Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Med Radiat Sci ; 70 Suppl 2: 59-69, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36751021

RESUMO

INTRODUCTION: Magnetic resonance imaging (MRI) demonstrates superior soft tissue contrast and is increasingly being used in radiotherapy planning. This study evaluated the impact of an education workshop in minimising inter-observer variation (IOV) for nasopharyngeal organs at risk (OAR) delineation on MRI. METHODS: Ten observers delineated 14 OARs on 4 retrospective nasopharyngeal MRI data sets. Standard contouring guidelines were provided pre-workshop. Following an education workshop on MRI OAR delineation, observers blinded to their original contours repeated the 14 OAR delineations. For comparison, reference volumes were delineated by two head and neck radiation oncologists. IOV was evaluated using dice similarity coefficient (DSC), Hausdorff distance (HD) and relative volume. Location of largest deviations was evaluated with centroid values. Observer confidence pre- and post-workshop was also recorded using a 6-point Likert scale. The workshop was deemed beneficial for an OAR if ≥50% of observers mean scores improved in any metric and ≥50% of observers' confidence improved. RESULTS: All OARs had ≥50% of observers improve in at least one metric. Base of tongue, larynx, spinal cord and right temporal lobe were the only OARs achieving a mean DSC score of ≥0.7. Base of tongue, left and right lacrimal glands, larynx, left optic nerve and right parotid gland all exhibited statistically significant HD improvements post-workshop (P < 0.05). Brainstem and left and right temporal lobes all had statistically significant relative volume improvements post-workshop (P < 0.05). Post-workshop observer confidence improvement was observed for all OARs (P < 0.001). CONCLUSIONS: The educational workshop reduced IOV and improved observers' confidence when delineating nasopharyngeal OARs on MRI.


Assuntos
Imageamento por Ressonância Magnética , Radioterapia (Especialidade) , Humanos , Estudos Retrospectivos , Pescoço , Órgãos em Risco , Planejamento da Radioterapia Assistida por Computador/métodos , Variações Dependentes do Observador
2.
J Med Radiat Sci ; 69(4): 448-455, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35762562

RESUMO

INTRODUCTION: Head and neck cancer (HNC) patients are at risk of weight change, due to inadequate nutrition intake or dehydration, when receiving radiotherapy (RT). This study aimed to develop methodology to measure water content changes on magnetic resonance imaging (MRI) scans of the head and neck region over the course of RT. METHODS: Retrospective datasets of 54 patients were analysed. Eligible patients had been treated for HNC with cisplatin chemoradiation (CRT) or RT alone and underwent a minimum of 2 MRI scans from weeks 0, 3 and 6 of their treatment. Anatomical regions consisting of ≥90% water, on T2-weighted DIXON MRI sequences, were contoured. Water volume changes of all patients were evaluated, within an anatomically standardised external volume, by comparing the absolute water fraction volume (cc) (VEx90WF) and relative water fraction volume (%) (RelVEx90WF) at weeks 0 and 6 of RT. RESULTS: There was a statistically significant difference between the RelVEx90WF at weeks 0 and 6 (P = 0.005). However, no statistically significant difference was identified between weeks 0 and 6 VEx90WF (P = 0.064). There were no statistically significant differences identified between patients who received CRT versus RT alone. CONCLUSION: This study developed a novel method for measuring changes in water fraction volumes over time, using T2-weighted DIXON MRIs. The methodology created in this study requires further validation through phantom imaging, with known fat and water values.


Assuntos
Desidratação , Neoplasias de Cabeça e Pescoço , Humanos , Estudos Retrospectivos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Imageamento por Ressonância Magnética/métodos , Água
3.
J Med Radiat Sci ; 69(4): 473-483, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35715996

RESUMO

INTRODUCTION: The magnitude and impact of rotational error is unclear in rectal cancer radiation therapy. This study evaluates rotational errors in rectal cancer patients, and investigates the feasibility of planning target volume (PTV) margin reduction to decrease organs at risk (OAR) irradiation. METHODS: In this study, 10 patients with rectal cancer were retrospectively selected. Rotational errors were assessed through image registration of daily cone beam computed tomography (CBCT) and planning CT scans. Two reference treatment plans (TPR ) with PTV margins of 5 mm and 10 mm were generated for each patient. Pre-determined rotational errors (±1°, ±3°, ±5°) were simulated to produce six manipulated treatment plans (TPM ) from each TPR . Differences in evaluated dose-volume metrics between TPR and TPM of each rotation were compared using Wilcoxon Signed-Rank Test. Clinical compliance was investigated for statistically significant dose-volume metrics. RESULTS: Mean rotational errors in pitch, roll and yaw were -0.72 ± 1.81°, -0.04 ± 1.36° and 0.38 ± 0.96° respectively. Pitch resulted in the largest potential circumferential displacement of clinical target volume (CTV) at 1.42 ± 1.06 mm. Pre-determined rotational errors resulted in statistically significant differences in CTV, small bowel, femoral heads and iliac crests (P < 0.05). Only small bowel and iliac crests failed clinical compliance, with majority in the PTV 10 mm margin group. CONCLUSION: Rotational errors affected clinical compliance for OAR dose but exerted minimal impact on CTV coverage even with reduced PTV margins. Both PTV margin reduction and rotational correction decreased irradiated volume of OAR. PTV margin reduction to 5 mm is feasible, and rotational corrections are recommended in rectal patients to further minimise OAR irradiation.


