Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Diabetes Ther ; 15(1): 99-110, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37777677

RESUMO

INTRODUCTION: Women are on average diagnosed with diabetes mellitus at later age than men but have higher mortality. As the diagnosis of diabetes mellitus is primarily based on HbA1c, the use of a non-specific reference range and cut point for diabetes mellitus that does not account for gender differences in diabetes could potentially lead to underdiagnosis of diabetes mellitus in women and missed opportunities for intervention. We investigated whether a contributing factor to the later diagnosis in women may be a difference in distribution of HbA1c in premenopausal women versus men of the same age by comparing HbA1c values in men and women across multiple sites in the UK. METHODS: We analysed the HbA1c levels of 146,907 individuals who underwent single testing only and had HbA1c ≤ 50 mmol/mol between 2012 and 2019 in one laboratory (cohort 1). This was replicated in six laboratories with 938,678 individuals tested between 2019 and 2021 (cohort 2). RESULTS: In cohort 1, women < 50 years old had an HbA1c distribution markedly lower than that in men by a mean of 1.6 mmol/mol (p < 0.0001), while the difference in the distribution of HbA1c for individuals aged ≥ 50 years was less pronounced (mean difference 0.9 mmol/mol, p < 0.0001). For individuals under the age of 50, HbA1c in women lagged by up to 10 years compared to men. Similar findings were found in cohort 2. We estimated an additional 17% (n = 34,953) of undiagnosed women aged < 50 years in England and Wales could be reclassified to have diabetes mellitus, which may contribute to up to 64% of the difference in mortality rates between men/women with diabetes mellitus aged 16-50 years. CONCLUSION: The HbA1c cut point for diagnosis of diabetes mellitus may need to be re-evaluated in women under the age of 50 years. Early identification of diabetes mellitus in women has the potential to improve women's health outcomes in the longer term.

3.
Ann Clin Biochem ; 60(6): 367-373, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37158436

RESUMO

BACKGROUND: Laboratories should be aware of the stability of the analytes they are testing in order to avoid incorrect reporting and patient management. Stability studies are difficult to interpret and reproduce, with little guidance on how to determine appropriate clinical cut off values. Here we describe a standardised approach to determining stability for routine haematinics tests using published EFLM guidelines. METHODS: The haematinics panel at UHNM contains vitamin B12, folate, ferritin, iron and transferrin. Blood tubes included were serum separator tubes, gel-free serum and lithium-heparin plasma. Conditions tested were room temperature, 2-8°C and -20°C. For each condition and tube, three samples were analysed in duplicate at 0, 24, 48, 72, 96 and 120 h using the Siemens Atellica platform. RESULTS: The percentage difference was calculated for each respective blood tube and storage condition, in addition to individual analyte maximum permissible instability scores. The majority of analytes for all blood tubes were stable for 5 days or more when stored at 4-8°C and -20°C. Ferritin (excluding gel-free), iron and transferrin further showed stability >5 days when stored at room temperature. However, vitamin B12 and folate demonstrated poor stability data for all tube types tested. CONCLUSIONS: Here we describe a stability study for the haematinics panel on the Siemens Atellica platform using the standardised EFLM Checklist for Reporting Stability Studies (CRESS). The checklist was used in order to promote a standardised and transferable scientific approach to what has previously been lacking in the literature when performing stability experiments.


Assuntos
Brassicaceae , Hematínicos , Humanos , Lista de Checagem , Coleta de Amostras Sanguíneas , Vitamina B 12 , Transferrina , Ácido Fólico , Lítio , Ferritinas , Ferro
4.
Diabetes Ther ; 14(4): 691-707, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36814045

