Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 132(5): 051002, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38364164

RESUMO

We present the measurement of the cosmic ray proton spectrum from 50 TeV to 1.3 PeV using 7.81×10^{6} extensive air shower events recorded by the ground-based GRAPES-3 experiment between 1 January 2014 and 26 October 2015 with a live time of 460 day. Our measurements provide an overlap with direct observations by satellite and balloon-based experiments. The electromagnetic and muon components in the shower were measured by a dense array of plastic scintillator detectors and a tracking muon telescope, respectively. The relative composition of the proton primary from the air shower data containing all primary particles was extracted using the multiplicity distribution of muons which is a sensitive observable for mass composition. The observed proton spectrum suggests a spectral hardening at ∼166 TeV and disfavors a single power law description of the spectrum up to the Knee energy (∼3 PeV).

2.
Phys Rev Lett ; 122(10): 105101, 2019 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-30932668

RESUMO

The GRAPES-3 muon telescope located in Ooty, India records rapid (∼10 min) variations in the muon intensity during major thunderstorms. Out of a total of 184 thunderstorms recorded during the interval of April 2011-December 2014, the one on December 1, 2014 produced a massive potential of 1.3 GV. The electric field measured by four well-separated (up to 6 km) monitors on the ground was used to help estimate some of the properties of this thundercloud, including its altitude and area that were found to be 11.4 km above mean sea level and ≥380 km^{2}, respectively. A charging time of 6 min to reach 1.3 GV implied the delivery of a power of ≥2 GW by this thundercloud that was moving at a speed of ∼60 km h^{-1}. This work possibly provides the first direct evidence for the generation of gigavolt potentials in thunderclouds that could also possibly explain the production of highest-energy (100 MeV) gamma rays in the terrestrial gamma-ray flashes.

3.
Rev Sci Instrum ; 90(2): 023303, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30831735

RESUMO

The Hybrid Photodetector (HPD) is a hybrid unit with a single accelerating gap between a common photocathode and an array of PIN diodes. Customised HPDs with 19 channels were used to detect scintillation light from hadron calorimeter in the Compact Muon Solenoid (CMS) experiment. In this paper, we present results on radiation damage studies carried out on the used HPDs in the outer hadron (HO) and the end-cap hadron (HE) calorimeter of the CMS experiment operating at CERN. The calorimeter is made of alternating layers of scintillating tiles and metals, such as brass or iron. The scintillating light was transmitted to the HPDs by means of optical fibres. Due to excessive exposure to scintillation light and ionising radiation during data taking at the Large Hadron Collider, the performance of the HPDs was expected to degrade significantly in the HE detector. Independent studies on radiation damage of these used photosensors were important to assess the degradation in the performance of the calorimeter. Microscopic scans of relative photon detection efficiencies for two HPDs (one each from HO and HE detector) were made using micron resolution optical scanner. The scanner was specially designed and built for microscopic characterisation of photosensors. Imprints of each fibre (∼1 mm in diameter) on the photocathode with varying damage within the same pixel of the HPD were observed. The localised damage of the photocathode was determined to vary with the amount of scintillation (or calibration) light transmitted by optical fibres to the HPD.

4.
Phys Rev Lett ; 117(17): 171101, 2016 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-27824449

RESUMO

The GRAPES-3 tracking muon telescope in Ooty, India measures muon intensity at high cutoff rigidities (15-24 GV) along nine independent directions covering 2.3 sr. The arrival of a coronal mass ejection on 22 June 2015 18:40 UT had triggered a severe G4-class geomagnetic storm (storm). Starting 19:00 UT, the GRAPES-3 muon telescope recorded a 2 h high-energy (∼20 GeV) burst of galactic cosmic rays (GCRs) that was strongly correlated with a 40 nT surge in the interplanetary magnetic field (IMF). Simulations have shown that a large (17×) compression of the IMF to 680 nT, followed by reconnection with the geomagnetic field (GMF) leading to lower cutoff rigidities could generate this burst. Here, 680 nT represents a short-term change in GMF around Earth, averaged over 7 times its volume. The GCRs, due to lowering of cutoff rigidities, were deflected from Earth's day side by ∼210° in longitude, offering a natural explanation of its night-time detection by the GRAPES-3. The simultaneous occurrence of the burst in all nine directions suggests its origin close to Earth. It also indicates a transient weakening of Earth's magnetic shield, and may hold clues for a better understanding of future superstorms that could cripple modern technological infrastructure on Earth, and endanger the lives of the astronauts in space.

5.
Rev Sci Instrum ; 87(1): 015114, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26827360

RESUMO

Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this article. The proposed design also has the capability of gain stabilization of devices with non-linear thermal response.

6.
Rev Sci Instrum ; 85(2): 023301, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593348

RESUMO

The emergence of high position resolution (∼10 µm) silicon detectors in recent times have highlighted the urgent need for the development of new automated optical scanners of micron level resolution suited for characterizing microscopic features of these detectors. More specifically, for the newly developed silicon photo-multipliers (SiPM) that are compact, possessing excellent photon detection efficiency with gain comparable to photo-multiplier tube. In a short time, since their invention the SiPMs are already being widely used in several high-energy physics and astrophysics experiments as the photon readout element. The SiPM is a high quantum efficiency, multi-pixel photon counting detector with fast timing and high gain. The presence of a wide variety of photo sensitive silicon detectors with high spatial resolution requires their performance evaluation to be carried out by photon beams of very compact spot size. We have designed a high resolution optical scanner that provides a monochromatic focused beam on a target plane. The transverse size of the beam was measured by the knife-edge method to be 1.7 µm at 1 - σ level. Since the beam size was an order of magnitude smaller than the typical feature size of silicon detectors, this optical scanner can be used for selective excitation of these detectors. The design and operational details of the optical scanner, high precision programmed movement of target plane (0.1 µm) integrated with general purpose data acquisition system developed for recording static and transient response photo sensitive silicon detector are reported in this paper. Entire functionality of scanner is validated by using it for selective excitation of individual pixels in a SiPM and identifying response of active and dead regions within SiPM. Results from these studies are presented in this paper.

7.
Rev Sci Instrum ; 83(4): 043301, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22559526

RESUMO

A detailed description of a compact Monte Carlo simulation code "G3sim" for studying the performance of a plastic scintillator detector with wavelength shifter (WLS) fiber readout is presented. G3sim was developed for optimizing the design of new scintillator detectors used in the GRAPES-3 extensive air shower experiment. Propagation of the blue photons produced by the passage of relativistic charged particles in the scintillator is treated by incorporating the absorption, total internal, and diffuse reflections. Capture of blue photons by the WLS fibers and subsequent re-emission of longer wavelength green photons is appropriately treated. The trapping and propagation of green photons inside the WLS fiber is treated using the laws of optics for meridional and skew rays. Propagation time of each photon is taken into account for the generation of the electrical signal at the photomultiplier. A comparison of the results from G3sim with the performance of a prototype scintillator detector showed an excellent agreement between the simulated and measured properties. The simulation results can be parametrized in terms of exponential functions providing a deeper insight into the functioning of these versatile detectors. G3sim can be used to aid the design and optimize the performance of scintillator detectors prior to actual fabrication that may result in a considerable saving of time, labor, and money spent.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...