Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Med Phys ; 51(2): 1019-1033, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37482927

RESUMO

BACKGROUND: Pediatric molecular imaging requires a balance between administering an activity that will yield sufficient diagnostic image quality while maintaining patient radiation exposure at acceptable levels. In current clinical practice, this balance is arrived at by the current North American Consensus Guidelines in which patient weight is used to recommend the administered activity (AA). PURPOSE: We have previously demonstrated that girth (waist circumference at the level of the kidneys) is better at equalizing image quality than patient weight for pediatric Tc-99m DMSA renal function imaging. However, the correlation between image quality (IQ), AA, and patient girth has not been rigorously and systematically developed. In this work, we generate a series of curves showing the tradeoff between AA and IQ as a function of patient girth, providing the data for standards bodies to develop the next generation of dosing guideline for pediatric DMSA SPECT. METHODS: An anthropomorphic phantom series that included variations in age (5, 10, and 15 years), gender (M, F), local body morphometry (5, 10, 50, 90, and 95th girth percentiles), and kidney size (±15% standard size), was used to generate realistic SPECT projections. A fixed and clinically challenging defect-to-organ volume percentage (0.49% of renal cortex value) was used to model a focal defect with zero uptake (i.e., full local loss of renal function). Task-based IQ assessment methods were used to rigorously measure IQ in terms of renal perfusion defect detectability. This assessment was performed at multiple count levels (corresponding to various AAs) for groups of patients that had similar girths and defect sizes. Receiver-operating characteristics (ROC) analysis was applied; the area under the ROC curve (AUC) was used as a figure-of-merit for task performance. Curves showing the tradeoff between AUC and AA were generated for these groups of phantoms. RESULTS: Overall, the girth-based dosing method suggested different amounts of AA compared to weight-based dosing for the phantoms that had a relatively large body weight but a small girth or phantoms with relatively small bodyweight but large girth. Reductions of AA to 62.9% compared to weight-based dosing guidelines can potentially be realized while maintaining a baseline (AUC = 0.80) IQ for certain 15-year-olds who have a relatively small girth and large defect size. Note that the task-based IQ results are heavily dependent on the simulated defect size for the defect detection task and the appropriate AUC value must be decided by the physicians for this diagnostic task. These results are based purely on simulation and are subject to future clinical validation. CONCLUSIONS: The study provides simulation-based IQ-AA data for a girth-based dosing method for pediatric renal SPECT, suggesting that patient waist circumference at the level of kidneys should be considered in selecting the AA needed to achieve an acceptable IQ. This data may be useful for standards bodies to develop girth-based dosing guidelines.


Assuntos
Ácido Dimercaptossuccínico Tecnécio Tc 99m , Tomografia Computadorizada de Emissão de Fóton Único , Criança , Humanos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Rim , Imagens de Fantasmas , Simulação por Computador
2.
Magn Reson Med ; 85(6): 3169-3181, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33404086

RESUMO

PURPOSE: To investigate the ability of free induction decay navigator (FIDnav)-based motion monitoring to predict diagnostic utility and reduce the time and cost associated with acquiring diagnostically useful images in a pediatric patient cohort. METHODS: A study was carried out in 102 pediatric patients (aged 0-18 years) at 3T using a 32-channel head coil array. Subjects were scanned with an FID-navigated MPRAGE sequence and images were graded by two radiologists using a five-point scale to evaluate the impact of motion artifacts on diagnostic image quality. The correlation between image quality and four integrated FIDnav motion metrics was investigated, as well as the sensitivity and specificity of each FIDnav-based metric to detect different levels of motion corruption in the images. Potential time and cost savings were also assessed by retrospectively applying an optimal detection threshold to FIDnav motion scores. RESULTS: A total of 12% of images were rated as non-diagnostic, while a further 12% had compromised diagnostic value due to motion artifacts. FID-navigated metrics exhibited a moderately strong correlation with image grade (Spearman's rho ≥ 0.56). Integrating the cross-correlation between FIDnav signal vectors achieved the highest sensitivity and specificity for detecting non-diagnostic images, yielding total time savings of 7% across all scans. This corresponded to a financial benefit of $2080 in this study. CONCLUSIONS: Our results indicate that integrated motion metrics from FIDnavs embedded in structural MRI are a useful predictor of diagnostic image quality, which translates to substantial time and cost savings when applied to pediatric MRI examinations.


Assuntos
Algoritmos , Benchmarking , Adolescente , Artefatos , Encéfalo/diagnóstico por imagem , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Imageamento por Ressonância Magnética , Movimento (Física) , Estudos Retrospectivos
3.
Pediatr Radiol ; 50(5): 755-756, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32170349

RESUMO

The originally published version of this article contained a typographical error. In the text under the subheading "Dynamic contrast-enhanced MRI method, post-processing, and MR-GFR calculation" and in Table 1 the intravenous injection rate of gadobutrol was incorrectly listed as 0.2 mL/s.

