Bone Joint J ; 100-B(6): 720-724, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29855241

RESUMO

Aims: Fretting and corrosion at the modular head/neck junction, known as trunnionosis, in total hip arthroplasty (THA) is a cause of adverse reaction to metal debris (ARMD). We describe the outcome of revision of metal-on-polyethylene (MoP) THA for ARMD due to trunnionosis with emphasis on the risk of major complications. Patients and Methods: A total of 36 patients with a MoP THA who underwent revision for ARMD due to trunnionosis were identified. Three were excluded as their revision had been to another metal head. The remaining 33 were revised to a ceramic head with a titanium sleeve. We describe the presentation, revision findings, and risk of complications in these patients. Results: The patients presented with pain, swelling, stiffness, or instability and an inflammatory mass was confirmed radiologically. Macroscopic material deposition on the trunnion was seen in all patients, associated with ARMD. Following revision, six (18.2%) dislocated, requiring further revision in four. Three (9.1%) developed a deep infection and six (18.2%) had significant persistent pain without an obvious cause. One developed a femoral artery thrombosis after excision of an iliofemoral pseudotumor, requiring a thrombectomy. Conclusion: The risk of serious complications following revision MoP THA for ARMD associated with trunnionosis is high. In the presence of extensive tissue damage, a constrained liner or dual mobility construct is recommended in these patients. Cite this article: Bone Joint J 2018;100-B:720-4.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Reoperação/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Corrosão , Feminino , Articulação do Quadril/cirurgia , Humanos , Masculino , Metais/efeitos adversos , Pessoa de Meia-Idade , Polietileno/efeitos adversos , Complicações Pós-Operatórias/etiologia , Desenho de Prótese/efeitos adversos , Falha de Prótese/efeitos adversos
2.
Bone Joint J ; 100-B(1 Supple A): 17-21, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29292335

RESUMO

Patients with neuromuscular imbalance who require total hip arthroplasty (THA) present particular technical problems due to altered anatomy, abnormal bone stock, muscular imbalance and problems of rehabilitation. In this systematic review, we studied articles dealing with THA in patients with neuromuscular imbalance, published before April 2017. We recorded the demographics of the patients and the type of neuromuscular pathology, the indication for surgery, surgical approach, concomitant soft-tissue releases, the type of implant and bearing, pain and functional outcome as well as complications and survival. Recent advances in THA technology allow for successful outcomes in these patients. Our review suggests excellent benefits for pain relief and good functional outcome might be expected with a modest risk of complication. Cite this article: Bone Joint J 2018;100-B(1 Supple A):17-21.


Assuntos
Artroplastia de Quadril , Doenças Neuromusculares/complicações , Osteoartrite do Quadril/cirurgia , Equilíbrio Postural , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Humanos , Doenças Neuromusculares/fisiopatologia , Osteoartrite do Quadril/complicações , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
3.
Bone Joint J ; 100-B(1 Supple A): 44-49, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29292339

RESUMO

AIMS: To present a surgically relevant update of trunnionosis. MATERIALS AND METHODS: Systematic review performed April 2017. RESULTS: Trunnionosis accounts for approximately 2% of the revision total hip arthroplasty (THA) burden. Thinner (reduced flexural rigidity) and shorter trunnions (reduced contact area at the taper junction) may contribute to mechanically assisted corrosion, exacerbated by high offset implants. The contribution of large heads and mixed metallurgy is discussed. CONCLUSION: Identifying causative risk factors is challenging due to the multifactorial nature of this problem. Cite this article: Bone Joint J 2018;100-B(1 Supple A):44-9.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Falha de Prótese/etiologia , Corrosão , Humanos , Desenho de Prótese , Reoperação , Fatores de Risco
4.
Bone Joint J ; 98-B(11): 1489-1496, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27803224

RESUMO

Fractures around total knee arthroplasties pose a significant surgical challenge. Most can be managed with osteosynthesis and salvage of the replacement. The techniques of fixation of these fractures and revision surgery have evolved and so has the assessment of outcome. This specialty update summarises the current evidence for the classification, methods of fixation, revision surgery and outcomes of the management of periprosthetic fractures associated with total knee arthroplasty. Cite this article: Bone Joint J 2016;98-B:1489-96.