Assuntos
Radioterapia de Intensidade Modulada , Neoplasias Retais , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Estudos Retrospectivos , Órgãos em Risco/efeitos da radiação , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/radioterapia
4.
J Med Radiat Sci ; 68(4): 379-388, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34288534

RESUMO

INTRODUCTION: Chemoradiotherapy (CRT) is the standard treatment for locally advanced cervical and vaginal cancer. It is associated with high haematological toxicity (HT) that can lead to treatment interruptions and cancelled chemotherapy cycles, reducing the potential effectiveness of this regimen. Bone marrow sparing (BMS) utilising volumetric modulated arc therapy (VMAT) is one method to reduce dose to the active bone marrow (ABM) so that HT rates are reduced. The aim of this paper was to assess whether BMS-VMAT can effectively spare the ABM whilst maintaining clinically acceptable target and organ-at-risk (OAR) doses. METHODS: Twenty gynaecological cancer patients treated with definitive CRT at the Liverpool/Macarthur Cancer Therapy centres between 2015 and 2020 were retrospectively included. ABM was delineated based on fluorodeoxyglucose positron emission tomography (FDG-PET) imaging. Weekly blood tests and ABM dose parameters at the V10Gy, V20Gy, V30Gy, V40Gy and Dmean were assessed on original plans for any potential correlation with grade 2+ HT. Replanned with VMAT for BMS, various dose parameters were compared with the original plan to assess for any significant differences. RESULTS: Active bone marrow doses were significantly reduced (P < 0.001 for all parameters) in BMS-VMAT plans, and significant improvements in target and OAR coverage were found compared with the original plans. Compared with VMAT only, target and OARs were comparable. No significant correlations between HT and ABM doses were found. CONCLUSION: Bone marrow sparing volumetric modulated arc therapy can significantly reduce dose to the active bone marrow whilst maintaining acceptable target and OAR doses. Future prospective trials are needed to evaluate the clinical impact of BMS on toxicity and compliance.


Assuntos
Radioterapia de Intensidade Modulada , Neoplasias Vaginais , Medula Óssea , Estudos de Viabilidade , Feminino , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/efeitos adversos , Estudos Retrospectivos
5.
Adv Radiat Oncol ; 6(3): 100650, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34195488

RESUMO

PURPOSE: This retrospective patient study assessed the consistency of abdominal gas presence throughout radiation therapy for patients with upper gastrointestinal cancer and determined the impact of variations in gas volume on the calculated dose distribution of volumetric modulated arc therapy. METHODS AND MATERIALS: Eight patients with pancreatic cancer were included for analysis. A plan library consisting of 3 reference plans per patient (Ref0.0, Ref0.5, and Ref1.0) was created based on planning computed tomography (CT) with density overrides of 0.0, 0.5, and 1.0 applied to gas volumes, respectively. Corresponding cone beam CT (CBCT) data sets were obtained and density overrides were applied to enable fractional dose calculation. Variation in gas volume relative to initial volume determined from CT was assessed. Dose metrics for targets and organs at risk were compared between the accumulated CBCT dose and the planned dose of the 3 reference plans for each patient. RESULTS: There was a significant decrease in gas present from CT to treatment CBCT, with a mean decrease in volume of 48.6% for the entire cohort. Dosimetrically, all accumulated target and organ-at-risk parameters, aside from the kidneys, exhibited the smallest mean deviation from the Ref0.0 plan and largest mean deviation from the Ref1.0 plan. A statistically significant difference in mean accumulated dose to Ref0.0 and Ref1.0 was observed for the dose delivered to 95% of the planning target volume. CONCLUSIONS: Significant variation in gas volumes from CT to treatment can occur throughout volumetric modulated arc therapy for pancreatic cancer. Through the use of a plan library, it was determined that initial assessment of a patient's treatment plan with an assigned gas density of 0.0 provided the most accurate prediction of the accumulated dose.

