Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Phys Med ; 32(9): 1082-7, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27599608

RESUMO

BACKGROUND AND PURPOSE: To study the impact of coronal and sagittal views (CSV) on the gross tumor volume (GTV) delineation on CT and matched PET/CT scans in non-small cell lung cancer. MATERIAL AND METHODS: GTV delineations were performed by 11 experienced radiation oncologists on CT and PET/CT in 22 patients. Two tumor groups were defined: Group I: Primary tumors surrounded by lung or visceral pleura, without venous invasion, and without large extensions to the chest wall or the mediastinum. Group II: Tumors invading the hilar region, heart, large vessels, pericardium, and the mediastinum and/or associated with atelectasis. Tumor volumes and inter-observers variations (SD) were calculated and compared according to the use of axial view only (AW), axial/coronal/sagittal views (ACSW) and ACSW/PET (ACSWP). RESULTS: CSV were not frequently used (57.4% out of 242 delineations on CT). For group I, ACSW didn't improve significantly mean GTVs. SDs were small on CT and on PET (SD=0.3cm). For group II, ACSW had 27-46% smaller observer variation (mean SD=0.7cm) than AW (mean SD=1.1cm). The smaller observer variation of ACSW users was associated with, on average, a 40% smaller delineated volume (p=0.038). Mean GTV of ACSWP was 21% larger than mean GTV of ACSW on CT. CONCLUSIONS: For smaller lung tumors surrounded by healthy lung tissue the effect of multiple axis delineation is limited. However, application of coronal and sagittal windows is highly beneficial for delineation of more complex tumors, with atelectasis and/or pathological lymph nodes even if PET is used.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Algoritmos , Braquiterapia/métodos , Calibragem , Simulação por Computador , Elétrons , Humanos , Método de Monte Carlo , Fótons , Probabilidade , Reprodutibilidade dos Testes , Software , Incerteza
2.
Radiother Oncol ; 112(3): 418-24, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24996454

RESUMO

PURPOSE: The aim of this study is to ascertain the subsequent radiobiological impact of using a consensus guideline target volume delineation atlas. MATERIALS AND METHODS: Using a representative case and target volume delineation instructions derived from a proposed IMRT rectal cancer clinical trial, gross tumor volume (GTV) and clinical/planning target volumes (CTV/PTV) were contoured by 13 physician observers (Phase 1). The observers were then randomly assigned to follow (atlas) or not-follow (control) a consensus guideline/atlas for anorectal cancers, and instructed to re-contour the same case (Phase 2). RESULTS: The atlas group was found to have increased tumor control probability (TCP) after the atlas intervention for both the CTV (p<0.0001) and PTV1 (p=0.0011) with decreasing normal tissue complication probability (NTCP) for small intestine, while the control group did not. Additionally, the atlas group had reduced variance in TCP for all target volumes and reduced variance in NTCP for the bowel. In Phase 2, the atlas group had increased TCP relative to the control for CTV (p=0.03). CONCLUSIONS: Visual atlas and consensus treatment guideline usage in the development of rectal cancer IMRT treatment plans reduced the inter-observer radiobiological variation, with clinically relevant TCP alteration for CTV and PTV volumes.


Assuntos
Comportamento Cooperativo , Guias de Prática Clínica como Assunto , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Retais/radioterapia , Simulação por Computador , Consenso , Humanos , Masculino , Variações Dependentes do Observador , Estudos Prospectivos , Radiobiologia/métodos , Neoplasias Retais/patologia , Carga Tumoral
3.
Radiat Oncol ; 7: 32, 2012 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-22414264