Assuntos
Artroplastia do Joelho/efeitos adversos , Fraturas Periprotéticas/cirurgia , Medicina Baseada em Evidências/métodos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Humanos , Prótese do Joelho/efeitos adversos , Patela/diagnóstico por imagem , Patela/lesões , Fraturas Periprotéticas/diagnóstico por imagem , Fraturas Periprotéticas/etiologia , Falha de Prótese , Radiografia , Reoperação/métodos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/etiologia , Fraturas da Tíbia/cirurgia
5.
Bone Joint J ; 98-B(6): 767-71, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27235518

RESUMO

AIMS: Reconstruction of the acetabulum after failed total hip arthroplasty (THA) can be a surgical challenge in the presence of severe bone loss. We report the long-term survival of a porous tantalum revision acetabular component, its radiological appearance and quality of life outcomes. PATIENTS AND METHODS: We reviewed the results of 46 patients who had undergone revision of a failed acetabular component with a Paprosky II or III bone defect and reconstruction with a hemispherical, tantalum acetabular component, supplementary screws and a cemented polyethylene liner. RESULTS: After a minimum follow-up of ten years (ten to 12), the survivorship of the porous tantalum acetabular component was 96%, with further revision of the acetabular component as the end point. The ten-year survivorship, with hip revision for any reason as the end point, was 92%. We noted excellent pain relief (mean Western Ontario and McMaster Universities Arthritis Index (WOMAC) score pain 92.6, (40 to 100)) and good functional outcomes (mean WOMAC function 90.3 (30.9 to 100), mean University of California Los Angeles activity scale 5 (2 to 10)) and generic quality of life measures (mean Short Form-12 (SF-12) physical component 48.3 (18.1 to 56.8), mean SF-12 mental component 56.7 (32.9 to 70.3)). Patient satisfaction with pain relief, function and return to recreational activities were excellent. TAKE HOME MESSAGE: Uncemented acetabular reconstruction using a tantalum acetabular component gives excellent clinical and quality of life outcomes at a minimum follow-up of ten years. Cite this article: Bone Joint J 2016;98-B:767-71.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril , Prótese de Quadril , Tantálio , Acetábulo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Medição da Dor , Satisfação do Paciente , Porosidade , Qualidade de Vida , Reoperação , Adulto Jovem
6.
Bone Joint J ; 98-B(2): 187-93, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26850423

RESUMO

AIMS: We present a case series of ten metal-on-polyethylene total hip arthroplasties (MoP THAs) with delayed dislocation associated with unrecognised adverse local tissue reaction due to corrosion at the trunnion and pseudotumour formation. METHODS: The diagnosis was not suspected in nine of the ten patients (six female/four male; mean age 66 years), despite treatment in a specialist unit (mean time from index surgery to revision was 58 months, 36 to 84). It was identified at revision surgery and subsequently confirmed by histological examination of resected tissue. Pre-operative assessment and culture results ruled out infection. A variety of treatment strategies were used, including resection of the pseudotumour and efforts to avoid recurrent dislocation. RESULTS: The rate of complications was high and included three deep infections, two patients with recurrent dislocation, and one recurrent pseudotumour. CONCLUSION: This series (mean follow-up of 76 months following index procedure and 19 months following revision THA) demonstrates that pseudotumour is an infrequent but important contributor to delayed instability following MoP THA. It is easy to overlook in the differential diagnosis, especially if the alignment of the components is less than optimal, leading to an assumption that malalignment is the cause of the dislocation. The instability is likely to be multifactorial and the revision surgery is complex. TAKE HOME MESSAGE: Due to the high complication rate associated with revision in this cohort, the diagnosis should be borne in mind when counselling patients regarding the risks of revision surgery.


Assuntos
Artroplastia de Quadril/efeitos adversos , Luxação do Quadril/etiologia , Prótese de Quadril , Falha de Prótese/efeitos adversos , Idoso , Corrosão , Feminino , Granuloma de Células Plasmáticas/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Polietileno/efeitos adversos , Cuidados Pré-Operatórios/métodos , Recidiva , Reoperação
7.
Bone Joint J ; 98-B(1 Suppl A): 27-30, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26733637

RESUMO

Periprosthetic joint infection (PJI) complicates between 0.5% and 1.2% primary total hip arthroplasties (THAs) and may have devastating consequences. The traditional assessment of patients suffering from PJI has involved the serological study of inflammatory markers and microbiological analysis of samples obtained from the joint space. Treatment has involved debridement and revision arthroplasty performed in either one or two stages. We present an update on the burden of PJI, strategies for its diagnosis and treatment, the challenge of resistant organisms and the need for definitive evidence to guide the treatment of PJI after THA.