6.
J Med Radiat Sci ; 68(2): 157-166, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33283982

RESUMO

INTRODUCTION: Conventionally computed tomography (CT) has been used to delineate target volumes in radiotherapy; however, magnetic resonance imaging (MRI) is being continually integrated into clinical practice; therefore, the investigation into targets derived from MRI is warranted. The purpose of this study was to evaluate the impact of imaging modality (MRI vs. CT) and patient positioning (supine vs. prone) on planning target volumes (PTVs) and organs at risk (OARs) for partial breast irradiation (PBI). METHODS: A retrospective data set, of 35 patients, was accessed where each patient had undergone MRI and CT imaging for tangential whole breast radiotherapy in both the supine and prone position. PTVs were defined from seroma cavity (SC) volumes delineated on each respective image, resulting in 4 PTVs per patient. PBI plans were generated with 6MV external beam radiotherapy (EBRT) using the TROG 06.02 protocol guidelines. A prescription of 38.5Gy in 10 fractions was used for all cases. The impact analysis of imaging modality and patient positioning included dose to PTVs, and OARs based on agreed criteria. Statistical analysis was conducted though Mann-Whitey U, Fisher's exact and chi-squared testing (P < 0.005). RESULTS: Twenty-four patients were eligible for imaging analysis. However, positioning analysis could only be investigated on 19 of these data sets. No statistically significant difference was found in OAR doses based on imaging modality. Supine patient position resulted in lower contralateral breast dose (0.10Gy ± 0.35 vs. 0.33Gy ± 0.78, p = 0.011). Prone positioning resulted in a lower dose to ipsilateral lung volumes (10.85Gy ± 11.37 vs. 3.41Gy ± 3.93, P = <0.001). CONCLUSIONS: PBI plans with PTVs derived from MRI exhibited no clinically significant differences when compared to plans created from CT in relation to plan compliance and OAR dose. Patient position requires careful consideration regardless of imaging modality chosen. Although there was no proven superiority of MRI derived target volumes, it indicates that MRI could be considered for PBI target delineation.


Assuntos
Neoplasias da Mama , Imageamento por Ressonância Magnética , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Feminino , Humanos , Posicionamento do Paciente , Decúbito Ventral , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
7.
Artigo em Inglês | MEDLINE | ID: mdl-33251344

RESUMO

INTRODUCTION: While there is evidence to show the positive effects of automation, the impact on radiation oncology professionals has been poorly considered. This study examined radiation oncology professionals' perceptions of automation in radiotherapy planning. METHOD: An online survey link was sent to the chief radiation therapists (RT) of all Australian radiotherapy centres to be forwarded to RTs, medical physicists (MP) and radiation oncologists (RO) within their institution. The survey was open from May-July 2019. RESULTS: Participants were 204 RTs, 84 MPs and 37 ROs (response rates ∼10% of the overall radiation oncology workforce). Respondents felt automation resulted in improvement in consistency in planning (90%), productivity (88%), quality of planning (57%), and staff focus on patient care (49%). When asked about perceived impact of automation, the responses were; will change the primary tasks of certain jobs (66%), will allow staff to do the remaining components of their job more effectively (51%), will eliminate jobs (20%), and will not have an impact on jobs (6%). 27% of respondents believe automation will reduce job satisfaction. 71% of respondents strongly agree/agree that automation will cause a loss of skills, while only 25% strongly agree/agree that the training and education tools in their department are sufficient. CONCLUSION: Although the effect of automation is perceived positively, there are some concerns on loss of skillsets and the lack of training to maintain this. These results highlight the need for continued education to ensure that skills and knowledge are not lost with automation.

