1.
Arthrosc Sports Med Rehabil ; 6(1): 100853, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38304466

RESUMO

Purpose: To assess the biomechanical performance of different stitching methods using a suturing device by comparing the elongation, stiffness, failure load, and time to stitch completion in cadaveric semitendinosus tendons (STs) and quadriceps tendons (QTs). Methods: A total of 24 STs and 16 QTs were harvested from cadaveric knee specimens (N = 40). Samples were randomly divided into 2 groups: whipstitch (WS) and whip-lock (WL) stitch. Both tendon ends were clamped to a graft preparation stand, and a 2-part needle was used to place 5 stitches, each 0.5 cm apart. Stitching time was recorded. Samples were preconditioned and then underwent cyclic loading from 50 to 200 N at 1 Hz for 500 cycles, followed by load-to-failure testing at 20 mm/min. Stiffness (in newtons per millimeter), ultimate failure load (in newtons), peak-to-peak displacement (in millimeters), elongation (in millimeters), and failure displacement (in millimeters) were recorded. Results: Completion of the WS was significantly faster than the WL stitch in the ST (P < .001) and QT (P = .004). For the ST, the WL stitch exhibited higher ultimate failure loads and construct stiffness than the WS. Regarding the QT, the WL stitch showed higher stiffness and displacement than the WS; however, the ultimate failure load was higher for the WS in the QT. The ultimate failure load in the QT was higher than that in the ST for both stitches. In the ST, only 25% of WSs and 100% of WL stitches failed due to suture breakage. In the QT, suture breakage led to the failure of 100% of both the WL stitches and WSs. Conclusions: In the ST, the WL stitch resulted in improved biomechanical performance through higher ultimate load and fewer failures from tissue damage compared with the WS. In the QT, both the WS and the WL stitch showed similar biomechanical performance with ultimate failure loads above established clinical failure thresholds. Clinical Relevance: Various types of ligament and tendon injuries require suturing to enable repair or reconstruction. The success of ligament or tendon surgery often relies on soft-tissue quality. It is important to investigate the biomechanical properties of stitching techniques that help preserve soft-tissue quality as a step to determining their clinical suitability.

2.
Orthopedics ; 44(3): e414-e416, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34039206

RESUMO

One method of preventing surgical-site infection is lowering intraoperative environmental contamination. The authors sought to evaluate their hospital's operating room (OR) contamination rate and compare it with the remainder of the hospital. They tested environmental contamination in preoperative, intraoperative, and postoperative settings for a total joint arthroplasty patient. A total of 190 air settle plates composed of trypsin soy agar were placed in 19 settings within the hospital. Locations included the OR with light and heavy traffic, with and without masks, jackets, and shoe covers; the substerile room; OR hallways; the sterile equipment processing center; preoperative areas; post-anesthesia care units; orthopedic floors; the emergency department; OR locker rooms and restrooms; a resident's home; and controls. The trypsin soy agar plates were incubated at 36 °C for 48 hours. Colony counts were performed for each plate. Average colony-forming units (CFUs) were calculated in each setting. The highest CFUs were in the OR locker room, at 28 CFUs per plate per hour. Preoperative and post-anesthesia care unit holding areas were 7.4 CFUs and 9.6 CFUs, respectively. The main orthopedic surgical ward had 10.0 CFUs per plate per hour, whereas the VIP hospital ward had 17.0 CFUs per plate per hour. All OR environments had low CFUs. A live OR had slightly higher CFUs than settings without OR personnel. In comparison with the local community household, the OR locker room, restrooms, hospital orthopedic wards, emergency department, preoperative holding, post-anesthesia care unit, and OR hallway all had higher airborne contamination. On the basis of these results, the authors recommend environmental sampling as a simple, fast, inexpensive tool for monitoring airborne contamination. [Orthopedics. 2021;44(3):e414-e416.].


Assuntos
Microbiologia do Ar , Hospitais , Salas Cirúrgicas , Infecção da Ferida Cirúrgica/prevenção & controle , Artroplastia de Substituição , Contagem de Colônia Microbiana , Serviço Hospitalar de Emergência , Humanos , Quartos de Pacientes , Roupa de Proteção/microbiologia , Equipamentos Cirúrgicos/microbiologia , Banheiros