RESUMO

INTRODUCTION: Studies show that the COVID-19 pandemic disproportionately affected people with diabetes and those from disadvantaged backgrounds. During the first 6 months of the UK lockdown, > 6.6 M glycated haemoglobin (HbA1c) tests were missed. We now report variability in the recovery of HbA1c testing, and its association with diabetes control and demographic characteristics. METHODS: In a service evaluation, we examined HbA1c testing across ten UK sites (representing 9.9% of England's population) from January 2019 to December 2021. We compared monthly requests from April 2020 to those in the equivalent 2019 months. We examined effects of (i) HbA1c level, (ii) between-practice variability, and (iii) practice demographics. RESULTS: In April 2020, monthly requests dropped to 7.9-18.1% of 2019 volumes. By July 2020, testing had recovered to 61.7-86.9% of 2019 levels. During April-June 2020, we observed a 5.1-fold variation in the reduction of HbA1c testing between general practices (12.4-63.8% of 2019 levels). There was evidence of limited prioritization of testing for patients with HbA1c > 86 mmol/mol during April-June 2020 (4.6% of total tests vs. 2.6% during 2019). Testing in areas with the highest social disadvantage was lower during the first lockdown (April-June 2020; trend test p < 0.001) and two subsequent periods (July-September and October-December 2020; both p < 0.001). By February 2021, testing in the highest deprivation group had a cumulative fall in testing of 34.9% of 2019 levels versus 24.6% in those in the lowest group. CONCLUSION: Our findings highlight that the pandemic response had a major impact on diabetes monitoring and screening. Despite limited test prioritization in the > 86 mmol/mol group, this failed to acknowledge that those in the 59-86 mmol/mol group require consistent monitoring to achieve the best outcomes. Our findings provide additional evidence that those from poorer backgrounds were disproportionately disadvantaged. Healthcare services should redress this health inequality.

5.
Bipolar Disord ; 25(5): 402-409, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36645255

RESUMO

INTRODUCTION: Blood test monitoring is essential for the management of lithium treatment and National Institute for Health and Care Excellence guidance recommends 6-monthly serum testing of thyroid function. We examined conformity to these guidelines and the impact of monitoring outside these intervals. METHODS: We extracted serum lithium and thyroid hormone results at one centre between January 2009 and December 2020. We identified 266 patients who started lithium during this period with no history of thyroid abnormality within the previous 2 years and were at risk of developing thyroid abnormalities. We examined the interval between tests, time between onset of lithium testing and first thyroid-stimulating hormone (TSH) outside the laboratory reference range and assessed impact of testing outside recommended 6-monthly intervals. RESULTS: The most common testing frequency was 3 months (±1 month), accounting for 17.3% of test intervals. Kaplan-Meier analysis showed that most thyroid dysfunction manifests within 3 years (proportion with abnormal TSH at 3 years = 91.4%, 19.9% of total patients). In the first 3 months after commencing lithium therapy, eight patients developed subclinical hypothyroidism and had clinical follow-up data available. Of these, half spontaneously normalized without clinical intervention. In the remaining patients, thyroxine replacement was only initiated after multiple occasions of subclinical hypothyroidism (median = 2 years after initiating lithium, range: 6 months to 3 years). CONCLUSION: The peak interval at 3 months suggests that thyroid function is frequently checked at the same time as serum lithium, indicating too frequent testing. Our data support the recommended 6-monthly testing interval and highlight poor adherence to it.


Assuntos
Transtorno Bipolar , Hipotireoidismo , Doenças da Glândula Tireoide , Humanos , Lítio/uso terapêutico , Transtorno Bipolar/tratamento farmacológico , Transtorno Bipolar/induzido quimicamente , Hipotireoidismo/tratamento farmacológico , Tireotropina
6.
J Diabetes Res ; 2022: 7093707, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35615258

RESUMO

Aims: We previously showed that the glycated haemoglobin (HbA1c) testing frequency links to diabetes control. Here, we examine the effect of variability in test interval, adjusted for the frequency, on change in HbA1c (ΔHbA1c). Materials & Methods. HbA1c results were collected on 83,872 people with HbA1c results at baseline and 5 years (±3 months) later and ≥6 tests during this period. We calculated the standard deviation (SD) of test interval for each individual and examined the link between deciles of SD of the test interval and ΔHbA1c level, stratified by baseline HbA1c. Results: In general, less variability in testing frequency (more consistent monitoring) was associated with better diabetes control. This was most evident with moderately raised baseline HbA1c levels (7.0-9.0% (54-75 mmol/mol)). For example, in those with a starting HbA1c of 7.0-7.5% (54-58 mmol/mol), the lowest SD decile was associated with little change in HbA1c over 5 years, while for those with the highest decile, HbA1c rose by 0.4-0.6% (4-6 mmol/mol; p < 0.0001). Multivariate analysis showed that the association was independent of the age/sex/hospital site. Subanalysis suggested that the effect was most pronounced in those aged <65 years with baseline HbA1c of 7.0-7.5% (54-58 mmol/mol). We observed a 6.7-fold variation in the proportion of people in the top-three SD deciles across general practices. Conclusions: These findings indicate that the consistency of testing interval, not the just number of tests/year, is important in maintaining diabetes control, especially in those with moderately raised HbA1c levels. Systems to improve regularity of HbA1c testing are therefore needed, especially given the impact of COVID-19 on diabetes monitoring.