8.
Pract Radiat Oncol ; 8(3): e87-e97, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28993138

RESUMO

PURPOSE: The purpose of this study was to evaluate the impact of magnetic resonance imaging (MRI) versus computed tomography (CT)-derived planning target volumes (PTVs), in both supine and prone positions, for whole breast (WB) radiation therapy. METHODS AND MATERIALS: Four WB radiation therapy plans were generated for 28 patients in which PTVs were generated based on CT or MRI data alone in both supine and prone positions. A 6-MV tangential intensity modulated radiation therapy technique was used, with plans designated as ideal, acceptable, or noncompliant. Dose metrics for PTVs and organs at risk were compared to analyze any differences based on imaging modality (CT vs MRI) or patient position (supine vs prone). RESULTS: With respect to imaging modality 2/11 whole breast planning target volume (WB_PTV) dose metrics (percentage of PTV receiving 90% and 110% of prescribed dose) displayed statistically significant differences; however, these differences did not alter the average plan compliance rank. With respect to patient positioning, the odds of having an ideal plan versus a noncompliant plan were higher for the supine position compared with the prone position (P = .026). The minimum distance between the seroma cavity planning target volume (SC_PTV) and the chest wall was increased with prone positioning (P < .001, supine and prone values 1.1 mm and 8.7 mm, respectively). Heart volume was greater in the supine position (P = .005). Heart doses were lower in the supine position than prone (P < .01, mean doses 3.4 ± 1.55 Gy vs 4.4 ± 1.13 Gy for supine vs prone, respectively). Mean lung doses met ideal dose constraints in both positions, but were best spared in the prone position. The contralateral breast maximum dose to 1cc (D1cc) showed significantly lower doses in the supine position (P < .001, 4.64 Gy vs 9.51 Gy). CONCLUSIONS: Planning with PTVs generated from MRI data showed no clinically significant differences from planning with PTVs generated from CT with respect to PTV and doses to organs at risk. Prone positioning within this study reduced mean lung dose and whole heart volumes but increased mean heart and contralateral breast doses compared with supine.


Assuntos
Neoplasias da Mama/radioterapia , Imageamento por Ressonância Magnética/métodos , Posicionamento do Paciente/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade
9.
J Med Imaging Radiat Oncol ; 61(3): 394-401, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27863010

RESUMO

INTRODUCTION: This study aimed to evaluate the current use of imaging technologies for planning and delivery of radiotherapy (RT) in Australia. METHODS: An online survey was emailed to all Australian RT centres in August 2015. The survey inquired about imaging practices during planning and treatment delivery processes. Participants were asked about the types of image-guided RT (IGRT) technologies and the disease sites they were used for, reasons for implementation, frequency of imaging and future plans for IGRT use in their department. RESULTS: The survey was completed by 71% of Australian RT centres. All respondents had access to computed tomography (CT) simulators and regularly co-registered the following scans to the RT: diagnostic CT (50%), diagnostic magnetic resonance imaging (MRI) (95%), planning MRI (34%), planning positron emission tomography (PET) (26%) and diagnostic PET (97%) to aid in tumour delineation. The main reason for in-room IGRT implementation was the use of highly conformal techniques, while the most common reason for under-utilisation was lack of equipment capability. The most commonly used IGRT modalities were kilovoltage (kV) cone-beam CT (CBCT) (97%), kV electronic portal image (EPI) (89%) and megavoltage (MV) EPI (75%). Overall, participants planned to increase IGRT use in planning (33%) and treatment delivery (36%). CONCLUSIONS: IGRT is widely used among Australian RT centres. On the basis of future plans of respondents, the installation of new imaging modalities is expected to increase for both planning and treatment.


Assuntos
Padrões de Prática Médica/estatística & dados numéricos , Radioterapia (Especialidade)/tendências , Radioterapia Guiada por Imagem/estatística & dados numéricos , Austrália , Humanos , Planejamento da Radioterapia Assistida por Computador , Inquéritos e Questionários
10.
Int J Radiat Oncol Biol Phys ; 96(4): 905-912, 2016 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-27788960

RESUMO

PURPOSE: To determine whether T2-weighted MRI improves seroma cavity (SC) and whole breast (WB) interobserver conformity for radiation therapy purposes, compared with the gold standard of CT, both in the prone and supine positions. METHODS AND MATERIALS: Eleven observers (2 radiologists and 9 radiation oncologists) delineated SC and WB clinical target volumes (CTVs) on T2-weighted MRI and CT supine and prone scans (4 scans per patient) for 33 patient datasets. Individual observer's volumes were compared using the Dice similarity coefficient, volume overlap index, center of mass shift, and Hausdorff distances. An average cavity visualization score was also determined. RESULTS: Imaging modality did not affect interobserver variation for WB CTVs. Prone WB CTVs were larger in volume and more conformal than supine CTVs (on both MRI and CT). Seroma cavity volumes were larger on CT than on MRI. Seroma cavity volumes proved to be comparable in interobserver conformity in both modalities (volume overlap index of 0.57 (95% Confidence Interval (CI) 0.54-0.60) for CT supine and 0.52 (95% CI 0.48-0.56) for MRI supine, 0.56 (95% CI 0.53-0.59) for CT prone and 0.55 (95% CI 0.51-0.59) for MRI prone); however, after registering modalities together the intermodality variation (Dice similarity coefficient of 0.41 (95% CI 0.36-0.46) for supine and 0.38 (0.34-0.42) for prone) was larger than the interobserver variability for SC, despite the location typically remaining constant. CONCLUSIONS: Magnetic resonance imaging interobserver variation was comparable to CT for the WB CTV and SC delineation, in both prone and supine positions. Although the cavity visualization score and interobserver concordance was not significantly higher for MRI than for CT, the SCs were smaller on MRI, potentially owing to clearer SC definition, especially on T2-weighted MR images.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética , Posicionamento do Paciente/métodos , Seroma/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Mama/patologia , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Feminino , Humanos , Mastectomia Segmentar , Pessoa de Meia-Idade , Variações Dependentes do Observador , Tamanho do Órgão , Decúbito Ventral , Radio-Oncologistas , Radiologistas , Radioterapia Adjuvante , Seroma/patologia , Decúbito Dorsal
11.
J Appl Clin Med Phys ; 17(5): 7-19, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-28297426

