analyzing the postoperative radiographic parameters of different offset of femoral components with Corail stem which has a neck-shaft angle of 135 ° in unilateral primary THA, by comparing the measurement results on both sides and analyzing the reconstruction of the postoperative femoral offset and the hip joint function recovery. METHODS: A retrospective analysis was made of 186 patients with unilateral hip joint lesions who underwent the first total hip arthroplasty with Johnson & Johnson Corail prostheses from January 2015 to June 2017. According to the use of femoral prostheses with different eccentricities during the operation, the patients were divided into high eccentricity group and standard eccentricity group. In the high eccentricity group, there were 52 cases of Corail high eccentricity prosthesis(KHO type), including 20 females and 32 males;aged 21 to 71 years old with an average of(50.6±13.2) years;body mass index(BMI) was (26.0±4.1) kg/m2. The standard eccentricity group included 134 Corail standard femoral stem prostheses(KS type), 57 females and 77 males;aged 18 to 77 years old with an average of (47.3±14.0) years;BMI was (25.3±3.5) kg/m2. The abduction arm, femoral eccentricity, acetabular eccentricity and the length difference of lower limbs were measured on the postoperatively positive X-ray film of the hip joint. Harris score and related complications were recorded before and after the operation, and the stability of the prosthesis was analyzed. RESULTS: There were significant differences in femoral eccentricity, joint eccentricity and abduction arm between the affected side and the healthy side in the high eccentricity group(P<0.05). There were significant differences in femoral eccentricity and acetabular eccentricity between the affected side and the healthy side in the standard eccentricity group(P<0.05). There were significant differences in combined eccentricity, abduction arm and length of lower limbs between two groups(P<0.05). In the high eccentricity group, the abduction arm of the affected hip joint was positively correlated with the femoral eccentricity, acetabular eccentricity and joint eccentricity(r=0.633, P<0.001;r=0.384, P=0.005;r=0.690, P<0.001). The same results were also obtained in the healthy side(r=0.688, P<0.001;r=0.574, P<0.001;r=0.765, P<0.001). In the standard eccentricity group, the abduction arm of the affected hip joint was positively correlated with the femoral eccentricity, acetabular eccentricity and combined eccentricity(r=0.734, P<0.001;r=0.418, P<0.001;r=0.749, P<0.001). The same results were also obtained in the healthy side(r=0.775, P<0.001;r=0.397, P<0.001;r=0.773, P<0.001). The difference of the length of both lower limbs was significantly correlated with the difference of bilateral joint eccentricity and bilateral abduction arm (r=0.376, P=0.006;r=-0.346, P=0.012). There was no significant correlation between the difference of the length of both lower limbs and the difference of bilateral joint eccentricity and bilateral abduction arm (r=-0.009, P=0.919;r=-0.036, P=0.682). There was no significant difference in Harris score between two groups at the last follow-up(P>0.05). At the last follow-up, Trendelenburg was negative in all patients in both groups, and the prostheses were stable. CONCLUSION: Both Corail standard stem and high offset stem may be effectively reconstruct the femoral offset, reconstruct the anatomical structure and biomechanics of the hip joint, and maintain the length of lower limbs and the stability of the hip joint in the unilateral primary total hip arthroplasty. Although the offset of the femur was not reconstructed normally in some cases, the stability of the components and postoperative function were not affected.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Adolescente , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Fêmur/cirurgia , Extremidade Inferior
2.
World J Clin Cases ; 10(31): 11349-11357, 2022 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-36387798

RESUMO

BACKGROUND: Patellar tendon rupture after total knee arthroplasty (TKA) is a catastrophic complication. Although the occurrence of this injury is rare, it can lead to significant dysfunction for the patient and is very tricky to deal with. There has been no standard treatment for early patella tendon rupture after TKA, and long-term follow-up data are lacking. AIM: To introduce a direct repair method for early patella tendon rupture following TKA and determine the clinical outcomes and complications of this method. METHODS: During the period of 2008 to 2021, 3265 consecutive TKAs were retrospectively reviewed. Twelve patients developed early patellar tendon rupture postoperatively and were treated by a direct repair method. Mean follow-up was 5.7 years. Demographic, operative, and clinical data were collected. The clinical outcomes were assessed using the Western Ontario and McMaster Universities (WOMAC) score, the Hospital for Special Surgery (HSS) score, knee range of motion, extensor lag, and surgical complications. Descriptive statistics and paired t test were employed to analyze the data. RESULTS: For all 12 patients who underwent direct repair for early patellar tendon rupture, 3 patients failed: One (8.3%) for infection and two (17.6%) for re-fracture. The two patients with re-fracture both underwent reoperation to reconstruct the extensor mechanism and the patient with infection underwent revision surgery. The range of motion was 109.2° ± 10.6° preoperatively to 87.9° ± 11° postoperatively, mean extensor lag was 21° at follow-up, and mean WOMAC and HSS scores were 65.8 ± 30.9 and 60.3 ± 21.7 points, respectively. CONCLUSION: This direct repair method of early patellar tendon rupture is not an ideal therapy. It is actually ineffective for the recovery of knee joint function in patients, and is still associated with severe knee extension lag and high complication rates. Compared with the outcomes of other repair methods mentioned in the literature, this direct repair method shows poor clinical outcomes.