Assuntos
Diabetes Mellitus Tipo 2 , Hemoglobinas Glicadas , Diabetes Mellitus Tipo 2/diagnóstico , Hemoglobinas Glicadas/análise , Humanos , Análise Multivariada , Reprodutibilidade dos Testes
7.
J Endocr Soc ; 6(1): bvab180, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34988349

RESUMO

CONTEXT: Adrenal incidentalomas (AIs) are increasingly being identified during unrelated imaging. Unlike AI clinical management, data on referral patterns in routine practice are lacking. OBJECTIVE: This work aimed to identify factors associated with AI referral. METHODS: We linked data from imaging reports and outpatient bookings from a large UK teaching hospital. We examined (i) AI prevalence and (ii) pattern of referral to endocrinology, stratified by age, imaging modality, scan anatomical site, requesting clinical specialty, and temporal trends. Using key radiology phrases to identify scans reporting potential AI, we identified 4097 individuals from 479 945 scan reports (2015-2019). Main outcome measures included prevalence of AI and referral rates. RESULTS: Overall, AI lesions were identified in 1.2% of scans. They were more prevalent in abdomen computed tomography and magnetic resonance imaging scans (3.0% and 0.6%, respectively). Scans performed increased 7.7% year-on-year from 2015 to 2019, with a more pronounced increase in the number with AI lesions (14.7% per year).Only 394 of 4097 patients (9.6%) had a documented endocrinology referral code within 90 days, with medical (11.8%) more likely to refer than surgical (7.2%) specialties (P < .001). Despite prevalence increasing with age, older patients were less likely to be referred (P < .001). CONCLUSION: While overall AI prevalence appeared low, scan numbers are large and rising; the number with identified AI are increasing still further. The poor AI referral rates, even in centers such as ours where dedicated AI multidisciplinary team meetings and digital management systems are used, highlights the need for new streamlined, clinically effective systems and processes to appropriately manage the AI workload.

8.
Endocrinol Diabetes Metab ; 5(2): e00302, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34921531

RESUMO

BACKGROUND: Finger prick blood glucose (BG) monitoring remains a mainstay of management in people with type 2 diabetes (T2DM) who take sulphonylurea (SU) drugs or insulin. We recently examined patient experience of BG monitoring in people with type 1 diabetes (T1DM). There has not been any recent comprehensive assessment of the performance of BG monitoring strips or the patient experience of BG strips in people with T2DM in the UK. METHODS: An online self-reported questionnaire containing 44 questions, prepared following consultation with clinicians and patients, was circulated to people with T2DM. 186 responders provided completed responses (25.5% return rate). Fixed responses were coded numerically (eg not confident = 0 fairly confident = 1). RESULTS: Of responders, 84% were treated with insulin in addition to other agents. 75% reported having had an HbA1c check in the previous 6 months. For those with reported HbA1c ≥ 65 mmol/mol, a majority of people (70%) were concerned or really concerned about the shorter term consequences of running a high HbA1c This contrasted with those who did not know their recent HbA1c, of whom only 33% were concerned/really concerned and those with HbA1c <65 mmol/mol of whom 35% were concerned. Regarding BG monitoring/insulin adjustment, only 25% of responders reported having sufficient information with 13% believing that the accuracy and precision of their BG metre was being independently checked. Only 9% recalled discussing BG metre accuracy when their latest metre was provided and only 7% were aware of the International Standardisation Organisation (ISO) standards for BG metres. 77% did not recall discussing BG metre performance with a healthcare professional. CONCLUSION: The group surveyed comprised engaged people with T2DM but even within this group there was significant variation in (a) awareness of shorter term risks, (b) confidence in their ability to implement appropriate insulin dosage (c) awareness of the limitations of BG monitoring technology. There is clearly an area where changes in education/support would benefit many.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 2 , Glicemia , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hemoglobinas Glicadas , Humanos , Insulina , Insulina Regular Humana
10.
Int J Clin Pract ; 75(9): e14447, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34105863