RESUMO

The purpose of this study was to determine the impact of magnetic resonance imaging (MRI) geometric distortions when using MRI for target delineation and planning for whole-breast, intensity-modulated radiotherapy (IMRT). Residual system distortions and combined systematic and patient-induced distortions are considered. This retrospective study investigated 18 patients who underwent whole-breast external beam radiotherapy, where both CT and MRIs were acquired for treatment planning. Distortion phantoms were imaged on two MRI systems, dedicated to radiotherapy planning (a wide, closed-bore 3T and an open-bore 1T). Patient scans were acquired on the 3T system. To simulate MRI-based planning, distortion maps representing residual system distortions were generated via deformable registration between phantom CT and MRIs. Patient CT images and structures were altered to match the residual system distortion measured by the phantoms on each scanner. The patient CTs were also registered to the corresponding patient MRI scans, to assess patient and residual system effects. Tangential IMRT plans were generated and optimized on each resulting CT dataset, then propagated to the original patient CT space. The resulting dose distributions were then evaluated with respect to the standard clinically acceptable DVH and visual assessment criteria. Maximum residual systematic distortion was measured to be 7.9 mm (95%<4.7mm) and 11.9 mm (95%<4.6mm) for the 3T and 1T scanners, respectively, which did not result in clinically unacceptable plans. Eight of the plans accounting for patient and systematic distortions were deemed clinically unacceptable when assessed on the original CT. For these plans, the mean difference in PTV V95 (volume receiving 95% prescription dose) was 0.13±2.51% and -0.73±1.93% for right- and left-sided patients, respectively. Residual system distortions alone had minimal impact on the dosimetry for the two scanners investigated. The combination of MRI systematic and patient-related distortions can result in unacceptable dosimetry for whole-breast IMRT, a potential issue when considering MRI-only radiotherapy treatment planning. PACS number(s): 87.61.-c, 87.57.cp, 87.57.nj, 87.55.D.


Assuntos
Neoplasias da Mama/radioterapia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Órgãos em Risco/efeitos da radiação , Radiometria/métodos , Dosagem Radioterapêutica , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
12.
J Med Imaging Radiat Oncol ; 59(6): 736-42, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26269376

RESUMO

INTRODUCTION: Detailed, published surveys specific to Australian breast radiotherapy practice were last conducted in 2002. More recent international surveys specific to breast radiotherapy practice include a European survey conducted in 2008/2009 and a Spanish survey conducted in 2009. Radiotherapy techniques continue to evolve, and the utilisation of new techniques, such as intensity-modulated radiation therapy (IMRT), is increasing. This survey aimed to determine current breast radiotherapy practices across Australia. METHOD: An online survey was completed by 50 of the 69 Australian radiation therapy treatment centres. RESULTS: Supine tangential beam whole breast irradiation remains the standard of care for breast radiotherapy in Australia. A growing number of institutions are exploring prone positioning and IMRT utilisation. This survey demonstrated a wide variation in the benchmarks used to limit and report organ at risk doses, prescribed dose regimen, and post-mastectomy bolus practices. This survey also indicated, when compared with international literature, that there may be less interest in or uptake of external beam partial breast irradiation, prone positioning, simultaneous integrated boost and breath hold techniques. These are areas where further review and research may be warranted to ensure Australian patients are receiving the best care possible based on the best evidence available. CONCLUSION: This survey provides insight into the current radiotherapy practice for breast cancer in Australia.


Assuntos
Neoplasias da Mama/epidemiologia , Neoplasias da Mama/radioterapia , Padrões de Prática Médica/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia Guiada por Imagem/estatística & dados numéricos , Radioterapia/estatística & dados numéricos , Austrália/epidemiologia , Neoplasias da Mama/diagnóstico por imagem , Feminino , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Posicionamento do Paciente/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...