RESUMO

BACKGROUND: Consistent delineation of patient anatomy becomes increasingly important with the growing use of highly conformal and adaptive radiotherapy techniques. This study investigates the magnitude and 3D localization of interobserver variability of organs at risk (OARs) in the head and neck area with application of delineation guidelines, to establish measures to reduce current redundant variability in delineation practice. METHODS: Interobserver variability among five experienced radiation oncologists was studied in a set of 12 head and neck patient CT scans for the spinal cord, parotid and submandibular glands, thyroid cartilage, and glottic larynx. For all OARs, three endpoints were calculated: the Intraclass Correlation Coefficient (ICC), the Concordance Index (CI) and a 3D measure of variation (3D SD). RESULTS: All endpoints showed largest interobserver variability for the glottic larynx (ICC = 0.27, mean CI = 0.37 and 3D SD = 3.9 mm). Better agreement in delineations was observed for the other OARs (range, ICC = 0.32-0.83, mean CI = 0.64-0.71 and 3D SD = 0.9-2.6 mm). Cranial, caudal, and medial regions of the OARs showed largest variations. All endpoints provided support for improvement of delineation practice. CONCLUSIONS: Variation in delineation is traced to several regional causes. Measures to reduce this variation can be: (1) guideline development, (2) joint delineation review sessions and (3) application of multimodality imaging. Improvement of delineation practice is needed to standardize patient treatments.


Assuntos
Neoplasias de Cabeça e Pescoço/epidemiologia , Neoplasias de Cabeça e Pescoço/radioterapia , Órgãos em Risco/diagnóstico por imagem , Radioterapia (Especialidade)/normas , Humanos , Imageamento Tridimensional , Variações Dependentes do Observador , Tomografia Computadorizada por Raios X
4.
Radiother Oncol ; 103(2): 178-82, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22265730

RESUMO

AIMS: To investigate whether using a pre-operative CT scan (Preop-CT) (1) decreases interobserver variation of boost-CTV delineation in breast conserving therapy (BCT), and (2) influences the size of the delineated volumes. PATIENTS AND METHODS: Thirty cT1-2N0-1 breast cancer patients underwent a CT-scan in radiation treatment position, prior to and after lumpectomy. Five observers delineated a boost-CTV, both with and without access to the Preop-CT. For each patient and for each observer pair, the conformity index (CI) and the distance between the centres of mass (COMd) for both boost volumes were calculated. In addition, all delineated volumes including the standard deviation (SD) with respect to the median delineation were calculated. RESULTS: Using a Preop-CT reduced the mean COMd of the boost-CTV from 1.1cm to 1.0 cm (p<0.001). No effect was seen on the CI, but the boost-CTV volume reduced from 42 cc to 36 cc (p=0.005), implying a reduction of interobserver variation. We saw no significant change in the SD. CONCLUSION: Use of a Preop-CT in BCT results in a modest but statistically significant reduction in interobserver variation of the boost-CTV delineations and in a significant reduction in the boost-CTV volume.


Assuntos
Neoplasias da Mama/radioterapia , Radioterapia Guiada por Imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Carga Tumoral
5.
Int J Radiat Oncol Biol Phys ; 79(2): 481-9, 2011 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20400244

RESUMO

PURPOSE: Variations in target volume delineation represent a significant hurdle in clinical trials involving conformal radiotherapy. We sought to determine the effect of a consensus guideline-based visual atlas on contouring the target volumes. METHODS AND MATERIALS: A representative case was contoured (Scan 1) by 14 physician observers and a reference expert with and without target volume delineation instructions derived from a proposed rectal cancer clinical trial involving conformal radiotherapy. The gross tumor volume (GTV), and two clinical target volumes (CTVA, including the internal iliac, presacral, and perirectal nodes, and CTVB, which included the external iliac nodes) were contoured. The observers were randomly assigned to receipt (Group A) or nonreceipt (Group B) of a consensus guideline and atlas for anorectal cancers and then instructed to recontour the same case/images (Scan 2). Observer variation was analyzed volumetrically using the conformation number (CN, where CN = 1 equals total agreement). RESULTS: Of 14 evaluable contour sets (1 expert and 7 Group A and 6 Group B observers), greater agreement was found for the GTV (mean CN, 0.75) than for the CTVs (mean CN, 0.46-0.65). Atlas exposure for Group A led to significantly increased interobserver agreement for CTVA (mean initial CN, 0.68, after atlas use, 0.76; p = .03) and increased agreement with the expert reference (initial mean CN, 0.58; after atlas use, 0.69; p = .02). For the GTV and CTVB, neither the interobserver nor the expert agreement was altered after atlas exposure. CONCLUSION: Consensus guideline atlas implementation resulted in a detectable difference in interobserver agreement and a greater approximation of expert volumes for the CTVA but not for the GTV or CTVB in the specified case. Visual atlas inclusion should be considered as a feature in future clinical trials incorporating conformal RT.


Assuntos
Neoplasias Retais/diagnóstico por imagem , Carga Tumoral , Método Duplo-Cego , Humanos , Ilustração Médica , Variações Dependentes do Observador , Projetos Piloto , Estudos Prospectivos , Radioterapia (Especialidade) , Radiografia , Radioterapia Conformacional/métodos , Neoplasias Retais/patologia , Neoplasias Retais/radioterapia
6.
Radiother Oncol ; 94(3): 286-91, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20199818

RESUMO

PURPOSE: This study aims to determine magnitude, causes and consequences of post-operative breast tumour target volume delineation variation among radiation oncologists in the presence of guidelines. MATERIALS AND METHODS: Excision cavities, CTVs and PTVs of eight breast cancer patients were delineated on CT scans by 13 Dutch radiation oncologists (observers) from 12 Dutch institutes participating in the international Young Boost Trial. Delineated volumes and conformity indices were determined. CTV delineation variation (SD) was determined for anatomically relevant regions. Non-parametric statistics were performed to establish effects of observers, patient characteristics and regions on delineation variation. RESULTS: Even in the presence of delineation guidelines considerable delineation variation is present (0.24

Assuntos
Neoplasias da Mama/radioterapia , Carga Tumoral , Adulto , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Feminino , Guias como Assunto , Humanos , Pessoa de Meia-Idade , Países Baixos , Variações Dependentes do Observador
7.
Radiat Oncol ; 5: 21, 2010 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-20230613

RESUMO

PURPOSE: To determine the variation in target delineation of nasopharyngeal carcinoma and the impact of measures to minimize this variation. MATERIALS AND METHODS: For ten nasopharyngeal cancer patients, ten observers each delineated the Clinical Target Volume (CTV) and the CTV elective. After 3D analysis of the delineated volumes, a second delineation was performed. This implied improved delineation instructions, a combined delineation on CT and co-registered MRI, forced use of sagittal reconstructions, and an on-line anatomical atlas. RESULTS: Both for the CTV and the CTV elective delineations, the 3D SD decreased from Phase 1 to Phase 2, from 4.4 to 3.3 mm for the CTV and from 5.9 to 4.9 mm for the elective. There was an increase agreement, where the observers intended to delineate the same structure, from 36 to 64 surface % (p = 0.003) for the CTV and from 17 to 59% (p = 0.004) for the elective. The largest variations were at the caudal border of the delineations but these were smaller when an observer utilized the sagittal window. Hence, the use of sagittal side windows was enforced in the second phase and resulted in a decreased standard deviation for this area from 7.7 to 3.3 mm (p = 0.001) for the CTV and 7.9 to 5.6 mm (p = 0.03) for the CTV elective. DISCUSSION: Attempts to decrease the variation need to be tailored to the specific causes of the variation. Use of delineation instructions multimodality imaging, the use of sagittal windows and an on-line atlas result in a higher agreement on the intended target.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias Nasofaríngeas/patologia , Neoplasias Nasofaríngeas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Neoplasias Nasofaríngeas/epidemiologia , Variações Dependentes do Observador , Radioterapia Conformacional
8.
Int J Radiat Oncol Biol Phys ; 70(5): 1403-7, 2008 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-17980511

RESUMO

PURPOSE: To derive guidelines for the need to use positron emission tomography (PET) for delineation of the primary tumor (PT) according to its anatomical location in the lung. METHODS AND MATERIALS: In 22 patients with non-small-cell lung cancer, thoracic X-ray computed tomography (CT) and PET were performed. Eleven radiation oncologists delineated the PT on the CT and on the CT-PET registered scans. The PTs were classified into two groups. In Group I patients, the PT was surrounded by lung or visceral pleura, without venous invasion, without extension to chest wall or the mediastinum over more than one quarter of its surface. In Group II patients, the PT invaded the hilar region, heart, great vessels, pericardium, mediastinum over more than one quarter of its surface and/or associated with atelectasis. A comparison of interobserver variability for each group was performed and expressed as a local standard deviation. RESULTS: The comparison of delineations showed a good reproducibility for Group I, with an average SD of 0.4 cm on CT and an average SD of 0.3 cm on CT-PET (p = 0.1628). There was also a significant improvement with CT-PET for Group II, with an average SD of 1.3 cm on CT and SD of 0.4 cm on CT-PET (p = 0.0003). The improvement was mainly located at the atelectasis/tumor interface. At the tumor/lung and tumor/hilum interfaces, the observer variation was similar with both modalities. CONCLUSIONS: Using PET for PT delineation is mandatory to decrease interobserver variability in the hilar region, heart, great vessels, pericardium, mediastinum, and/or the region associated with atelectasis; however it is not essential for delineation of PT surrounded by lung or visceral pleura, without venous invasion or extension to the chest wall.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Variações Dependentes do Observador , Atelectasia Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes
9.
Radiother Oncol ; 83(1): 42-8, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17343940

RESUMO

PURPOSE: To evaluate the image quality of retrospectively attenuation corrected Positron Emission Tomography (PET) scans used for gross tumor volume (GTV) delineation in lung cancer patients. MATERIALS AND METHODS: Data of 13 lymph node positive lung cancer patients were acquired on separate CT and PET scanners under free breathing conditions (for radiotherapy planning). First we determined a protocol for CT/PET registration. Second, we compared the image quality of attenuation-corrected PET images using positron transmission images and CT images, in terms of signal-to-noise ratio (SNR) and lesion-to-background ratio (contrast). RESULTS: The largest differences between manual and automatic CT/PET registration were found in the anterior-posterior direction with a mean of 1.8 mm (SD 1.0 mm). Differences in rotations were always smaller than 1.0 degrees . The attenuation-corrected images using CT showed a larger SNR (mean 30%, SD 17%) and larger contrast (mean 14.0%, SD 8.5%) compared to attenuation-corrected images using positron transmission. For lymph nodes, the mean contrast was 16% (SD 6.4%) larger. CONCLUSIONS: This study demonstrated that attenuation correction based on CT provides a better image quality for GTV delineation than when using positron transmission for attenuation correction. Retrospective attenuation correction of PET scans based on registered CT is a good alternative for a dedicated PET/CT scanner if a free-breathing CT is available, e.g., for radiotherapy planning, and allows the use of CT with diagnostic quality for attenuation correction.


Assuntos
Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/radioterapia , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Idoso , Feminino , Humanos , Aumento da Imagem , Neoplasias Pulmonares/diagnóstico por imagem , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Respiração
10.
Int J Radiat Oncol Biol Phys ; 64(5): 1551-8, 2006 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-16580504

RESUMO

PURPOSE: First, to quantify bladder-tumor motion in 3 dimensions during a 4-week to 5-week course of external radiotherapy. Second, to relate the motion to the tumor location on the bladder wall. Third, to extensively evaluate gross tumor volume (GTV) shape and volume changes during the course of the treatment. METHODS AND MATERIALS: Multiple repeat computed tomography (CT) images were obtained for 21 bladder cancer patients. These scans were matched to the rigid bony anatomy. For each patient, the main direction and magnitude of the tumor movement was determined by use of principle-component analysis. To study GTV shape changes, all GTVs were registered to the GTV in the planning CT scan, and the residual shape errors were determined by measurement of edge variations perpendicular to the median surface. RESULTS: Gross tumor volume translations were largest in cranial-caudal and anterior-posterior direction (SD, 0.1 to approximately 0.9 cm). The translations were strongly correlated with the tumor location on the bladder wall. The average value of the local standard deviations of the GTV shape ranged from 0.1 to approximately 0.35 cm. CONCLUSIONS: Despite large differences in bladder filling, variations in GTV shape were small compared with variations in GTV position. Geometric uncertainties in the GTV position depended strongly on the tumor location on the bladder wall.