3.
World J Clin Cases ; 10(23): 8107-8114, 2022 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-36159530

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) has been shown to improve quality of life and reduce pain. High-flexion activities such as squatting, kneeling, and floor transfers are mainly listed as demanding tasks. Among them, squatting is an important position. AIM: To provide a new squat position classification and evaluate the different squatting positions of a series of patients after primary TKA. METHODS: From May 2018 to October 2019, we retrospectively reviewed 154 video recordings of the squatting-related motions of patients after TKA. Among the included patients, 119 were women and 35 were men. Their mean age at the index surgery was 61.4 years (range, 30 to 77). RESULTS: The median follow-up was 12 mo (range, 6 to 156 mo). We classified those squatting-related motions into three major variations according to squatting depth: Half squat, parallel squat, and deep squat. The angles of hip flexion, knee flexion, and ankle dorsiflexion were measured in the screenshots captured from the videos at the moment of squatting nadir. A total of 26 patients were classified as half squats, 75 as parallel squats, and 53 as deep squats. The angles of hip flexion, knee flexion, and ankle dorsiflexion all differed significantly among the three squatting positions (P < 0.001). In the parallel squat group, the mean knee flexion angle (°) was 116.5 (SD, 8.1; range, 97 to 137). In the deep squat group, the mean knee flexion angle (°) was 132.5 (SD, 9.3; range, 116 to 158). CONCLUSION: Among the three squatting positions, deep squat showed the highest hip, knee, and ankle flexion angles, followed by the parallel squat. With the improvement of squatting ability, the patient's postoperative satisfaction rate was also significantly enhanced. However, the different squatting abilities of the patients cannot be effectively distinguished from the scoring results (P > 0.05). Our squatting position classification offers a pragmatic approach to evaluating patients' squatting ability after TKA.

4.
Zhongguo Gu Shang ; 35(7): 610-4, 2022 Jul 25.
Artigo em Chinês | MEDLINE | ID: mdl-35859368

RESUMO

OBJECTIVE: To investigate the application of high offset femoral stem prosthesis in primary total hip arthroplasty. METHODS: From January 2015 to June 2017, 51 patients with unilateral hip diseases who underwent primary total hip arthroplasty with Corail high offset femoral stem prosthesis(KHO type) were selected for retrospective study, including 20 females and 31 males;the age ranged from 21 to 71 years old with an average of(50.8±13.3) years old. The abduction arm, femoral offset, acetabular offset and the length of lower limbs were measured on the positive X-ray film of hip joint after operation. Harris scores before and after operation and related complications were recorded, and the stability of prosthesis was analyzed. RESULTS: The femoral offset, combined offset and abduction arm of the affected side were significantly greater than those of the healthy side(P<0.05). There was no significant difference in acetabular offset between the affected side and the healthy side (P>0.05). The femoral offset of 17 hips (33.3%) was reconstructed normally, of which 15 cases (88.2%) had equal length of both lower limbs. The femoral offset of 34 hips (66.7%) was greater than that of the healthy side, and 34 cases (100%) had equal length of both lower limbs. All 51 patients were followed up for(42.3±7.3) months. The Harris score increased from 38.0±7.6 before operation to 92.1±3.1 at the final follow-up(P<0.001). CONCLUSION: Although the high offset Corail prosthesis can not normally reconstruct the femoral offset in unilateral primary total hip arthroplasty, it does not affect the reconstruction of the length of lower limbs and the stability of the prosthesis.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Adulto , Idoso , Feminino , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
5.
J Orthop Traumatol ; 22(1): 41, 2021 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-34655357

RESUMO

BACKGROUND: Valgus deformity of the knee remains a complaint after total hip arthroplasty (THA) among some patients with Crowe type IV hip dysplasia. We aimed to identify the knee alignment in these patients before and after surgery, and to explore the factors contributing to postoperative knee valgus alignment. MATERIALS AND METHODS: We retrospectively reviewed a series of Crowe type IV patients who received THA between February 2010 and May 2019 in our hospital. The patients' medical data were collected from the hospital information system. On both preoperative and postoperative full limb length standing radiographs, the following parameters were measured: hip-knee-ankle angle (HKA), mechanical lateral distal femoral angle (mLDFA), medial proximal tibial angle, anatomical tibiofemoral angle, anatomical lateral distal femoral angle, femoral neck-shaft angle, pelvic obliquity, limb length, height and lateral distance of hip center, and femoral offset. Univariate and multivariate binary logistic regression were used to identify the factors influencing postoperative knee valgus alignment. RESULTS: A total of 64 Crowe type IV patients (87 hips) were included in the study. Overall, HKA improved from 176.54 ± 3.52° preoperatively to 179.45 ± 4.31° at the last follow-up. Those hips were subdivided into non-valgus group (≥ 177.0°, n = 65) and valgus group (< 177.0°, n = 22) according to postoperative HKA. Only postoperative mLDFA was a significant factor in the multivariate regression model. CONCLUSIONS: The postoperative mLDFA is a major factor related to knee valgus alignment after THA, which combines the preoperative anatomy and surgical reconstruction. Other factors previously published were found to have no significance. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia de Quadril , Luxação Congênita de Quadril , Luxação do Quadril , Osteoartrite do Joelho , Fêmur/cirurgia , Luxação Congênita de Quadril/cirurgia , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos
6.
Orthop Surg ; 13(6): 1787-1792, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34351063

RESUMO

OBJECTIVE: To evaluate the predictive values of femoral proximal medullary morphology for the use of subtrochanteric osteotomy (STO) in unilateral Crowe IV developmental dysplasia of the hip (DDH). METHODS: Ninety four patients with unilateral Crowe type IV DDH (59 hips in STO group and 35 hips in the non-STO group) between April 2008 and June 2019 were enrolled. All patients underwent THA using the Pinnacle acetabular shell, ceramic liner and femoral head, the S-ROM stem with proximal sleeve. Three parameters on the standard anteroposterior hip radiographs were measured: the widths of medullary canals at 20 mm above the center of lesser trochanter (CLT),20 mm below the CLT and the isthmus. Canal flare index (CFI), metaphyseal canal flare index (MCFI), diaphyseal canal flare index (DCFI) were calculated. A S-ROM femoral stem was used in all patients during total hip arthroplasty (THA). RESULTS: The CFI and DCFI in the STO group were lower than those in the non-STO group. However, there was no statistical difference in MCFI between the two groups. The receiver operating characteristic (ROC) curves shown that DCFI had the highest area under the curve (AUC), at 0.885. This was followed by the CFI, which had an AUC of 0.847. The AUC of MCFI was 0.579. The optimal threshold for DCFI was 1.44, which lead to a sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 0.771, 0.898, 0.869, and 0.818, respectively. For CFI, the optimal threshold was 3.28, resulting in a sensitivity, specificity, PPV, and NPV of 0.829, 0.729, 0.878, and 0.644, respectively. CONCLUSIONS: The DCFI and CFI may be potent indicators in predicting the use of STO in unilateral Crowe IV DDH. The optimal threshold for CFI and DCFI were 3.28 and 1.44 and had good sensitivity and specificity for predicting the use of STO during THA.


Assuntos
Artroplastia de Quadril/métodos , Fêmur/cirurgia , Luxação Congênita de Quadril/cirurgia , Prótese de Quadril , Osteotomia/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
7.
ANZ J Surg ; 91(9): 1903-1907, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34374494

RESUMO

BACKGROUND: We aimed to analyze if the false acetabulum is a good indicator for determining femoral shortening. METHODS: We retrospectively included 102 patients with unilateral Crowe type IV developmental dysplasia who underwent primary total hip arthroplasty from April 2008 to May 2019. Based on the presence of false acetabulum, the 102 hips were further classified Crowe IVA group and Crowe IVB group. Radiographic measurement included the height of greater trochanter (HGT) preoperatively and postoperatively, which reflected the distalisation of greater trochanter (DGT). Harris hip score (HHS), limb length discrepancy (LLD), and complications were collected as clinical evaluation. RESULTS: Sixty hips were classified into Crowe IVA group, and 42 hips were classified into Crowe IVB group. Within Crowe IVA group, the proportion of hips treated with subtrochanteric osteotomy was significantly higher than that in Crowe IVB group (97% vs. 12%) (P < 0.001). The DGT in Crowe IVA group was also greater (67 vs. 32 mm) (P < 0.001). At last follow-up, both two groups obtained excellent clinical scores. There was no significant difference in postoperative LLD between the two groups (P = 0.001). Six dislocations occurred and three patients developed femoral nerve palsy, while all recovered in a year. CONCLUSION: The false acetabulum is a promising and good indicator for determining femoral shortening.


Assuntos
Artroplastia de Quadril , Luxação Congênita de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/cirurgia , Humanos , Estudos Retrospectivos
8.
World J Clin Cases ; 9(22): 6300-6307, 2021 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-34434996