RESUMO

INTRODUCTION: Women with gestational diabetes (GDM) are at greatly increased risk of type 2 diabetes (T2DM). The UK guidance recommends screening for T2DM at around 6-week postpartum and annually thereafter. We evaluated conformity to this guidance in two separate time periods. METHODS: The proportion of tests performed within guidance was assessed using longitudinal plasma glucose and glycated haemoglobin data in two cohorts (1999-2007, n = 251; 2015-2016, n = 260) from hospital records on women previously diagnosed with GDM. RESULTS: In the 1999-2007 and 2015-2016 cohorts, 59.8% and 35.0% of women had the recommended postpartum testing, respectively (P < .001); just 13.5% and 14.2%, respectively, underwent the first annual test on time. During long-term follow-up of the 1999-2007 cohort (median follow-up: 12.3 years), the proportion of women tested in any given year averaged 34.2% over a 17-year period; there was a progressive decline in the proportion of women receiving a yearly test with time since delivery (P = .002). Over the follow-up period, 85 women from the 1999-2007 cohort developed blood test results in the diabetic range with a median time to presumed DM diagnosis of 5.2 years (range 0.11-15.95 years). Kaplan-Meier analysis showed that 18.8% of women had blood test results in the diabetes range by 5-year postpartum and 37.8% by 10-year postpartum. CONCLUSIONS: Despite high profile guidelines and a clear clinical rationale to screen women with a past diagnosis of GDM, many women did not receive adequate screening for T2DM both in the short term and long term. This suggests that alternative approaches are needed to ensure effective follow-up of this high-risk group. To have an impact, interventions need to be tailored to a young, generally healthy group in which traditional approaches to follow-up may not be best suited.


Assuntos
Diabetes Mellitus Tipo 2 , Diabetes Gestacional , Glicemia , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Gestacional/diagnóstico , Diabetes Gestacional/epidemiologia , Feminino , Teste de Tolerância a Glucose , Humanos , Período Pós-Parto , Gravidez , Estudos Retrospectivos
11.
Cardiovasc Endocrinol Metab ; 10(2): 120-124, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34113798

RESUMO

OBJECTIVE: Accurate diagnosis of polycystic ovarian syndrome (PCOS) enables clinical interventions/cardiometabolic risk factor management. Diagnosis can take over 2 years and multiple clinician contacts. We examined patterns of PCOS-associated biochemical investigations following initial consultation prior to pelvic ultrasound scan (USS). METHODS: We determined in 206 women (i) the range of different biochemical test panels used in the diagnosis of PCOS in primary/secondary care prior to USS relative to national guidance in the UK and (ii) the relation between testing patterns and time to USS to highlight potential delays introduced by inappropriate testing. RESULTS: In these 206 women, 47 different test combinations were requested at initial venepuncture; only 7 (3%) had the test panel suggested in UK guidance (follicle-stimulating hormone/luteinizing hormone/testosterone/sex hormone-binding globulin/prolactin). The number of tests performed prior to USS varied from one test to all seven tests. There was an inverse relation between the number of biochemistry tests requested at initial venepuncture episode and 'time to scan'. Those who had <3 tests had a significantly longer time from first request to USS (median 70 days) than those with 3-7 tests (median 40 days; P = 0.002). One venepuncture episode prior to USS was associated with shorter 'time to scan' (median 29 days) than those with 2-4 episodes (median 255 days; P < 0.001). CONCLUSION: There was no identifiable pattern to biochemical investigations requested as part of the initial diagnostic evaluation in women with suspected PCOS. We recommend standardization of the initial biochemical panel of analytes for PCOS workup, with incorporation into hospital/general practice ordering software systems.

12.
Clin Chem ; 67(8): 1144-1152, 2021 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-34061171

RESUMO

BACKGROUND: The CARdiac MARker Guideline Uptake in Europe (CAMARGUE) program is a multi-country audit of the use of cardiac biomarkers in routine clinical practice. METHODS: An email link to a web-based questionnaire of 30 multiple-choice questions was distributed via the professional societies in Europe. RESULTS: 374 questionnaires were returned from 39 countries, the majority of which were in northern Europe with a response rate of 8.2%-42.0%. The majority of the respondents were from hospitals with proportionately more responses from central hospitals than district hospitals. Cardiac troponin was the preferred cardiac biomarker, evenly split between cardiac troponin T (cTnT) and cardiac troponin I (cTnI). Aspartate transaminase and lactate dehydrogenase are no longer offered as cardiac biomarkers. Creatine kinase, creatine kinase MB isoenzyme, and myoglobin continue to be offered as part of the cardiac biomarker profile in approximately on 50% of respondents. There is widespread utilization of high sensitivity (hs) troponin assays. The majority of cTnT users measure hs-cTnT. 29.5% of laboratories measure cTnI by a non-hs method but there has been substantial conversion to hs-cTnI. The majority of respondents used ng/L and use the 99th percentile as the upper reference limit (71.9% of respondents). A range of diagnostic protocols are in use. CONCLUSIONS: There is widespread utilization of hs troponin methods. A significant minority do not use the 99th percentile as recommended and there is, as yet, little uptake of very rapid diagnostic strategies. Education of laboratory professionals and clinicians remains a priority.