Assuntos
Movimento , Radioterapia Assistida por Computador/métodos , Neoplasias da Bexiga Urinária/radioterapia , Bexiga Urinária , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/patologia , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/patologia
11.
Int J Radiat Oncol Biol Phys ; 64(2): 435-48, 2006 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-16198064

RESUMO

PURPOSE: Target delineation using only CT information introduces large geometric uncertainties in radiotherapy for lung cancer. Therefore, a reduction of the delineation variability is needed. The impact of including a matched CT scan with 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) and adaptation of the delineation protocol and software on target delineation in lung cancer was evaluated in an extensive multi-institutional setting and compared with the delineations using CT only. METHODS AND MATERIALS: The study was separated into two phases. For the first phase, 11 radiation oncologists (observers) delineated the gross tumor volume (GTV), including the pathologic lymph nodes of 22 lung cancer patients (Stages I-IIIB) on CT only. For the second phase (1 year later), the same radiation oncologists delineated the GTV of the same 22 patients on a matched CT-FDG-PET scan using an adapted delineation protocol and software (according to the results of the first phase). All delineated volumes were analyzed in detail. The observer variation was computed in three dimensions by measuring the distance between the median GTV surface and each individual GTV. The variation in distance of all radiation oncologists was expressed as a standard deviation. The observer variation was evaluated for anatomic regions (lung, mediastinum, chest wall, atelectasis, and lymph nodes) and interpretation regions (agreement and disagreement; i.e., >80% vs. <80% of the radiation oncologists delineated the same structure, respectively). All radiation oncologist-computer interactions were recorded and analyzed with a tool called "Big Brother." RESULTS: The overall three-dimensional observer variation was reduced from 1.0 cm (SD) for the first phase (CT only) to 0.4 cm (SD) for the second phase (matched CT-FDG-PET). The largest reduction in the observer variation was seen in the atelectasis region (SD 1.9 cm reduced to 0.5 cm). The mean ratio between the common and encompassing volume was 0.17 and 0.29 for the first and second phases, respectively. For the first phase, the common volume was 0 in 4 patients (i.e., no common point for all GTVs). In the second phase, the common volume was always >0. For all anatomic regions, the interpretation differences among the radiation oncologists were reduced. The amount of disagreement was 45% and 18% for the first and second phase, respectively. Furthermore, the mean delineation time (12 vs. 16 min, p<0.001) and mean number of corrections (25 vs. 39, p<0.001) were reduced in the second phase compared with the first phase. CONCLUSION: For high-precision radiotherapy, the delineation of lung target volumes using only CT introduces too great a variability among radiation oncologists. Implementing matched CT-FDG-PET and adapted delineation protocol and software reduced observer variation in lung cancer delineation significantly with respect to CT only. However, the remaining observer variation was still large compared with other geometric uncertainties (setup variation and organ motion).


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Variações Dependentes do Observador , Tomografia Computadorizada de Emissão/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Diagnóstico por Computador , Feminino , Fluordesoxiglucose F18/uso terapêutico , Humanos , Pulmão/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Masculino , Mediastino/diagnóstico por imagem , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/uso terapêutico , Parede Torácica/diagnóstico por imagem
12.
Radiother Oncol ; 77(2): 182-90, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16256231