4.
Pediatr Radiol ; 50(5): 698-705, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31984436

RESUMO

BACKGROUND: Current methods to estimate glomerular filtration rate (GFR) have shortcomings. Estimates based on serum creatinine are known to be inaccurate in the chronically ill and during acute changes in renal function. Gold standard methods such as inulin and 99mTc diethylenetriamine pentaacetic acid (DTPA) require blood or urine sampling and thus can be difficult to perform in children. Motion-robust radial volumetric interpolated breath-hold examination (VIBE) dynamic contrast-enhanced MRI represents a novel tool for estimating GFR that has not been validated in children. OBJECTIVE: The purpose of our study was to determine the feasibility and accuracy of GFR measured by motion-robust radial VIBE dynamic contrast-enhanced MRI compared to estimates by serum creatinine (eGFR) and 99mTc DTPA in children. MATERIALS AND METHODS: We enrolled children, 0-18 years of age, who were undergoing both a contrast-enhanced MRI and nuclear medicine 99mTc DTPA glomerular filtration rate (NM-GFR) within 2 weeks of each other. Enrolled children consented to an additional 6-min dynamic contrast-enhanced MRI scan using the motion-robust high spatiotemporal resolution prototype dynamic radial VIBE sequence (Siemens, Erlangen, Germany) at 3 tesla (T). The images were reconstructed offline with high temporal resolution (~3 s/volume) using compressed sensing image reconstruction including regularization in temporal dimension to improve image quality and reduce streaking artifacts. Images were then automatically post-processed using in-house-developed software. Post-processing steps included automatic segmentation of kidney parenchyma and aorta using convolutional neural network techniques and tracer kinetic model fitting using the Sourbron two-compartment model to calculate the MR-based GFR (MR-GFR). The NM-GFR was compared to MR-GFR and estimated GFR based on serum creatinine (eGFR) using Pearson correlation coefficient and Bland-Altman analysis. RESULTS: Twenty-one children (7 female, 14 male) were enrolled between February 2017 and May 2018. Data from six of these children were not further analyzed because of deviations from the MRI protocol. Fifteen patients were analyzed (5 female, 10 male; average age 5.9 years); the method was technically feasible in all children. The results showed that the MR-GFR correlated with NM-GFR with a Pearson correlation coefficient (r-value) of 0.98. Bland-Altman analysis (i.e. difference of MR-GFR and NM-GFR versus mean of NM-GFR and MR-GFR) showed a mean difference of -0.32 and reproducibility coefficient of 18 with 95% confidence interval, and the coefficient of variation of 6.7% with values between -19 (-1.96 standard deviation) and 18 (+1.96 standard deviation). In contrast, serum creatinine compared with NM-GFR yielded an r-value of 0.73. Bland-Altman analysis (i.e. difference of eGFR and NM-GFR versus mean of NM-GFR and eGFR) showed a mean difference of 2.9 and reproducibility coefficient of 70 with 95% confidence interval, and the coefficient of variation of 25% with values between -67 (-1.96 standard deviation) and 73 (+1.96 standard deviation). CONCLUSION: MR-GFR is a technically feasible and reliable method of measuring GFR when compared to the reference standard, NM-GFR by serum 99mTc DTPA, and MR-GFR is more reliable than estimates based on serum creatinine.


Assuntos
Meios de Contraste , Creatinina/sangue , Taxa de Filtração Glomerular/fisiologia , Aumento da Imagem/métodos , Rim/fisiologia , Imageamento por Ressonância Magnética/métodos , Pentetato de Tecnécio Tc 99m , Adolescente , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Lactente , Masculino , Estudos Prospectivos , Cintilografia , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes
5.
Skeletal Radiol ; 47(6): 821-831, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29332200

RESUMO

PURPOSE: To compare knee MRI performed with the integrated parallel acquisition technique (PAT) and simultaneous multislice (SMS) turbo spin echo (TSE) T2-weighted (T2w) sequences with conventional TSE sequences in pediatric patients. MATERIALS AND METHODS: This was a retrospective IRB-approved study. Seventy-four subjects (26 male, 48 female, mean age 15.3 years, range 8-20) underwent 3-T MRI of the knee with a T2w TSE pulse sequence prototype with four-fold PAT and SMS acceleration as well as the standard PAT-only accelerated sequences. Images were anonymized and two study folders were created: one examination with only T2w PAT2 images (conventional examination) and one examination with only T2w SMS2/PAT2 sequences (SMS examination). Two readers rated examinations for 15 specific imaging findings and 5 quality metrics. Interreader agreement was measured. Signal to noise (SNR) and contrast to noise (CNR) were measured for SMS and conventional T2w sequences. RESULTS: Consensus review demonstrated diagnostic quality performance of SMS examinations with respect to all 15 structures. Average area under the curve (AROC) was 0.95 and 0.97 for readers 1 and 2, respectively. The conventional sequence was favored over SMS for four out of five quality metrics (p < 0.001). SNR and CNR were higher for the conventional sequences compared to SMS. CONCLUSION: SMS accelerated T2w TSE sequences offer a faster alternative for knee imaging in pediatric patients without compromise in diagnostic performance despite diminished SNR. The four-fold acceleration of SMS is beneficial to pediatric patients who often have difficulty staying still for long MRI examinations.


Assuntos
Traumatismos do Joelho/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Criança , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...