Assuntos
Laboratórios , Troponina T , Biomarcadores , Creatina Quinase Forma MB , Humanos , Troponina I
15.
BMC Psychiatry ; 21(1): 32, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-33435893

RESUMO

BACKGROUND: Bipolar disorder is the fourth most common mental health condition, affecting ~ 1% of UK adults. Lithium is an effective treatment for prevention of relapse and hospital admission, and is widely recommended as a first-line treatment. We previously showed in other areas that laboratory testing patterns are variable with sub-optimal conformity to guidance. We therefore examined lithium results and requesting patterns relative to monitoring recommendations. METHODS: Data on serum lithium levels and intervals between requests were extracted from Clinical Biochemistry laboratory information systems at the University Hospitals of North Midlands, Salford Royal Foundation Trust and Pennine Acute Hospitals from 2012 to 2018 (46,555 requests; 3371 individuals). Data were examined with respect to region/source of request, age and sex. RESULTS: Across all sites, lithium levels on many requests were outside the recommended UK therapeutic range (0.4-0.99 mmol/L); 19.2% below the range and 6.1% above the range (median [Li]: 0.60 mmol/L). A small percentage were found at the extremes (3.2% at < 0.1 mmol/L, 1.0% at ≥1.4 mmol/L). Most requests were from general practice (56.3%) or mental health units (34.4%), though those in the toxic range (≥1.4 mmol/L) were more likely to be from secondary care (63.9%). For requesting intervals, there was a distinct peak at 12 weeks, consistent with guidance for those stabilised on lithium therapy. There was no peak at 6 months, as recommended for those aged < 65 years on unchanging therapy, though re-test intervals in this age group were more likely to be longer. There was a peak at 0-7 days, reflecting those requiring closer monitoring (e.g. treatment initiation, toxicity). However, for those with initial lithium concentrations within the BNF range (0.4-0.99 mmol/L), 69.4% of tests were requested outside expected testing frequencies. CONCLUSIONS: Our data showed: (a) lithium levels are often maintained at the lower end of the recommended therapeutic range, (b) patterns of lithium results and testing frequency were comparable across three UK sites with differing models of care and, (c) re-test intervals demonstrate a noticeable peak at the recommended 3-monthly, but not at 6-monthly intervals. Many tests were repeated outside expected frequencies, indicating the need for measures to minimise inappropriate testing.


Assuntos
Transtorno Bipolar , Lítio , Adulto , Idoso , Transtorno Bipolar/diagnóstico , Transtorno Bipolar/tratamento farmacológico , Humanos , Lítio/uso terapêutico , Compostos de Lítio , Atenção Secundária à Saúde , Reino Unido
17.
J Diabetes Sci Technol ; 15(1): 76-81, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32172590

RESUMO

BACKGROUND: The National Health Service spends £170 million on blood glucose monitoring (BGM) strips each year and there are pressures to use cheaper less accurate strips. Technology is also being used to increase test frequency with less focus on accuracy.Previous modeling/real-world data analysis highlighted that actual blood glucose variability can be more than twice blood glucose meter reported variability (BGMV). We applied those results to the Parkes error grid to highlight potential clinical impact. METHOD: BGMV is defined as the percent of deviation from reference that contains 95% of results. Four categories were modeled: laboratory (<5%), high accuracy strips (<10%), ISO 2013 (<15%), and ISO 2003 (<20%) (includes some strips still used).The Parkes error grid model with its associated category of risk including "alter clinical decision" and "affect clinical outcomes" was used, with the profile of frequency of expected results fitted into each BGM accuracy category. RESULTS: Applying to single readings, almost all strip accuracy ranges derived in a controlled setting fell within the category: clinically accurate/no effect on outcomes areas.However modeling the possible blood glucose distribution in more detail, 30.6% of longer term results of the strips with current ISO accuracy would fall into the "alter clinical action" category. For previous ISO strips, this rose to 44.1%, and for the latest higher accuracy strips, this fell to 12.8%. CONCLUSION: There is a minimum standard of accuracy needed to ensure that clinical outcomes are not put at risk. This study highlights the potential for amplification of imprecision with less accurate BGM strips.