RESUMO

BACKGROUND AND PURPOSE: To evaluate the process of target volume delineation in lung cancer for optimization of imaging, delineation protocol and delineation software. PATIENTS AND METHODS: Eleven radiation oncologists (observers) from five different institutions delineated the Gross Tumor Volume (GTV) including positive lymph nodes of 22 lung cancer patients (stages I-IIIB) on CT only. All radiation oncologist-computer interactions were recorded with a tool called 'Big Brother'. For each radiation oncologist and patient the following issues were analyzed: delineation time, number of delineated points and corrections, zoom levels, level and window (L/W) settings, CT slice changes, use of side windows (coronal and sagittal) and software button use. RESULTS: The mean delineation time per GTV was 16 min (SD 10 min). The mean delineation time for lymph node positive patients was on average 3 min larger (P = 0.02) than for lymph node negative patients. Many corrections (55%) were due to L/W change (e.g. delineating in mediastinum L/W and then correcting in lung L/W). For the lymph node region, a relatively large number of corrections was found (3.7 corr/cm2), indicating that it was difficult to delineate lymph nodes. For the tumor-atelectasis region, a relative small number of corrections was found (1.0 corr/cm2), indicating that including or excluding atelectasis into the GTV was a clinical decision. Inappropriate use of L/W settings was frequently found (e.g. 46% of all delineated points in the tumor-lung region were delineated in mediastinum L/W settings). Despite a large observer variation in cranial and caudal direction of 0.72 cm (1 SD), the coronal and sagittal side windows were not used in 45 and 60% of the cases, respectively. For the more difficult cases, observer variation was smaller when the coronal and sagittal side windows were used. CONCLUSIONS: With the 'Big Brother' tool a method was developed to trace the delineation process. The differences between observers concerning the delineation style were large. This study led to recommendations on how to improve delineation accuracy by adapting the delineation protocol (guidelines for L/W use) and delineation software (double window with lung and mediastinum L/W settings at the same time, enforced use of coronal and sagittal views) and including FDG-PET information (lymph nodes and atelectasis).


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/instrumentação , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/patologia , Estudos de Coortes , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Segurança de Equipamentos , Estudos de Avaliação como Assunto , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Variações Dependentes do Observador , Padrões de Prática Médica , Radioterapia (Especialidade)/normas , Radioterapia (Especialidade)/tendências , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Medição de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Resultado do Tratamento
13.
Int J Radiat Oncol Biol Phys ; 60(5): 1364-72, 2004 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-15590166

RESUMO

PURPOSE: To evaluate the impact of different tabletops with or without a knee support on the position of the rectum, prostate, and bulb of the penis; and to evaluate the effect of these patient-positioning devices on treatment planning. METHODS AND MATERIALS: For 10 male volunteers, five MRI scans were made in four different positions: on a flat tabletop with knee support, on a flat tabletop without knee support, on a rounded tabletop with knee support, and on a rounded tabletop without knee support. The fifth scan was in the same position as the first. With image registration, the position differences of the rectum, prostate, and bulb of the penis were measured at several points in a sagittal plane through the central axis of the prostate. A planning target volume was generated from the delineated prostates with a margin of 10 mm in three dimensions. A three-field treatment plan with a prescribed dose of 78 Gy to the International Commission on Radiation Units and Measurements point was automatically generated from each planning target volume. Dose-volume histograms were calculated for all rectal walls. RESULTS: The shape of the tabletop did not affect the rectum and prostate position. Addition of a knee support shifted the anterior and posterior rectal walls dorsally. For the anterior rectal wall, the maximum dorsal shift was 9.9 mm (standard error of the mean [SEM] 1.7 mm) at the top of the prostate. For the posterior rectal wall, the maximum dorsal shift was 10.2 mm (SEM 1.5 mm) at the middle of the prostate. Therefore, the rectal filling was pushed caudally when a knee support was added. The knee support caused a rotation of the prostate around the left-right axis at the apex (i.e., a dorsal rotation) by 5.6 degrees (SEM 0.8 degrees ) and shifts in the caudal and dorsal directions of 2.6 mm (SEM 0.4 cm) and 1.4 mm (SEM 0.6 mm), respectively. The position of the bulb of the penis was not influenced by the use of a knee support or rounded tabletop. The volume of the rectal wall receiving the same dose range (e.g., 40-75 Gy) was reduced by 3.5% (SEM 0.9%) when a knee support was added. No significant differences were observed between the first and fifth scan (flat tabletop with knee support) for all measured points, thereby excluding time trends. CONCLUSIONS: The rectum and prostate were significantly shifted dorsally by the use of a knee support. The rectum shifted more than the prostate, resulting in a dose benefit compared with irradiation without knee support. The shape of the tabletop did not influence the rectum or prostate position.


Assuntos
Equipamentos e Provisões Hospitalares , Pênis/anatomia & histologia , Postura , Próstata/anatomia & histologia , Neoplasias da Próstata/radioterapia , Reto/anatomia & histologia , Desenho de Equipamento , Humanos , Imageamento por Ressonância Magnética , Masculino , Radioterapia Conformacional , Decúbito Dorsal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA