Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Talanta ; 205: 120099, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31450410

RESUMO

Diglycolamide ligands are widely applied in the analysis of radionuclides, especially lanthanides and actinides. They are used in liquid-liquid extraction procedures or in solid-phase extraction sorbents where they are adsorbed on the surface of hydrophobic polymers. The main objective of this study was to synthesize the N,N,N'N'-tetrahexyl diglycolamide with one vinyl terminating group (vTHDGA) for further covalent immobilization on the polystyrene-divinylbenzene polymeric support. The obtained complexing resin (THDGA) was employed for the mechanized sample pretreatment in the Sequential Injection Analysis - Lab-on-Valve (SIA-LOV) flow system for the determination of 239Pu using ICP-MS detection. The analytical procedure was optimized in terms of selectivity towards several other radionuclides and elements forming potentially isobaric interferences in mass spectrometry. For 100 mL volume of sample to be analyzed, the method detection limit (MDL) was 96 mBq L-1 (42 pg L-1). The developed method was employed for the determination of 239Pu in real samples of a nuclear reactor coolant and spent fuel pool water from a nuclear reactor.

2.
J Inorg Biochem ; 188: 29-37, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30119015

RESUMO

[Fe(NO)2] - modified nanoparticles of low-density protein (DNICLDL) can serve as conveyors of iron in the form of stable complexes with ApoB100 protein. As reported recently, in human hepatoma cells DNICLDL significantly increased the total iron content, while showing low toxicity. In the present work, we focused on the effects of internalization of DNIC-modified lipoproteins in macrophages, with special regards to cytotoxicity. DNICLDL was administered to a model macrophage cell line, RAW 264.7. Administration of DNICLDL considerably increased total iron content. High increase of iron was accompanied by moderate toxicity. As shown by in vitro plasmid nicking assay, chelation of iron in the form of DNIC strongly reduced the iron-related reactive oxygen species (ROS) -induced DNA damage. In addition, DNICLDL, plausibly due to its NO-donating activity, did not induce inducible nitric oxide synthase (iNOS) expression, as opposed to other forms of low-density protein (LDL).


Assuntos
Ferro , Lipoproteínas LDL , Macrófagos/metabolismo , Óxidos de Nitrogênio , Animais , Apolipoproteína B-100/química , Apolipoproteína B-100/farmacologia , Ferro/química , Ferro/farmacologia , Lipoproteínas LDL/química , Lipoproteínas LDL/farmacologia , Macrófagos/citologia , Camundongos , Óxidos de Nitrogênio/química , Óxidos de Nitrogênio/farmacologia , Células RAW 264.7
3.
Talanta ; 184: 527-536, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29674079

RESUMO

This work refers to a comparative study of sorbents widely used in determinations of 99Tc such as TEVA resin and Dowex 1. Despite having a similar functional group of quaternary amines, both materials represent different chromatographic methods-extraction (TEVA resin) and anion exchange (Dowex 1)-which provides a diverse range of their properties significant in determination of 99Tc in flow conditions. The comparative tests, carried out in a SIA-LOV (Sequential Injection Analysis-Lab-on-Valve) system combined with mass spectrometric (ICP-MS) detection, considered several factors that are crucial from the standpoint of resin´s utility such as sorption capacity, durability, or selectivity, critical in 99Tc separation from interferences. The developed and optimized analytical procedure based on the application of the TEVA resin provided determinations of 99Tc at minimum detectable limit (MDL) 6.00 mBq L-1 in 50 min and has been successfully employed in analyses of samples from nuclear industrial and research units (reactor coolant and sewage) as well as from the river surrounding the nuclear reactor. The method proved to be sufficient for routine analysis of water samples in accordance with EPA standards. The reliability of the method was confirmed in the analysis of the BH standard provided by the NPL for inter-laboratory proficiency tests. The 99Tc recovery for all real samples was evaluated as 80-100%.

4.
Biofactors ; 44(2): 192-201, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29399922

RESUMO

In view of the interrelations between NO, Fe, and LDL in the cardiovascular system it appears interesting to find out, if the lipoprotein particles undergo the process of iron-nitrosylation, commonly observed for other proteins and what is the biological fate of iron-nitrosylated LDL particles. Iron-nitrosylated LDL preparation containing Fe(NO)2 motif (DNICLDL) was obtained and characterized for the first time. In order to test its interactions with potential target cells, DNICLDL was administered to the hepatoma HepG2 cells. The effects were referred to those induced by native LDL (nLDL) and oxidized LDL (oxLDL) particles. DNICLDL administration considerably increased total iron content in the studied cell line, but did not influence the level of calcein-chelatable ions. DNICLDL was found to be low toxic to cells. The study suggests that DNICLDL might be a potential transducer of iron. © 2017 BioFactors, 44(2):192-201, 2018.


Assuntos
Ferro/metabolismo , Lipoproteínas LDL/farmacologia , Óxidos de Nitrogênio/farmacologia , Cátions Bivalentes , Sobrevivência Celular/efeitos dos fármacos , Espectroscopia de Ressonância de Spin Eletrônica , Fluoresceínas/química , Fluoresceínas/farmacologia , Células Hep G2 , Humanos , Transporte de Íons , Ferro/farmacologia , Quelantes de Ferro/química , Quelantes de Ferro/farmacologia , Lipoproteínas LDL/síntese química , Óxidos de Nitrogênio/síntese química , Transferrina
5.
Talanta ; 169: 216-226, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28411815

RESUMO

90Sr is a widely determined radionuclide for environmental purposes, nuclear waste control, and can be also monitored in coolants in nuclear reactor plants. In the developed method, the ICP-MS detection was employed together with sample processing in sequential injection analysis (SIA) setup, equipped with a lab-on-valve with mechanized renewal of sorbent bed for solid-phase extraction. The optimized conditions of determination included preconcentration of 90Sr on cation-exchange column and removal of different type of interferences using extraction Sr-resin. The limit of detection of the developed procedure depends essentially on the configuration of the employed ICP-MS spectrometer and on the available volume of the sample to be analyzed. For 1L initial sample volume, the method detection limit (MDL) value was evaluated as 2.9ppq (14.5BqL-1). The developed method was applied to analyze spiked river water samples, water reference materials, and also simulated and real samples of the nuclear reactor coolant.

6.
J Radioanal Nucl Chem ; 299(1): 611-619, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26224951

RESUMO

Raising role of the nuclear power industry, including governmental plans for the construction of first nuclear power plant in Poland, creates increasing demand for the uranium-based nuclear fuels. The project implemented by Institute of Nuclear Chemistry and Technology concerns the development of effective methods for uranium extraction from low-grade ores and phosphorites for production of yellow cake-U3O8. The Liqui-Cel® Extra-Flow 2.5 × 8 Membrane Contactor produced by CELGARD LLC (Charlotte, NC) company is the main component of the installation for liquid-liquid extraction applied for processing of post leaching liquors. In the process of membrane extraction the uranyl ions from aqueous phase are transported through the membrane into organic phase. The flow of two phases in the system was arranged in co-current mode. The very important element of the work was a selection of extracting agents appropriate for the membrane process. After preliminary experiments comprising tests of membrane resistivity and determination of extraction efficiency, di(2-ethylhexyl)phosphoric acid was found to be most favourable. An important aspect of the work was the adjustment of hydrodynamic conditions in the capillary module. To avoid the membrane wettability by organic solvent and mixing two phases equal pressure drops along the membrane module to minimize the transmembrane pressure, were assumed. Determination of pressure drop along the module was conducted using Bernoulli equation. The integrated process of extraction/re-extraction conducted in continuous mode with application of two contactors was designed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...