Assuntos
Automonitorização da Glicemia , Diabetes Mellitus Tipo 1 , Glicemia , Humanos , Medicina Estatal
18.
Clin Chim Acta ; 511: 59-66, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33002472

RESUMO

BACKGROUND: The European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) initiated the CArdiac MARker Guidelines Uptake in Europe (CAMARGUE) Study to survey if current biomarker testing for heart failure (HF) in Europe is in accordance with up-dated guidelines. METHODS: A web-based questionnaire was distributed to clinical laboratories via European biochemical societies in 2019. Questions covered the type of natriuretic peptide (NP) assays performed, decision limits for HF, and opinion concerning requirement of different thresholds in patients with renal failure or obesity. RESULTS: There were 347 participating laboratories mostly from European countries with 266 offering NP testing. NP testing was increased from 67% to 77% between 2013 and 2019. NT-proBNP remained the preferred biomarker. Recommended decision limits were implemented for BNP (85%) and better focused for NT-proBNP (40%) than in the previous survey. The survey revealed that laboratorians are willing to support the translation of adjusted cut-off values for age, gender and for patients with conditions like renal insufficiency. CONCLUSION: Guidelines stimulate clinical laboratories to offer NP testing with high value for the diagnosis and management of HF, and to present adjusted medical decision limits. Future guidelines should encourage the use of personalized cut-offs for some confounding factors.


Assuntos
Insuficiência Cardíaca , Laboratórios , Biomarcadores , Europa (Continente) , Insuficiência Cardíaca/diagnóstico , Humanos , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos
19.
Clin Chim Acta ; 508: 267-272, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32454048

RESUMO

BACKGROUND: The CArdiac MARker Guidelines Uptake in Europe Study (CAMARGUE) initiated by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) aims to survey the current use of evidence-based guidelines for dyslipidemia testing in Europe. METHODS: In 2019 a web-based questionnaire was distributed via EFLM National Societies to clinical laboratories in Europe. Questions covered pre-analytics, analytical methods, measurement units, flagging of decision thresholds, and use of decision-enhancing comments. RESULTS: Returns were obtained from 452 laboratories from 28 countries. Most laboratories always use nonfasting blood samples for lipid assays (66%). Lipid profiles are reported in mmol/L by 59% of the laboratories, mainly from 14 countries promoting the use of SI units. Important differences in flagging of decision thresholds were observed, with less than half of the laboratories applying the guideline-recommended LDL cholesterol threshold. Only 17% of the laboratories add an alert comment when familial hypercholesterolemia is suspected and 23% when risk of pancreatitis from hypertriglyceridemia is high. CONCLUSIONS: There are marked differences among laboratories in Europe in terms of pre-analytical, analytical, and post-analytical lipid management that could have an important clinical impact. This relates to different availability of assays or different laboratory practices on reporting and flagging of lipid profiles.


Assuntos
Hiperlipidemias , Laboratórios , Química Clínica , LDL-Colesterol , Europa (Continente) , Humanos
20.
Ann Clin Biochem ; 57(3): 242-245, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32081031

RESUMO

BACKGROUND: United Kingdom national guidelines do not recommend routine testing for thyroid disease in people with type 2 diabetes mellitus (T2DM). However, some studies suggest an increased risk of thyroid dysfunction in T2DM. The aim of this study was to evaluate the current practice of screening for thyroid disease in patients with T2DM. METHODS: Patients with pre-existing T2DM (n = 339) were selected from records for routine glycated haemoglobin testing performed in December 2008. Using routinely collected primary/secondary care data from 2009 to 2017, we examined longitudinal thyroid-stimulating hormone and free thyroxine requests to determine the overall proportion of patients screened for thyroid dysfunction and the time interval between thyroid tests requested. RESULTS: Thirty-three patients (9.7%) had pre-existing thyroid disease. Of the remaining 306 patients, 96.4% had at least one thyroid test during the follow-up period. When the time interval between tests was evaluated in these patients, there was a discrete peak in thyroid function test requests at 12 months, consistent with routine annual testing. Most requests (77%) originated from a general practice setting. CONCLUSIONS: Contrary to current guidelines, we have provided evidence suggestive of regular screening for thyroid dysfunction in patients with T2DM, particularly in general practice. The appropriateness of this practice remains unclear, but may warrant further examination to assess the clinical benefits of screening, balanced against cost.


Assuntos
Diabetes Mellitus Tipo 2/epidemiologia , Doenças da Glândula Tireoide/diagnóstico , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Testes de Função Tireóidea , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...