Assuntos
Prótese de Quadril/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Humanos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/terapia
8.
Bone Joint J ; 98-B(1 Suppl A): 50-3, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26733641

RESUMO

Tapered fluted titanium stems are increasingly used for femoral revision arthroplasty. They are available in modular and non-modular forms. Modularity has advantages when the bone loss is severe, the proximal femur is mis shapen or the surgeon is unfamiliar with the implant, but it introduces the risk of fracture of the stem at the junction between it and the proximal body segment. For that reason, and while awaiting intermediate-term results of more recently introduced designs of this junction, non-modularity has attracted attention, at least for straightforward revision cases. We review the risks and causes of fracture of tapered titanium modular revision stems and present an argument in favour of the more selective use of modular designs.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Falha de Prótese/etiologia , Titânio , Fêmur , Humanos , Desenho de Prótese , Reoperação , Fatores de Risco
9.
Bone Joint J ; 97-B(8): 1024-30, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26224816

RESUMO

Adverse reaction to wear and corrosion debris is a cause for concern in total hip arthroplasty (THA). Modular junctions are a potential source of such wear products and are associated with secondary pseudotumour formation. We present a consecutive series of 17 patients treated at our unit for this complication following metal-on-highly cross-linked polyethylene (MoP) THA. We emphasise the risk of misdiagnosis as infection, and present the aggregate laboratory results and pathological findings in this series. The clinical presentation was pain, swelling or instability. Solid, cystic and mixed soft-tissue lesions were noted on imaging and confirmed intra-operatively. Corrosion at the head-neck junction was noted in all cases. No bacteria were isolated on multiple pre- and intra-operative samples yet the mean erythrocyte sedimentation rate was 49 (9 to 100) and C-reactive protein 32 (0.6 to 106) and stromal polymorphonuclear cell counts were noted in nine cases. Adverse soft-tissue reactions can occur in MoP THA owing to corrosion products released from the head-neck junction. The diagnosis should be carefully considered when investigating pain after THA. This may avoid the misdiagnosis of periprosthetic infection with an unidentified organism and mitigate the unnecessary management of these cases with complete single- or two-stage exchange.


Assuntos
Artroplastia de Quadril/instrumentação , Reação a Corpo Estranho/diagnóstico , Prótese de Quadril/efeitos adversos , Falha de Prótese/efeitos adversos , Falha de Prótese/etiologia , Sedimentação Sanguínea , Proteína C-Reativa/análise , Contagem de Células , Corrosão , Erros de Diagnóstico , Reação a Corpo Estranho/etiologia , Humanos , Metais , Polietileno , Desenho de Prótese , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia
10.
Bone Joint J ; 96-B(12): 1669-73, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25452371

RESUMO

The Unified Classification System (UCS) was introduced because of a growing need to have a standardised universal classification system of periprosthetic fractures. It combines and simplifies many existing classification systems, and can be applied to any fracture around any partial or total joint replacement occurring during or after operation. Our goal was to assess the inter- and intra-observer reliability of the UCS in association with knee replacement when classifying fractures affecting one or more of the femur, tibia or patella. We used an international panel of ten orthopaedic surgeons with subspecialty fellowship training and expertise in adult hip and knee reconstruction ('experts') and ten residents of orthopaedic surgery in the last two years of training ('pre-experts'). They each received 15 radiographs for evaluation. After six weeks they evaluated the same radiographs again but in a different order. The reliability was assessed using the Kappa and weighted Kappa values. The Kappa values for inter-observer reliability for the experts and the pre-experts were 0.741 (95% confidence interval (CI) 0.707 to 0.774) and 0.765 (95% CI 0.733 to 0.797), respectively. The weighted Kappa values for intra-observer reliability for the experts and pre-experts were 0.898 (95% CI 0.846 to 0.950) and 0.878 (95% CI 0.815 to 0.942) respectively. The UCS has substantial inter-observer reliability and 'near perfect' intra-observer reliability when used for periprosthetic fractures in association with knee replacement in the hands of experienced and inexperienced users.


Assuntos
Artroplastia do Joelho , Fraturas do Fêmur/classificação , Fraturas Ósseas/classificação , Patela/lesões , Fraturas da Tíbia/classificação , Adulto , Humanos , Cooperação Internacional , Internato e Residência , Variações Dependentes do Observador , Ortopedia , Complicações Pós-Operatórias , Reprodutibilidade dos Testes
11.
Bone Joint J ; 96-B(11): 1472-7, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25371459