RESUMO

BACKGROUND: Utilizing the large jumbo cup in revision total hip arthroplasty is an effective approach to cure many lacunar and segmental peripheral bone defects. However, with the use of the jumbo cup, the center of the hip joint may become elevated relative to the primary acetabulum, and the diameter of the large cup is greater. AIM: To study the height and the significance of the elevation of the hip joint center. METHODS: Eighty-eight patients matched the criteria for this condition and were included in the study. The center height of the hip joint was measured relative to the opposite normal hip joint. The diameter of the jumbo cup was measured and checked according to operation notes, and the diameter of the jumbo cup was measured with a prosthesis label. Then, the horizontal and vertical centers of rotation were measured on the surgical side and opposite side. The average center height of the hip joint on the renovated side and the opposite side and the position of the hip cup relative to the teardrop were compared using a paired t-test. RESULTS: Radiometric analysis showed that the average hip joint center was elevated by 7.6 mm. The rotational center height delta of the renovated hip was 7.6 ± 5.6 mm, and there was an obvious difference between the two groups (P = 0.00). The difference in horizontal distance was 0.5 ± 5.1 mm (-11.5 -14.0 mm), and there was no obvious difference between the two groups (P = 0.38). According to the foreign standard, the rotational center height delta of the renovated hip was 7.5 ± 6.2 mm, and there was a significant difference between the two groups (P = 0.00). There was no obvious difference between the domestic and foreign standards (P > 0.05) between the two groups. CONCLUSION: The application of the jumbo cup elevates the rotational center of the hip joint, but it is feasible and effective to use the jumbo cup.

9.
Orthop Surg ; 13(2): 546-552, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33619848

RESUMO

OBJECTIVE: To investigate variation of the pelvis in unilateral Crowe type IV developmental dysplasia of the hip (DDH) and analyze the reliability of pelvic landmarks. METHODS: We retrospectively received preoperative anteroposterior pelvic radiographs for 89 adult patients with unilateral Crowe type IV DDH at our institution between September 2008 and May 2019. Forty-eight patients without a false acetabulum was type IVA and 41 with a false acetabulum was type IVB. The heights of the ilium, acetabulum, and ischium areas in affected and unaffected sides were measured. The ratios of the three areas in entire pelvis are calculated. The discrepancies of bilateral iliac crest, inferior sacroiliac articulation, teardrop, and ischial tuberosity on the bisector of the pelvis were also measured. RESULTS: The mean heights of the ilium, acetabulum, ischium areas in the affected side were 74.4, 88.6, and 37.0 mm, respectively, in type IVA group and 77.7, 83.5, and 37.8 mm, respectively, in type IVB group. The heights in the unaffected side were 82.1, 84.6, and 43.8 mm, respectively, in type IVA group and 84.6, 82.0, and 44.0 mm, respectively, in type IVB group. The ratios of the ilium, acetabulum, ischium areas in affected side of Crowe type IVA group were 0.37, 0.44, and 0.19, respectively, and the ratios in unaffected side were 0.39, 0.40, and 0.21, respectively. The ratios in affected side of Crowe type IVB group were 0.39, 0.42, and 0.19, respectively, and the ratios in unaffected side were 0.40, 0.39, and 0.21, respectively. The discrepancies of bilateral iliac crest, inferior sacroiliac articulation, teardrop, and ischial tuberosity on the line of the bisector of the pelvis in Crowe type IVA group were 5.6, 5.2, 2.0, and 7.1 mm, respectively. Those in Crowe type IVB group were 8.1, 3.5, 3.5, and 4.9 mm, respectively. CONCLUSIONS: Pelvic asymmetry was a common occurrence in unilateral Crowe type IV DDH in adults. Furthermore, it should be reliable to use teardrop as pelvic landmark to balance leg length discrepancy in preoperative planning.


Assuntos
Pontos de Referência Anatômicos , Displasia do Desenvolvimento do Quadril/diagnóstico por imagem , Desigualdade de Membros Inferiores/diagnóstico por imagem , Ossos Pélvicos/diagnóstico por imagem , Adulto , Displasia do Desenvolvimento do Quadril/fisiopatologia , Displasia do Desenvolvimento do Quadril/cirurgia , Feminino , Humanos , Desigualdade de Membros Inferiores/fisiopatologia , Desigualdade de Membros Inferiores/cirurgia , Masculino , Pessoa de Meia-Idade , Ossos Pélvicos/anormalidades , Ossos Pélvicos/fisiopatologia , Ossos Pélvicos/cirurgia , Radiografia , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
J Orthop Surg Res ; 16(1): 149, 2021 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-33610184

