Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Res Cardiol ; 104(10): 799-802, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26133157

RESUMO

Hypertrophic cardiomyopathy (HCM) is one of the most common genetic cardiac conditions. Atrial fibrillation (AF) has been demonstrated to be the most frequent arrhythmia encountered in HCM patients. Research focusing on AF and embolic stroke in HCM patients has been sparse and the sample size of most studies is small. The prognostic significance of AF in HCM patients is still not well known. The aim of this article is to provide further understanding of the anti-coagulation requirement of HCM patients with AF.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/complicações , Cardiomiopatia Hipertrófica/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fibrilação Atrial/tratamento farmacológico , Cardiomiopatia Hipertrófica/tratamento farmacológico , Relação Dose-Resposta a Droga , Medicina Baseada em Evidências , Humanos , Seleção de Pacientes , Resultado do Tratamento
2.
Artigo em Inglês | MEDLINE | ID: mdl-25852237

RESUMO

AIMS: Limited data exist on outcomes in very elderly ICD recipients. We describe outcomes in new ICD and Cardiac Resynchronisation Therapy with Defibrillator (CRT-D) implants in octogenarians at our institution. METHODS: Patients aged 80 years and above who underwent de novo ICD or CRT-D implantation from January 2006 to July 2012 were identified. Clinical data were collected from the procedural record, medical and ICD notes. Baseline characteristics were compared using independent sample t test for continuous variables and Fisher's exact test for categorical variables. Kaplan-Meier curves were constructed. RESULTS: Ten per cent of all new ICD/CRT-D implants were aged 80 years and over. Median age was 83.0 years. Median follow-up was 29 months. Death occurred in 17 (34%). Median time to death was 23 months. Three deaths (6%) occurred within 12 months of ICD implantation. Appropriate therapy (ATP or shock) occurred in 19 (38%). Inappropriate therapy occurred in 6 (12%). Rates of appropriate shocks and inappropriate therapy (shocks and ATP) and significant valvular incompetence were higher amongst deceased patients (P=0.03 OR 5.9 95% CI 1.3-27) and (P=0.02 OR 12 95% CI 1.3-112). Univariate analysis identified diuretic use (P=0.008 95% C.I. 0.05 to 0.63) and appropriate shock (P= 0.025 95% C.I. 1.25 to 26.3) as predictors of mortality. CONCLUSION: Octogenarians make up a small but increasing number of ICD recipients. This study highlights high survival rates at one year with acceptable rates of appropriate and inappropriate device therapy. Ongoing debate regarding the appropriateness of ICD in very elderly patients is warranted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...