RESUMO

The Unified Classification System (UCS) emphasises the key principles in the assessment and management of peri-prosthetic fractures complicating partial or total joint replacement. We tested the inter- and intra-observer agreement for the UCS as applied to the pelvis and femur using 20 examples of peri-prosthetic fracture in 17 patients. Each subtype of the UCS was represented by at least one case. Specialist orthopaedic surgeons (experts) and orthopaedic residents (pre-experts) assessed reliability on two separate occasions. For the pelvis, the UCS showed inter-observer agreement of 0.837 (95% confidence intervals (CI) 0.798 to 0.876) for the experts and 0.728 (95% CI 0.689 to 0.767) for the pre-experts. The intra-observer agreement for the experts was 0.861 (95% CI 0.760 to 0.963) and 0.803 (95% 0.688 to 0.918) for the pre-experts. For the femur, the UCS showed an inter-observer kappa value of 0.805 (95% CI 0.765 to 0.845) for the experts and a value of 0.732 (95% CI 0.690 to 0.773) for the pre-experts. The intra-observer agreement was 0.920 (95% CI 0.867 to 0.973) for the experts, and 0.772 (95% CI 0.652 to 0.892) for the pre-experts. This corresponds to a substantial and 'almost perfect' inter- and intra-observer agreement for the UCS for peri-prosthetic fractures of the pelvis and femur. We hope that unifying the terminology of these injuries will assist in their assessment, treatment and outcome.


Assuntos
Artroplastia de Quadril , Fraturas Periprotéticas/classificação , Fraturas Periprotéticas/epidemiologia , Seguimentos , Saúde Global , Humanos , Incidência , Cooperação Internacional , Masculino , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
12.
Bone Joint J ; 96-B(11 Supple A): 56-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25381409

RESUMO

Non-modular tapered fluted, titanium stems are available for use in femoral revision. The combination of taper and flutes on the stem provides axial and rotational stability, respectively. The material and surface properties of the stem promotes bone on-growth. If the surgeon is confident and reasonably experienced in the surgical use of this sort of design and the case is relatively straightforward, a non-modular design is effective. It also potentially reduces implant inventory, and circumvents the potential problems of taper junction corrosion and fatigue fracture. There are reports of excellent survival, good clinical and functional results and evidence of subsequent increase in proximal bone stock.


Assuntos
Artroplastia de Quadril/instrumentação , Fêmur/cirurgia , Prótese de Quadril , Fraturas Periprotéticas/prevenção & controle , Titânio , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação
13.
Bone Joint J ; 96-B(11 Supple A): 60-5, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25381410

RESUMO

Advances in the treatment of periprosthetic joint infections of the hip have once more pushed prosthesis preserving techniques into the limelight. At the same time, the common infecting organisms are evolving to become more resistant to conventional antimicrobial agents. Whilst the epidemiology of resistant staphylococci is changing, a number of recent reports have advocated the use of irrigation and debridement and one-stage revision for the treatment of periprosthetic joint infections due to resistant organisms. This review presents the available evidence for the treatment of periprosthetic joint infections of the hip, concentrating in particular on methicillin resistant staphylococci.


Assuntos
Antibacterianos/uso terapêutico , Artroplastia de Quadril/efeitos adversos , Resistência a Meticilina , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Infecções Relacionadas à Prótese , Infecções Estafilocócicas , Saúde Global , Humanos , Incidência , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/microbiologia , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/epidemiologia , Infecções Estafilocócicas/microbiologia
16.
Bone Joint J ; 95-B(11 Suppl A): 17-20, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24187345

RESUMO

Tapered, fluted, modular, titanium stems are increasingly popular in the operative management of Vancouver B2 and selected B3 peri-prosthetic femoral fractures. We have reviewed the results at our institution looking at stem survival and clinical outcomes and compared this with reported outcomes in the literature. Stem survival at a mean of 54 months was 96% in our series and 97% for combined published cases. Review of radiology showed maintenance or improvement of bone stock in 89% of cases with high rates of femoral union. Favourable clinical outcome scores have reported by several authors. No difference in survival or clinical scores was observed between B2 and B3 fractures. Tapered stems are a useful option in revision for femoral fracture across the spectrum of femoral bone deficiency.


Assuntos
Artroplastia de Quadril/efeitos adversos , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Prótese de Quadril , Fraturas Periprotéticas/cirurgia , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Feminino , Fraturas do Fêmur/classificação , Fraturas do Fêmur/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas Periprotéticas/classificação , Fraturas Periprotéticas/diagnóstico por imagem , Qualidade de Vida , Radiografia , Reoperação , Estudos Retrospectivos , Taxa de Sobrevida , Titânio , Resultado do Tratamento
17.
Bone Joint J ; 95-B(11 Suppl A): 114-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24187367

RESUMO

Hip arthrodesis remains a viable surgical technique in well selected patients, typically the young manual labourer with isolated unilateral hip disease. Despite this, its popularity with patients and surgeons has decreased due to the evolution of hip replacement, and is seldom chosen by young adult patients today. The surgeon is more likely to encounter a patient who requests conversion to total hip replacement (THR). The most common indications are a painful pseudarthrosis, back pain, ipsilateral knee pain or contralateral hip pain. Occasionally the patient will request conversion because of difficulty with activities of daily living, body image and perceived cosmesis. The technique of conversion and a discussion of the results are presented.