RESUMO

BACKGROUND: Knee osteoarthritis associated with extra-articular deformity (EAD) can confront the arthroplasty surgeons with challenges of bone resection and soft tissue balancing. The aim of this study was to describe a single-stage procedure associating corrective osteotomy with total knee arthroplasty (TKA), and to determine the outcome at mid- to long-term follow-up. METHODS: A total of seven patients (seven knees) with knee osteoarthritis and supracondylar deformity were included in this study. Six patients were female, and one was male, with the median age of 62 years (range, 37-76 years). All patients were treated with single-stage TKA and femoral osteotomy. Osteotomy was fixed with long cemented stem. Hospital of Special Surgery (HSS) scores, collateral ligament laxity, and range of motion (ROM) were clinically evaluated preoperatively and at each follow-up. Radiographic parameters including the mechanical axis deviation (MAD), mechanical lateral distal femoral angle (mLDFA), mechanical proximal tibial angle (mMPTA), and joint line congruence angle (JLCA) were also measured. The occurrence of perioperative complications was recorded. RESULTS: The median follow-up time was 91 months (range, 38-104 months). At the last follow-up, all components were stable and no patients required revision. Nonunion of the osteotomy occurred in one patient. In all patients, the lower limb mechanical alignment improved greatly. The mean angle of MAD was restored from 10.49±6.05 cm preoperatively to 1.11±4.97 cm postoperatively. The 90° mLDFA was almost acquired in all cases, with the postoperative value of 90.79±2.40°. After operation, the mMPTA improved from 84.18±6.13° to 91.33±3.13°. The JLCA changed from 2.94±1.61° to -0.71±3.50°. The median HSS score improved from 45 (range, 34-56) preoperatively to 90 (range, 82-97) postoperatively, with the outcome of all patients rated good to excellent. The median ROM improved from 70° (range 0-110°) preoperatively to 105° (range 90-125°) postoperatively. No instability of knee joint was observed. Complications included an intraoperative split fracture of distal femur and one case of wound exudation resulting from fat liquefaction. CONCLUSIONS: For knee osteoarthritis with femoral supracondylar deformity, single-stage TKA and corrective osteotomy was feasible but technically demanding. The use of long cemented stem for osteotomy fixation can provide reliable rotational control of the bone segments.


Assuntos
Artroplastia do Joelho/métodos , Fêmur/cirurgia , Deformidades Articulares Adquiridas/cirurgia , Osteoartrite do Joelho/cirurgia , Osteotomia/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
11.
Ann Palliat Med ; 10(5): 5818-5824, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32921067

RESUMO

Pseudotumor is a rare complication following total hip arthroplasty (THA) with ceramic-on-metal (CoM) bearings. There is still in controversy about the using of CoM bearings when conducting surgery. We reported a case of a 47-year-old woman who underwent cementless CoM bearing THA because of left Crowe type III dislocation of the hip (DDH) in December 2009. One year after THA, she presented at our hospital complaining of crunching noise, pain, and decreased level of function. A revision surgery was performed because of left hip instability in December 2010, we adjusted the excessive anteversion of stem and replaced the head by using the long-neck ceramic head. In February 2019, she was admitted to our hospital complaining of repeated dislocation and fracture of greater trochanter. During the re-revision surgery, a pseudotumor and grey synovial sac were revealed. The metal liner was replaced with a ceramic liner and the greater trochanter was reattached using the Cable-Ready system. Clinical outcome was successful at 6 months postoperatively. This case vividly demonstrated CoM bearing should be avoided in THA. The pseudotumor highly destructed the periprosthetic soft tissues and the bone, which leaded to dislocation and periprosthetic fracture. The surgeon should be aware of the complication so that prompt diagnosis and treatment can be performed.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Cerâmica , Feminino , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Pessoa de Meia-Idade , Falha de Prótese , Fatores de Risco , Resultado do Tratamento
12.
Patient Prefer Adherence ; 14: 2469-2475, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33364752

RESUMO

PURPOSE: The study assessed the correlation among the patients' perception of leg length discrepancy (LLD) after total hip arthroplasty (THA) in patients with unilateral Crowe type IV developmental dysplasia of the hip (DDH) and the four methods of measuring the leg length in the full-length standing anteroposterior radiographs. METHODS: Sixty patients with unilateral Crowe type IV DDH were recruited in this retrospective study between January 2012 and January 2019. Four methods of measurement were used: 1) TD-TP: distance between the inferior aspect of teardrop (TD) and the midpoint of tibial plafond (TP); 2) CH-TP: distance between the center of the hip (CH) or acetabular cup and the TP; 3) GT-TP: distance between the apex of greater trochanter (GT) and the TP; and 4) FL+TL: the sum of femoral length (FL) and tibial length (TL). RESULTS: Association was found among the patients' perception on LLD with difference in TD-TP (OR=1.157), and the difference in FL+TL (OR=1.166). The area under the curve of the difference in FL+TL and the difference TD-TP (0.704 and 0.679) was significantly higher than those of the difference in CH-TP and the difference in GT-TP (0.564 and 0.483). With the calculated threshold of LLD set at 9.0 mm, the sensitivity and specificity of the difference in TD-TP and the difference in FL+TL were 57.7%, 79.4% and 61.5%, 79.4%, respectively. CONCLUSION: Patients' perception on LLD had good correlation and reliability on the difference of FL+TL and the difference of TD-TP on both sides in the full-length standing anteroposterior radiographs after THA in patients with unilateral Crowe type IV DDH. The calculated threshold of the difference in FL+TL and the difference in TD-TP was set at 9.0 mm to assess the patients' perception on LLD.

13.
Orthop Surg ; 12(6): 1913-1922, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33185022

RESUMO

OBJECTIVE: The aim of the present paper was to evaluate the results of one-stage total hip arthroplasty (THA) for patients with bilateral Crowe type IV developmental dysplasia of the hip (DDH). METHODS: Data for 58 patients (116 hips) with bilateral Crowe type IV DDH who had one-stage THA performed by the same surgeon during the period of April 2008 to February 2019 were retrospectively reviewed. The mean age of the patients was 37.3 years; 5 were men and 53 were women. All patients underwent THA through the posterolateral approach using the Pinnacle acetabular cup, a ceramic-on-ceramic bearing, and the modular S-ROM stem. Subtrochanteric shortening osteotomy was performed on 86/116 hips. Intraoperative conditions were recorded. Radiographic and functional outcomes were evaluated, and complications were recorded. RESULTS: All patients were followed up for an average of 71.3 ± 37.6 months (range, 12-140). The mean operative time was 276.5 ± 57.9 min (range, 175-540). The mean intraoperative blood loss was 933.6 ± 400.8 mL (range, 300-2000). The mean transfusion requirement was 1778 ± 798.0 mL (range, 575-4550). The mean length of hospital stay was 8.6 ± 3.7 days (range, 5-22). At the final follow-up, no loosening of acetabular and femoral components was observed. No osteolysis and heterotopic ossification occurred. The mean Harris hip scores were improved from 55.4 ± 14.3 preoperatively to 91.3 ± 4.2 postoperatively (P < 0.001) In terms of complications, no perioperative deaths were recorded. Deep vein thrombosis occurred in 1 hip, with no pulmonary embolism. Intraoperative femur fracture occurred in 3 hips, nerve injury in 1 hip, and leg length discrepancy in 1 patient. Postoperative dislocation occurred in 5 hips and nonunion in 1 hip. CONCLUSION: Our data demonstrated that one-stage bilateral THA for bilateral Crowe type IV DDH is feasible and can effectively restore hip function.


Assuntos
Artroplastia de Quadril/métodos , Luxação Congênita de Quadril/cirurgia , Prótese de Quadril , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Adolescente , Adulto , Idoso , Artroplastia de Quadril/instrumentação , Avaliação da Deficiência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
14.
Orthop Surg ; 12(6): 1784-1791, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33063440

RESUMO

OBJECTIVE: To describe the technique of primary repair of medial collateral ligament (MCL) insufficiency using a screw and rectangular spiked washer in a case series of 14 patients. METHODS: Fourteen patients undergoing MCL repair by a screw and rectangular spiked washer during TKA between March 2018 and March 2019 were retrospectively reviewed. Among them, half injuries were avulsion of the femoral origin, and the other half were MCL laxity. There were 12 women and two men included in the study, with an average age of 63.6 years (range, 49-79 years) at the time of surgery. This series were followed up with a focus on range of motion (ROM), coronal alignment, Hospital for Special Surgery (HSS) knee scores, their subjective sense of joint instability, and related complications. At the last follow-up, function of the MCL was assessed by manually applying a valgus stress to the knee at both 0° and 30° of knee flexion. RESULTS: The mean follow-up time for all patients was 15.6 months (range, 13-20 months). Repair of the MCL was successful in all patients. ROM improved from a mean of 70.7° ± 35.1° before surgery to 103.9° ± 6.8° at latest follow-up (P = 0.001). All patients were able to perform a half squat easily, but none were able to do full squatting. The mean preoperative HSS score was 43.6 ± 13.4 and increased to a mean of 85.6 ± 3.8 postoperatively (P < 0.001). The femorotibial angle improved from a mean of -3.22° ± 9.47° before surgery to a mean of 5.16° ± 3.14° at the final follow-up (P = 0.006). At the time of final follow-up, no patient required revision and manipulation under anesthesia following the index arthroplasty. No radiolucencies or migration were observed in association with the knee prostheses. No displacement of the screw and rectangular spiked washer was found. There were no clinical complications. No patient reported subjective instability of the knee. Upon physical examination, no patient was found to have laxity in the coronal plane in either 30° of flexion or full extension. CONCLUSIONS: The screw and rectangular spiked washer is a simple and effective method for treating MCL sufficiency in TKA, and a study with a larger cohort and extended follow-up is requisite to claim its role in preventing coronal instability and component failure.


Assuntos
Artroplastia do Joelho/métodos , Parafusos Ósseos , Instabilidade Articular/cirurgia , Ligamento Colateral Médio do Joelho/cirurgia , Idoso , Artroplastia do Joelho/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Estudos Retrospectivos , Inquéritos e Questionários
15.
Biomed Res Int ; 2020: 3718705, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33123571

RESUMO

BACKGROUND: The screw and cement technique is a convenient method used to rebuild medial tibial plateau defects in primary total knee arthroplasty (TKA). The objective of this study was to perform a finite element assessment to determine the effect of different numbers of screws on the stability of TKA and to determine whether differences exist between two different insertion angles. METHOD: Six tibial finite element models with defects filled with screws and cement and one model with defects filled only with cement were generated. Contact stresses on the surface of cancellous bone in different areas were calculated. RESULTS: Compared to the cement-only technique, the stress on the border of cancellous bone and bone cement decreased by 10% using the screw and cement technique. For bone defects with a 12% defect area and a 12-mm defect depth, the use of 1 screw achieved the greatest stability; for those with a 15% defect area and a 20-mm defect depth, 2 screws achieved the greatest stability. CONCLUSIONS: (1) The screw and cement technique is superior to the bone cement-only technique. For tibial defects in which the defect area comprises a large percentage but the depth is less than 5 mm, the screw and cement technique is recommended. (2) Vertical screws can achieve better stability than oblique screws. (3) Screws should be used in moderation for different defects; more is not always better.


Assuntos
Artroplastia do Joelho/métodos , Cimentos Ósseos/uso terapêutico , Parafusos Ósseos , Análise de Elementos Finitos , Humanos , Articulação do Joelho/cirurgia , Masculino , Tíbia/cirurgia
16.
Med Sci Monit ; 26: e926239, 2020 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-33099571

RESUMO

BACKGROUND Indications for subtrochanteric shortening osteotomy (SSOT) during Crowe type IV developmental dysplasia of the hip (DDH) are unclear. The aim of this retrospective study was to create a model to predict the need for performing SSOT. MATERIAL AND METHODS One hundred forty-nine patients (186 hips) with Crowe Type IV DDH who underwent total hip arthroplasty (THA) with S-ROM implants from January 2010 to November 2018 were included in the study. The acetabular components were placed at the true acetabulum and the trial femoral component was inserted. Reduction then was attempted and if it could not be achieved, SSOT was performed. Using multivariable Cox regression analysis, a model was constructed that included age, sex, surgical history, use of a cone- or triangle-shaped sleeve, secondary acetabulum formation, and percentage of dislocation as predictive factors for SSOT. RESULTS SSOTs were performed on 140 of 186 hips. Secondary acetabulum formation was present in 27 hips (58.70%) in which SSOT was not performed 7 (5.00%) in which it was performed. Cone-shaped sleeves were used in 17 hips (36.96%) in which SSOT was not performed versus 15 (10.71%) hips in which it was performed. Dislocation occurred in 31.30±5.80% hips in which SSOT was performed versus 24.05±4.39% of those in which it was not performed. Percentage of dislocation was associated with an increased likelihood of SSOT (odds ratio [OR] 1.24, 95% confidence interval 1.11-1.38), whereas secondary acetabulum formation (OR 0.10, 0.03-0.33) and use of a cone-shaped sleeve (0.18, 0.06-0.53) were associated with decreased likelihood of SSOT. We established a model for prediction of SSOT with a nanogram and the discriminative ability (C statistic) of it was 0.918 (0.79-0.92). CONCLUSIONS Factors that significantly affect likelihood of performing an SSOT were identified and a model with significant ability to predict the need for SSOT in patients with Crowe Type IV DDH was created.


Assuntos
Artroplastia de Quadril/efeitos adversos , Displasia do Desenvolvimento do Quadril/cirurgia , Osteotomia/métodos , Complicações Pós-Operatórias/cirurgia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
17.
J Orthop Surg Res ; 15(1): 184, 2020 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-32448363

RESUMO

BACKGROUND: The acetabular distraction technique demonstrates encouraging radiographic and clinical outcomes in treating chronic pelvic discontinuity. The aim of this study is to describe a modified distraction technique and to show our results. METHODS: This study identified 12 cases of chronic pelvic discontinuity undergoing primary or revision total hip arthroplasty (THA) with the technique of reverse reaming distraction between July 2015 and November 2018. All 12 patients had a minimum follow-up of 12 months. Radiographs were reviewed to inspect for component loosening. Clinical assessment included the Harris hip score (HHS) and an ambulatory scoring system. RESULTS: At the time of final follow-up, no patient was revised. One patient had up to 1 cm migration of the cup in a horizontal or vertical direction and more than 20° change in the abduction angle but was asymptomatic. In the remaining 11 patients, no migration of the component was detected. Both the HHS and ambulatory score showed improvement in all patients. There were no perioperative complications. No postoperative dislocation occurred. CONCLUSIONS: Reverse reaming distraction is a feasible technique in treatment of chronic pelvic discontinuity, with encouraging results at early term. However, ongoing follow-up is required to determine the long-term prognosis in patients receiving this technique.


Assuntos
Acetábulo/anormalidades , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Procedimentos de Cirurgia Plástica/métodos , Acetábulo/diagnóstico por imagem , Adulto , Idoso , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ossos Pélvicos/anormalidades , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/cirurgia , Desenho de Prótese
18.
World J Clin Cases ; 8(7): 1223-1231, 2020 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-32337196

RESUMO

BACKGROUND: Paprosky type IIIB acetabular bone defects are very difficult to reconstruct. For severe defects, we developed our own cup-on-cup technique. We defined the tantalum metal (TM) revision shell with the peripheral titanium ring removed as a TM-cup augment and the cementless hemispherical acetabulum component combined with a TM-cup augment as the cup-on-cup technique. AIM: To report the short-term results of patients with type IIIB acetabular bone defects reconstructed using the cup-on-cup technique. METHODS: We retrospectively reviewed six patients (six hips) with a mean age of 59 years who underwent acetabular reconstruction using our cup-on-cup technique between January 2015 and January 2017. All acetabular bone defects were classified as type IIIB without pelvic discontinuity using the system of Paprosky. All patients were followed both clinically and radiographically for a mean duration of 42 mo. RESULTS: The mean Harris hip score improved from 32.4 pre-operatively to 80.7 at the last follow-up. The mean vertical position of the hip rotation centre changed from 60.9 mm pre-operatively to 31.7 mm post-operatively, and the mean horizontal position changed from 33.6 mm pre-operatively to 38.9 mm post-operatively. Greater trochanteric migration after extended trochanteric osteotomy occurred in one of six hips at 3 mo. There was no evidence of component migration at the last follow-up. CONCLUSION: The short-term results suggest that our cup-on-cup technique could be considered an effective management option for Paprosky type IIIB acetabular bone defects without pelvic discontinuity.

19.
Orthop Surg ; 12(3): 749-755, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32237068

RESUMO

OBJECTIVE: To explore the leg length balance in total hip arthroplasty (THA) with shortening subtrochanteric osteotomy (SSTO) or not for unilateral Crowe type IV developmental dysplasia of the hip (DDH) through the evaluation of postoperative full-length anteroposterior radiographs. METHODS: The postoperative radiographs of 60 patients with unilateral Crowe type IV DDH from July 2012 to May 2019 were retrospectively reviewed. All patients underwent THA using the Pinnacle Acetabular Cup system, a ceramic liner and femoral head, and the S-ROM stem with a proximal sleeve or cone. Patients with leg length discrepancy (LLD) < 10 mm were defined as the non-LLD group. To identify differences associated with SSTO, the group was further divided into two groups based on whether the patient underwent SSTO. A total of 48 patients (26 for SSTO and 22 for non-SSTO) were in the non-LLD group. There were 3 male and 45 female patients. The mean age of the patients in the non-LLD group was 39 years. These data, including leg length, femoral length, the height of center of rotation (COR) of the hip, the depth of the sleeve or cone in the femoral medullary canal and the height of the greater trochanter, were measured. RESULTS: In the non-LLD group, the femoral lengths in both SSTO and non-SSTO groups were significantly shorter on the operated side compared with the contralateral side, and the mean discrepancy in the SSTO group was approximately equal to the mean length of the SSTO. The mean height of the COR of the hip on the operated sides in both SSTO and non-SSTO groups was 13.2 mm, and the contralateral sides were 15.2 and 15.5 mm, respectively. The depth of the sleeve or cone in the femoral medullary canal between SSTO and non-SSTO groups was 21.7 and 30.6 mm, respectively. The depth of the sleeve or cone in the SSTO group was negatively correlated with the length of SSTO. The heights of the greater trochanter in the operated and contralateral sides were 5.3 and 16.6 mm in the SSTO group, and 13.2 and 17.2 mm in the non-SSTO group, respectively. CONCLUSIONS: Shortening subtrochanteric osteotomy led to femoral shortening on the operated side for patients with unilateral Crowe type IV DDH. The position of the sleeve or cone should be close to the apex of the greater trochanter to compensate the length of the SSTO. The position of the sleeve or cone without SSTO should be adjusted to make sure that the height of the greater trochanter on the operated side is close to that on the contralateral side.


Assuntos
Artroplastia de Quadril , Displasia do Desenvolvimento do Quadril/cirurgia , Desigualdade de Membros Inferiores/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
World J Clin Cases ; 7(21): 3562-3568, 2019 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-31750338

RESUMO

BACKGROUND: A recurrent valgus deformity was a common complication after total knee arthroplasty (TKA) in patients with valgus deformity. However, re-revision surgery for re-recurrent valgus deformity after revision TKA in patients with valgus deformity before primary TKA was uncommon. CASE SUMMARY: We reported a 72-year-old female patient with two recurrent valgus deformities after TKA for a valgus knee deformity who underwent two revision surgeries to rectify the deformity. In the re-revision surgery, bone defects were successfully reconstructed by the augments and cement in combination with screws and a sleeve. An appropriate neutral alignment of the lower limb was restored by the perfect femoral entry point and the long diaphyseal cementless stem. Adequate fixation of the metaphysis and diaphysis of the femur was obtained by the sleeve and long diaphyseal cementless stem. The patient was pain-free and deformity-free for 2.5 years. CONCLUSION: The management of bone defects, the choice of the stem and the femoral entry point were of vital importance in the revision or re-revision TKA for a recurrent valgus deformity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...