Assuntos
Artrodese/métodos , Artroplastia de Quadril/métodos , Articulação do Quadril/cirurgia , Atividades Cotidianas , Imagem Corporal , Estética , Humanos , Seleção de Pacientes , Complicações Pós-Operatórias/cirurgia , Reoperação , Fatores de Risco
18.
J Bone Joint Surg Br ; 94(11 Suppl A): 58-60, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23118383

RESUMO

Tapered, fluted, modular, titanium stems have a long history in Europe and are increasing in popularity in North America. We have reviewed the results at our institution looking at stem survival and clinical outcomes. Radiological outcomes and quality of life assessments have been performed and compared to cylindrical non-modular cobalt chromium stems. Survival at five years was 94%. This fell to 85% at ten years due to stem breakage with older designs. Review of radiology showed maintenance or improvement of bone stock in 87% of cases. Outcome scores were superior in tapered stems despite worse pre-operative femoral deficiency. Tapered stems have proved to be a useful alternative in revision total hip arthroplasty across the spectrum of femoral bone deficiency.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Falha de Prótese , Infecções Relacionadas à Prótese/cirurgia , Seguimentos , Indicadores Básicos de Saúde , Prótese de Quadril/efeitos adversos , Humanos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Qualidade de Vida , Radiografia , Reoperação/instrumentação , Estudos Retrospectivos , Inquéritos e Questionários , Titânio , Resultado do Tratamento
19.
J Bone Joint Surg Br ; 94(11 Suppl A): 123-5, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23118399

RESUMO

Antibiotic impregnated articulating spacers are used in two-stage revision total knee arthroplasty to deliver local antibiotic therapy while preserving function. We have observed infection control in greater than 95% of cases with functional outcomes approaching those seen in revision for aseptic loosening. Higher failure has been observed with methicillin resistant organisms.


Assuntos
Antibacterianos/administração & dosagem , Artroplastia do Joelho/instrumentação , Sistemas de Liberação de Medicamentos , Prótese do Joelho/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Antibacterianos/uso terapêutico , Artroplastia do Joelho/métodos , Cimentos Ósseos , Terapia Combinada , Seguimentos , Humanos , Infecções Relacionadas à Prótese/tratamento farmacológico , Reoperação/instrumentação , Reoperação/métodos , Resultado do Tratamento
20.
J Bone Joint Surg Br ; 91(11): 1431-7, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19880885

RESUMO

We report the outcome at ten to 15 years of two-stage revision for hip infection in 99 patients using the Prostalac articulated hip spacer system. All the patients were contacted to determine their current functional and infection status using the Oxford-12, Short form-12, and Western Ontario and McMaster University Osteoarthritis Index questionnaires. A total of 11 of the 99 patients had a further infection, of whom seven responded to repeat surgery with no further sequelae. The mean interval between the stages was five months (1 to 36). We were able to review 48 living patients, with a mean age of 72 years (46 to 86), 34 (71%) of whom provided health-related quality-of-life outcome scores. The mean follow-up was 12 years (10 to 15). The long-term success rate was 89% and with additional surgery this rose to 96%. The mean global Western Ontario and McMaster University Osteoarthritis Index score was 80.6 (sd 18.3). The mean Oxford-12 score was 74.0 (sd 22.3), and the mean Short form-12 score was 53.1 (sd 9.4) (mental) and 33.5 (sd 13.5) (physical). The mean satisfaction score was 90.5 (sd 15.3). Two-stage revision for hip infection using a Prostalac interim spacer offers a predictable and lasting solution for patients with this difficult problem.


Assuntos
Antibacterianos/administração & dosagem , Artroplastia de Quadril/instrumentação , Infecções Bacterianas/cirurgia , Materiais Revestidos Biocompatíveis/uso terapêutico , Infecções Relacionadas à Prótese/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Infecções Bacterianas/tratamento farmacológico , Infecções Bacterianas/microbiologia , Sistemas de Liberação de Medicamentos , Feminino , Seguimentos , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/microbiologia , Qualidade de Vida , Reoperação/métodos , Índice de Gravidade de Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS